Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.3 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹31.5 L+₹1.9 L (6.43%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹35.5 L+₹5.8 L (19.7%)Rejected-Finance WZ 1000 B NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹36.7 L+₹7.0 L (23.7%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹38.5 L+₹8.8 L (29.8%)Rejected-Finance | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹45.0 L
EMD Value
₹90,000
Closing Date
12 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
arjun patro,idse
ge u electric supply ,delhi cantt
Manning and operation of MH line Sub Stn and ME line Sub Stn Repair and replacement of LT distribution Panels and feeder pillars with connected works at the area of MH line MD accn ME line MD accn 505 JCOs MD accn and associated area of AGE U ES No
2021_MES_452320_1
GE ELECT/D-35/2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
ge u electric supply
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹90,000
Yes
14 Sept 2021
19 Jun 2021
14 Jul 2021
20 Jun 2021
12 Jul 2021
6 Jul 2021
60 days
Amount
Maintanance services to be provided for 11 KV / 415 Volt MH line Sub Stn, HQ DGBR, NSB-II Naraina, Naraina Pump house and AF Naraina as per details as under:- (a) The installation is main receiving station and complaint centre minimum 01 electrician per shift shall be provided round the clock .The electrician shall have adequate knowledge of above maintioned job and GE/Engr-in-charge can reject the proposed electrician giving reasoned rejection.No claim shall be admissible on account of rejection of person. (b) Details of equipment:-Transformer step down 11 KV/433 Volts capacity 500 KVA - 01 Nos, 400 KVA - 01 No, 315 KVA -01 NO, 250 KVA - 01 No, 200 KVA - 02 Nos & 100 KVA - 01 No. 11 KV VCB/RMU as outgoing including control panel - 20 Nos, LT panel -04 Nos, Feeder pillars - 07Nos Note :- applicable for item No 01 & 02 (c) The followingchecking/testing,supervision shall be carried out by electrician in respect of equpments mentioned at at para (b) above:- (i) Recording of all parameters of system as per indication of all equipments installed in the log sheets directed by Engr-in-Charge round the clock on daily basis. (ii) Maintainance of fault register (iii) Maintainance of shutdown register (iv) Proper operatiion of 11 KV Breaker (v) Giving of Shutdown by draw out of trolley of breaker (vii) Checking of status of LED indication for breaker on , off , trip , spring charge , trip circuit healthy on daily basis. (viii) Checking of status of annunciator, hooter , indicators , meters, TNC switch , emergency trip push button , MCB for AC DC isolation, heater , thermostate on daily basis ((x) Cheking of Oil temprature of transformer oil as directed by Engr-in-charge. (xi) Checking of winding temprature of transformer as directed by Engr-in-Charge. (xii) Checking of oil level of transformer as directed by Engr-in-Charge. (xiii) Checking the batteries in serviceable and charged condition by checking battery, leads, battery lugs on daily basis. (xiv) Attending of all complaint of the SUb Stn. (xv) Cleaning of dust & foreign particles on and around the panel (xvi) Checking of condition of leakage of oil from transformer tank, bushing, radiators and other parts on weekly basis (xvi) Checking condition of silica gel on weekly basis (xvii) Testing BDV of transformer oil as directed by Engr-in -Charge. (xviii) Testing of earth resistance of all earthing as directed by Engr-in-charge. (xix) Checking of DC voltage of system as directed by Engr -in-charge (xvi) Checking of condition of leakage of oil from transformer tank, bushing, radiators and other parts on weekly basis (xvi) Checking condition of silica gel on weekly basis (xvii) Testing BDV of transformer oil as directed by Engr-in -Charge. (xviii) Testing of earth resistance of all earthing as directed by Engr-in-charge. (xix) Checking of DC voltage of system as directed by Engr -in-charge
Note : (i) The contracotor will ensure suitable repalcement of electrician while on leave/weekly holidays and Wages for the same deemed to be included in the quoted rate. (ii ) The contractor shall ensure that electricians/ operator always be present in each shift. In case of absence of any worker the penalty @ Rs 100.00 per hours per electricians/ operator shall be imposed on the contractor. (iii) The contractor shall be responsible for maintaining the complete area (i.e. inside boundary wall ) such as building , hard standing , foothpath etc in neat and clean position . All necessary T&P for cutting /cleaning of grass and vegitation will be arranged by contractor without any extra cost. (iv) The contractor shall provide uniform , raincoat, protective clothing such as hand gloves ,helmet, safety belt , first aid box and shoes etc to all persons on duty and the cost of the same is deemed to be included in quoted rate. (v) Person employed should be working experience of working on HT and LT Installation. (vi) The contractor shall provide log sheet and maintain the the same on daily basis and the cost of the same is deemed to be included in quoted rate.
Worker's wage per person per day per shift (inclusive of GST as applicable)
Employees Provident Fund as per existing rules (Prescribed Rate of EPF as applicable on (minimum wages without GST ) + GST Rate as applicable on Prescribed Rate of EPF as applicable on (minimum wages without GST )
Employees state insurance as per existing rules. (Prescribed Rate of ESI as applicable on (minimum wages without GST) + GST Rate as applicable on Prescribed Rate of ESI as applicable on (minimum wages without GST )
Contribution of Bonus as per existing rules. (Prescribed Rate of BONUS as applicable on (minimum wages without GST) + GST Rate as applicable on Prescribed Rate of BONUS as applicable on (minimum wages without GST)
Over head & profit on total of srl No 1.02 to 1.05 as applicable.
LWC as per existing rules on total of srl no 1.02 to 1.06. The bidder should note that the minmum wages including all statutory provisions as mentioned in item no 1.02 to 1.06 are exclusive of GST for calculating of labour cess. Refer Sch 'A'Note No 33 (e) on Page No 19 of Tender Document.
NOTE For Item 1 and sub items :- (a) The quoted rate against EPF, ESIC and Bonus shall be considered for payment on actual basis. Contribution towards EPF, ESIC and Bonus is payable only after submission of valid and authentic document in support of having paid the requisite amount of bonus to the workmen, ie proof of payment. (b)The rate quoted shall not be less than minimum wages as notified by Government of India / State Government / Local body whichever is higher including all statutory provisions such as EPF,ESIC,Bonus,taxes etc as applicable and also not less than applicable rates for contribution of employer towards EPF,ESIC and BONUS under respective heading /subitems. In case the rates quoted are less than the minimum wages as notified by the Government of India / State Government / Local body whichever is higher including all statutory provisions such as EPF,ESIC,Bonus,taxes etc on the last due date of bid submission. his tender will be treated as non bonafide and will not be considered for acceptance.In such case,the lowest bidder shall be determined from amongst the valid/bonafide bids only. (c) 'NIL' or 'Zero' quoting against OH & Profit will be treated as 'Non-bonafide'.'.
d) Contractor is required to quote upto two digits after decimal place or otherwise it will be considered by rounding off to two digits after decimal place in accordance with Rules for Rounding off of Numerical Values in accordance with IS:02 OF 1960(Revised 2016) of BIS. (e) In case of any variation occurs in minimum wage, liability of EPF/ESIC/Bonus/LWC/GST during contract period /extended contract period that shall be adjusted for reimbursement/recovery as under:- (i) Variation in minimum wage including other related statutory provisions shall be adjusted in terms of Condition 63 of GCC (IAFW-2249). (ii)Variation in percentage/rate of GST and LWC shall be adjusted as per instructions in Annexure XVI of MES Manual on Contracts which deals with ‘Reimbursement/Refund on Variation in Taxes Directly Related to Contract Value’’
Maintanance services to be provided for 11 KV / 433 Volt ME line Sub Stn, 505 unit line & AOC Sub Stn as per details as under:- (a) The installation is main receiving station and complaint centre minimum 01 electrician per shift shall be provided .Total Two shifts per day .The electrician shall have adequate knowledge of above maintioned job and GE/Engr-in-charge can reject the proposed electrician giving reasoned rejection.No claim shall be admissible on account of rejection of person. (b) Details of equipment:-Transformer step down 11 KV capacity 630 KVA - 02 Nos, 250 KVA - 01 No & 500 KVA - 01 Nos 11 KV VCB IN / Outgoing -13 Nos, LT panel -05 Nos, Feeder pillars - 31 Nos, RMU 05 Way, (c) The followingchecking/testing,supervision shall be carried out by electrician in respect of equpments mentioned at at para (b) above:- (i) Recording of all parameters of system as per indication of all equipments installed in the log sheets directed by Engr-in-Charge round the clock on daily basis. (ii) Maintainance of fault register (iii) Maintainance of shutdown register (iv) Proper operatiion of 11 KV Breaker (v) Giving of Shutdown by draw out of trolley of breaker (vii) Checking of status of LED indication for breaker on , off , trip , spring charge , trip circuit healthy on daily basis. (viii) Checking of status of annunciator, hooter , indicators , meters, TNC switch , emergency trip push button , MCB for AC DC isolation, heater , thermostate on daily basis. (x) Cheking of Oil temprature of transformer oil as directed by Engr-in-charge. (xi) Checking of winding temprature of transformer as directed by Engr-in-Charge. (xii) Checking of oil level of transformer as directed by Engr-in-Charge. (xiii) Checking the batteries in serviceable and charged condition by checking battery, leads, battery lugs on daily basis. (xiv) Attending of all complaint of the SUb Stn. (xv) Cleaning of dust & foreign particles on and around the panel (xvi) Checking of condition of leakage of oil from transformer tank, bushing, radiators and other parts on weekly basis (xvi) Checking condition of silica gel on weekly basis (xvii) Testing BDV of transformer oil as directed by Engr-in -Charge. (xviii) Testing of earth resistance of all earthing as directed by Engr-in-charge. (xix) Checking of DC voltage of system as directed by Engr -in-charge
Note : (i) The contracotor will ensure suitable repalcement of electrician while on leave/weekly holidays and Wages for the same deemed to be included in the quoted rate. (ii ) The contractor shall ensure that electricians/ operator always be present in each shift. In case of absence of any worker the penalty @ Rs 100.00 per hours per electricians/ operator shall be imposed on the contractor. (iii) The contractor shall be responsible for maintaining the complete area (i.e. inside boundary wall ) such as building , hard standing , foothpath etc in neat and clean position . All necessary T&P for cutting /cleaning of grass and vegitation will be arranged by contractor without any extra cost. (iv) The contractor shall provide uniform , raincoat, protective clothing such as hand gloves ,helmet, safety belt , first aid box and shoes etc to all persons on duty and the cost of the same is deemed to be included in quoted rate. (v) Person employed should be working experience of working on HT and LT Installation. (vi) The contractor shall provide log sheet and maintain the the same on daily basis and the cost of the same is deemed to be included in quoted rate.
Worker's wage per person per day per shift (inclusive of GST as applicable)
Employees Provident Fund as per existing rules (Prescribed Rate of EPF as applicable on (minimum wages without GST ) + GST Rate as applicable on Prescribed Rate of EPF as applicable on (minimum wages without GST )
Employees state insurance as per existing rules. (Prescribed Rate of ESI as applicable on (minimum wages without GST) + GST Rate as applicable on Prescribed Rate of ESI as applicable on (minimum wages without GST )
Contribution of Bonus as per existing rules. (Prescribed Rate of BONUS as applicable on (minimum wages without GST) + GST Rate as applicable on Prescribed Rate of BONUS as applicable on (minimum wages without GST)
Over head & profit on total of srl No 2.02 to 2.05 as applicable.
LWC as per existing rules on total of srl no 2.02 to 2.06. The bidder should note that the minmum wages including all statutory provisions as mentioned in item no 2.02 to 2.06 are exclusive of GST for calculating of labour cess. Refer Sch 'A'Note No 33 (e) on Page No 19 of Tender Document.
NOTE For Item 2 and sub items :- (a) The quoted rate against EPF, ESIC and Bonus shall be considered for payment on actual basis. Contribution towards EPF, ESIC and Bonus is payable only after submission of valid and authentic document in support of having paid the requisite amount of bonus to the workmen, ie proof of payment. (b)The rate quoted shall not be less than minimum wages as notified by Government of India / State Government / Local body whichever is higher including all statutory provisions such as EPF,ESIC,Bonus,taxes etc as applicable and also not less than applicable rates for contribution of employer towards EPF,ESIC and BONUS under respective heading /subitems. In case the rates quoted are less than the minimum wages as notified by the Government of India / State Government / Local body whichever is higher including all statutory provisions such as EPF,ESIC,Bonus,taxes etc on the last due date of bid submission. his tender will be treated as non bonafide and will not be considered for acceptance.In such case,the lowest bidder shall be determined from amongst the valid/bonafide bids only. (c) 'NIL' or 'Zero' quoting against OH & Profit will be treated as 'Non-bonafide'.'.
d) Contractor is required to quote upto two digits after decimal place or otherwise it will be considered by rounding off to two digits after decimal place in accordance with Rules for Rounding off of Numerical Values in accordance with IS:02 OF 1960(Revised 2016) of BIS. (e) In case of any variation occurs in minimum wage, liability of EPF/ESIC/Bonus/LWC/GST during contract period /extended contract period that shall be adjusted for reimbursement/recovery as under:- (i) Variation in minimum wage including other related statutory provisions shall be adjusted in terms of Condition 63 of GCC (IAFW-2249). (ii)Variation in percentage/rate of GST and LWC shall be adjusted as per instructions in Annexure XVI of MES Manual on Contracts which deals with ‘Reimbursement/Refund on Variation in Taxes Directly Related to Contract Value’’
Earthing in replacement complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
Taking out underground 1100 Volt LT cable in loop of different sizes by excavation and removing bricks of any size and relaying in the same trenches after fixing of new panel and removing of surplus soil and using new bricks as required. Note: (a) Retrieved old serviceable bricks will be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (b) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified.
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
All as per srl item No 17 here-in-before but using old bricks obtained under srl item No 13 here in before.
Supply & Fixing in replacement bracket for street light fitting complete with 1.5 to 2.2 mtr long 32/40mm dia GI pipe medium grade and including necessary mild steel clamp , nuts,bolts and wahsers and painting on steel surfaces with two coats of aluminium paint complete as as specified and directed.
S&F in replacement KIOSK box wheather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4 strips for 3 phase and neutral 63 Amps including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and directed.Incluiding MS clamp of size 25x3 mm with suitable size nut,bolts & washer.
Supply drawing, connecting and testing in replacement 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed copper conductor (flexible ) industurial cable, 1100 Volts conforming to IS 694 in steel tubular poles from KIOSK box to street light fitting including providing suitable copper lugs all as specified and directed by Engr-in-charge.
Taking down existing worn out/old/broken ACSR conductors of any size and length at any position from existing LT street light poles complete all as specified and directed by Engr in charge.
Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable of size 16 Sqmm 4 core (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed . Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule.
S&F in replacement GI Pipe of size 40 mm dia (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah complete all as specified and directed .
M&L in replacement of Antistatic flooring of thickness 2.5mm thick of standard width and roll length conferming to 5TEC-7 pamplet Electrostatic decreease less than 0.5 sec and fixing with adhesive SR 998 Comp strip of grid 1m x 1 m size 01 inch x 50 microne complete all as specified and directed.thickness.
Note : (i)contractor should provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge.
Rajindera Enterprises
mayur enterprises
Vijay Electricals
Buddham Builders
V r traders
M/S ASHISH AND CO
Ridhi engineers and builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .