| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.9 LQualified | L1 | Qualified MSE, MII, Category: OBC | |
| 2 | L2₹27.5 L+₹1.6 L (6.31%)Qualified | L2 | Qualified MSE, MII, Category: General | |
| 3 | Disqualified D 41 NEAR NATARAJ CINEMA GOVIND NAGAR GOVIND NAGAR KANPUR NAGAR UTTAR PRADESH 208006 | KANPUR NAGAR | UTTAR PRADESH | 208006 | - | Disqualified MSE | |
| 4 | Disqualified SHOP NO 6 H NO 191 NEW MOTI NAGAR NEW MOTI NAGAR WEST DELHI DELHI 110015 | WEST DELHI | DELHI | 110015 | - | Disqualified MII |
Tender Value
₹29.8 L
EMD Value
₹59,600
Closing Date
6 Apr 2022, 6:00 pmClosed
Supply and Fix Sluice valve as specified in BOQ item No 01 at Srl Page 18
Supply and Fix Cast Iron Non return valve PN 1 as specified in BOQ item No 02 at Srl Page 19
Supply and Fix Gate valve 50mm Bore as specified in BOQ item No 03 at Srl Page 19
Supply and Fix Foot valve 150mm Bore as specified in BOQ item No 04 at Srl Page 19
Supply and Fix Cast Iron Non return valve PN 4 as specified in BOQ item No 05 at Srl Page 19
Cutting out the winding and Re winding of 3HP Motor as specified in BOQ item No 06 at Srl Page 19
DOL Starter fpr 3 phase motor 440 V upto 3 HP Motor as in replacement as specified in BOQ item No 07 at Srl Page 19
Supply and Fix MCCB 160 Amps 415 volts AC 50Hz 3 pole breaking capacity 36 kA adjustable thermal setting with suitable size of sheet metal enclosure as specified in BOQ item No 08 at Srl Page 20
Supply and Fix MCCB 200 Amps 415 volts AC 50Hz 4 pole breaking capacity 36 kA adjustable thermal setting with suitable size of sheet metal enclosure as specified in BOQ item No 09 at Srl Page 20
Dismantling and taking out faulty analog type Ammeter from LT panel and supply and fixing three phase Ammeter digital type upto 0 to 100 Amps as specified in BOQ item No 10 at Srl Page 20
Dismantling and taking out faulty analog type voltmeter from LT panel or feeder pillar box and Supply and Fix three phase power voltmeter digital type as specified in BOQ item No 11 at Srl Page 21
Supply and fixing only in replacement of PVC insulated three core submersible cable 4 Sqmm complete all as specified and directed as specified in BOQ item No 12 at Srl Page 21
Repair maint of suction sweeper machine including replacement of suction sweeper brush wheel nuts and bolts etc including all defect parts all as specified and directed by Engr-in-Charge
Cleaning inside balance tank including removing deposit sand from inside the tank as specified in BOQ item No 14 at Srl Page 22
Cleaning of diving pool of size 16m x 16m x 6m with nylon brush and cleaning material such as Acid wiper PVC pipe etc with required number of man power as specified in BOQ item No 15 at Srl Page 22
Cleaning of main pool with nylon brush and cleaning material such as Acid wiper PVC pipe etc with
3292833
GEM/2022/B/2078395
Supply and Fix Sluice valve as specified in BOQ item No 01 at Srl Page 18,Supply and Fix Cast Iron
244 days
Uttar Pradesh; Lucknow
Total value wise evaluation
BOQ
11 documents required · 11 mandatory
3 yrs
₹14 L
₹14 L
80%
₹59,600
12 Apr 2022
30 Mar 2022
6 Apr 2022
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Supply and Fix Sluice valve as specified in BOQ item No 01 at Srl Page 18 | For complete decription and specification please refer item no 01 of Schedule A Item rate BOQ specified at Srl Page no 18 and relevant clauses as specified in tender document | 4 | Each | AGE2019 | 244 |
| 2 | Supply and Fix Cast Iron Non return valve PN 1 as specified in BOQ item No 02 at Srl Page 19 | For complete decription and specification please refer item no 02 of Schedule A Item rate BOQ specified at Srl Page no 19 and relevant clauses as specified in tender document | 4 | Each | AGE2019 | 244 |
| 3 | Supply and Fix Gate valve 50mm Bore as specified in BOQ item No 03 at Srl Page 19 | For complete decription and specification please refer item no 03 of Schedule A Item rate BOQ specified at Srl Page no 19 and relevant clauses as specified in tender document | 3 | Each | AGE2019 | 244 |
| 4 | Supply and Fix Foot valve 150mm Bore as specified in BOQ item No 04 at Srl Page 19 | For complete decription and specification please refer item no 04 of Schedule A Item rate BOQ specified at Srl Page no 19 and relevant clauses as specified in tender document | 2 | Each | AGE2019 | 244 |
| 5 | Supply and Fix Cast Iron Non return valve PN 4 as specified in BOQ item No 05 at Srl Page 19 | For complete decription and specification please refer item no 05 of Schedule A Item rate BOQ specified at Srl Page no 19 and relevant clauses as specified in tender document | 2 | Each | AGE2019 | 244 |
| 6 | Cutting out the winding and Re winding of 3HP Motor as specified in BOQ item No 06 at Srl Page 19 | For complete decription and specification please refer item no 06 of Schedule A Item rate BOQ specified at Srl Page no 19 and relevant clauses as specified in tender document | 2 | Each Job | AGE2019 | 244 |
| 7 | DOL Starter fpr 3 phase motor 440 V upto 3 HP Motor as in replacement as specified in BOQ item No 07 at Srl Page 19 | For complete decription and specification please refer item no 07 of Schedule A Item rate BOQ specified at Srl Page no 19 and relevant clauses as specified in tender document | 2 | Each | AGE2019 | 244 |
| 8 | Supply and Fix MCCB 160 Amps 415 volts AC 50Hz 3 pole breaking capacity 36 kA adjustable thermal setting with suitable size of sheet metal enclosure as specified in BOQ item No 08 at Srl Page 20 | For complete decription and specification please refer item no 08 of Schedule A Item rate BOQ specified at Srl Page no 20 and relevant clauses as specified in tender document | 2 | Each | AGE2019 | 244 |
| 9 | Supply and Fix MCCB 200 Amps 415 volts AC 50Hz 4 pole breaking capacity 36 kA adjustable thermal setting with suitable size of sheet metal enclosure as specified in BOQ item No 09 at Srl Page 20 | For complete decription and specification please refer item no 09 of Schedule A Item rate BOQ specified at Srl Page no 20 and relevant clauses as specified in tender document | 2 | Each | AGE2019 | 244 |
| 10 | Dismantling and taking out faulty analog type Ammeter from LT panel and supply and fixing three phase Ammeter digital type upto 0 to 100 Amps as specified in BOQ item No 10 at Srl Page 20 | For complete decription and specification please refer item no 10 of Schedule A Item rate BOQ specified at Srl Page no 20 and relevant clauses as specified in tender document | 2 | Each | AGE2019 | 244 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_3292833.pdf
GEM_BID
t85tender_2022-03-30-17-10-54_4ef080187ba86774c16ca57a0169958a.pdf
BOQ
t85boqgem_2022-03-30-17-10-54_a9b57d6a8b7c9f4191fc043e17c61f33.csv
BOQ
termsCondition.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .