Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC NO 18 8 254 26 RAKSHAPURAM SAIDABAD POST HYDERABAD 500 005 | HYDERABAD | HYDERABAD | TELANGANA | 500005 | ₹1.6 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹1.9 Cr+₹27.5 L (16.7%)Rejected-Finance FLAT NO 03 PANCHAVATI BUILDING ADARSH NAGAR CHICALIM GOA 403711 | SOUTH GOA | GOA | 403711 | ₹1.9 Cr+₹27.5 L (16.7%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹1.9 Cr+₹29.5 L (17.9%)Rejected-Finance | ₹1.9 Cr+₹29.5 L (17.9%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹2.0 Cr+₹32.9 L (20.0%)Rejected-Finance NO 16 7 739 3RD FLOOR OSMANPURA CHADERGHAT HYDERABAD TELANGANA 500 024 | HYDERABAD | HYDERABAD | TELANGANA | 500024 | ₹2.0 Cr+₹32.9 L (20.0%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹2.0 Cr+₹39.4 L (23.9%)Rejected-Finance | ₹2.0 Cr+₹39.4 L (23.9%) | L5 | Rejected-Finance Not being L1 |
Tender Value
₹1.9 Cr
EMD Value
₹2.6 L
Closing Date
4 Sept 2024, 6:00 pmClosed
Chief Engineer AF Bangalore
Chief Engineer AF Bangalore No. 2 DC Area MES Road Yeshwantpur Post Bangalore 560022
PROVN OF COMMERCIAL POWER SUPPLY TO MPR AT AFS HAKIMPET
2024_MES_653748_1
801606/E8
Open Tender
Civil Works
Lump-sum
540 days
Hakimpet
As per NIT
8 documents required · 8 mandatory
₹1,000
GE (AF) HAKIMPET
₹2.6 L
Yes
30 Sept 2024
13 May 2024
11 Sept 2024
13 May 2024
4 Sept 2024
15 Jul 2024
14 May 2024 - 21 May 2024
Amount
GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to IX are prepriced by MES under Ser Nos. 2.00 to 10.00. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for “Building or works” as listed in Schedule ‘A’ Part - I inserted by MES .
Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’ Part - II inserted by MES .
Lumpsum price worked out by the contractor for “Internal Electric Supply” as listed in Schedule ‘A’ Part - III inserted by MES .
Lumpsum price worked out by the contractor for “Site Clearance” as listed in Schedule ‘A’ Part - IV inserted by MES .
Lumpsum price worked out by the contractor for “Path” as listed in Schedule ‘A’ Part - V inserted by MES .
Lumpsum price worked out by the contractor for “External Water Supply ” as listed in Schedule ‘A’ Part - VI inserted by MES .
Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part -VII inserted by MES .
Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part -VIII inserted by MES .
Lumpsum price worked out by the contractor for “Cable Duct ” as listed in Schedule ‘A’ Part -IX inserted by MES .
Schedule ‘A’ Parts X is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6.
Schedule 'A' Part - X :(MISC ITEMS) External w/s/External E/S Boring/drilling (horizontally) of holes under road,pavement,hard standing by trenchless technology using ultra sounding technique and necessary machine including provision of HDPE pipe of 80 mm dia suitable for 0.40 mpa working pressure or manually complete all as specified and as directed.
Supply, Installation,testing and commissioning of 11 KV Compact Sub Station with non extensible RMU suitable for Out door use consisting of 1 No manually operated 11 KV/630 Amps VCB in SF6 insulated stainless enclosure,HT Cable/Bus bar ,1 No transformer 315 KVA,11KV/433 CRT dry type & associated LT devices (ACB/MCCB/bus bar/Cable) with the following details of components(as given in srl no 14 to 16) cost of which of which are deemed to be included in the rate quoted by the contractor:-
HT Section :- RMU-NON-Extensible 1 way, 11KV, 1 SF6 circuit breaker along with connected accessories etc. Type: - Free Standing, Metal Clad, SF6 insulated Ringmaster with 01 no. Direct Cable Module & 01 no. 630A Fixed Manual SF6 Circuit breaker- Model DV or Eq. (a) Self Powered Relay, Type IDMT (b) Ring Switches and T OFF SF6 circuit breaker with Integrated Earthing Switches (c) Live Cable Indicator for Ring Switches Provided (d) Padlocking facility-Provided (e) Shunt trip coil rating – 230V AC (f) Padlocking facility. (g) Current Transformer –Cast resin Ratio: 100/5-5A, Core1:Cl.0.5, 2.5VA, Core2:Cl.5P10, 2.5VA. (h) Numerical 2OC + 1EF Relay (j) Indication lamps for VCB off / on / auto trip/ Trip circuit healthy/ spring charge indication.
Transformer Section :- (a) 315 KVA, 11/0.433 KV, Copper Wound Dry Type Cast Resin Step Down Transformer (5 Position having Off Circuit Tap Links of +5% in steps of 2.5% each) with all standard fittings & accessories including Digital Type WTI with Alarm & trip contacts & RTD Sensors as per IS-1180 (Part-1/2014)/I. (b) Temperature Scanner with RTD sensor.
LT Section :- (a) LT Panel comprising of LV Side Incomer -500 Amp, 4Pole 35KA MCCB with adjustable thermal and magnetic based release with O/L & S/C protection. (b) MS Steel Sheet enclosure suitable for Outdoor Installation with MS channels (Base) (c) Provision for receiving Incoming cables through Bottom entry and out going through Bus bar to Transformer panel, excluding Termination Kit & Glands. (d) 500A/5A Cl:1.0 CT Ratio – 500/5A. (e) Space Heater with ON/OFF Switch and Thermostat, Single phase switch with socket, LT Cubical illumination Lamp with Door Limit switch and MCB’s for AC / DC Control.
Material and Labour for earthing pit display boards made out of 3mm thick MS sheet of size 30 x 35cm welded to 75cm long 25 x 25 x 5 mm thick MS angle iron grouted in PCC (1:3:6) (using 20mm graded crushed stone aggregate) to a depth of 20 cm and applying two coats of synthetic enamel paint of approved color over a coat of red oxide primer and writing the letters on plate for showing the following details: 1. EARTHING PIT NO : 2. DATE OF MEASUREMENT : 3. NEXT DUE DATE : 4. STANDARD VALUE : 5. VALUE OBTAINED : 6. MEASURED BY : 7. SUPERVISED BY : Note : Shape, size and colour of display board should be approved by Engr in Charge before fixing at site.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade complete all as specified and as directed.
Supply and Laying of Rubber mat of 1 meter x 2 meter x 19 mm suitable for 11 KV electric insulation, ISI Marked complete all as specified and directed.
BLANK
Supply and Installation, Testing and commissioning of Isolation Transformer 300 KVA, Input voltage/Output voltage 415 Volts, 3 Phase :- (a) Related Standards : IS 2026, IS-11171 (b) Input Voltage and Output Voltage : A)1:1, B) 1:2, C) Customized (c) Efficiency @ 100% Load : <97.5% (d) Regulation : 2-4% from 0.8 to unity power factor (e) Impedence : <4% (f) Connection : Delta/Star* (g) Vector Group : Dyn 11**for Delta/Star (h) Operating Load Power Factor : 0.75 Lagging to 0.75 Leading (j) DC Galvanic Isolation : >500 Mega Ohms (k) Dielectric strength : 2.5 KV, 50 Hz for One Minute (l) Coupling Capacitance : 0.1 Pico Farads (m) Line Leakage Current : < 20 Micro Amps (n) Noise Attenuation ; 100 DB upto 10 Khz (o) Operating Temparature : 0 to 45* C (p) Insulation : Class F (q) Degree of Protection : IP 31 (r) Type of Cooling : Oil Cooled (s) Metering : LCD Display as Optional (s) Metering : LCD Display as Optional
Supply, installation, testing and commissioning of L.T Panel board suitable for 415 Volts, 3 Phase 4 Wire, 50 Hz AC Supply System confirming to IS:8623/93, outdoor type floor mounting along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The panel shall be front openable and having inner & outer shells. The inner shell duly compartmented for each control gear, including Powder coating internally and externally the entire steel surfaces. All the cover shall be provided with suitable locking arrangements. Panel mounted on angle iron stand of minimum 60 cm height from the PCC grouting made out of angle size 50 X 50 X 6 mm grouted in PCC (1:3:6) using 20 mm graded crushed stone aggregates, including accommodating the following componets as given in srl no 28.01 to controls gears and suitable size of Digital volt meter & Digital Amp meter with CTs.installation, testing & commissioning with & including following :- ( Panel Size 1975(H) x 1000 (W) x 1000 (D) (A) IN COMING :- (a) 630 A 4P ACB 50 KA with Microprocessor Based O/C, S/C & E/F Protection -01 No (Make : L&T). (b) Breaker Control Switch ( 2 NO + 2 NC) 25 KA - 01 No.
Supply and Fix ON load change over switch of 400 Amps capacity four pole 415 volts with sheet steel enclosures complete all as specified and as directed.
Supply,Installation, Testing and commissioning of 300 KVA UPS and online 300 KVA UPSsystem with battery backup together with MS Battery stand and connectors complete all as specified and as directed and with the following components :- (a) UPS Model : Falcon Series. (b) 3 Phase Input and 3 Phase Output. (c) IGBT Based system. (d) 32 Bit Microprocessor based UPS to delivery accurate power. (e) Battery Details : Sealed Maintenence Free Batteries ( 96 Nos- 12 Volts - 150 AH). (f) UPS to Battery cable upto 5 mtr distance.
M/s. P S REDDY (BID ID -3070787)
Sri Associates (BID ID -3069822)
Accurate Power Systems (BID ID -3071042)
B D Raizada Projects Pvt Ltd (BID ID -3070162)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .