Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-AOC 68 BANK COLONY SUNDER NAGAR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹4.6 L | L1 | Accepted-AOC Tender accepted and reasonable quoted rate |
| 2 | L2₹5.1 L+₹52,265.50 (11.4%)Rejected-Finance H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹5.1 L+₹52,265.50 (11.4%) | L2 | Rejected-Finance Higher side quoted rate |
| 3 | L3₹5.3 L+₹68,027.50 (14.9%)Rejected-Finance NEAR CIVIL HOSPITAL WARD NO 07 VPO CHOWARI DISTT CHAMBA HP 176302 | CHOWARI | CHAMBA | HP | 176302 | ₹5.3 L+₹68,027.50 (14.9%) | L3 | Rejected-Finance Higher side quoted rate |
| 4 | L4₹5.9 L+₹1.3 L (29.5%)Rejected-Finance | ₹5.9 L+₹1.3 L (29.5%) | L4 | Rejected-Finance Higher side quoted rate |
| 5 | L5₹6.0 L+₹1.4 L (30.5%)Rejected-Finance | ₹6.0 L+₹1.4 L (30.5%) | L5 | Rejected-Finance Higher side quoted rate |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
24 Aug 2020, 6:00 pmClosed
AGE(I)Dalhousie
AGE(I)Dalhousie
REPAIR/MAINTENANCE OF INTERNAL ELECTRIFICATION, FITTING AND FIXTURES, DISTRIBUTION BOARDS, ELECTRIC METERS AND SUBMAIN, FOR ZONE C AREA AT DALHOUSIE
2020_MES_355926_2
AGE(I)/D-16/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
AGE(I)Dalhousie
As per tender and NIT doc
8 documents required · 8 mandatory
₹500
AGE(I)Dalhousie
₹16,000
6 Oct 2020
11 Aug 2020
26 Aug 2020
11 Aug 2020
24 Aug 2020
11 Aug 2020
Amount
Taking down carefully existing copper/aluminium point wiring of any type (light/fan/socket or power) complete fixture and fittings such as switches ,ceiling rose, regulators,sockets etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per sch of credit) and making good disturbed surfaces of wall, floor, ceiling etc.
M & L for point wiring in replacement with copper conductor cable multistrand, PVC unsheathed 1.5 Sqmm size FRLS for one light point / fan point or bell point controlled by one switch including one run of 1.5 Sqmm multistrand FRLS PVC unsheathed copper conductor cable for earth continuity in and including PVC casing and capping of approved size,make and quality ISI marked, including providing suitable size of copper lugs and all other required accessories as specified in Preamble 1(a) to (q) of section 19 of SSR Part-II under heading 'Point wiring' fixed on walls/ceiling including sunk cast iron boxes concealing on wall for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover all as specified and directed. Make of wire :- Havells / Polycab / finolex / Plaza
All as per Srl item No 2 here in before but for one 5 amps socket out let on same board.
All as per Srl item No 2 here in before but for one 5 amps socket out let on independent board,
All as per item No 2 above but for power point 3 pin switch socket 15 Amp with PVC insulated copper conductor cable multistrand unsheathed 2.5 Sqmm FRLS on independent board including one run of 1.5 Sqmm multistrand FRLS PVC sheathed copper conductor cable for earth continuity in and including PVC casing and capping of appropriate size makes and best quality ISI marked, including CI/Pressed steel sunk box and providing suitable size of copper lugs and all other required accessories as specified in preamble 1(a) to (q) of Section-19 of SSR Part-II under heading "Point wiring" fixed on wall including sunk cast iron boxes concealing on wall for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover all as specified and as directed. Make of wire :- Havells / Polycab / finolex / Plaza
M & L for point wiring in repair with copper conductor cable multistrand, PVC unsheathed 1.5 Sqmm size FRLS for one light point / fan point or bell point controlled by one switch including one run of 1.5 Sqmm multistrand FRLS PVC unsheathed copper conductor cable for earth continuity in and including surface conduit not less than 20 mm PVC conduit non rigid of heavy duty and approved make and quality ISI marked, including providing suitable size of copper lugs and all other required accessories as specified in Preamble 1(a) to (q) of section 19 of SSR Part-II under heading "Point wiring'".fixed on walls/ceiling including sunk cast iron boxes concealing on wall for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover all as specified and directed. Make of wire :- Havells / Polycab / finolex / Plaza
All as per Srl item No 6 here in before but for one 5 amps socket out let on same board.
All as per Srl item No 6 here in before but for one 5 amps socket out let on independent board,
All as per item No 6 above but for power point 3 pin switch socket 15 Amp with PVC insulated copper conductor cable multistrand unsheathed 2.5 Sqmm FRLS on independent board including one run of 1.5 Sqmm multistrand FRLS PVC unsheathed copper conductor cable for earth continuity in and including surface conduit not less than 20 mm PVC conduit non rigid of heavy duty and approved makes,and best quality ISI marked, including CI/Pressed steel sunk box and including providing suitable size of copper lugs and all other required accessories as specified in preamble 1(a) to (q) of Section-19 of SSR Part-II under heading 'Point wiring' fixed on wall including sunk cast iron boxes concealing on wall for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover all as specified and as directed. Make of wire :- Havells / Polycab / finolex / Plaza
Supply & Fixing in replacement Switch piano, flush button, single pole one way 5 amps. Make :-Anchor/Cona/Plaza/SSK
Supply & Fixing in replacement Socket outlet 3 pin, 5 amps flush type. Make :-Anchor/Cona/Plaza/SSK
Supply & Fixing in replacement Switch piano, flush button, 15 amps single pole one way.Make :-Anchor/Cona/Plaza/SSK
Supply & Fixing in replacement Socket outlet 2 in 1,3 pin 5 and 15 amps flush type.Make :-Anchor/Cona/Plaza/SSK
Supply & Fixing in replacement Bell push Switch piano, flush button, single pole one way 5 amps.Make :- Anchor / Cona / Plaza / SSK
Supply & Fix in replacement Electric Bell Ding Dong 230 Volt AC 50 Hz complete all as specified and as directed.Make :- Anchor / Cona / Plaza / SSK
Supply and fix in replacement ceiling rose 65X50 mm three terminals with back plate complete all as specified. Make :- Anchor / Cona / Plaza / SSK
Supply and fixing in replacement lamp holder PVC/Polycarbonate type with back plate for batten/angle fitting. Make :- Anchor / Cona / Plaza / SSK
S & F in replacement of unserviceable tube light fitting with wall mounted LED integrated batten fitting 20 W LED T-5, 4 feet, PVC extruded.Including supply and fixing square Box and all accessories complete all as specified and as directed by Engr-in- charge. Make:- Havells cat part No-LHEXACP7IN1W020 or equivalent in C&S Cat part No LTTB4F20WLEDP/W or Crompton cat part No- CCS-100-20-65-HL2-DP-NWH
Fixing only in replacement of defective flourescent / LED tube light fitting of any make / model into Wall mounted LED integrated batten fitting T5, 20 W LED, 4 feet, PVC extruded. Including supply and fixing square box and all other required accessories complete all as specified and as directed by Engr-in- charge. Note- LED integrated batten fitting T5, 20 W LED, 4 feet of any make / model issued by deparment free for fixing only.
S & F in replacement of unserviceable tube light fitting with wall mounted batten fitting suitable for single T-8 LED tube, 4 feet, PVC extruded.Including supply and fixing square Box and all accessories complete all as specified and as directed by Engr-in- charge. Make:- Havells cat part No- REGALBATTENT 8UPTO1X22WSSBSWH or equivalent in Wipro Cat part No. WIO921208 or Crompton cat part No- DIJB12LT8-20
S & F in replacement of unserviceable tube light with ultra bright glass tubelight T-8 LED, 20W, 6500K, with in built driver with metal heat sink, surge protection ≥ 2.5 kV with 2000 Lumens, 4 feet, double side connection suitable for existing T8 fitting with G13 lamp holder complete all as specified and as directed by Engr-in- charge. Make:- Havells cat part No- CRYSTAL 1213T8DSTL20WLED865SGLASS or equivalent in Wipro Cat part No D612065 or Crompton cat part No- LT8-20-865-(2)
S & F in replacement defective flourescent tube light fitting into Wall mounted LED integrateg batten fitting T5, 10W LED, 2 feet, PVC extruded.Including supply and fixing square box and all other required accessories complete all as specified and as directed by Engr-in- charge. Make :- Havells Cat part No- LHEXBYPNIN1W010 /C&S Cat part No- LTTB2F10WLEDP/W or Crompton cat part No- LCTLN-10-CDL
S&F LED New Adore 3W b-22 CDL candle Lamp(Ball &Candle Lamp) Pin type /Thred Type for wall mounted fancy light fitting complete all as specified and as directed by Engr-in-charge Make:- as makes mentioned in Appendix "C"
S & F in replacement defective LED ultra mordern recess mounting luminaire with high brightness SMD LED as light sources, suitable for Armstrong/Grid ceiling. fixture in mm (LXWXH) 600X600X70 of make:- Crompton Cat part No-LCPL-36-CDL(2x2)/ C&S cat part No- LTCRSLM36WATT2X2 / Bajaj Cat part No-BCTBLR 36W LED FP CW, complete all as specified and as directed by Engr-in- charge.
Supply and fixing in replacement building security light 1x25 watt LED complete with tuff net glass protection IP 66, fixed to wall including with GI bracket made out of light grade 32 mm dia tubing up to 1.2 mtr lenth bend to shape with two sets of MS clamps made out of 25x3 mm flat iron with suitable nuts and bolts and testing complete all as specified and directed. Make:- Havells cat part No.ENDURAPEARLSL25WLED757SASYTOPCMP 9405 / Crompton Cat part No- LSTS-25-CDL or Bajaj Cat part No- BRLEP 25W LED
Supply and fixing in replacement PVC rectangular block (Gang Box) for mounting switches, Sockets,fan regulator etc with 3 mm thick plastic laminated hylum sheet cover of size size 100 mm x 100 mm and 50 mm deep complete all as specified and directed.
Supply and fixing replacement PVC rectangular block (Gang Box) for mounting switches, Sockets,fan regulator etc with 3 mm thick plastic laminated hylum sheet cover of size size 175 x 100 x 50 mm deep complete all as specified and directed.
Supply and fixing replacement PVC rectangular block (Gang Box) for mounting switches, Sockets,fan regulator etc with 3 mm thick plastic laminated hylum sheet cover of size size 200 x 150 x 50 mm deep complete all as specified and directed.
Supply and fixing in replacement PVC rectangular block (Gang Box) for mounting switches, Sockets,fan regulator etc with 3 mm thick plastic laminated hylum sheet cover of size size 250 x 150 x 50 mm deep complete all as specified and directed.
Supply and fixing in replacement of unserviceable/ brocken backlite hylum sheet of size (4''x4'') with suitable screw etc complete.
Supply and fixing in replacement of unserviceable/ brocken backlite hylum sheet of size (7''x4'') with suitable screw etc complete.
Supply and fixing in replacement of unserviceable/ brocken backlite hylum sheet of size (8''x10'') with suitable screw etc complete.
Supply and fixing in replacement of unserviceable/ brocken backlite hylum sheet of size (10''x12'') with suitable screw etc complete.
Supply and fixing in replacement of unserviceable/ brocken 25 mm width heavey duty double lock pess type casing & caping ISI marked fixing to wall/ceiling using screws of suitable size including removing the existing for replacement complete all as specified and directed.
Supply and fixing in replacement of unserviceable/ brocken Rigid non-metallic PVC conduit 20mm dia heavey duty exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. ISI marked fixing to wall/ceiling using screws of suitable size including removing the existing for replacement complete all as specified and directed.
Material and labour factory made sheet metal enclosure dust and vermin proof made out of 2.00mm thick Ms sheet of size 90x60x25 cm depth with double door hinged shutter and locking arrangement for fixing DBs, KWH meter etc flushed/semi flushed /grouting on wall as per site requirement including DIN rail channel for mounting of MCB,s SP/SPN. And provide in 4 rows TPN aluminium bus bar channel of rating 200 Amps duly mounted on 'F' class insulator with colour coded heat shrinkable sleeves and powder coated paint with suitable for one no for incoming of FP MCCB with internal connection of 16 sq mm multistrand copper wire with copper lugs from MCCB to Busbar etc. after prepration of surfaces with suitable glass vision panel complete all as directed (Note: Unit rate shall be inclusive of making good the area not exceeding 0.6 sqm and not exceeding 0.125m depth for filling the hollow existing surface with half bricks in CM (1:4) including taking down old unsv any type of sheet metal enclosure or main switch complete all as specified and as directed by Engr-in- charge.
Supply & Fixing in in replacement sheet metal enclosure for DBs double door(When MCB,s to be used ) Tripple pole & neutral 4 way with 200 Amps rated Bus-Bar 415 volts with fixing arrangement complete,including taking down ICDP/Dbs any type including taking down of Kit kat fuse /MCB SPN/SP as directed by Engr-in-charge, Make:-C&S Cat part No-CSDBTPNHPDD04/ Havells Cat part No-DHDNTHNCDRW04/Legrand Cat part No-6077 15
Supply & Fixing in replacement Sheet metal enclosure for DB,s, double door (when MCB,s to be used) single pole & neutral 8 way with 200 amps rated bus bar 240 volts with fixing arrangements including taking down ICDP/DB's kitkat fuse/MCB SPN/SP as directed by Engineer-in-charge. Cat Part No CSDBSPNPDD08 of C&S/ Cat part No-DHDPSHODRW08 of Havells/ Cat Part No-6077 11 of Legrand,
S&F inrepair Moulded case circuit Breaker (MCCB) FP with fix thermal magnetic release capacity 125 Amps ,415 Volts 50 HZ 10 KA including making necessary connection with spreader, link and copper lugs including taking down old unserviceable MCCB/ main switch of any capacity and make complete all as specified and as directed. Make:- C&S Cat part No-CS2S4/ Indoasian Cat part No-830718/ Havells Cat part No-IHLGSF0125 #
Supply & Fixing in replacement MCB TPN 63 Amps 415 volts 10 KA complete with Fixing arrangement all as specified and as directed by Engr-in-charge, Make:- C&S Cat part No-CSMBS3C63N/ Indoasian Cat part No-811220/ Legrand Cat part No-4065 20
Supply & Fixing in replacement MCB TPN 40 Amps 415 volts 10 KA complete with Fixing arrangement all as specified and as directed by Engr-in-charge, Make:- C&S Cat part No-CSMBS3C63N/ Indoasian Cat part No-811218/ Legrand Cat part No-4065 29
Supply and fixing inreplacement MCB single pole and neutral 63 Amps, 240 volts complete all as specified and directed. Make:- C&S Cat Part No-CSMBS1C63N / Indoasian Cat part No-811154/ Legrand Cat Part No-4086 20
Supply and fixing inreplacement MCB single pole and neutral 40 Amps, 240 volts complete all as specified and directed. Make:- C&S Cat Part No-CSMBS1C43N / Indoasian Cat part No-811152/ Legrand Cat Part No-4086 18
Supply and fixing inreplacement MCB single pole and neutral 32 Amps, 240 volts complete all as specified and directed. Make :- C&S Cat Part No-CSMBS1C6N to CSMBS1C32N / Indoasian Cat part No-811144 to 811151/ Legrand Cat Part No-4086 09 06 to 4086 17 032
Supply and fixing inreplacement MCB single pole 6 to 32 Amps, 240 volts all as specified and directed. Make:- C&S Cat Part No-CSMBS1C6 to CSMBS1C32/ Indoasian Cat part No-811122 to 811129/ Legrand Cat Part No- 4085 87 06 to 4085 95 032
Supply and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor of size 16 sq mm served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular.
M & L for Sub main wiring in replacement with two single core FRLS, PVC insulated and unshseathed copper wire FRLS multistrand of size 4 sqmm along with 2.5 sqmm single core FRLS, PVC insulated and unseathed copper wire as earth wire connecting to common earth including providing suitable size of copper lugs for connections of cable with MCBs or bus bars and including PVC casing and caping of appropriate size and best quality ISI marked complete all as specified and directed.
M & L for Sub main wiring in replacement with two single core FRLS, PVC insulated and unshseathed copper wire multistrand of size 4 sqmm along with 2.5 sqmm single core FRLS, PVC insulated and unseathed copper wire as earth wire connecting to common earth including providing suitable size of Copper lugs for connections of cable with MCBs or bus bars and including PVC surface conduit of appropriate size and best quality ISI marked complete all as specified and directed.
M & L for Sub main wiring in replacement with two single core FRLS, PVC insulated and unshseathed copper wire multistrand of size 6 sqmm along with 4 sqmm single core FRLS, PVC insulated and unseathed copper wire as earth wire connecting to common earth including providing suitable size of copper lugs for connections of cable with MCBs or bus bars including PVC casing and capping of appropriate size and best quality ISI marked complete all as specified and directed.
M & L for Sub main wiring in replacement with two single core FRLS, PVC insulated and unshseathed copper wire multistrand of size 6 sqmm along with 4 sqmm single core FRLS, PVC insulated and unseathed copper wire as earth wire connecting to common earth including providing syitable size of copper lugs for connections of cable with MCBs or bus bars including PVC surface conduit of appropriate size and best quality ISI marked complete all as specified and directed.
Material and labour in replacement for Earthing complete with galvanised steel earth plate electrode 600x600x6.00mm thick burried directly in ground (earth pit not less than 2.25 Mtrs below ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to GI earth lead wire of 4.0 mm dia by means of bolts, nuts, check nuts, as earth lead complete including 40 mm bore dia protection pipe GI medium grade upto 7.5m length, watering pipe 15mm bore dia GI medium grade 1.70m length, charcoal & salt filling, necessary earth work in any type of soil including Rocky soil also, concrete pit, funnel removal of surplus soil upto 50m distance all as per electrical plate No.3 of SSR Part I and connected to earthing test point, main board/upto main DB including testing on completion all as specified and directed.
Note for Srl No.1 to 50 :- (i) Contractor will detail electrician and helper for daily to attend the regular complains for above mentioned repair / replacement of unserviceable items in BOQ and No extra payment shall be made out on this account as directed by Engineer-in-charge. (ii) Cotractor/superviser will collect electrical complaints from concern JE / MES rep and complete on same day. (iii) Contractor will provide suitable transportation for attending complaints on site like motorcycle etc to each electrician / helper with proper documents, driving licence / helmet etc and keep permission of vehicle for inside permises by compitent authority.(iv) Contractor will provide electrical tools like electric tester, test lamp, multi meter, cutting plier, screw driver, electric hammer, drill machine, wiring steel wire etc on his own arrangement for rectifiying the complaint and also screws,nut bolts insulation tape as per site requirment and no extra payment will be made for the same.
M/S SHAKTI ELECTRIC WORKS
m/S Varun Gupta
M/s. Rishav Sood
KISHAN CONTRACTOR
Vishav Karma Refrigeration and Electric Work
Pathania Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .