| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.3 LAccepted-AOC 01 PATHWALIYA GONDA GONDA GONDA UTTAR PRADESH 271001 | GONDA | UTTAR PRADESH | 271001 | L1 | Accepted-AOC Being a lowest bidder and reasonable | |
| 2 | L2₹45.7 L+₹3.2 L (7.64%)Rejected-Finance 121004 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹52.7 L+₹10.2 L (23.9%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹53.4 L+₹10.9 L (25.6%)Rejected-Finance PO CHANDL PS BISHNUPUR DIST SOUTH 24 PGS PIN 743503 | 24 PARAGANAS SOUTH | WEST BENGAL | 743503 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹53.4 L+₹10.9 L (25.8%)Rejected-Finance 8 27 BEJOYGARH JADAVPUR KOLKATA 700 032 | KOLKATA | WEST BENGAL | 700032 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
22 Jan 2025, 6:00 pmClosed
Garrison Engineer Vijay Durg (Erstwhile FW) Kolkat
D9 Commissariat Road Hastings Kolkata 700022
SPL REPAIR TO BER AC, CEILING FANS AT DIFFERENT MD ACCN AT FORT WILLIAM UNDER GE VIJAY DURG (ERSTWHILE FW) KOLKATA
2025_MES_691530_1
8371/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer Vijay Durg (Erstwhile FW) Kolkat
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer Vijay Durg (Erstwhile FW) Kolkat
₹76,000
5 Apr 2025
2 Jan 2025
23 Jan 2025
2 Jan 2025
22 Jan 2025
15 Jan 2025
Amount
Taking down carefully the existing aluminium/copper point wiring of any size and capacity and type by disconnecting from the either terminals complete including fittings and fixtures such as switches, sockets, ceiling rose, fan regulators, lamp holders, call bell, bell pushes any type etc by unscrewing and taken away from site complete and make good the disturbed surface as existing.
M & L for point wiring with 1.5 sqmm (Nominal Area) FRLS PVC insulated un sheathed multi stranded copper conductor, 1100 Volts grade, in and including PVC casing capping/conduit (ISI marked) with accessories such as bends, cross, elbow, tees etc. of suitable size including MS pressed steel cadmium plated terminal box not less than 1.6 mm thick for mounting switches, sockets, fan regulators etc and 3 mm thick laminated sheet top cover(ISI marked) including continuous earth wire FRLS PVC insulated unsheathed 1.5 Sq mm(nominal area) copper multistarnded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified for one light point/Exhaust fan/ceiling fan/ call bell point point controlled by one switch Note : Wiring Color code i.e. Red/Yellow/Blue for Phase, Black for neutral and Green for earth shall be maintained.( for concealed wiring chase cutting will be measured and paid separately.)
Material & labour for Sub main wiring with two runs of single core 4 Sqmm (Nominal Area) FRLSH PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 volts grade drawn through and including PVC casing capping of adequate size fixed on surface of wall/ceiling with all necessary fittings and accessories and 1 run of FRLSH PVC insulated and unsheathed insulated single core cable with multi standered copper conductor of size 4 Sqmm as earth wire (green in colour) run through casing capping and connected common earth dolly including taking out the old sub main wiring for connection to DBs/dolly shall be deemed to be included in this item and shall be measured as one run complete all as specified and directed.
S&F Switch piano flush type single pole one way 5A SP 230 Volts complete all as specified and directed.
S&F Ceiling rose surface type 3 terminals 65x20mm complete all as specified and directed.
S&F Fan Regulator electronic stepped type, 230 volts complete all as specified and directed.
Supply and fix MCB SP 240V, 6-32 Amps capacity complete all as specified and directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity 40 to 63 AMP in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S&F sheet metal enclosure of Bus bar of SPN 8 way complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods and accessories, alongwith PVC flexbile pipe from ceiling rose to connector input voltage 165-285 V ,28W 1200 mm sweep, 360 RPM, Min air delivery 220 M3/Min CFM with LED indication for speed, class F insulation, service value 6.00 BEE, of 5 years on site warranty for all defects like winding/motor/PCB and remote with step speed control remote , Five star rated with brushless direct current motor (BLDC) including taking down of old unsv ceiling fans from same or different locations. Note:- Contractor will submit the old ceiling fan obtanied from site to RRC complaint cell and same cost is deemed to be included in the mentioned rate. Any minor items like connector, pvc flexible pipe, clips ete. which is not included in BOQ, needed for installation of ceiling fans if required on site is deemed to be included in the quoted rate as well.
GHOSH ENTERPRISE (BID ID -3220329)
JOY-EN-JOY (BID ID -3220609)
UNITED ENGINEERS (BID ID -3219993)
MAZUMDER ENTERPRISE (BID ID -3221400)
DEB AND COMPANY (BID ID -3217955)
SHEIKH ENTERPRISE (BID ID -3221025)
ARJUN DAS VALECHA (BID ID -3220781)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .