Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
8 Jul 2020, 6:00 pmClosed
GE UTILITIES
GE UTILITIES UDHAMPUR PO GARHI PIN 182121 UDHAMPUR
Repair /Maintenance of ducting heating blower hot water generator and allied works of Ops Room and CHNC under GE Utilities Udhampur
2020_MES_316688_6
GE/U-58/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹40,000
Yes
2 Sept 2020
17 Jun 2020
10 Jul 2020
17 Jun 2020
8 Jul 2020
24 Jun 2020
Amount
M&L for dismantling of old, rusted and unservieable ducting from existing position complete all as specified and directed by Engr-in-charge.
Supply, assembly and erection of GI Sheet of C&SS rectangular / square duct made out of L shaped hollow profile, duly factory boxed , including all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealant on longitudinal joints etc complete of size 26 Gauge of sheet complete all as specified and directed by Engr-in-charge.
M&L for duct insulation with resin bonded fibre glass wool roll of density 24 kg / cum with factory made laminated aluminium vapour barrier the thickness of insulation is 40mm. Including the cleaning of ducting suface area, applying ruber based adhesive CPRX compound, sealing of all the overlaps, securig insulation with nylon/steel strips of 12 mm in a interval of 1.2 mtrs complete all as specified and directed by Engr-in-charge.
M&L for duct insulation with Cement mixer outside area to protect the ducting complete all as specified and directed by Engr-in-charge.
S&F micro mastic fine filters 5 micro synthetic non woven (washable) polyester media in aluminium housing 18 SWG, efficiency 99.9% of existing size complete all as specified and directed by Engr-in-charge.
S&F of strip heater of 1.5 KW capacity 440 Volt complete all as specified and directed by Engr-in-charge.
S&F of front air grill of the ducting for supply air complete all as specified and directed by Engr-in-charge.
Dismantling the fire damper to the AHU and S&F of new fire damper at the existing position complete all as specified and directed by Engr-in-charge.
S&F of tarpoline cloth to AHU at the suply air area with proper jip and chain system complete all as specified and directed by Engr-in-charge.
Repair to Air handling Unit including greasing to all moving parts, bearings, fans, shaft, motor etc and servicing to air handling unit complete all as specified and directed by Engr-in-charge.
Repair/Rewinding of motor of capacity 5 HP, 3 phase 415 volts by disconnecting the electric supply removing of pully and fan and opening of both end covers taking out Bearings and rotor checking of air gap, checking of rotor field winding, replacement of bearing, greasing of bearings, reassembling ,replacing rusted nut, bolts, washers, checking and adjusting the alignment, connecting electric connection complete all as specified and directed by Engr-in-charge.
Repair/Rewinding of motor of capacity 10 HP, 3 phase 415 volts by disconnecting the electric supply removing of pully and fan and opening of both end covers taking out Bearings and rotor checking of air gap, checking of rotor field winding, replacement of bearing, greasing of bearings, reassembling ,replacing rusted nut, bolts, washers, checking and adjusting the alignment, connecting electric connection complete all as specified and directed by Engr-in-charge.
Taking down and re-fixing existing false of size 70sqm ceiling from site to repair the AC ducting without any damage to existing false ceiling, channels and all connecting items with false ceiling complete all as specified and directed by Engr-in-charge.
M&L for repair to existing unserviceable/defective PC board from panel carefully with out disturbing the cooling coil and fan motors of AC Plant and taking to workshop for checking/ rectifying fault including replacement of unserviceable IC/ relay/transformers replacement of wiring etc and bring back to to the same location and refixing/ connectioning same including testing & commissioning complete all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable AC power contactor upto 16 Amps capacity 440 volts, 50 Hz, 3 phase from the control panel in AC plants including reconnectiong/testing complete all as specified and directed by Engr-in-charge. Make: L&T/BCH/Siemens
Description all as per serial Item No 15 here-in-before but above 16 Amps and up to 32 Amps capacity 440 volts, 50 Hz, 3 phase complete all as specified and directed by Engr-in-charge. Make: L&T/BCH/Siemens
Description all as per serial Item No 15 here-in-before but above 32 Amps up to 63 Amps capacity 440 volts, 50 Hz, 3 phase Make: L&T/BCH/Siemens
M&L for replament of old/unserviceable compressor oil SERVO FRIZ F 68 of Indian oil or equivalent in BPCL/HPCL complete all as specified and directed by Engr-in-charge.
M&L for replacement of old/unserviceable water thermometer 0 to 30 degree Centigrade including necessary connections/testing complete all as specified and directed by Engr-in-charge.
M&L for replacement of old/unserviceable analog type electronic timer suitable for 95 TR Cap AC Plant at CHNC including necessary connections, testing complete all as specified and directed by Engr-in-charge. Make: L&T/C&S/Seimens/BCH
M&L for replacement of old/unserviceable analog type electronic timer suitable for 12.5 TR Cap AC Plant at 37 AMSD including necessary connections, testing complete all as specified and directed by Engr-in-charge. Make: L&T/C&S/Seimens/BCH
M&L for replacement of old/unserviceable temperature control thermostat +10 degree Centigrade for cut in/cut off system for any capacity of existing AC Plant including also providing copper wiring with 1.5sqmm 8 core flexible copper wire from AHU to compressor gauge panel including necessary connections, testing complete all as specified and directed by Engr-in-charge. Make: Honeywell/Ranco/danfoss
Taking out of old/unserviceable butterfly valve from existing pipe line and S&F new butterfly valve of size 80mm, made out of mild steel including necessary modification of existing pipe line and replacement of falnges with new bolts and nuts etc complete replacement of flanges with new bolts and nuts including all connected works complete all as specified and directed by Engr-in-charge. Make: Advance /Audco/Kirloskar/Neta
Taking out of old/unserviceable butterfly valve from existing pipe line and S&F new butterfly valve of size 50mm, made out of mild steel including necessary modification of existing pipe line and replacement of falnges with new bolts and nuts etc complete replacement of flanges with new bolts and nuts including all connected works complete all as specified and directed by Engr-in-charge. Make: Advance /Audco/Kirloskar/Neta
Taking out of old/unserviceable butterfly valve from existing pipe line and S&F new butterfly valve of size 100mm, made out of mild steel including necessary modification of existing pipe line and replacement of falnges with new bolts and nuts etc complete replacement of flanges with new bolts and nuts including all connected works complete all as specified and directed by Engr-in-charge. Make: Advance /Audco/Kirloskar/Neta
S&F in replacement syphon connection of half inch size made out of GI pipe with SS coating suitable for fixing of existing pressure gauge including stop cock of suitable size and all minor items and taking down old unserviceble complete all as specified and directed by Engr-in-charge.
M&L for replacement of old/unserviceable anti freeze thermostat for chillar 2 degree to 12 degree and 5 degree to 25 degree to cut off the compressor load including making necessary electical wiring and connections, testing complete all as specified and directed by Engr-in-charge. Make: Ranco/Danfoss/Johnson controls
S&F in replacement meter gauge panel made out of 16 SWG MS sheet including all connection with suitable size of copper wire, copper tube flare nuts adopters etc and also including all type of cut outs alongwith contactor complete all as specified and directed by Engr-in-charge.
Taking out of side covers of existing cooling tower of 95 TR capacity carefully without any damage to existing items and remove the unserviceble bearing housing assembly complete with fan blade and hub etc complete all as specified and directed by Engr-in-charge.
S&F bearing housing assembly complete 2 Nos tapper bearing fixed with extended shaft suitable for cooling tower of 95 TR capacity etc complete all as specified and directed by Engr-in-charge.
S&F aluminium hub assembly made out of Aluminium casting with fan blade assembly suitable for 95 TR capacity cooling tower inlcuding testing etc including taking out old unserviceble complete all as specified and directed by Engr-in-charge.
S&F tapper type pulley (fly wheel) of size 95 TR cooling tower capacity tower shaft including provision of bolt, nuts and washers including taking out old unserviceble complete all as specified and directed by Engr-in-charge.
Dismantling of side cover existing cooling tower carefully without any damaging to any parts and removing old unserviceable PVC honey comb fills as per existing including replacement of unserviceble PVC Nozzels refixing all side covers of cooling tower after S&F of PVC honey comb fills suitable for 95 TR Capacity Cooling tower at CHNC complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 33 here-in-before but 12.5 TR Capacity Cooling tower at 37 AMSD.
S&F of cast iron pot strainer of 80mm/100mm dia including flanges, nut, bolts of suitable size including taking down old unserviceable strainer complete all as specified and directed by Engr-in-charge. Make: Neta/Loader/Universal
Supply, fixing and welding medium grade GI tubing of size 50mm dia with necessary MS elbows, bends, sockets, flanges etc including taking down of old unserviceable pipe lines etc complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 36 here-in-before but 80 mm dia complete all as specified and directed by Engr-in-charge.
S&F water pressure gauge 0 to 10 Kg 2"/4 dia suitable for condenser / chillar water line including taking down old unserviceable pressure gauge etc complete all as specified and directed by Engr-in-charge.
S&F of cooling tower sprinkler made out of aluminium suitable for 95 TR capacity cooling tower including taking down old unserviceable sprinkler complete all as specified and directed by Engr-in-charge.
S&F in replacement foam insulation of 25mm thick over the surface of MS Chillar Pipe Line and ducting of AHU and provide the cement with wiremesh between foam insulaiton and MS Pipe complete all as specified and directed by Engr-in-charge.
Supply, laying, connecting and testing of armoured copper cable of 35 sqmm Single core laying on ground/cable duct/on wall alognwith suitable support on cable duct/on wall including taking down existing cable complete all as specified and directed by Engr-in-charge.
Supply and charging of Refrigerant gas R-22 complete all as specified and directed by Engr-in-charge. Make: Refron/Fluoron/Metron
Supply and charging of Refrigerant gas 407C complete all as specified and directed by Engr-in-charge. Make: Refron/Fluoron/Metron
Supply and charging of Refrigerant gas 134a complete all as specified and directed by Engr-in-charge. Make: Refron/Fluoron/Metron
Supply and charging of Refrigerant gas 410 complete all as specified and directed by Engr-in-charge. Make: Refron/Fluoron/Metron
Taking out old / unserviceable MCCB 400 Amps from the existing panel after removing all electrical connections, unscrewing and S&F MCCB four pole 415 volts, 50 Hz, 400 Amps with adjustable Thermal & Magnetic type of breaking capacity 36 KA 'Ics =100% Icu, all as specified. Make: HPL/L&T/Havelles
Taking out old / unserviceable MCCB 200 Amps from the existing panel after removing all electrical connections, unscrewing and S&F MCCB four pole 415 volts, 50 Hz, 200 Amps with adjustable Thermal & Magnetic type of breaking capacity 36 KA 'Ics =100% Icu, complete all as specified and directed by Engr-in-charge. Make: HPL/L&T/Havelles
S&F removable type factory made metallic pre filters of 20 micron of standard size with GI frame both side including taking down old unserviceable complete all as specified and directed by Engr-in-charge. Make: Aerosol/Dyna/Maf/Zonflower
S&F factory made high performance bag filters of 99 micron down to 5 micron of standard size with multiple pockets and self supporting filters bags with MS/GI anodised aluminium frame suitable for central AC Plant including replacement of bolts and nuts including taking down unserviceable complete all as specified and directed by Engr-in-charge. Make: Aerosol/Dyna/Maf/Zonflower
Supply and replacement of condenser safety valve up to 400 PSI scaled of any size confirming of ISI including evacuating of refrigerant gas complete all as specified and directed by Engr-in-charge.
LUXMI ELECTRONIC WORKS
VARDHMAN INTERNATIONAL
Electromech Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .