Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 LAccepted-AOC 01 BALIA BALIA SAGARDIGHI MURSHIDABAD WEST BENGAL 742237 | MURSHIDABAD | WEST BENGAL | 742237 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹1.6 L+₹814.37 (0.52%)Rejected-Finance 17 1 ABHOY HALDER LANE KOLKATA | KOLKATA | L2 | Rejected-Finance Rejected | |
| 3 | L3₹1.6 L+₹1,718.95 (1.10%)Rejected-Finance 138 CANNING STREET GROUND FLOOR KOLKATA | KOLKATA | WEST BENGAL | L3 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹4,000
Closing Date
22 Jul 2024, 6:00 pmClosed
Assistant Engineer
O/O AE, BMSD(W/S), PHE Dte, Ailakundi, Bankura
Repairing work for preventation of oil leaking from Transformer at Intermediate Boosting Station of Uporgora saltora chhatna BRGF water supply scheme under Bankura Mechanical Division,P.H.E Dte.
2024_PHED_709298_7
WBPHED/AE/BMSD/NIeT- 3 OF 2024-2025
Open Tender
MECHANICAL
Item Rate
10 days
Bankura
Please refer Tender documents.
5 documents required · 5 mandatory
₹4,000
Yes
19 Feb 2025
12 Jul 2024
25 Jul 2024
12 Jul 2024
22 Jul 2024
12 Jul 2024
Amount
Repairing of Oil leakage from 11 KV Incoming Bushing & 6.6 KV Outgoing Bushing of 11/6.6 KV 2000 KVA Outdoor Oil Transformer Sl. No. OD 232/01. Jobs as follows :- Decantation of Transformer Oil up to both side Bushing through Oil Filter Machine & storage to vacant Oil Drum. Dismantling & disconnection of 11 KV & 6.6 KV Cable from Bushing. Dismantling of Conservator Tank with Buchholz Relay. Dismantling of top cover with HV & LV side inspection cover. Dismantling & disconnection of HV & LV Bushing with internal terminal connection. Cleaning of HV & LV Bushing. Refitting of HV & LV Bushing with new conical rubber washer including reconnection of inter connection terminal with outside new gasket. Refitting of top of cover of main tank with inspection cover by new gasket. Fitting & fixing of Conservator before cleaning of looking oil glass including of Buchholz Relay. Refilling of Transformer Oil up to the Level through Filter Machine. Reconnection of existing cable at both side HV & LV including proper tapping by HT Tape. Filtration of Transformer Oil including BDV Value testing through Oil Testing Kit. IR Value testing by 2.5 KV Megger. Commissioning of the Transformer
Repairing of Oil leakage from Bushing of 11/0.433 KV 125 KVA Outdoor Oil Transformer Sl. No.CD009/02 . Jobs as follows :- Decantation of Transformer Oil up to both side Bushing through Oil Filter Machine & storage to vacant Oil Drum. Dismantling & disconnection of 11 KV & .433 KV Cable from Bushing. Dismantling of Conservator Tank . Dismantling of top cover. Dismantling & disconnection of HV & LV Bushing with internal terminal connection. Cleaning of HV & LV Bushing. Refitting of HV & LV Bushing with new conical rubber washer including reconnection of inter connection terminal with outside new gasket. Refitting of top of cover of main tank of new gasket. Fitting & fixing of Conservator before cleaning of looking oil glass including of Buchholz Relay. Refilling of Transformer Oil up to the Level through Filter Machine. Reconnection of existing cable at both side HV & LV including proper tapping by HT Tape. Filtration of Transformer Oil including BDV Value testing through Oil Testing Kit. IR Value testing by 2.5 KV Megger. Commissioning of the Transformer.
Supply & delivery of Transformer Oil.
Transportation charges for carrying of Filter Machine with Oil Testing Kit from Kolkata to Saltora IBS, Upargora & back to site.
Add: 18% GST
Add: 1% Cess
ORIENTAL ENGINEERING CO.
WEST BENGAL ENGINEERING CO.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .