Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L1 | Accepted-Finance Being lowest | |
| 2 | L2₹23.5 L+₹52,121 (2.27%)Rejected-Finance | L2 | Rejected-Finance not being lowest | |
| 3 | L3₹27.4 L+₹4.4 L (19.3%)Rejected-Finance | L3 | Rejected-Finance not being lowest | |
| 4 | L4₹27.9 L+₹4.9 L (21.2%)Rejected-Finance SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L4 | Rejected-Finance not being lowest | |
| 5 | L5₹28.3 L+₹5.3 L (23.2%)Rejected-Finance | L5 | Rejected-Finance not being lowest |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
8 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (CME) Khadki
Garrison Engineer (CME) Khadki, Phugewadi, Dapodi, Kendriya vidyalay Gate , beside Unlimited (Mega Mart) Mall, Pune - 411 012
Repair/maintenance of steam bath, sauna bath, geyser, solar water heater and allied works with maint and descaling of hot water lines and repair/ maintenance of low tension electric system and allied work at MD accn, CTW, 262 CEDU, FCBRNP at CME
2023_MES_594580_1
8416/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer (CME) Khadki
Class D, category b(i)
9 documents required · 9 mandatory
₹500
Yes
Garrison Engineer (CME) Khadki
₹94,000
Yes
15 Jun 2023
11 May 2023
14 Jun 2023
11 May 2023
8 Jun 2023
26 May 2023
12 May 2023 - 25 May 2023
Amount
M & L for servicing solar Flat Plate collector by removing the flange plates, cleaning the collectors internally by using descaling solution, removing the blockages in the collectors complete and refixing the flange plates, testing for satisfactory function all as specified and directed.
S & F heating element 25mm to 32mm dia, ISI marked for solar water heating plant of capacity 3 KW all as specified and directed.
S & F flange plates of size 25 mm dia suitable for flat plate collectors including taking down old unseviceable flange plate all specified and directed.
S & F thermostat for solar water heating plant of 100 & 200 LPD of suitable size and ratings etc complete all as specified and directed.
S & F flexible heat resistance rubber pipe (from inter connect plate collector to hot water tank) of size 25 mm to 32 mm dia etc with fixing clamp etc complete all as specified and directed.
Taking down the collector from its position, removing the top glass of collector and carry out welding/brazing work to the collector and arresting the leakages in the collector, refixing top glass back with all sealing agent, testing for satisfactory function all as specified and directed.
Taking down the old unserviceable solar flat plate collector by disconecting flange plates and rubber hose pipes and replacing with new flat plate collector of same size and model, connecting flange plates and rubber hose complete, testing for proper functioning all as specified and directed.
M & L for submain wiring with two runs of 4 sq mm single core multi stranded FRLSH PVC insulated and unsheathed copper conductor (red for phase and black for neutral) of grade 1100 volts and including electrical grade PVC casing caping of desired colour not less than 1.2 mm and 25 mm wide & 4 sq mm copper conductor cable FRLSH PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and as directed including taking down old wiring. Note :- Two run of 4 Sqmm, and one run of 4 Sqmm earthing wire and one run of casing caping shall be measured as one length
Steam Bath : Checking of electrical wire connection , level sensors, Heaters coil, earthing leakage, electronic circuits & control panel & safety arrangements of the water level & units. Cleaning the sensors, descaling of hard water tank & servicing of electrical, pneumatic valve. Proper insulation for the boilers including replacement of defective spares and fixing the same with new including testing etc complete. Note: - (a) Contractor has to visit the plant once in a month and carry out comprehensive maintenance as directed by Engr-in-Charge. (b) During emergency contractor has to visit the plant to rectify the fault without any extra cost to the Govt. (c) Any spares required during comprehensive maintenance and during emergency repairs shall be measured under respective item as " Supply only)
Sauna Bath :- Checking of the heater coil, electronic temp control, calibrating temp device, Accuracy, safety cut off the heater & cleaning the sensors of the electronic devices / equipments etc including replacement of defective spares and fixing the same with new including testing etc complete. Note: - (a) Contractor has to visit the plant once in a month and carry out comprehensive maintenance as directed by Engr-in-Charge. (b) During emergency contractor has to visit the plant to rectify the fault without any extra cost to the Govt. (c) Any spares required during comprehensive maintenance and during emergency repairs shall be measured under respective item as " Supply only)
Supply only 15 psi safety valve (Pressure relief valve)
Supply only 240 V 5 amps glass fuse
Supply only auto drain solenoid valve 12 volts 6 watts for steam bath.
Supply only water inlet solenoid valve 12 volt 6 watts for steam bath
Supply only Boiler insulation glass wool 25mm thick 40 Kg density with aluminium foil for steam bath.
Supply only steam water level circuit board & main relay board for steam bath.
Supply only steam generator power heating element 3000 watts for steam bath
Supply only sauna bath heating element 3 KW for sauna bath
Supply only high limit temperature (i.e 105 degree) switch thermostat for steam bath/sauna bath
Supply only stainless steel boiler for steam bath tank as per existing make and size.
Supply only water level sensor with Teflon collar & S/S No. Electrodes.
Supply only Temperature sensor including extension wire of length 6 metre for steam bath
Supply only Digital Control steam processor circuit board for steam/Sauna bath.
Supply only Digital Control panel ABS plastic cover for steam bath/sauna bath.
Supply only Digital Control Key pad overlay cover for steam bath.
Supply only step down Transformer with dual output primary 230 V and secondary 35 Volt 5 Amps for steam bath.
Supply only Mains power Terminal 4 way connector 63 amps
Supply only steam contactor 230 V coil 63 amps 3 phase 440 volt for steam plant.
Supply only silicon heater washer
Supply only power contactor 40 Amps 440 volts, 50 Hz
Supply only temperature thermostat range 30 to 110 degrees.
Supply only 4 way channel terminal strip connector 32 Amps.
Supply only high limit upto 95o C temprature switch 40 Amps rating for steam bath.
Supply only Sauna wooden insulation 40 Kg density complete
Supply only electronic sauna room temperature controller.
Supply only low density industrial Sauna heating element 2000 watt.
Supply only flame proof wires 6 Sqmm for Sauna heater/steam bath.
Repair/checking to storage type water heater (geyser) of any capacity including replacement of required spares such as heating element, thermostat, indicator, fusible plug dead weight,hot/cold water hose pipes incl any other repairs work at different locations at CME all as specified and directed by Engr in charge for the Make: Bajaj, Ditz, Primer, Galco, Racold or any other make). Note : (1) Spare components will be mesaured and paid seperately. (2) Contractor will detail mechanic to AGE E/M complaint cell at 0900 daily to collect docket.
Supply only thermostat complete with temperature setting manually extra long (11 inches) ISI marked suitable for geysers 25 litres to 50 litres capacity
Supply only thermostat cut-out with knob complete at tripping 90 degree (+5%) Temperature of length (7 inches) ISI marked suitable for geysers 25 litres to 50 litres capacity.
Supply only fusible plug ISI marked suitable for 25 to 50 litres capacity Geysers.
Supply only safety valve (tobe fixed on outlet connection) ISI marked suitable for 25, and 50 litres capacity geysers.
Supply only apparatus plate for geyser 25 Ltrs capacity
Supply only apparatus plate for geyser 50 Ltrs capacity
Supply only heating element upto 2 KW as required at site including rubber washers (ISI Marked) complete
Supply only non return valve (NRV) brass of 15mm bore, after dismantling old unserviceable NRV of any size all as specified and directed.
S & F in repairs Hot/Cold water flexible hose pipe (ALLOY FLEXIBLE HOSE PIPE 1/2") 12/16mm and 450 to 900mm long heavy duty covered with metal wires heat resistence with both ends PVC hexagonal check nut with washer to fixed on 15mm dia GI pipe all as specified and directed.
Supply only insulation material ( Glass Wool ) for geysers
M & L for preparation of steel surface of geysers, apply putty to make the surface smooth/ even and applying one coat of synthetic enamel paint white including writing of MES Nos with black paint complete all as directed & for any size or capacity of geysers .
Taking down loose geysers of any capacity from store/site and installing the same at new location within the CME complete with grouting of bolts & all necessary pipe connections and making good the disturbed wall surfaces all as directed. Note :- Spares if required shall be measured and paid separately.
M & L to repair the leakge of copper inner tank of geysers of any capacity by gas welding/brazing for water tightness complete and test under pressure.
S & F single pole and neutral encloser with two pin and earth plug and socket complete with one single pole MCB 20 Amps 240 volts including taking down.
S & F GI tubing (Medium grade) with all fitting and fixed to complete on wall and ceiling or laid in trenches of size 15mm bore incl taking down old unserviceable one all as specified and directed.
M & L for stop valve, cast copper alloy, screw down high pressure, crutch handle screwed both end for iron pipe, fancy type, chromium plated for 15mm bore pipe incl taking down old unserviceable one .
M & L for Bib tap, fancy type, chromium plated for 15mm bore pipe including taking down
S & F gasket rubber ring for heater plate of any size geyser.
S & F indicator lamp of geyser 25-50 litres capacity of RED/GREEN colour including taking down
S & L PVC copper conductor cable 3 core 2.5 sq mm flexible multistranded 1100 V grade unsheathed cable including taking down
M & L for switch socket combination 2 in one 3 pin 16 Amps 240 volts flush type complete including taking down all as speciied and directed.
M & L for socket outlet 3 pin incl PVC enclosure 240 volts controlled by one MCB SP 25 Amps, complete including taking down all as specified and directed.
M & L for Metal clad industrial pug top of cap 16 Amps including taking down
M & L for plug top porcelein 3 pin 15/16A 230 V AC supply including taking down
Excavation in trenches n exc 1.5m wide and n exc 1.5m deep and making good surface for laying /removing of cable all as specified and directed by Engr in charge as in
Soft/loose soil
Hard/dense soil
Soft/disintegrated rock.
Returning filling in excavated soil in trenches, watering and well ramming in layers n exc 25 cm complete all as specified.
Removal of surplus excavated spoil to distance not exc 50 metre and depositing where directed at a level not exc. 1.5 m above, the starting point all as specified and directed
M&L for clean dry river sand cushioning to undeground cables in trenches including spreading, leaveling hand punning and onsolidating complete all as specified. Note- thickness after punning down shall be measured and paid.
Supply & Laying in replacement of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 90 mm and inner dia 76 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable incl couplers & bends complete all as specified and directed.
Supply & Laying in replacement of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable incl couplers & bends complete all as specified and directed.
Supply and lay factory made, ISI marked, un-reinforced precast concrete cable cover class LV type-1, flat of size 250mmx150mmx40mm complete all as specified.
M & L for bituminous road cutting to a width of 45 cm and depth 50 cm for laying of pipe for laying of UG cables and making good with PCC (1:3:6) type C1 (using 20mm grade stone aggregate) all as specified and directed.
Dismantling and removing and setting aside with CME areas PCC poles any type/size by breaking PCC foundation after disconnecting electrical connection incl site clearance complete all as specified and directed by Engr-in- Charge.
Dismantling and removing and setting aside for credit old unsv steel tubular pole any type/size by breaking PCC foundation after disconnecting electrical connection incl site clearance complete all as specified and directed by Engr-in- Charge.
M & L in replacement erection in true vertical position (or to be fixed in an inclined position as strut pole) steel tubular swaged poles complete with MS base plate of 6 mm thick of size 300 mm x 300 mm, finial taper plug, pole cap, bolts, nuts and washers and screwed pole made out of FRW MS tubing conforming to IS-2713 (Part-II) 1980 type 410-SP-31 ( 9 metres long ) pole including drilling of holes of required size and Nos for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embeded in concrete, etc complete all as specified and directed.
M & L for PCC 1:3:6 type C2 using 20 mm graded stone aggregate for coping of poles/plinth blocks of HT poles etc incl fair finishing the exposed surfaces even and smooth without using extra cement including necessary form work complete all as specified & directed.
M & L for PCC 1:4:8 type D2 using 40mm graded stone aggregate for foundation of poles complete all as specified and as directed.
Supply , laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminium conductor 1100 volts grade in trenches/ passing through pipe/fixing on walls, floors etc incl using suitable clamp of cross sectional area 4 core 16 Sqmm in and including taking out old one all as specified and directed.
All as per item No.77 above, but of the size 4 core 25 Sqmm
All as per item No.77 above, but of the size 3.5 core 35 Sqmm
All as per item No.77 above, but of the size 3.5 core 50 Sqmm
All as per item No.77 above, but of the size 3.5 core 70 Sqmm
All as per item No.77 above, but of the size 3.5 core 95 Sqmm
All as per item No.77 above, but of the size 3.5 core 120 Sqmm
All as per item No.77 above, but of the size 3.5 core 150 Sqmm
All as per item No.77 above, but of the size 3.5 core 185 Sqmm
All as per item No.77 above, but of the size 3.5 core 240 Sqmm
All as per item No.77 above, but of the size 3.5 core 300 Sqmm
M&L for fault detection in damaged UG cables using cable fault detector/locator, vehicle mounted to accuracy of 2m for various locations inside CME for UG cables of any size & any type upto 22kv grade including excavation & earthwork in any type of strata of size 4x2x0.6m to visually inspect/repair the damaged cable when and where directed by Engr-in-charge.
Supply and fix straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5/4.0 x 25-50 Sqmm complete all as directed by Engr-in charge.
Supply and fix straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 70-120 Sqmm complete all as directed by Engr-in charge.
Supply and fix straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 150-185 Sqmm complete all as directed by Engr-in charge.
Supply and fix straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 240-300 Sqmm complete all as directed by Engr-in charge.
Material and labour in replacement of old broken ACSR with aluminium conductor steel reinforced streching without kinks / bends and binding with insulators on street poles complete all as specified and directed by Engineer-in-Charge.
Material & labour in replacement of old cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed inclusive of one primer coat, one under and one finishing coat of aluminium paint all as specified.
Material and labour in replacement of pin type, porcelain, vitreous, white brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 Volts grade.
Material and labour in replacement shackle type porcelain vitreous white, brown or green insulator incl GI mild steel strip, washer, insulator bolts, washers and nut for working pressure 1100 volts section of strips 31 x 3 mm,max dia 90mm, height 75 mm,dia of bolt 12mm upto 9 metre long
S & F in replacement of stay assembly complete with accessories as shown in electrical plate No 1 incl GI Adjustable Stay Rod of 20 mm Dia, GI Stay wire of size 7/4 mm incl stay clamps, loop type insulator, excavation in any strata and PCC 1:3:6 type C2 all as specified and directed.
M&L in replacement of cradles, hexagonal/rectangular fabricated with GI steel wire 4 mm dia complete all as specified and directed.
M & L for loose filling with aggegregates of gauge 40mm in switch yard and surrounding to LT panels complete all as specified and directed.
Re-stringing of over head line ACSR conductor on existing lines by unbinding at each pin/shackle/Disc type insulator and re-fixing the same after stretching conductor, removing excess sag, maintaining proper distance between conductors as specified, tightening of stay wire, binding of PVC line seperators two per span, all as specified and as directed for the following types of configurations:-
Set of four
Set of two
Guard wire
M&L for cutting of tree branches n.exc 10 cm in girth along LT OH lines at distance not less than 3 m distance from both sides of conductors complete incl clearing of bushes any type not less than dia 10 cms and all other growings around respective poles of area not less than 4 sqm all when and where as specified and as directed. Note.
M&L for clearing of grass shrubs and other growing by uprooting in switchyards and electric installations upto 10 cms in girth at various locations as directed.
Supplying and laying GI tubing light grade 80 mm dia incl all accessories for encasing cables for mechanical protection , laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/floor or along poles with complete accessories such as bends/sockets/reducers/saddles incl necessary threading/drilling works including taking down old tubing . all as specified and directed.
All as per item No.103 above, but size 50 mm bore
All as per item No.103 above, but size 40 mm bore
M&L in replacement of earthing with 600x600x60mm GI earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including GI earth lead of 4 mm by means of bolts, nuts and check nuts and washers to the extent of 7.5 metres as earthing lead and connecting to the eqpt/machinery etc. incl charcoal dust and common salt packed all around the earth plate in alternate layer in the earth pit all as per electrical plate No. 3 of SSR Part I-2009 including chamber made up of PCC 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover, 20mm dia light grade G.I pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement incl excavation and earth work in any type of soil and testing complete all as specified and directed. Note :- GI lead more than 7.5 mtr will be measured and paid separately.
M&L in replacement of earthing with 600x600x60mm GI earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including GI strip 32 x 6mm by means of bolts, nuts and check nuts and washers to the extent of 7.5 metres as earthing lead and connecting to the eqpt/machinery etc. incl charcoal dust and common salt packed all around the earth plate in alternate layer in the earth pit all as per electrical plate No. 3 of SSR Part I-2009 including chamber made up of PCC 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover, 20mm dia light grade G.I pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement incl excavation and earth work in any type of soil and testing complete all as specified and directed. Note :- GI strip more than 7.5 mtr will be measured and paid separately.
M&L for MCCB 4 pole, 400 Amps, 415 V, 50 kA thermal magnetic release adjustable type complete all as specified and directed. Make : Indoasian/L&T/Legrand/Havells
M&L for MCCB 4 pole, 315 Amps, 415 V, 50 kA thermal magnetic release adjustable type complete all as specified and directed.
M&L for MCCB 4 pole, 250 Amps, 415 V, 36 kA thermal magnetic release adjustable type complete all as specified and directed.
M&L for MCCB 4 pole, 160 Amps, 415 V, 25 kA thermal magnetic release adjustable type complete all as specified and directed.
M&L for MCCB 4 pole, 125 Amps, 415 V, 25 kA thermal magnetic release adjustable type complete all as specified and directed.
M&L for MCCB 4 pole, 100 Amps, 415 V, 25 kA thermal magnetic release adjustable type complete all as specified and directed.
M&L for MCCB 4 pole, 63 Amps, 415 V, 25 kA thermal magnetic release adjustable type complete all as specified and directed.
Material and labour for fixing aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 50 sqmm incl dismantling old thimbles of any type.
Material and labour for fixing aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 70-185 sqmm incl dismantling old thimbles of any type.
Material and labour for fixing aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 240-400 sqmm incl dismantling old thimbles of any type.
Material and labour for shifting heavy items / earth work / cleaning areas / clearing site by providing crane/ hydra/ excavators/ tractors/ trolley etc as required at site complete all as specified and directed.
M&L for Chemical spray (DC> 2-26 having container 415ml/300g for precision blended multipurpose product for prevents corrosion penetrates, lubricates, displaces and seals out moisture release rusted mechanism cleanse etc.
M & L for spraying chemical glyphosate concentrate on area to remove unwanted vegitation/grass at various locations as directed. Note : (i) Labour and equipments to spray chemical on required area are incl in quoted rates. (ii) Spray will be repeated quarterly or as per direction of Engr in Charge.
M & L for Preparation of old painted surfaces of electric pole covered by dust and other deposited materials by cleaning from steel tubular pole of length upto 11 metres including cross arms, bracing, clamps etc and painting with one coat of aluminium paint complete all as specified. Note: (i) The quoted rate shall includes marking of numbers on each LT pole as per direction of Engr-in-Charge. (ii) The quoted rates shall including the repairing of coping with cement mortar / PCC.
M & L for Preparation of old cement based painted surfaces of RCC pole 9 mtr by cleaning of deposited materials, and painting with one coat of exterior emulsion weather coat paint of approved make and colour complete all as specified. Note: (i) The quoted rate shall includes marking of numbers on each LT pole as per direction of Engr-in-Charge. (ii) The quoted rates shall including the repairing of coping with cement mortar / PCC.
Taking out old unserviceable LT panel and supply, installation, testing & commissioning, dust, weather & vermin proof LT feeder pillar box (approx size 1.0m x 0.5m x 1.0m) factory fabricated (panel shall be got manufactured from any manufacturer duly approved by CPRI) outdoor cubicle/KIOSK type totally enclosed outer cage fabricated with 3.15mm thick MS sheet with frame made of MS angle iron 50x50x5 mm suitable for operation on 3 phase 4 wire, 440V 50 Hz system, with hinged panel doors on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/ rubber/ wooden bushes to prevent ingress of water/ vermin etc, inside the enclosure. All the holes shall be fixed with chromium plated brass cable glands for cable entry/exit with & including necessary internal wiring with stranded PVC insulated FRLS copper conductor cables of adequate size. The kiosk/ box shall be powder coated internally /externally of approved colour. Quoted unit rate shall be deemed inclusive of PCC foundation, angle iron legs of 50cm above ground level made of angle iron 50x50x5mm & the following accessories:-
Aluminum bus bar rectangular 400 Amps full for phase and half for neutral and interconnection of MCCBs to Bus bar mounted on epoxy insulators with colour coding PVC sleeves.-01Job
MCCB 125 Amps, 4 pole 415 Volts, 50 Hz, 25 KA, thermal magnetic release adjustable type- 01 No ( Incoming)
MCB TPN 63 Amps, 415 Volts, 50 Hz 'C' type - 01 No ( Outgoing)
MCB TPN 40 Amps, 415 Volts, 50 Hz 'C' type - 01 No ( Outgoing)
MCB SPN 40 Amps, 230 Volts, 50 Hz 'C' type - 04 No ( Outgoing)
RYB LED phase Indicator Lamp set - 01 No
Provision of cubicle as per above description to accommodate the above mentioned accessories.
Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable.
Taking out old unserviceable LT panel and supply, installation, testing & commissioning, dust, weather & vermin proof LT feeder pillar box (approx size 1.2m x 0.5m x 1.0m) factory fabricated (penal shall be got manufactured from any manufacturer duly approved by CPRI) outdoor cubicle/KIOSK type totally enclosed outer cage fabricated with 3.15mm thick MS sheet with frame made of MS angle iron 50x50x5 mm suitable for operation on 3 phase 4 wire, 440V 50 Hz system, with hinged panel doors on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/ rubber/ wooden bushes to prevent ingress of water/ vermin etc, inside the enclosure. All the holes shall be fixed with chromium plated brass cable glands for cable entry/exit with & including necessary internal wiring with stranded PVC insulated FRLS copper conductor cables of adequate size. The kiosk/ box shall be powder coated internally /externally of approved colour. Quoted unit rate shall be deemed inclusive of PCC foundation, angle iron legs of 50cm above ground level made of angle iron 50x50x5mm & the following accessories:-
Copper bus bar rectangular 400 Amps full for phase and half for neutral and interconnection of MCCBs to Bus bar mounted on epoxy insulators with colour coding PVC sleeves.-01Job
MCCB 160 Amps, 4 pole 415 Volts, 50 Hz ,36 KA, thermal magnetic release adjustable type- 01 No ( Incoming)
MCCB 100 Amps, 4 pole, 415 Volts, 50 Hz ,25 KA, thermal magnetic release adjustable type - 03 No ( Outgoing)
RYB LED phase Indicator Lamp set - 01 No
Provision of cubicle as per above description to accommodate the above mentioned accessories.
M & L for preparation of old painted surfaces of LT Panel covered by removing dust and other deposited materials from panel of any size and type including repair of panel door by welding work, hinges, nut, bolts, clamp etc and painting with one coat of synthetic enamel paint of existing colour complete all as specified and directed.
M & L for removing of old rusted LT panel stand and supply & fix new LT panel stand made out of MS angle 50 x 50 x 6mm grouted in cement mortar 45 cm below ground level and 60 cm above ground level incl taking out electric connection from panel, lifting of panel from existing position and refixing and reconnecting after welding new stand for panel size not less than 1.2 mtr long, 0.5 mtr wide including painting to new surface of stand with one coat of red oxide and two coat of synthetic enamel paint black colur complete all as specified and directed. Note:- Rate of lifting of panel, earthwork for cable loop opening, returning filling shall deemed to be inclusive in quoted rate.
Taking out of Old ACB and Supply and fixing LT Air Circuit Breaker, 4 pole, manual fixed type, 415 volt with thermal magnetic release of 630 Amp Ics=100% Icu, 50 kA neutral overload protection , inbuilt temp protection upto 90 degree Celcius, rotatable terminals for horizontal/vertical orientation, fast operation and fixing the same in existing panel including necessary modification with angle iron and plain sheet all as directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium multistranded conductor of size 10 sqmm , served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or circular.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium multistranded conductor of size 6 sqmm , served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or circular.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium multistranded conductor of size 4 sqmm , served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or circular.
Techmat trading solution
Pritam Electro Mechanical Services
M/S kirpan Enterprises
Sachin Electricals
Aziz Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .