Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.6 LAccepted-AOC 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | ₹24.6 L | L1 | Accepted-AOC AOC_Issued |
| 2 | L2₹24.9 LRejected-Finance A 8 SAKHARAM GANESH DAUSKAR SARANI KOLKATA 700 025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | ₹24.9 L | L2 | Rejected-Finance That the BID is not L1 |
| 3 | L3₹25.2 LRejected-Finance | ₹25.2 L | L3 | Rejected-Finance That the BID is not L1 |
| 4 | L4₹27.5 LRejected-Finance | ₹27.5 L | L4 | Rejected-Finance That the BID is not L1 |
| 5 | L5₹27.7 LRejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | ₹27.7 L | L5 | Rejected-Finance That the BID is L1 |
| Sl No | Description | Qty | Unit | Lyric International L5 | SKY DECORATIONS PRIVATE LIMITED L1 | MAXCOOL REFRIGERATION CO. L2 | ANIKET COOLING AND REFRIGERATION CO L8 | jhonson controls hitachi air conditioning india limited L3 | M.S. COOLING & ENGINEERING CO. L7 | P. M. COOLING AND ENGINEERING CO L6 | TRANSTECH L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply & Delivery of 230V,1-Ph, 50Hz, 2Tr. capacity Concealed Split Air Conditioning Machine along with 1 no. IDU of rated Cooling Capacity:- 24000 BTU/HR, Compressor:- Rotary Type, Remote Control:- Yes, Condenser Coil:- Copper, Refrigerant Type:- R-410A/R-32/R-22, Air Flow/IDU:- 800CFM, Operating Mode:- Cool & Fan Mode, Sleep Mode:- Yes, Timer:- Yes.
(Make:- Daikin/Voltas/Hitachi/O General) | 30 | Nos. | 66,000 ₹19.8 L | 62,500 ₹18.8 L | 62,600 ₹18.8 L | 70,250 ₹21.1 L | 62,700 ₹18.8 L | 69,000 ₹20.7 L | 68,750 ₹20.6 L | 70,760 ₹21.2 L |
| 2.00 | Supply & Delivery of 230V,1-Ph, 50Hz, 1.5Tr. capacity Concealed Split Air Conditioning Machine along with 1 no. IDU of rated Cooling Capacity:- 18000 BTU/HR, Compressor:- Rotary Type, Remote Control:- Yes, Condenser Coil:- Copper, Refrigerant Type:- R-410A/R-32/R-22, Air Flow/IDU:- 600CFM, Operating Mode:- Cool & Fan Mode, Sleep Mode:- Yes, Timer:- Yes.
(Make:- Daikin/Voltas/Hitachi/O General) | 4 | Nos. | 58,000 ₹2.3 L | 52,600 ₹2.1 L | 52,700 ₹2.1 L | 56,800 ₹2.3 L | 52,850 ₹2.1 L | 57,600 ₹2.3 L | 58,000 ₹2.3 L | 54,900 ₹2.2 L |
| 3.00 | Installation, Testing & Commissioning of Indoor & Outdoor unit of the following capacity concealed type Split Air Conditioners after making hole in wall & necessary scaffolding arrangement etc as per site condition & direction of EIC including Supply of required Refrigerant as per the manufacturer specifications, S&F of necessary fixing arrangement for indoor duly painted etc as per direction of the EIC.
(a) 2 Tr. | 30 | Nos. | 6,500 ₹1.9 L | 2,500 ₹75,000 | 2,650 ₹79,500 | 5,000 ₹1.5 L | 2,690 ₹80,700 | 5,800 ₹1.7 L | 6,000 ₹1.8 L | 4,026 ₹1.2 L |
| 3.10 | (b) 1.5 Tr. | 4 | Nos. | 3,500 ₹14,000 | 2,500 ₹10,000 | 2,600 ₹10,400 | 5,000 ₹20,000 | 2,700 ₹10,800 | 5,800 ₹23,200 | 6,000 ₹24,000 | 3,592 ₹14,368 |
| 4.00 | Copper Refrigeration pipe line with 0.6 mm(min) & 0.7 mm (min) thick for liquid and suction line with fittings, elbows, bends, supports & brackets (Make-Ryoku/Totaline/Jobu/Nippon)
(a) Liquid Line (1/4" OD or as per manufacturer specification) | 340 | Mtrs. | 200 ₹68,000 | 205 ₹69,700 | 230 ₹78,200 | 290 ₹98,600 | 260 ₹88,400 | 250 ₹85,000 | 225 ₹76,500 | 112 ₹38,080 |
| 4.10 | (b) Suction Line (5/8" OD withor as per manufacturer specification) | 340 | Mtrs. | 445 ₹1.5 L | 365 ₹1.2 L | 375 ₹1.3 L | 498 ₹1.7 L | 389 ₹1.3 L | 498 ₹1.7 L | 425 ₹1.4 L | 250 ₹85,000 |
| 5.00 | Supply & Fixing Pipe Insulation in liquid & suction line with 9 mm nitrile rubber tube (Accoflex/Armacell/Supreme)
(a) Liquid Line (1/4" OD with 0.6 mm thick) | 340 | Mtrs. | 30 ₹10,200 | 32 ₹10,880 | 40 ₹13,600 | 75 ₹25,500 | 43 ₹14,620 | 70 ₹23,800 | 70 ₹23,800 | 24 ₹8,160 |
| 5.10 | (b) Suction Line (5/8" OD with 0.7mm thick) | 340 | Mtrs. | 35 ₹11,900 | 39 ₹13,260 | 41 ₹13,940 | 90 ₹30,600 | 46 ₹15,640 | 76 ₹25,840 | 70 ₹23,800 | 31 ₹10,540 |
| 6.00 | Supply and fixing of 4 X 2.5 Sq mm Control Cable, inside Precision make polythene pipe, with proper dressing, for the communication of IDU and ODU, as per Direction of E.I.C.
(Make: Gloster/Havells/Ploycab/ Finolex) | 340 | RM | 145 ₹49,300 | 105 ₹35,700 | 116 ₹39,440 | 198 ₹67,320 | 125 ₹42,500 | 169 ₹57,460 | 180 ₹61,200 | 226 ₹76,840 |
| 7.00 | S&F of 50 mm PVC Drain Pipe Line (50 mm OD, HD 1 mm Thick) with Insulation , Support & Bracket and other necessary arragnement for vertical run along the building including necessary scaffolding arrangement etc as per site condition & direction of EIC | 170 | RM | 205 ₹34,850 | 135 ₹22,950 | 148 ₹25,160 | 170 ₹28,900 | 156 ₹26,520 | 165 ₹28,050 | 160 ₹27,200 | 195 ₹33,150 |
Tender Value
₹29.0 L
EMD Value
₹58,088
Closing Date
25 Sept 2024, 4:00 pmClosed
EE,KNHED, PW Dte
THE EXECUTIVE ENGINEER, P.W.D /KOLKATA NORTH HEALTH ELECTRICAL DIVISION
Repair renovation of the Rest-rooms of On-call Junior Doctors / Sr. Residents / PGTs, including repair renovation of toilets for their comfortable Stay (Rattirer Sathi), at Surgery Bldg., Cardiology Bldg. and CTVS Bldg. of RG Kar MCH - SITC AC Work
2024_WBPWD_751987_1
WBPWD/EE/KNHED/e-NIQ-68/24-25
Open Tender
A/C ORG
7 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹58,088
Yes
17 Apr 2026
16 Sept 2024
27 Sept 2024
16 Sept 2024
25 Sept 2024
16 Sept 2024
stage.html
html • 0.06 MB
technical_1662183.pdf
techsummary_1662183.pdf
finance_1662183.pdf
BOQ Comparative Chart
xlsx
finsummary_1662183.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.57 MB
BOQ_1662183.xls
BOQ • 0.24 MB
2911.pdf
Tender Documents • 1.46 MB
suspension.pdf
Additional Documents • 2.91 MB
Download all tender documents and submit your bid