Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC 1ST FLOOR RAGHUNATH MARKET NEAR TELEPHONE EXCHANGE PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | ₹1.2 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹1.2 Cr+₹2.8 L (2.40%)Rejected-Finance 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | ₹1.2 Cr+₹2.8 L (2.40%) | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 3 | L3₹1.3 Cr+₹9.8 L (8.30%)Rejected-Finance 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | ₹1.3 Cr+₹9.8 L (8.30%) | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 4 | L4₹1.3 Cr+₹15.0 L (12.8%)Rejected-Finance | ₹1.3 Cr+₹15.0 L (12.8%) | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 5 | L5₹1.4 Cr+₹21.0 L (17.8%)Rejected-Finance 13 29 304 IIIRD FLOOR EAST PATEL NAGAR OPP HOTEL SIDDARATHA NEW DELHI 110008 | WEST | DELHI | 110008 | ₹1.4 Cr+₹21.0 L (17.8%) | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | Leo Network power systems L5 | M/s Trade Linker Associates L4 | Shekhar Enterprises L7 | vijay builders L2 | Vijaypower Generators Limited L3 | JCC ENGINEERS PRIVATE LIMITED L1 | SAGGI ELECTRIC COMPANY L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing & commissioning of factory assembled silent Diesel Engine driven generating set 1500 RPM of capacity 320 KVA, 3 phase, 4 wire, 415 volt, 0.8 PF (MSL complete with control panel including integrated powder coated accoustic enclosure as per CPCB-IV regulations and duly certified by agencies / labs designated by CPCB-IV for noise and sound pollution level, etc floor mounted including PCC foundation as per manufacturer's instructions complete all as specified and directed and comprising of the following :- (Note: main power house) DIESEL ENGINE required capacity for driving 320 KVA alternator multi cylinder, vertical type, 4 stroke, water cooled, electric start conforming to IS : 10001/10002/BS-5514 for continuous running capable of taking 10% overload for one hour in 12 hours complete and comprising of the following :-
(i) Radiator cooling
(ii) Radiator fan with guard
(iii) Flywheel with starter ring
(iv) Air cleaner oil bath type
(v) Vacuum indicator
(vi) Electronic governor class 1A
(vii) Exhaust silencer
(viii) Fuel filters & fuel pipelines including fuel flow meter
(ix) Fuel injection pump (FIP)
(x) Fan & water pump assembly
(xi) Lub oil filter & Pump
(xii) Oil filter
(xiii) Exhaust gas driven turbo charger
(xiv) Lub oil cooler
(xv) Engine maintenance manual with spare parts list
(xvi) Suitably designed accoustic enclosure as per CPCB-IV regulations. | 1 | Each | 37,42,960 ₹37,42,960 | 39,25,000 ₹39,25,000 | 39,50,000 ₹39,50,000 | 34,00,000 ₹34,00,000 | 35,58,000 ₹35,58,000 | 31,55,555 ₹31,55,555 Lowest | 35,26,600 ₹35,26,600 |
| 1.01(xvii) Engine safety shut down system against low lub oil pressure and high water pressure. (xviii) Electric starting system with battery charging alternator and axial type starter motor including adequate number as per manufacturers design of high capacity maintenance free lead acid battery 12 volts 140 AH including interconnecting cables/ leads with terminals complete with starting/ stopping switch, volt meter etc - 01 Set. (A) ENGINE INSTRUMENT PANEL digital type indicating the following : (i) Starting switch on/off (ii) Water temp guage (iii) Hour meter cum RPM indicator (iv) Lub oil pressure (v) Lub oil temperature (vi) Battery charging meter (vii) Safety alarm against high water temp and lub oil pressure (B) ALTERNATOR Shall be self excited, self regulated, brushless for 320 KVA continuous operation at the speed of 1500 RPM at 415 volts, 50Hz , three phase four wire system with advance electric voltage regulator to ensure high voltage accuracy with ± 1% with class "H" insulation and SPDP enclosure directly coupled with engine through flexible coupling and confirming IS- 13364 complete - 1 No. (C) Common fabricated base frame for engine & alternator made from structural channel, jerk proof PCC 1:2:4 type B1 foundation including adequate number of suitable anti-vibration pads all as per the recommendation of the manufacture- 01 No (NOTE:- Cost of suitable size of PCC foundation is deemed to be included in the unit rate quoted by the contractor. | ||||||||||
| 1.02(D) Fuel tank fabricated out of 14 SWG MS sheet of capacity not less than 8 hrs continuous operation, inside canopy, with fuel level guage, drain plug, locking arrengements, etc with & including GI pipe connections duly laid as per engineering practice complete. (E) AMF CONTROL PANEL Supply, fabrication, fixing commissioning and testing, factory made, floor mounted, cubical automatic mains failure panel suitable for 320 KVA DG set, fabricated using 14 guage thick CRCA sheet, powder coated painting, suitable rated bus bar, internal wiring with control fuse, provn of connecting incoming & outgoing leads/bus bas as approved with and including the following accessories as under:- (F) Master switch for auto/ manual/ reset/ off - 01 No (ii) Ammeter digital type 96x96 mm to read 0 - 400 amps with CTs 1 set of 3, aux supply 230 volts, AC, accuracy class 1.0 (iii) Voltmeter digital type, 96 x 96 mm to read 0 - 500 volts aux supply 230 volts, AC, accuracy class 1.0 (iv) Digital frequency meter -01 No. aux supply 230 volts, AC (G) Push button start, stop/ reset - 01 No (v) Set of lamp for indicating load on , low pressure, high cylinder temperature, load on mains, set fails to start, low oil pressure . | ||||||||||
| 2.00 | Supply, installation, testing & commissioning of factory assembled silent Diesel Engine driven generating set 1500 RPM of capacity 160 KVA, 3 phase, 4 wire, 415 volt, 0.8 PF (MSL complete with control panel including integrated powder coated accoustic enclosure as per CPCB-IV regulations and duly certified by agencies / labs designated by CPCB-IV for noise and sound pollution level, etc floor mounted including PCC foundation as per manufacturer's instructions complete all as specified and directed and comprising of the following :- DIESEL ENGINE required capacity for driving 160 KVA alternator multi cylinder, vertical type, 4 stroke, water cooled, electric start conforming to IS : 10001/10002/BS-5514 for continuous running capable of taking 10% overload for one hour in 12 hours complete and comprising of the following :-
(i) Radiator cooling
(ii) Radiator fan with guard
(iii) Flywheel with starter ring
(iv) Air cleaner oil bath type
(v) Vacuum indicator
(vi) Electronic governor class 1A
(vii) Exhaust silencer
(viii) Fuel filters & fuel pipelines including fuel flow meter
(ix) Fuel injection pump (FIP)
(x) Fan & water pump assembly
(xi) Lub oil filter & Pump
(xii) Oil filter
(xiii) Exhaust gas driven turbo charger
(xiv) Lub oil cooler
(xv) Engine maintenance manual with spare parts list
(xvi) Suitably designed accoustic enclosure as per CPCB-IV regulations.
(xvii) Engine safety shut down system against low lub oil pressure and high water pressure | 1 | Each | 22,83,633 ₹22,83,633 | 21,55,000 ₹21,55,000 | 24,00,000 ₹24,00,000 | 20,00,000 ₹20,00,000 | 20,55,000 ₹20,55,000 | 19,95,555 ₹19,95,555 Lowest | 20,94,400 ₹20,94,400 |
| 2.01(xviii) Electric starting system with battery charging alternator and axial type starter motor including adequate numberas per manufacturers design of high capacity maintenance free lead acid battery 12 volts 140 AH including interconnecting cables/ leads with terminals complete with starting/ stopping switch, volt meter etc - 01 Set. (A) ENGINE INSTRUMENT PANEL digital type indicating the following : (i) Starting switch on/off (ii) Water temp guage (iii) Hour meter cum RPM indicator (iv) Lub oil pressure (v) Lub oil temperature (vi) Battery charging meter (vii) Safety alarm against high water temp and lub oil pressure (B) ALTERNATOR Shall be self excited, self regulated, brushless for 160 KVA continuous operation at the speed of 1500 RPM at 415 volts, 50Hz , three phase four wire system with advance electric voltage regulator to ensure high voltage accuracy with ± 1% with class "H" insulation and SPDP enclosure directly coupled with engine through flexible coupling and confirming IS- 13364 complete - 1 No. (C) Common fabricated base frame for engine & alternator made from structural channel, jerk proof PCC 1:2:4 type B1 foundation including adequate number of suitable anti-vibration pads all as per the recommendation of the manufacture- 01 No (NOTE:- Cost of suitable size of PCC foundation is deemed to be included in the unit rate quoted by the contractor. | ||||||||||
| 2.02(D) Fuel tank fabricated out of 14 SWG MS sheet of capacity not less than 8 hrs continuous operation, inside canopy, with fuel level guage, drain plug, locking arrengements, etc with & including GI pipe connections duly laid as per engineering practice complete. (E) AMF CONTROL PANEL Supply, fabrication, fixing commissioning and testing, factory made, floor mounted, cubical automatic mains failure panel suitable for 160 KVA DG set, fabricated using 14 guage thick CRCA sheet, powder coated painting, suitable rated bus bar, internal wiring with control fuse, provn of connecting incoming & outgoing leads/bus bas as approved with and including the following accessories as under:- (F) Master switch for auto/ manual/ reset/ off - 01 No (ii) Ammeter digital type 96x96 mm to read 0 - 400 amps with CTs 1 set of 3, aux supply 230 volts, AC, accuracy class 1.0 (iii) Voltmeter digital type, 96 x 96 mm to read 0 - 500 volts aux supply 230 volts, AC, accuracy class 1.0 (iv) Digital frequency meter -01 No. aux supply 230 volts, AC (G) Push button start, stop/ reset - 01 No (v) Set of lamp for indicating load on , low pressure, high cylinder temperature, load on mains, set fails to start, low oil pressure . | ||||||||||
| 3.00 | Supply, installation, testing & commissioning of factory assembled silent Diesel Engine driven generating set 1500 RPM of capacity 125KVA, 3 phase, 4 wire, 415 volt, 0.8 PF (MSL complete with control panel including integrated powder coated accoustic enclosure as per CPCB-IV regulations and duly certified by agencies / labs designated by CPCB-IV for noise and sound pollution level, etc floor mounted including PCC foundation as per manufacturer's instructions complete all as specified and directed and comprising of the following :- DIESEL ENGINE required capacity for driving 125 KVA alternator multi cylinder, vertical type, 4 stroke, water cooled, electric start conforming to IS : 10001/10002/BS-5514 for continuous running capable of taking 10% overload for one hour in 12 hours complete and comprising of the following :-
(i) Radiator cooling
(ii) Radiator fan with guard
(iii) Flywheel with starter ring
(iv) Air cleaner oil bath type
(v) Vacuum indicator
(vi) Electronic governor class 1A
(vii) Exhaust silencer
(viii) Fuel filters & fuel pipelines including fuel flow meter
(ix) Fuel injection pump (FIP)
(x) Fan & water pump assembly
(xi) Lub oil filter & Pump
(xii) Oil filter
(xiii) Exhaust gas driven turbo charger
(xiv) Lub oil cooler
(xv) Engine maintenance manual with spare parts list
(xvi) Suitably designed accoustic enclosure as per CPCB-IV regulations.
(xvii) Engine safety shut down system against low lub oil pressure and high water pressure | 1 | Each | 17,05,800 ₹17,05,800 | 15,70,000 ₹15,70,000 | 18,50,000 ₹18,50,000 | 15,00,000 ₹15,00,000 | 15,95,001 ₹15,95,001 | 14,55,555 ₹14,55,555 Lowest | 18,17,200 ₹18,17,200 |
| 3.01(xviii) Electric starting system with battery charging alternator and axial type starter motor including adequate number as per manufacturers design of high capacity maintenance free lead acid battery 12 volts 140 AH including interconnecting cables/ leads with terminals complete with starting/ stopping switch, volt meter etc - 01 Set. (A) ENGINE INSTRUMENT PANEL digital type indicating the following : (i) Starting switch on/off (ii) Water temp guage (iii) Hour meter cum RPM indicator (iv) Lub oil pressure (v) Lub oil temperature (vi) Battery charging meter (vii) Safety alarm against high water temp and lub oil pressure (B) ALTERNATOR Shall be self excited, self regulated, brushless for 125 KVA continuous operation at the speed of 1500 RPM at 415 volts, 50Hz , three phase four wire system with advance electric voltage regulator to ensure high voltage accuracy with ± 1% with class "H" insulation and SPDP enclosure directly coupled with engine through flexible coupling and confirming IS- 13364 complete - 1 No. (C) Common fabricated base frame for engine & alternator made from structural channel, jerk proof PCC 1:2:4 type B1 foundation including adequate number of suitable anti-vibration pads all as per the recommendation of the manufacture- 01 No NOTE:- Cost of suitable size of PCC foundation is deemed to be included in the unit rate quoted by the contractor. | ||||||||||
| 3.02(D) Fuel tank fabricated out of 14 SWG MS sheet of capacity not less than 8 hrs continuous operation, inside canopy, with fuel level guage, drain plug, locking arrengements, etc with & including GI pipe connections duly laid as per engineering practice complete. (E) AMF CONTROL PANEL Supply, fabrication, fixing commissioning and testing, factory made, floor mounted, cubical automatic mains failure panel suitable for 125 KVA DG set, fabricated using 14 guage thick CRCA sheet, powder coated painting, suitable rated bus bar, internal wiring with control fuse, provn of connecting incoming & outgoing leads/bus bas as approved with and including the following accessories as under:- (F) Master switch for auto/ manual/ reset/ off - 01 No (ii) Ammeter digital type 96x96 mm to read 0 - 400 amps with CTs 1 set of 3, aux supply 230 volts, AC, accuracy class 1.0 (iii) Voltmeter digital type, 96 x 96 mm to read 0 - 500 volts aux supply 230 volts, AC, accuracy class 1.0 (iv) Digital frequency meter -01 No. aux supply 230 volts, AC (G) Push button start, stop/ reset - 01 No (v) Set of lamp for indicating load on , low pressure, high cylinder temperature, load on mains, set fails to start, low oil pressure . | ||||||||||
| 4.00 | Supply, installation, testing & commissioning of factory assembled silent Diesel Engine driven generating set 1500 RPM of capacity 100 KVA, 3 phase, 4 wire, 415 volt, 0.8 PF (MSL complete with control panel including integrated powder coated accoustic enclosure as per CPCB-IV regulations and duly certified by agencies / labs designated by CPCB-IV for noise and sound pollution level, etc floor mounted including PCC foundation as per manufacturer's instructions complete all as specified and directed and comprising of the following :- DIESEL ENGINE required capacity for driving 100 KVA alternator multi cylinder, vertical type, 4 stroke, water cooled, electric start conforming to IS : 10001/10002/BS-5514 for continuous running capable of taking 10% overload for one hour in 12 hours complete and comprising of the following :-
(i) Radiator cooling
(ii) Radiator fan with guard
(iii) Flywheel with starter ring
(iv) Air cleaner oil bath type
(v) Vacuum indicator
(vi) Electronic governor class 1A
(vii) Exhaust silencer
(viii) Fuel filters & fuel pipelines including fuel flow meter
(ix) Fuel injection pump (FIP)
(x) Fan & water pump assembly
(xi) Lub oil filter & Pump
(xii) Oil filter
(xiii) Exhaust gas driven turbo charger
(xiv) Lub oil cooler
(xv) Engine maintenance manual with spare parts list
(xvi) Suitably designed accoustic enclosure as per CPCB-IV regulations.
(xvii) Engine safety shut down system against low lub oil pressure and high water pressure | 1 | Each | 16,48,560 ₹16,48,560 | 15,30,000 ₹15,30,000 | 18,00,000 ₹18,00,000 | 14,00,000 ₹14,00,000 | 14,82,000 ₹14,82,000 | 13,85,555 ₹13,85,555 Lowest | 15,01,500 ₹15,01,500 |
Tender Value
₹1.4 Cr
EMD Value
₹2.9 L
Closing Date
4 Mar 2026, 6:00 pmClosed
HQ CWE AF Jammu
HQ CWE (AF) Jammu Air Force Station Jammu
CA NO CWEAFJ-51/2025-26 SPECIAL REPAIR/REPLACEMENT OF BER DG SETS CERTAIN E/M INSTALLATION AND ALLIED WORKS AT AIR FORCE STATION PATHANKOT UNDER GE (AF) PATHANKOT
2026_MES_751145_1
CA NO CWEAFJ-51/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Pathankot
As per NIT and Tender Document
9 documents required · 9 mandatory
₹1,000
GE AF Pathankot
₹2.9 L
Yes
3 Jul 2026
3 Feb 2026
6 Mar 2026
3 Feb 2026
4 Mar 2026
24 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, testing & commissioning of factory assembled silent Diesel Engine driven generating set 1500 RPM of capacity 320 KVA, 3 phase, 4 wire, 415 volt, 0.8 PF (MSL complete with control panel including integrated powder coated accoustic enclosure as per CPCB regulations and duly certified by agencies / labs designated by CPCB for noise and sound pollution level, etc floor mounted including PCC foundation as per manufacturer's instructions complete all as specified and directed and comprising of the following :- (Note: main power house) DIESEL ENGINE required capacity for driving 320 KVA alternator multi cylinder, vertical type, 4 stroke, water cooled, electric start conforming to IS : 10001/10002/BS-5514 for continuous running capable of taking 10% overload for one hour in 12 hours complete and comprising of the following :-
(i) Radiator cooling
(ii) Radiator fan with guard
(iii) Flywheel with starter ring
(iv) Air cleaner oil bath type
(v) Vacuum indicator
(vi) Electronic governor class 1A
(vii) Exhaust silencer
(viii) Fuel filters & fuel pipelines including fuel flow meter
(ix) Fuel injection pump (FIP)
(x) Fan & water pump assembly
(xi) Lub oil filter & Pump
(xii) Oil filter
(xiii) Exhaust gas driven turbo charger
(xiv) Lub oil cooler
(xv) Engine maintenance manual with spare parts list
(xvi) Suitably designed accoustic enclosure as per CPCB regulations. | 1 | Each | 1.25 | ₹1.25 |
| 1.01 | (xvii) Engine safety shut down system against low lub oil pressure and high water pressure.
(xviii) Electric starting system with battery charging alternator and axial type starter motor including adequate number as per manufacturers design of high capacity maintenance free lead acid battery 12 volts 140 AH including interconnecting cables/ leads with terminals complete with starting/ stopping switch, volt meter etc - 01 Set. (A) ENGINE INSTRUMENT PANEL digital type indicating the following :
(i) Starting switch on/off
(ii) Water temp guage
(iii) Hour meter cum RPM indicator
(iv) Lub oil pressure
(v) Lub oil temperature
(vi) Battery charging meter
(vii) Safety alarm against high water temp and lub oil pressure
(B) ALTERNATOR Shall be self excited, self regulated, brushless for 320 KVA continuous operation at the speed of 1500 RPM at 415 volts, 50Hz , three phase four wire system with advance electric voltage regulator to ensure high voltage accuracy with ± 1% with class "H" insulation and SPDP enclosure directly coupled with engine through flexible coupling and confirming IS- 13364 complete - 1 No.
(C) Common fabricated base frame for engine & alternator made from structural channel, jerk proof PCC 1:2:4 type B1 foundation including adequate number of suitable anti-vibration pads all as per the recommendation of the manufacture- 01 No
(NOTE:- Cost of suitable size of PCC foundation is deemed to be included in the unit rate quoted by the contractor. | - | - | - | - |
| 1.02 | (D) Fuel tank fabricated out of 14 SWG MS sheet of capacity not less than 8 hrs continuous operation, inside canopy, with fuel level guage, drain plug, locking arrengements, etc with & including GI pipe connections duly laid as per engineering practice complete.
(E) AMF CONTROL PANEL Supply, fabrication, fixing commissioning and testing, factory made, floor mounted, cubical automatic mains failure panel suitable for 320 KVA DG set, fabricated using 14 guage thick CRCA sheet, powder coated painting, suitable rated bus bar, internal wiring with control fuse, provn of connecting incoming & outgoing leads/bus bas as approved with and including the following accessories as under:-
(F) Master switch for auto/ manual/ reset/ off - 01 No
(ii) Ammeter digital type 96x96 mm to read 0 - 400 amps with CTs 1 set of 3, aux supply 230 volts, AC, accuracy class 1.0
(iii) Voltmeter digital type, 96 x 96 mm to read 0 - 500 volts aux supply 230 volts, AC, accuracy class 1.0
(iv) Digital frequency meter -01 No. aux supply 230 volts, AC (G) Push button start, stop/ reset - 01 No
(v) Set of lamp for indicating load on , low pressure, high cylinder temperature, load on mains, set fails to start, low oil pressure . | - | - | - | - |
| 2 | Supply, installation, testing & commissioning of factory assembled silent Diesel Engine driven generating set 1500 RPM of capacity 160 KVA, 3 phase, 4 wire, 415 volt, 0.8 PF (MSL complete with control panel including integrated powder coated accoustic enclosure as per CPCB regulations and duly certified by agencies / labs designated by CPCB for noise and sound pollution level, etc floor mounted including PCC foundation as per manufacturer's instructions complete all as specified and directed and comprising of the following :- DIESEL ENGINE required capacity for driving 160 KVA alternator multi cylinder, vertical type, 4 stroke, water cooled, electric start conforming to IS : 10001/10002/BS-5514 for continuous running capable of taking 10% overload for one hour in 12 hours complete and comprising of the following :-
(i) Radiator cooling
(ii) Radiator fan with guard
(iii) Flywheel with starter ring
(iv) Air cleaner oil bath type
(v) Vacuum indicator
(vi) Electronic governor class 1A
(vii) Exhaust silencer
(viii) Fuel filters & fuel pipelines including fuel flow meter
(ix) Fuel injection pump (FIP)
(x) Fan & water pump assembly
(xi) Lub oil filter & Pump
(xii) Oil filter
(xiii) Exhaust gas driven turbo charger
(xiv) Lub oil cooler
(xv) Engine maintenance manual with spare parts list
(xvi) Suitably designed accoustic enclosure as per CPCB regulations.
(xvii) Engine safety shut down system against low lub oil pressure and high water pressure | 1 | Each | -1.25 | - |
| 2.01 | (xviii) Electric starting system with battery charging alternator and axial type starter motor including adequate numberas per manufacturers design of high capacity maintenance free lead acid battery 12 volts 140 AH including interconnecting cables/ leads with terminals complete with starting/ stopping switch, volt meter etc - 01 Set. (A) ENGINE INSTRUMENT PANEL digital type indicating the following :
(i) Starting switch on/off
(ii) Water temp guage
(iii) Hour meter cum RPM indicator
(iv) Lub oil pressure
(v) Lub oil temperature
(vi) Battery charging meter
(vii) Safety alarm against high water temp and lub oil pressure
(B) ALTERNATOR Shall be self excited, self regulated, brushless for 160 KVA continuous operation at the speed of 1500 RPM at 415 volts, 50Hz , three phase four wire system with advance electric voltage regulator to ensure high voltage accuracy with ± 1% with class "H" insulation and SPDP enclosure directly coupled with engine through flexible coupling and confirming IS- 13364 complete - 1 No.
(C) Common fabricated base frame for engine & alternator made from structural channel, jerk proof PCC 1:2:4 type B1 foundation including adequate number of suitable anti-vibration pads all as per the recommendation of the manufacture- 01 No
(NOTE:- Cost of suitable size of PCC foundation is deemed to be included in the unit rate quoted by the contractor. | - | - | - | - |
| 2.02 | (D) Fuel tank fabricated out of 14 SWG MS sheet of capacity not less than 8 hrs continuous operation, inside canopy, with fuel level guage, drain plug, locking arrengements, etc with & including GI pipe connections duly laid as per engineering practice complete.
(E) AMF CONTROL PANEL Supply, fabrication, fixing commissioning and testing, factory made, floor mounted, cubical automatic mains failure panel suitable for 160 KVA DG set, fabricated using 14 guage thick CRCA sheet, powder coated painting, suitable rated bus bar, internal wiring with control fuse, provn of connecting incoming & outgoing leads/bus bas as approved with and including the following accessories as under:-
(F) Master switch for auto/ manual/ reset/ off - 01 No
(ii) Ammeter digital type 96x96 mm to read 0 - 400 amps with CTs 1 set of 3, aux supply 230 volts, AC, accuracy class 1.0
(iii) Voltmeter digital type, 96 x 96 mm to read 0 - 500 volts aux supply 230 volts, AC, accuracy class 1.0
(iv) Digital frequency meter -01 No. aux supply 230 volts, AC (G) Push button start, stop/ reset - 01 No
(v) Set of lamp for indicating load on , low pressure, high cylinder temperature, load on mains, set fails to start, low oil pressure . | - | - | - | - |
| 3 | Supply, installation, testing & commissioning of factory assembled silent Diesel Engine driven generating set 1500 RPM of capacity 125KVA, 3 phase, 4 wire, 415 volt, 0.8 PF (MSL complete with control panel including integrated powder coated accoustic enclosure as per CPCB regulations and duly certified by agencies / labs designated by CPCB for noise and sound pollution level, etc floor mounted including PCC foundation as per manufacturer's instructions complete all as specified and directed and comprising of the following :- DIESEL ENGINE required capacity for driving 125 KVA alternator multi cylinder, vertical type, 4 stroke, water cooled, electric start conforming to IS : 10001/10002/BS-5514 for continuous running capable of taking 10% overload for one hour in 12 hours complete and comprising of the following :-
(i) Radiator cooling
(ii) Radiator fan with guard
(iii) Flywheel with starter ring
(iv) Air cleaner oil bath type
(v) Vacuum indicator
(vi) Electronic governor class 1A
(vii) Exhaust silencer
(viii) Fuel filters & fuel pipelines including fuel flow meter
(ix) Fuel injection pump (FIP)
(x) Fan & water pump assembly
(xi) Lub oil filter & Pump
(xii) Oil filter
(xiii) Exhaust gas driven turbo charger
(xiv) Lub oil cooler
(xv) Engine maintenance manual with spare parts list
(xvi) Suitably designed accoustic enclosure as per CPCB regulations.
(xvii) Engine safety shut down system against low lub oil pressure and high water pressure | 1 | Each | -2.5 | - |
| 3.01 | (xviii) Electric starting system with battery charging alternator and axial type starter motor including adequate number as per manufacturers design of high capacity maintenance free lead acid battery 12 volts 140 AH including interconnecting cables/ leads with terminals complete with starting/ stopping switch, volt meter etc - 01 Set. (A) ENGINE INSTRUMENT PANEL digital type indicating the following :
(i) Starting switch on/off
(ii) Water temp guage
(iii) Hour meter cum RPM indicator
(iv) Lub oil pressure
(v) Lub oil temperature
(vi) Battery charging meter
(vii) Safety alarm against high water temp and lub oil pressure
(B) ALTERNATOR Shall be self excited, self regulated, brushless for 125 KVA continuous operation at the speed of 1500 RPM at 415 volts, 50Hz , three phase four wire system with advance electric voltage regulator to ensure high voltage accuracy with ± 1% with class "H" insulation and SPDP enclosure directly coupled with engine through flexible coupling and confirming IS- 13364 complete - 1 No.
(C) Common fabricated base frame for engine & alternator made from structural channel, jerk proof PCC 1:2:4 type B1 foundation including adequate number of suitable anti-vibration pads all as per the recommendation of the manufacture- 01 No
NOTE:- Cost of suitable size of PCC foundation is deemed to be included in the unit rate quoted by the contractor. | - | - | - | - |
| 3.02 | (D) Fuel tank fabricated out of 14 SWG MS sheet of capacity not less than 8 hrs continuous operation, inside canopy, with fuel level guage, drain plug, locking arrengements, etc with & including GI pipe connections duly laid as per engineering practice complete.
(E) AMF CONTROL PANEL Supply, fabrication, fixing commissioning and testing, factory made, floor mounted, cubical automatic mains failure panel suitable for 125 KVA DG set, fabricated using 14 guage thick CRCA sheet, powder coated painting, suitable rated bus bar, internal wiring with control fuse, provn of connecting incoming & outgoing leads/bus bas as approved with and including the following accessories as under:-
(F) Master switch for auto/ manual/ reset/ off - 01 No
(ii) Ammeter digital type 96x96 mm to read 0 - 400 amps with CTs 1 set of 3, aux supply 230 volts, AC, accuracy class 1.0
(iii) Voltmeter digital type, 96 x 96 mm to read 0 - 500 volts aux supply 230 volts, AC, accuracy class 1.0
(iv) Digital frequency meter -01 No. aux supply 230 volts, AC (G) Push button start, stop/ reset - 01 No
(v) Set of lamp for indicating load on , low pressure, high cylinder temperature, load on mains, set fails to start, low oil pressure . | - | - | - | - |
| 4 | Supply, installation, testing & commissioning of factory assembled silent Diesel Engine driven generating set 1500 RPM of capacity 100 KVA, 3 phase, 4 wire, 415 volt, 0.8 PF (MSL complete with control panel including integrated powder coated accoustic enclosure as per CPCB regulations and duly certified by agencies / labs designated by CPCB for noise and sound pollution level, etc floor mounted including PCC foundation as per manufacturer's instructions complete all as specified and directed and comprising of the following :- DIESEL ENGINE required capacity for driving 100 KVA alternator multi cylinder, vertical type, 4 stroke, water cooled, electric start conforming to IS : 10001/10002/BS-5514 for continuous running capable of taking 10% overload for one hour in 12 hours complete and comprising of the following :-
(i) Radiator cooling
(ii) Radiator fan with guard
(iii) Flywheel with starter ring
(iv) Air cleaner oil bath type
(v) Vacuum indicator
(vi) Electronic governor class 1A
(vii) Exhaust silencer
(viii) Fuel filters & fuel pipelines including fuel flow meter
(ix) Fuel injection pump (FIP)
(x) Fan & water pump assembly
(xi) Lub oil filter & Pump
(xii) Oil filter
(xiii) Exhaust gas driven turbo charger
(xiv) Lub oil cooler
(xv) Engine maintenance manual with spare parts list
(xvi) Suitably designed accoustic enclosure as per CPCB regulations.
(xvii) Engine safety shut down system against low lub oil pressure and high water pressure | 1 | Each | -3.75 | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
BOQ_841274.xls
BOQ • 0.77 MB
51TENDERDOCUMENT.pdf
Tender Documents • 1.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .