Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹17.7 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹20.0 L+₹1.1 L (5.66%)Rejected-AOC | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹25.0 L+₹6.1 L (32.3%)Rejected-AOC | L-3 | Rejected-AOC L-3 |
Tender Value
Refer Docs
EMD Value
₹70,200
Closing Date
3 Sept 2022, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR AND REPLACEMENT OF BnR NATURE WORKS (I.E FLOORING, TILING, PLUMBING ETC), REPAIR TO SECURITY WALLS, GATE, FENCING, DRAIN, PATH AND OTHER MISC WORKS IN SAG, DESIDOC, DGRE, ISSA ETC UNDER GE I RND DELHI
2022_MES_540502_1
GE/RND-43/DLI/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Delhi
Class-D, Cat-a(i)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹70,200
Yes
27 Sept 2022
23 Jul 2022
6 Sept 2022
23 Jul 2022
3 Sept 2022
22 Aug 2022
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for 1st quality non-skid joint free coloured ceramic tiles 7 to 8 mm thick, (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set & jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles including making border in floor as directed, laid over and including 15 mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed
M&L for 1st qaulity non-skid joint free coloured ceramic tiles 7 to 8 mm thick, (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in skirting/dado etc. set & jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles laid over and including 10 mm thick rendering in CM 1:4 complete all as specified and directed
M&L for fully vitrified ceramic tiles 9 to 10 mm thick, in light shade, (Square/rectangular) polished, area of each tile not exceeding 0.36 sqm, in floors etc. set & jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles including making border in floor as directed ,laid over and including 15 mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed Note for item No 02 & 04 :- The floor pattern/design including border & colour of tiles shall be get approved from the GE (I) before execution of work.
M&L for fully vitrified ceramic tiles 9 to 10 mm thick, light shade, (Square/rectangular) polished, area of each tile not exceeding 0.36 sqm, in skirting/dado etc. set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 10 mm thick rendering in CM 1:4 complete all as specified and directed
M&L for 1st quality glazed ceramic coloured tiles of size 300x450x7 mm 350x450x7mm on vertical surface as in skirting/dado set and jointed in neat cement slurry and painted in white or coloured cement to match the surface including fixing of different colour tiles to make a pattern as approved over and including 10 mm thick rendering in CM 1:4 complete all as specified and directed. Note :- The wall pattern/design shall be get approved from the GE (I) before execution of work.
M&L for designer tiles 7-8 mm thick on external faces of wall surfaces over and including 10 mm thick rendering in CM 1:4 complete all as specified and directed .
Dismantling stone slabs,interlocking paver block and Ultra tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar, complete including removing from site out side from MOD land complete all as specified and directed.
M&L for 18 to 20mm thick granite stone slab laid in floor, shelves, cooking platform,pillers,cills etc machine cut bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including necessary grinding, moulding and polishing and bevelling half round edges of stones laid over and including 15 mm thick screed bed or bedding layer in CM 1:6 etc complete all as specified and directed.
M&L 20-25 mm thick machine cut kota stone slab (table rubbed and polished) as in floors/windows cills, steps etc projections etc set and jointed with grey cement slurry mixed with pigment to match the shade of slab including, necessary cutting, rubbing, grinding and mirror polishing and moulding etc laid over & including 15 mm thick screed bed or bedding layer in CM 1:6 complete all as specfied and directed.
Dismantling of wall and ceiling board with frame work of ceiling (Fibre,pulp,insulation etc.) or insulation board /slab/blankets any thickness including cover fillet etc complete all as specified and directed.
M&L for false ceiling using powder coated grid system of GI grid size 600x600mm with main runner 38x24x0.7mm,cross tee 25x24x0.7mm and wall angle 24x24x0.70mm using 12 mm thick fiber insulation boards fitted in the grid, grid system hanges by 3 to 4mm dia G.I wire to purlin, trusses, RCC slab of the roof etc. with hold down clips, butterfly clips, height fixtures etc.complete Including taking down and refixing E/M fixtures/fittings and reconnecting wiring connection complete all as specified and directed.
S&F powder coated Gl frame work for seamless ceiling/wall comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed.
S&F Hangers rod of 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
S&F self designed Gypsum boards 12 mm thick in ceiling fixed with screws as per manufacturer's instructions including jointless finishes with jointing compound and jointing tapes Including taking down and refixing E/M fixtures/fittings and reconnecting wiring connection complete all as specified and directed.
Taking down chowkaths or frames n.exc 1.5 sqm (without taking off shutter from the frame) each complete all as specified and directed.
Taking down chowkaths or frames exc 1.5 sqm but n.exc 4 sqm (without taking off shutter from the frame) each complete all as specified and directed.
S&F powder coated aluminum frame (minimum thickness of powder coating 50 micron) for doors, with one or more rebates including jointing cleat for fixing etc. complete all as specified and directed.
M&L for Powder coated aluminum windows made out of aluminum tubular frame of section 63.5 x 38.10 x 1.6 mm thick and shutter fixed ,sliding or openable horizontal and vertical members of aluminium section 47.50 x 44.45 x1.6 mm thick, aluminum beading, rubber gasket and complete including aluminum fittings such as 03 Nos 100 mm hinges 02 Nos 200 mm tower bolt 01 No 300 mm stay rod and 02 Nos 150 mm handle complete all as specified and directed. Note :- Sheet glass shall be measured and paid separately design and pattern of aluminum windows shall be as approved.
S&F aluminium powder coated section door shutters consisting top rail and style 82.77X44.45X1.60 mm thick bottom and lock rail 150X44.45X1.60 mm including jointing clips,aluminium snap beading,rubber gasket,glazing clips,two aluminium handles of size 200mm,01 No. tower bolt 200 mm 03/04 Nos hinges per leaf complete all as specefied and directed. Note :-Glass and boards shall be measered and paid separately.
M&L aluminium alloy powder coated (50 micron ) anodised for partitions (fixed portion) with extruted built up standard tubular sections /appropriate sections of approved make confirming to IS 733 and IS 1285 fixing with dash fastners of required dia and size including filling up the gaps at junctions at top,bottom and sides with required EPDM rubber/neoprene gasket etc. including aluminium snap beading for glazing /paneling CP brass ,stainless steel screws including taking down old partitions of aluminium complete all as specified and directed .
S&F 4.80mm thick tinted glass fixed to aluminium door /window /partitions etc of any size complete all as specified and directed.
S&F in repair 12mm thick prelaminated particle board,interior grade prelaminated both side with decorative choice lamination fixed with glazing clips rubber beading /gasket and aluminium beading for aluminium doors/partitions etc complete all as specified and directed.
S&F in repair double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed etc complete all as specified and directed.
S&F in repair aluminum alloy door closer hydraulically regulated, designation No 2 universal type, suitable for door shutters of 701 to 850mm in width and weight between 36 to 60 Kg and fixed to door frame complete all as specified and directed.
S&F in repair 65 mm size brass Dead lock two levers with duplicate key for aluminium door complete all as specified and directed.
S&F in repair 100mm size brass mortice lock four levers with both side brass handles & duplicate key for doors etc complete all as specified and directed.
S&F Anodised aluminium grills anodised transparent or dyed to required shade according to IS:1868 with minimum coating of grade AC 15 of approved design and pattern with approved standard sections and fixed to windows/ventilators frame with CP brass/stainless steel screws @ 200mm c/c including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS Square tube, fixed in opening as per specification & drawing shown in SSR Part I etc complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail & bottom rail on either side &as gap insert for top rail & bottom rail paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed togathers with solvent cement fixed to the frame at site as per specification & drawing shown in SSR Part I etc complete all as specified and directed
M&L for Pressed steel frames of size 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and directed.
M&L PCC 1:3:6 type C-1 (20 mm graded stone aggregate) as in filling pressed steel frame /hold fast blocks etc complete all as specified and directed.
M&L for 40 mm thick flush shutters ,solid core construction with block board core and plywood face panel complete all as specified and directed.
M&L for preparation of new wooden surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F mild steel butt hinges 100 mm long medium weight, cold rolled complete all as specified and directed.
S&F aluminium anodised extruded fabricated type handle 150mm long complete all as specified and directed.
S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) 250 mm long and fixing with bolts extruded sections etc complete all as specified and directed.
Supply and fixed 200 mm long Aluminium anodised barrel tower bolts of extruded section and fixed etc complete all as specified and directed.
Dismantling plain,corrugated steel/PVC/fiber glass sheeting any thickness and any size complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws bituminous washers etc complete all as specified and directed.
S&F 2 mm thick Fiber glass reinforced translucent corrugated sheeting with two corrugation side lap fixed coach /self drilled screws in roof ,walls etc complete all as specified and directed.
S&F in repair 12mm thick plain toughened glass door with all fittings as mentioned below including necessary cutting making holes (including taking down old glass doors) comprising of following complete all as specified and directed:- (a) Floor hydraulic machine 01 No in each shutters. (b) Stainless Steel handle of size 450 mm 25 mm dia - 02 Nos (Both side in each shutters. (c) Stainless Steel over panel set/connecting patch with pivot on corners. (d) Stainless Steel 'L' Connector for wall to wall and wall to glass - 4 Nos in each shutter. (e) Stainless Steel Centre lock 01 No in each shutter.
S&F in repair 0.15 mm thick PVC film (strip type plain and transparent) pasted on glasses with required adhesive complete all as specified and directed.
S&F in repair wooden flooring of 8mm thick size 1216x192mm with interlocking pannels with plastic and silicate mixture as the core material and surface with PVC foil on the top of concrete floor with glossy finish with matching colour teak wood/PVC beads and mouldings as per manufacturer instruction including taking out old wooden flooring complete all as specified and directed :
S&F in repair roller blinds consisting of aluminium head rail, of approved tint and traverse cord complete fixed in position complete all as specified and directed.
S&F in repair vertical venetian blinds consisting of aluminium head rail vanes/ louvers of 100 mm wide of approved tint and traverse cord fixed in position complete all as specified and directed.
M&L for providing and fixing stainless steel (grade 304) railing minimum gauge 14, made of hollow tubes,channels,plates ,bulbs etc including welding,grinding,buffing,polishing and making curvature(wherever required)and fitting the same with necessary stainless steel nuts and bolts complete including fixing the railing with necessary steel dash fastners,of required size on the top of floor or the side of waist slabs with suitable arrangments including taking out old railings complete all as specified and directed.
Dismantling structural steel /Mild steel work including doors, gates complete all as specified and directed.
S&F in repair Collapsible steel gates, top hung, consisting for channel pickets, pivoted flat bars, top and bottom runners, MS handles etc., as specified, erected in position and securing runners with holdfasts and brackets complete all as specified and directed
M&L for preparation of new steel or iron surface and applying two coats of synthetic enamal paint over a coat of red oxide primer complete all as specified and directed.
M&L for 10 mm thick screed bed or bedding layer in cement mortar 1:4, mixed with water proofing compound @ 3% by weight of cement complete all as specified and directed. Note : WPC shall be measured and paid separately.
M&L for Water proofing treatment over roof at any height consisting evenly applied bitumen primer coat @ 0.30 litre/ Sqm on surfaces, Applying evenly a tack coat of bitumen 85/25 grade @1.20 Kg /Sqm and a layer of APP polymer 3 mm thick membrane weight not less than 3.00 Kg/ Sqm duly sealed at over laps joints with flame (complete by torch application) again applying a coat of bitumen @1.20 Kg /Sqm on the top of APP all as per manufacturer's instructions, including taking out old roof treatments and testing on completion of WPT complete all as specified and directed. Notes:- (i) Application of polymeric membrane shall be by torch application. (ii) The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (iii) Primer shall be applied after preparing & cleaning of fully dried cement plastered surface.
Supplying only integral water proofing compound complete all as specified and directed.
M&L for repairs to MS rolling shutters, of size exc. 10 sqm with ball bearing, manual type operated, easening with welding if required, replacing defective or unserviceable parts as necessary to make it fully functional including taking down and refixing in same opening and painting with two coats of synthetic enamel paint all over complete all as specified and directed. Note :- Defective parts to be replaced shall be measured and paid separately under respective item of BOQ as supply only.
Supply only for mild steel spring for rolling shutters exc 10 Sqm including dismantling old unserviceable complete all as specified and directed.
Supply only for mild steel anchor rod for rolling shutters exc 10 Sqm including dismantling old unserviceable complete all as specified and directed.
Supply only mild steel ball bearing for rolling shutter exc 10 Sqm including dismantling old unserviceable complete all as specified and directed.
Supply only mild steel gear box and crank handle for rolling shutters exc 10 Sqm including dismantling old unserviceable complete all as specified and directed.
Providing and ejecting chemical emulsion at points of contact of wooden work by chemical emulsion(in oil/kerosene based solution)@ 0.50 Ltr/hole by drilling 6 mm dia holes at downword angle of 45 degree at 150 mm centre to centre and sealing the same complete all as specified and directed.
M&L treating the top surfaces of false ceilings,wall portion above false ceiling and any effected area of wood or masonry works with chemical emulsion of anti termite treatments at the rate of 01 Ltr per Sqm of surface area by pouring or spraying complete all as specified and directed.
S&F in repair steel rolling shutters of thickness of lath 1.00 mm without ball bearing as specified including top cover,anchoring rod,hasp and staple and one shop coat oof primer ,errected in position complete gear oprated type with bevel gear box and crank handle including taking down old rolling shutters complete all as specified and directed.
S&F in repair Safety lever lock mild steel with 4 lever for rolling shutters complete all as specified and directed.
S&F in repairs Ball bearing for rolling shutters complete all as specified and directed.
Demolition of brick work or stone/ boulder masonary built in cement mortar including all quoins arches, pillers etc but excluding ashler facings dressed stone work and precast concrete articles complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius in cement mortar (1:6) complete all as specified and directed.
All as per item ser No 61 but except bricks. Note:- old serviceable bricks retrieved from item No 60 shall be resued.
Taking down cement plaster on brick or stone walls including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick plastering in CM 1:4, finished even & smooth without using extra cement complete all as specified and directed.
M&L for Rough cast plaster including 15mm thick rendering in CM 1:3 on brick work or concrete surfaces complete as specifed in SSR Part-I clause 14.22 complete all as specified and directed. Note :- Rough cast finish to be as below :- After applying the under coat of cement mortar 1:3 and while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel aggregate (which is generally of size between 6 to 12 mm depending on the texture required) mixed with coarse sand and cement in the ratio of 1:1:1 shall be applied and finished even. The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure that larger aggregate are thoroughly covered.
M&L for preparation of new plastered surface of walls and applying two coat of cement base paint of any shade over a coat of alkali resistant primer complete all as specified and directed.
M&L for PCC type B-1, 1:2:4 (using 20mm graded stone aggregate) as in coping,bed plate including water trough and the like weathring, slightly rounded or chamferred angles and throating including formwork complete all as specified and directed.
Demolition of cement concrete in ground floor and pavings n,exc 15 Cm thick (below or above ground level) complete all as specified and directed.
M&L for PCC type B-1, 1:2:4 (using 20mm graded stone aggregate) as in surface channel & drain complete complete all as specified and directed.
M&L for PCC 75mm thick 1:3:6, type C2 (using 40 mm graded stone aggregate) as in sub base of floor complete all as specified and directed
M&L for Prepainted coloured Chequered cement concrete tiles 30cmx30cmx25mm thick, set, jointed and pointed in neat cement slurry in floors laid over and including 20mm thick screed bed in CM 1:6 complete all as specified and directed.
S&F in repair 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc including taking out old barbed wire complete all as specified and directed. Note : each line wire to be measured
S&F in repair for concertina coil reinforced punched (chrome razor of blade wire) with barbed tap of 0.5mm thick galvanized steel sheet and core wire of dia 2.5mm high tensile steel wire of concertina coil fencing with punched tape, 730mm dia, having 45 Nos rounds per 6m length, including taking out old wire complete all as specified and directed. Note : liner horizontal length to be measured.
Demolition of reinforced cement concrete as in drains or manhole covers of any description and in any position not otherwise specifically provided for complete all as specified and directed.
S&F Factory made precast Heavy duty drain/manhole covers with MS frame and reinforced, conforming to IS: 12592-2002 complete all as specified and directed .
S&F mild steel angles or tees etc as in posts and struts in fencing including embeding in concrete and screwing etc. including cut to shape as directed, drilling holes, notching for wire etc including all necessary drilling, bolting, welding or riveting and similar work conforming to FE-290 Gde E-165 complete all as specified and directed.
S&F Mild Steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; wall ways; railings; framework of water tanks and similar work con-forming to Fe.290. Gde-E-165 complete all as specified and directed.
M&L for Providing and laying at or near ground floor factory made kerb stone of M-25 grade cement concrete in position to the required line,level and curvature,jointed with cement mortar 1:3 including making joints with or without grooves(thickness of joints except at sharpe curve shall not to more than 5 mm)including making drainage ,opening wherever required including taking out old Kerb stone and removing from MOD land complete all as specified and directed.
M&L preparation of new concrete surfaces of any description over 10 cm width or girth and applying two coats of synthetic enemel paint over a coat of priming paint complete all as specified and directed.
M&L for providing and laying 60 mm thick factory made chemfered edges cement concrete paver block of M-35 grade with approved colour,design and pattern as in footpath,park,lawns or light traffic parking etc of required strength,thickness,size,shape made by table vibrating method using PU mould laid in required colour and pattern over and including 50 mm thick compacted bed of fine sand,commpacting and proper embedding/laying of interlocking paver block in sand bedding layer through vibrating compaction by using plate vibrator,filling the joints with fine sand and cutting of paver block as per required size and pattern,finishing and sweeping extra sand complete all as specified and directed.
S&F welded steel wire fabric fixed to steel or wooden members weight n,exc 4 Kg per Sqm complete all as specified and directed.
M&L 20 mm thick heavy duty ultra paver coloured tiles of any pattern and size as in floor laid over and including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
Removing excavated material/Malba to a distance exceeding 1.5 KM and not exceeding 5 KM depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed.
Preparation of new ceiling surface and applying two coats of oil bound distemper complete all as specified and directed.
Taking up or down steel tubing and connection 25 mm bore complete all as specified and directed.
Taking up or down steel tubing and connection 40 mm bore complete all as specified and directed.
S&F in repair 25 mm bore galvanised tubes medium grade with all fittings fixed to walls, ceiling or laid in floors complete all as specified and directed.
S&F in repair 40 mm bore galvanised tubes medium grade with all fittings fixed to walls, ceiling or laid in floors including taking down old unserviceable pipes complete all as specified and directed.
S&F in repair 25 mm bore Gun metal, globe or gate valves with iron wheal head, screwed both ends for iron pipes and fixed complete all as specified and directed.
S&F in repair 40 mm bore Gun metal, globe or gate valves with iron wheal head, screwed both ends for iron pipes and fixed complete all as specified and directed.
M&L in repair green marble work 16-18 mm thick (table rubbed and polished) as in steps, floors/pillars, cills, jambs and like over and including CM 1:4 with admixture of pigments to match the marble shade including border of different colour of marbles if required laid over 15 mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed.
SAWARIYA ENGINEERS AND CONTRACTORS
V.V CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .