Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹72.8 LAccepted-AOC GP RAM COLONY AMRITSAR JALANDHAR 144103 | AMRITSAR | AMRITSAR | PUNJAB | 144103 | L1 | Accepted-AOC L1 | |
| 2 | L2₹75.9 L+₹1.4 L (1.89%)Rejected-Finance NEAR RAILWAY CROSSING ADAMPUR DOABA JALANDHAR JALANDHAR PUNJAB 144103 | JALANDHAR | PUNJAB | 144103 | L2 | Rejected-Finance Other than lowest. |
Tender Value
₹74 L
EMD Value
₹1.4 L
Closing Date
1 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Adampur
Military Engineer services Air Force Stn Adampur 144103
PROVN OF CERTAIN SANCTION WORKS IN TECH AND DOMESTIC AREA AT AF STN ADAMPUR
2022_MES_555896_1
GE/AF/ADM-33/2022-23
Open Tender
Civil Works
Item Rate
180 days
Tech and domestic area
Refer NIT and Tender Documents
9 documents required · 9 mandatory
₹1,000
GE AF Adampur
₹1.4 L
Yes
9 Dec 2022
4 Oct 2022
2 Nov 2022
4 Oct 2022
1 Nov 2022
19 Oct 2022
5 Oct 2022 - 18 Oct 2022
Amount
B/R WORKS
Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for foundation, etc. and getting out complete, all as specified.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, complete, all as specified.
Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
Hard core of broken stone or boulders of gauge n. exc. 63mm; deposited, spread and levelled in layers n. exc. 15cm thick watered and rammed to true surface complete all as specified.
PCC type E-2 (1:5:10), using 40 mm graded stone aggregates as in filling & mass concrete, sub base, complete all as specified.
PCC type C-2 (1:3:6), using 40 mm graded stone aggregates as in filling & mass concrete, sub base, complete all as specified.
Cement concrete (1:2:4) type B-2 using 40mm graded stone aggregate as in surface channel, coping and drain complete all as specified.
Cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in bed block of hold fast, coping including necessary form work etc complete all as specified.
Precast RCC type B-1 (1:2:4), using 20 mm graded stone aggregates landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including all mouldings but excluding frame, set in cement mortar (1:4) complete all as specified.
Forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement etc complete all as specified.
Reinforced cement concrete (1:1½:3) type A-1 (nominal mix) using 20mm graded stone aggregates as in lintels up to 1.5 metre clear span, bed blocks, copings and the like including weathering, slightly rounded or chamfered angles & throating including provision of necessary formwork, complete all as specified.
Reinforced cement concrete (1:1½:3) type A-1 (nominal mix) using 20mm graded stone aggregates as in as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified.
Brick work using bricks as specified in PS clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified.
Brick work using bricks as specified in PS clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:4), complete all as specified.
Brick work (except bricks) using old size bricks straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified.
Cutting chases pinning using mechenical means electric cutter in making good to facing where required for concealed water tubing in brick walls cutting n.exc 10 cm girth. complete all as specified.
Cutting holes into or through brick walls (upto 230 mm thick) built in cement mortar of superficial area not exceeding 150 Sq. cm and making good in cement mortar 1:3 or cement concrete 1:2:4, Type B-0 as required, complete all as specified.
Use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) with fair finished surfaces of concrete, complete all as specified.
Use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. with fair finished surfaces of concrete, complete all as specified.
Use & waste of formwork to edges of concrete flats and work; not exceeding 200 mm thick (Horizontal or sloping) with fair finished surfaces of concrete, complete all as specified.
Factory made 35 mm thick ,2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a);,etc complete all all as specified.
Factory made 2nd class hard wood rail and style, thicknesss of shutters,35 mm, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated,etc complete all all as specified.
Factory made, flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, 30 mm thick, ISI marked, complete all as specified.
Factory made solid PVC Door frame of size 50mm x 47mm made out of 5mm thick wood grain colour PVC sheet reinforced with mild steel square tube, suppling & fixing in opening, complete all as specified.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded wood grain PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheet for top rail, lock rail and bottom rail, panelling of wood grain colour PVC sheet to be fitted in the MS frame welded / sealed to the stile and rails with suitable PVC sheet beading and jointed together with solvent cement as specified in SSR Part II, complete all all as specified.
Factory made solid wood grain moulded door shutters, 28-30 mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2 mm thick plain colur PVC sheet on back face, as in cup boards & like, complete all as specified.
Aluminium anodised barrel tower bolt of extruded section 150mm long, ISI marked, complete all as specified.
Aluminium anodised barrel tower bolt of extruded section 125mm long, ISI marked, complete all as specified.
Stainless steel butt hinges100mm long, ISI marked, complete all as specified.
Stainless steel butt hinges 75 mm long, ISI marked, complete all as specified.
Extruded aluminium anodised handles fabricated type with plate 125 mm long, ISI marked complete all as specified.
Extruded aluminium anodised handles fabricated type with plate 150 mm long, ISI marked complete all as specified.
Aluminium alloy, anodised, ISI marked sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy 250mm long, complete all as specified.
Mild steel helical door spring 200mm, ordinary rat tail rod pattern including roller and roller plate ISI marked, complete all as specified.
Hasp and staple, safety type, aluminium anodised including bolt to hinge plate and fixed with screws of size 100 mm, ISI marked complete all as specified.
Double leg aluminium anodised door stopper with rubber foot, ISI marked and fixed with steel screws to bottom rail of doors complete all as specified.
Stainless steel conduit 20-25 mm bore, cut to size and erected in position including provison SS brackets & PVC decorative type finials (Two nos for each opening) IN REPAIRS, complete.
Galvanised steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks or galvanised wire staples all as specified.
Galvanised steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks or galvanised wire staples, IN REPAIRS, complete all as specified.
Framed mild steel work such as grills, grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings and similar work confirming to Fe-290-Gde E-165, IN REPAIRS, complete all as specified. NOTE: Grill shall be factory fabricated and supplied duly welded to window frame with shop coat of red oxide primer.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
Mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
Pressed steel frames made out mild steel sheet 1.25 mm thick, for doors with one or more rebates including necessary fixing lugs, 100 mm size butt hinges ISI Marked, lock strike plates etc and applying a shop coat of red oxide primer including providing PCC (1:3:6) type C-0 using 12.5 mm graded crush stone aggregate for filling back of chowkhats complete all as specified for size of frame: -
105 mm x 60 mm
125 mm x 60 mm
Factory made steel windows with side hung shutter with glazing bars each shutter having 02 No. box type hinges & two nos. tower bolts of size not less than 150 mm size and peg stays, dovetailed or welded, including one shop coat of zink chromate primer complete.
Factory made steel windows with side hung shutter without glazing bars each shutter having 02 No. box type hinges & two nos. tower bolts of size not less than 150 mm size and peg stays, dovetailed or welded, including one shop coat of zink chromate primer complete.
Steel windows or ventilators, fixed type including one shop coat of zink chromate primer complete.
NOTES APPLICABLE TO SERIAL ITEM NO. 45 TO 47: Profile section used under these items shall be 'P' tube as shown in drawing No. CE/AF/STD-170/07, CE/AF/STD-171/07 and CE/AF/STD-172/07 as applicable.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm of any colour hving tensile strength of 550 Mpa as in roof coverng/cladding to wall, fixed with self tapping screws, IN REPAIRS, complete all as specified.
Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm of any colour hving tensile strength of 550 Mpa as in roof coverng/cladding to wall, fixed with self tapping screws, IN REPAIRS, complete all as specified.
Water Proofing Treatment to RCC sunken surfaces comprising of : -
Rendering 15 mm thick (Average thickness) rendering on sunken surfaes including flashings, finished even and fair in cement mortar (1:4), using water proofing compound as per recommended ratio, after brushing cement slurry @ 1.20 kg/Sq. m, complete all as specified.
LDPE sheet 150 micron laid over applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq. m & adjoining vertical surfaces including applying bitumenous primer @ 0.40 litre per square metre over clean RCC/plastered roof surfaces complete all as specified.
NOTES: (a) Supply only WPC will be measured and paid for separately under respective item of BoQ. (b) For Guarantee of Water Proofing Treatment refer PS clause 11.5 of CA.
Supply only water proofing compound (WPC), ISI marked, complete all as specified.
uPVC pipes, 110 mm external dia pipe, type-A, ISI marked (IS:13592) single socketed in any length with rubber ring joints, fixed to wall with PVC brackets as rain water pipes, IN REPAIRS, complete all as specified
25 mm thick, cement concrete type B-0, 1:2:4 using 12.5 mm graded stone aggregate, finished rough, as in sub floors or similar locations, complete all as specified.
75 mm thick, cement concrete type C-1, 1:3:6 using 20 mm graded stone aggregate, finished even & smooth without using extra cement, as in plinth protection, and joints shall be sealed with joint sealing comound grade 'A' complete all as specified.
75 mm thick, cement concrete type D-2, 1:4:8 using 40 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified.
Machine cut Kota stone slab flooring 18-22 mm thick, for staircase step in single piece (of length not more than 1200 mm), laid over over & including 20 mm thick (average thickness) cement mortar (1:3) screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (Granite finish) complete, all as specified.
Machine cut Kota stone slab flooring 18-22 mm thick, for staircase riser in single piece (of length not more than 1200 mm), laid over over & including 15 mm thick (average thickness) cement mortar (1:3) screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (Granite finish) complete, all as specified.
Granite jet black shade, 15-18 mm thick,as in step, jambs, cooking platform and like, machine cut, machine polished, bedded and jointed with grey cement slurry & pointed with grout of matching shade including necessary cutting over making hole as required & including 10 mm thick (average thickness) cement mortar (1:4), complete all as specified.
Rounding of / moulding to edges (half round) of stone of any description including rubbing and polishing (Granite finish), complete all as specified.
Glazed ceramic coloured tiles 7mm thick, area of each tile exc. 0.17 Sq.m but n. exc. 0.19 Sq.m, on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in grout of shade matching to tile laid over and including 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified.
Non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exc. 0.06 Sq.m but n. exc. 0.11 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed in grout of shade matching to tile laid over and including 15 mm thick bedding layer in cement mortar (1:4) including necessary cutting and waste as per site requirement complete all as specified.
Non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exc. 0.18 Sq.m but n. exc. 0.38 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed in grout of shade matching to tile laid over and including 15 mm thick bedding layer in cement mortar (1:4) including necessary cutting and waste as per site requirement complete all as specified.
Non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exc. 0.18 Sq.m but n. exc. 0.38 Sq.m, on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in grout of shade matching to tile laid over and including 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified.
Factory made, machine pressed precast concrete interlocking paver block any shape and size approved by EIC, ISI marked (IS:15658-2006) of 60 mm thick, M-35 grade, with grey cement & pigment, laid dry in paths / roads & including over 25 mm thick consolidated thickness clean dry sand, complete all as specified.
Cutting out natural vegitation plants grown up on walls/roofs and making good the damaged portion to match with the existing surface to the entire satisfaction of Engineer-in-Charge, complete.
Rendering 5 mm thick on fair faces of concrete surfaces, finished fair and even on ceiling surfaces in cement mortar (1:3), complete all as specified.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:6) complete all as specified.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), mixed with water proofing compound as per manufacturers instructions, complete all as specified.
Repairinging of damaged swollen RCC surfaces like projections chhajjas, facia, parapet etc including necessary scraping, cutting, chiseling, derusting and cleaning exposed reinforcement, washing apply cement slurry @ 3 kg/Sq.m and fiishing the surface with cement concrete (1:1.5:3) using 12.5 mm graded stone aggregate incl reinforcement with chicken wire or welded mesh having weight not more than 3 kg/Sq.mm as reinforcement with and/or finished the repaired surface with cement and sand mortar (1:3) using WPC and work in patches area n.exc 5 Sq.m incl necessary formwork complete all as specified. NOTE:Quoted rate shall includes the cost of scaffolding/shuttering upto 15 metre height.
NOTE APPLICABLE FOR SERIAL ITEM 67 & 68: Supply only water proofing compound (WPC) will be easured & paid separately uder respective item of BoQ.
Applying one coat of white wash on ceiling and preparation of old plastered or un-plastered surfaces complete all as specified.
Three coats of white washing on new plastered ceiling surfaces, including preparation of surfaces, complete all as specified.
Three coats of white washing on new plastered wall surfaces, including preparation of surfaces, complete all as specified.
Prepration of new plasterd wall surfaces of any description complete all as specified and applying the following: - (a) Applying wall care putty, in two coats & smoothening the surfaces as specified. (preparatory to paint as directed). (b) Two coats of interior acrylic distemper/oil bound distemper over and including a coat of interior primer
Complete removal of existing treatment of any description, including prepration of wall surfaces of any description complete all as specified and applying the following: - (a) Applying wall care putty, in two coats & smoothening the surfaces as specified. (preparatory to paint as directed). (b) Two coats of interior acrylic distemper/oil bound distemper over and including a coat of interior primer.
Prepration of new plasterd wall surfaces of any description complete all as specified and applying the following: - (a) Applying wall care putty, in two coats & smoothening the surfaces as specified. (preparatory to paint as directed). (b) Two coats of exterior acrylic emulsion over and including a coat of water based exterior primer.
Complete removal of existing treatment of any description, including prepration of wall surfaces of any description complete all as specified and applying the following: - (a) Applying wall care putty, in two coats & smoothening the surfaces as specified. (preparatory to paint as directed). (b) Two coats of exterior acrylic emulson over and including a coat of water based exterior primer.
NOTES APPLICABLE TO SERIAL ITEM NO. 72 TO 75: (i) Entire quantity of material for this work shall be procured by the contractor from manufacturer's Depot & deposit the same with Enginer-in-Charge and same shall be issued to contractor on daily basis as per consumption at site. (ii) The work shall be got executed through paint manufacturer/ authorised applicators of manufacturer's as specified in relevent PS clause.
Sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beads in squares n. exc. 0.5 Sq.m in each pane including hacking out old broken glass (any thickness, size, quality or description) from wooden/ metal frame including punching or drilling out old glazing pins/spring clips complete all as specified.
Sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beads in squares n. exc. 0.5 Sq.m in each pane complete all as specified.
Figured glass, 4 mm thick, pin head type and glazing with linseed oil pane putty & spring glazing clips, in squares exceeding 0.5 sq. m in each pane, complete all as specified.
Two coats of synthetic enamel paint over & including a coat of pink primer over wood and wood (new) based surfaces of any description not other wise described over 10cm width or girth including preparation of surfaces complete all as specified.
Two coats of synthetic enamel paint over & including a coat of red oxide primer over steel & iron (new) surfaces of any description, not otherwise described, over 10 cm in width or girth, including preparation of surfaces complete all as specified.
Steel tubes ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors , of size: -
15mm bore
20mm bore
500 litre capacity, white, three layered polyethylene water storage tanks (cylindrical vertical with closed top) including hoisted and fixed in position, making connections, IN-REPAIRS, complete all as specified including the following acessories: - (i) Brass ball valves, high pressure, with GI rod & high density plastic ball complete screwed for iron pipe or brass ferrule and fixed, suitable for 20 mm bore GI pipe, IN REPAIRS, complete all as specified. (iii) Gun-metal stop valve (quarter turn type) with MS lever handle, suitable for GI tubes 20 mm bore, ISI marked, screwed both ends for iron pipe, IN REPAIRS, complete all as specified. (iv) Provn of 20 mm bore GI light grade tube from O/H tank to nearest mouth of RWP.
500 litre capacity, white, three layered polyethylene water storage tanks (cylindrical vertical with closed top) including hoisted and fixed in position, making connections, complete all as specified including the following acessories: - (i) Brass ball valves, high pressure, with GI rod & high density plastic ball complete screwed for iron pipe or brass ferrule and fixed, suitable for 20 mm bore GI pipe, complete all as specified. (iii) Gun-metal stop valve (quarter turn type) with MS lever handle, suitable for GI tubes 20 mm bore, ISI marked, screwed both ends for iron pipe, complete all as specified. (iv) Provn of 20 mm bore GI light grade tube from O/H tank to nearest mouth of RWP.
Angular stop valve/cock, cast copper alloy, chromium plated, with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE: PRAYAG Cat No. 6810 or equivalent make mentioned in Appndix 'B'.
Concealed stop valve/cock, cast copper alloy, chromium plated, with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE: PRAYAG Cat No. 6818 or equivalent make mentioned in Appndix 'B'.
Bib tap, cast copper alloy, chromium plated fancy type, long body with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE: PRAYAG Cat No. 6808 or equivalent make mentioned in Appndix 'B'.
Centre hole basin mixer, swan neck type, cast copper alloy, chromium plated, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE:PRAYAG Cat No. 6850 or equivalent make mentioned in Appndix 'B'.
100 mm size overhead cross flow ABS shower with cast copper alloy chromium plated arm 150 mm long with flange and fixed in position, IN REPAIRS, complete. MAKE:PRAYAG Cat BOS-100 or equivalent make mentioned in Appndix 'B'.
Stainless steel towel rail 600 mm long, fixed to wall with SS screws and PVC rawl plugs, IN REPAIRS, complete. MAKE: PRAYAG Cat No.BA-10S or equivalent make mentioned in Appndix 'B'.
Stainless steel towel rail 600 mm long, fixed to wall with SS screws and PVC rawl plugs, complete. MAKE: PRAYAG Cat No.BA-10S or equivalent make mentioned in Appndix 'B'.
PVC connections 15 mm size of length 450 mm with PTMT nuts, complete all as specified.
PVC connections 15 mm size of length 450 mm with PTMT nuts, IN REPAIRS complete all as specified.
Glass shelf 300 mm long fixed with and including steel screws and plugs IN REPARS, complete all as specified. MAKE: PRAYAG Cat No.BEA-49 or equivalent make mentioned in Appndix 'B'.
Stainless steel (304 grade) grating with frame, with or without hole 100-110 mm size, complete all as specified.
Stainless steel (304 grade) grating with frame, with or without hole 100-110 mm size, IN REPAIRS, complete all as specified.
Vitreous china wash down water closet pan (pedestal pattern), ISI marked, white with uPVC 'S' trap of size 540x365x390 mm complete all as specified. MAKE: PRAYAG Cat No. 4016 or equivalent make mentioned in Appndix 'B'.
Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm, ISI marked, white, with integral foot rests (excluding flushing cistern and flush pipe), IN REPAIRS, complete all as specified.
PVC flushing cistern 10 litre capacity, dual flush syphonic action type, any shade, with side handle, ISI marked (IS: 7231) with flush pipe and all fixing arrangements,complete all as specified.
PVC flushing cistern 10 litre capacity, dual flush syphonic action type, any shade, with side handle, ISI marked (IS: 7231) with flush pipe and all fixing arrangements, IN REPAIRS, complete all as specified.
Vitreous China wash basin, white, flat back, size 550 x 400 mm ISI marked, complete all as specified. including fixing acessories like rag bolts etc. with PTMT waste coupling half or full threaded suitable for & including 32 mm size PVC discharge pipe, complete.
Vitreous China wash basin, white, flat back, size 550 x 400 mm ISI marked, complete all as specified. including fixing acessories like rag bolts etc. with PTMT waste coupling half or full threaded suitable for & including 32 mm size PVC discharge pipe, IN REPAIRS, complete.
Stainless steel sink, single bowl with drain board, made out of SS-304 sheet not less than 1 mm for kitchen with & including plug waste pipe, washers connecting union etc including necessary fixing acessories, overall size 1143x510mmx203 mm with bowl size 510mm x 405mm x203mm IN REPLACEMENT, complete. MAKE: PRAYAG Cat 1352D or equivalent make mentioned in Appendix 'B'.
Stainless Steel (SS-204) kitchen plate rack of sheet thickness not less than 0.61 mm overall size 786 x 760 x 254 mm, fixed on walls wth PVC plugs and SS screws, IN REPLACEMENT, complete. MAKE: PRAYAG Cat No. P-446 or equivalent make mentioned in Appndix 'B'.
PTMT bib tap suitable for 15 mm bore tube complete.
PTMT pillar tap suitable for 15 mm bore tube complete.
PTMT stop valve suitable for 15 mm bore tube complete.
uPVC pipes, type-B, ISI marked (IS:13592) single socketed in any length with rubber ring joints, fixed under floors / fixed to wall as SWR pipes, complete all as specified of size: -
75 mm bore
100 mm bore
uPVC pipes, type-B, ISI marked (IS:13592) single socketed in any length with rubber ring joints, fixed under floors / fixed to wall as SWR pipes, IN REPAIR, complete all as specified of size: -
75 mm bore
100 mm bore
uPVC/PVC bends any radius, complete all as specified. suitable for uPVC soil waste discharge pipes, of size: -
75 mm bore
100 mm bore
uPVC/PVC bends any radius, complete all as specified. suitable for uPVC soil waste discharge pipes, IN REPAIR, of size: -
75 mm bore
100 mm bore
uPVC/ PVC branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches or 'T' piece with oval acess door, ISI marked, suitable for uPVC/ PVC pipe of size 75 mm bore, IN REPAIRS, complete all as specified.
uPVC/ PVC branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches or 'T' piece with oval acess door, ISI marked, suitable for uPVC/ PVC pipe of size 100 mm bore, IN REPAIRS, complete all as specified.
uPVC/PVC vent cowl 75-110 mm external dia, complete all as specified.
uPVC/PVC vent cowl 75-110 mm external dia, IN REPAIR complete all as specified.
100 mm uPVC/PVC sanitary connection socket to fit WC out-let, IN REPAIRS, complete all as specified.
100 mm uPVC/PVC sanitary connections short connections pipe of length upto 300 mm, IN REPAIRS, complete all as specified.
uPVC / PVC 75 mm bore floor trap including jointing with solvent and embedding in cement concrete type B-1 (1:2:4) complete all as specified of size: -
uPVC / PVC floor trap including jointing with solvent and embedding in cement concrete type B-1 (1:2:4) IN REPAIR complete all as specified of size: -
75 mm bore
100 mm bore
uPVC / PVC 110mm bore junction single ( Single T) equal or unequal complete all as specified of size: -
Concrete bed to drain pipes 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 type C-2, complete all as specified.
Reinforced concrete pipes 150 mm bore, class NP-2, laid and jointed complete with collars, laid in trenches and jointed, ISI marked, complete all as specified.
Cutting into existing manholes for connecting new drains, of 150 mm bore pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1, smooth finished, reforming benching as required, complete all as specified.
E/M WORKS
Point wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed FRLSH cable, including PVC insulated unsheathed multi stranded copper conductor single core FRLSH cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes with 3 mm thick plastic laminated sheet cover having necessary cutting for fixing switches/ sockets comprising the following: -
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified.
One light point controlled by two 2 way switches with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified.
One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified.
One Socket outlet, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC heavy duty concealed conduit not less than 20mm dia all as specified.
One socket outlet, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified.
NOTES: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. (b) GI boxes shall be fixed flush to walls in position with cement mortar (1:4) complete all as directed. (c) Conduit shall be laid on surface in case of RCC ceiling surfaces.
Switch piano flush button single pole one way, 6 Amp complete all as specified.
Switch piano flush button single pole two way, 6 Amp complete all as specified.
Switch piano, bell/buzzer push, flush button single pole one way, 6 Amp complete all as specified.
Switch piano flush button single pole one way, 16 Amp complete all as specified.
Socket outlet multipurpose having provision for 2&3 pin, 6 Amp, flush type, complete all as specified.
Socket outlet multipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp, flush type complete, all as specified.
Ceiling rose, surface bakelite, 65 x 50mm, three terminals complete, all as specified.
Lamp (angle) holder, insulated body, cord grip pattern, complete, all as specified.
Electric buzzer AC 230 volt, Ding Dong type complete, all as specified.
Fan regulator (electronic) suitable for 48”/56” sweep fan, double switch stepped type, single phase, complete all as specified.
Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated multi stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLSH PVC insulated flexible stranded copper conductor 1.1 KV grade for earthing in conduits, complete all as specified for the following: -
2 runs of 4 Sq. mm main cable + 1 run of 4 Sq. mm earth cable
2 runs of 6 Sq. mm main cable + 1 run of 6 Sq. mm earth cable
NOTES: (i) Conduit & conduit accessories shall be measured & paid for separately. (ii) For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as "1 RUNNING METRE"
Rigid non metallic, PVC concealed conduit ot less than 20 mm bore, medium grade, ISI marked, inclusive of all fitings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing acessories such as couplers, lock nuts, saddles, pipe hook etc. for sub main wiring and the like complete all as specified.
Sheet metal enclosure SPN, 4 way with 200 Amp rated bus bar, 240 V, double door DB for fixing MCB’s, isolators etc., having IP-43 protection, surface and flush mounting, complete all as specified.
Sheet metal enclosure SPN, 12 way with 200 Amp rated bus bar, 240 V, double door DB for fixing MCB’s, isolators etc., having IP-43 protection, surface and flush mounting, complete all as specified.
Sheet metal enclosure TPN, 4 way with 200 Amp rated bus bar, 415 V, double door DB for fixing MCCB, MCB’s, isolators etc., having IP-43 protection, surface and flush mounting, having housing & including 63 Amp 4 pole MCCB complete, all as specified.
MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp complete all as specified.
MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp complete all as specified.
Blanking plate to cover unused space in DB's complete all as specified..
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 volt, breaking capacity not less than 10 kA, complete all as specified.
XLPE insulated heavy duty multi stranded armoured and PVC sheathed power cable 10 Sq.mm, 2 core,1100 volts grade with aluminium conductor laid in ducts/ along poles/ through pipes including laying, jointing and testing complete all as specified
Earthing with and including GI earth plate electrode 6 mm thick of size 600 mm x 600 mm with 4 Sq. mm GI wire earthing lead including test point complete all as shown in electrical plate No. 3 and specified in Particular Specifications clause 19.4 of contract, NOTE: (a) The unit rate includes earthing lead and protection pipe upto 7.5 metre from top of earth plate. (b) Factory made precast PCC pit with cover shall be fixed at least 500 mm away from earth pit.
Earthing with and including GI earth plate electrode 6 mm thick of size 600 mm x 600 mm with 4 Sq. mm GI wire earthing lead including test point complete all as shown in electrical plate No. 3 and specified in Particular Specifications clause 19.4 of contract, IN REPAIR. NOTE: (a) The unit rate includes earthing lead and protection pipe upto 7.5 metre from top of earth plate. (b) Factory made precast PCC pit with cover shall be fixed at least 500 mm away from earth pit.
Envirnment friendly, energy saving surface mounted, decorative 6.5 W bulk head LED luminaire with premium quality diffuser for glarefree light, 6000K complete. MAKE: Havells Cat Part No. LHEXCGP7ION5W006 or equivalent in makes mentioned in Appendix 'B' here-in-after.
Surface mounted envirnment friendly decorative ultra slim profile LED 10 W lighting fixture with extruded polycarbonate, 6500K, lumen output should not be less than 90 lumens per watt complete. MAKE: Havells Cat Part No. LHEXACP7PN1W010 or equivalent in makes mentioned in Appendix 'B' here-in-after.
Surface mounted envirnment friendly decorative ultra slim almn LED 22 W lighting 6500K, lumen output should not be less than 90 lumens per watt complete. MAKE: Havells Cat Part No. LHEXBTP7IN1S022 or equivalent in makes mentioned in Appendix 'B' here-in-after.
Exhaust fan 300 mm sweep, steel body,heavy duty with louvers and connecting up complete from ceiling rose or connector to fan, complete all as specified.
Disconnectiing & taking down water storage geyser 25-50 litre from existing location and refixing & reconnecting the same on orginal or new location after misc service and including all fixing aceeessories as required at site complete.
Galvanised iron light grade 25 mm bore tubes laid in trenches as protection pipe, IN REPAIRS, complete all as specified. NOTE: Excavation & earthwork will be measured and paid for separately under respective item of BoQ.
DEMOLITION/DISMANTLING WORKS
Taking down cement plaster of any description on brick walls or concrete surfaces etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sq.m each and removing from site all as specified.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 Sq.m but not exceeding 4.00 Sq.m each and removing from site all as specified.
Taking down shutters of any description exceeding 1.00 sqm but not exceeding 2.00 sqm each and refixing in the same opening after easing adjusting and minor REPAIRS complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding and removing rubbish off the premises complete all as specified.
Demolition of stone slabs of any description, laid, bedded and pointed in any mortar complete all as specified.
Demolition brickwork or stone / boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified.
Demolition of cement concrete (unreinforced) in ground floors and pavings not excceding 15cm thickness (above or below ground level) all as specified
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided all as specified.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided all as specified.
Taking down steel water tubes and connection including cleaning for refixing or removal to store complete, all as specified of following size:-
15mm bore
20mm bore
Demolition and breaking up drain pipes 150 bore (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, including PCC bedding as required and haunching, complete all as specified
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete with batten, casing caping of MS or and PVC conduit on surface or concealed, including switches, ceiling roses, pendants, regulators, sockets, mild steel terminal boxes etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified.
Taking down carefully copper/aluminium sub main wiring complete, including existing batten/conduit consealed/surface etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified.
Dismantling of unservisible existing DBs of any description with all accessories and MCBs, isolators etc. and making good surface as per existing, complete all as specified.
Taking down carefully light fitting of any description, complete all as specified.
Taking down carefully electric bell/buzzer of any description, complete all as specified.
NOTE: Amount of credit for retrieved materials is mentioned in tender documents in pdf form which will be deducted while acceptance of tender offline.
M/S GURBACHAN SINGH
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .