| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L1 | Accepted-AOC Being overall reasonable | |
| 2 | L2₹38.8 L+₹1.3 L (3.43%)Rejected-Finance FLAT NO 401 TULSANI HEIGHTS 4TH FLOOR GREEN PARK SOCIETY AKURDI GURUDWARA TO WALHEKAR WADI ROAD CHINCHWAD PUNE 411033 | PUNE | MAHARASHTRA | 411033 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹39.5 L+₹2.0 L (5.46%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹40.5 L+₹3.0 L (8.13%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹43.9 L+₹6.4 L (17.1%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
20 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE-411003
REPAIRS AND MAINTENANCE OF WALL MOUNTED LT DBs OVER HEAD TRUNKING BUS BAR AND CONNECTED WORKS AT VARIOUS BUILDINGS OF 512 ABW UNDER AGE EM II IN GE CENTRAL KIRKEE
2022_MES_547301_1
8686/E8 OF 2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
512 ABW area
Class D Category b(i)
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹98,000
Yes
10 Oct 2022
24 Aug 2022
22 Sept 2022
24 Aug 2022
20 Sept 2022
8 Sept 2022
24 Aug 2022 - 7 Sept 2022
Amount
Dismantling of MS top covers of exisiting trunking bus bars (at a height of appx. 30 feet above GL ), scrapping the inside of the busbar chamber to remove all dust particles and rusted iron particles, etc., vaccuming out all the dust particles inside the busbar chamber using a suitable vaccum cleaner and tightening of inter connections between copper bus bars within the trunking busbar complete,including refixing the covers and testing of the same after completion of the job for the full satisfaction of Engineer in charge complete all as specified and as directed.
Dismantling of over head trunking bus bar of any capacity/rating including all connected outgoing cables and plug in boxes at a height of upto 10 mtr GL complete all as specified and as directed.
Supply Installation,testing and commisioning of 250 Amps aluminium sandwitch type 3P4W 100%N and 50% internal earth busbar other than housing, operating voltage 415V, Insulation Voltage 1.1kV Rated Short time Current 18kA for 1Sec IP54, Mechanical Strength IK10 protection. bus duct should be Seismic zone -5 certified. The bus duct shall be type tested at a reputed test laboratory (certified by CPRI / ASTA / ERDA or any NABL accrediated lab) for the tests as per IEC-61439 Part-1 (Low voltage switchgear & controlgear assembly- General rules) & Part 6 (Bus bar trunking systems & bus ways); The rated current of busbar trunking systems is always rated at the average ambient temperature of 40°C (70x135 mm, enclosure thickness 1.6 mm GI) Insulation material used shall be of class F (155 degree) UL certified, ROHS Compliant, the conductors are made from an aluminum & tin plated at joints. provided with a monobloc pre-installed at the factory at one end. Contd...04
Contd,, from 03 It should ensure the IP 54 degree of protection at the end of the run, all insulating plastic components comply with the incandescent wire test and have the standard degree of protection of IP 54 without using additional IP protection kits, the whole busbar is resistant to flame propagation and building penteration as pe IEC in compliance with standard 61439-6. Make L&T / Legrand complete all as specified and as directed. NOTE :- (i) Cost of any material and labour required for fixing of new bus bar in homogeneous with the existing old trunking bus bar is deemed to be included in the quoted rate. (ii) Fabrication of plug point on bus bar as per directed by engineer in charge.
Supply, installation, testing and commisioning of 400 Amps aluminium sandwich type construction 3P4W 100%N body enclosure as integral earth operating voltage 1000 V suitable for 50 / 60 Hz with impulse withstand voltage of 12kV, insulation voltage 1000V rated, short time current 36kA for 1 sec,.overall dimension of 130x130mm, aluminium conductor with CU coating on entire surface, insulated with red class F thermosetting plastic material and factory fitted in one side of the each trunking components, the enclosure shall provide a protection not less than IP- 55 as per IEC-60529 for indoor application, the busbar trunking shall comply with standard IEC 61439-6 and the rated current of the busbar trunking systems shall be referred to the average ambient temperature of 40 °C, the bus duct enclosure consists of four C-ribbed section bars, bordered and riveted, with excellent mechanical, electric and heat loss efficiency, the sheet metal is made of 1.5 mm thick hot-galvanized steel, treated according to UNI EN 10327 and painted with RAL7035 resins with high resistance to chemical agents, Contd...06
Contd,, from 05 The enclosure shall provide a protection of IK 10 against mechanical impact, the enclosure paint shall have maximum resistance to corrosion with salt spray life of 1500hrs.tapoff box with mechanical interlocking feature for MCCB Power Isolation complete all as specified and as directed. Make:- L&T / Legrand /ABB. NOTE for Sl Item 03 & 4 :- (i) Cost of any material and labour required for fixing of new bus bar in homogeneous with the existing old trunking bus bar is deemed to be included in the quoted rate. (ii) Cost of fabrication of plug point on bus bar is included in quoted rate. (iii) Fabrication of plug point on bus bar as directed by Engineer in charge. (iv) All safty measures shall be adoted as per manufactureres direction during execution . (v) Any thing missed out above but technically required for proper operation of the system is deemed to be included in the quoted rate.
Labour only for fabrication of flange end on bus bar as per directionof Engineer in charge.
Supply and fix end feed unit with swithgear of 250 Amps MCCB 4P, 25kA suitable for sand witch type bus bar trunking system with complete all as directed by Engr-In-Charge.
Supply and fix end feed unit with swithgear of 400 A MCCB 4P 36kA suitable for sand witch type bus bar trunking system with complete accessoriesall as directed by Engr-In-Charge.
Supply and fix reducer for 400 Amps to 250 Amps suitable for sandwitch bus bar trunking system (of any rating) complete all as sapecified and as directed.
Supply and fix end cover suitable for sandwitch type trunking bus bar system (of any rating) complete.
Dismantling of old plug in box, supply and fix rust proof steel sheet plug in box with hinged door housing four pole 32 Amp MCB "C" curve 10 KA rating solidly connected to high conductivity copper pin with provision of gland plates for cable entry having fully insulated plug in points which should be easily plugged in live bus bars of 32 Amps rating all as per direction of Engr-In-Charge.
Dismantling of old plugin box, supply and fix rust proof steel sheet plug in box with hinged doors housing four pole 40 Amp MCB "C" curve 10 KA rating solidly connected to high conductivity copper pin with provision of gland plates for cable entry having fully insulated plug in points which should be easily plugged in live bus bars of 40 Amps rating all as per direction by Engr-In-Charge.
Dismantling of old plug in box, supply, fix, test and commissioning rust proof steel sheet plug in box with side hinged doors housing 63 Amps, TPN, MCCB 25 kA, solidly connected to high conductivity tin plated copper insulated pin-on contacts with provision of gland plates for cable entry, having fully insulated plug in points which should be easily plugged in bus bars of 63 Amps rating complete all as specified and as directred.
Dismantling of old plugin box, supply, fix, test and commissioning rust proof steel sheet plug in box with side hinged doors housing 125 Amps TPN MCCB 25kA, solidly connected to high conductivity tin plated copper insulated pin-on contacts with provision of gland plates for cable entry, having fully insulated plugin points which should be easily plugged in bus bars of 125 Amps rating complete all as specified and as directred.
Dismantling of old plugin box, supply, fix, test and commissioning rust proof steel sheet plug in box with side hinged doors housing 300 Amps TPN MCCB 36kA, solidly connected to high conductivity tin plated copper insulated pin-on contacts with provision of gland plates for cable entry, having fully insulated plugin points which should be easily plugged in sandwitch type bus bars system complete all as specified and as directred.
Dismantling of old plugin box, supply, fix, test and commissioning rust proof steel sheet plug in box with side hinged doors housing 400 Amps TPN MCCB 36 kA, solidly connected to high conductivity tin plated copper insulated pin-on contacts with provision of gland plates for cable entry, having fully insulated plugin points which should be easily plugged in sandwitch type bus bars system complete all as specified and as directred.
Material and labour for cross arms, bracings, supports, clamps and back plates fabricated from rolled structural steel sections including nuts, bolts, washers, welding, bending colt or hot, drilling holes for bolts, at any height, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint for mounting of bus bar trunking including fixing arrangements complete all as specified and as directed.
Removing of old main switch after disconecting the incoming and out going cables and supply and fix MCCB thermal magnetic release four pole 25 KA 63 Amps Make Legrand Cat No 420053 /L&T /ABB with one way metal inclosure Cat No 5078 01 /L&T /ABB and making conections of cables with suitable size nutbolt etc including making good the disturbed suface of wall including material complate all as specified and as directed.
Removing of old main switch after disconecting the incoming and out going cables and supply and fix MCCB thermal magnetic release four pole 25 KA 100 Amps Make Legrand Cat No 420055 /L&T /ABB with one way metal inclosure Cat No 5078 01 /L&T /ABB and making conections of cables with suitable size nutbolt etc including making good the disturbed suface of wall including material complate all as specified and as directed.
Removing of old main switch after disconecting the incoming and out going cables, supply and fix MCCB thermal magnetic release four pole 25 KA 160 Amps Make Legrand Cat No 420057 /L&T /ABB with one way metal inclosure Legrand Cat No 5078 01 /L&T /ABB and making conections of cables with suitable size nuts, bolt etc including making good the disturbed suface of wall complate all as specified and as directed.
Removing of old main switch after disconecting the incoming and out going cables, supply and fix Industrial plug and socket board TP 32 Amps including plug top and MCB "C" curve 10 KA 32 Amps Make Legrand Cat No 5078 18 and 4086 58 /L&T /ABB and making conections of cables with suitable size nuts, bolt etc including making good the disturbed suface of wall complete all as specified and as directed.
Removing of old main switch after disconecting the incoming and out going cables, supply and fix one way metal ednclosure all as per LegrandCat No 5077 93 /L&T/ABB and MCB "C" curve TPN 10 KA 32Amps Legrand Cat No 4086 80 /L&T/ABB and making conections of cables with suitable size nuts, bolt etc. including making good the disturbed suface of wall complate all as specified and as directed.
Supply, fixing, connecting and testing in replacement of industrial earth plug & socket with sheet metal enclosure of IP 44 protection rating, electric driven, single phase including MCB 'C' series SP 20 Amps and supplied with neutral link complete all as specified and as directed.
Supply, fixing, connecting and testing in replacement industrial earth Plug & socket with sheet metal enclosure of IP 44 protection rating, electric driven three phase including MCB 'C' series TP 20 Amps and supplied with neutral link complete all as specified and as directed.
Disconnecting and taking out burnt XLPE Aluminium conductor cable of any description and in any position from walls / steel structure / laid in floors any size any core complete all as specified & directed by Engineer-in-Charge.
Supply and laying in trenches / laid in floors /ducts / drawn through conduit XLPE insulated PVC bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of cross sectional area 3.5 core, 35 sq.mm all as specified and directed .
Supply and laying in trenches / laid in floors /ducts / drawn through conduit XLPE insulated PVC bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of cross sectional area 3.5 core, 70 sq.mm all as specified and directed .
Supply and laying in trenches / laid in floors /ducts / drawn through conduit XLPE insulated PVC bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of cross sectional area 3.5 core, 120 sq.mm all as specified and directed .
Supply and laying in trenches / laid in floors /ducts / drawn through conduit XLPE insulated PVC bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of cross sectional area 4 core, 25 sq.mm all as specified and directed .
Supply and laying in trenches / laid in floors /ducts / drawn through conduit XLPE insulated PVC bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of cross sectional area 4 core, 16 sq.mm all as specified and directed .
Supply and laying in trenches / laid in floors /ducts / drawn through conduit XLPE insulated PVC bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of cross sectional area 3.5 core, 95 sq.mm all as specified and directed .
Disconnecting and taking down old switch fuse type distribution box with MCB / fuse grip TPN / SPN DB 2 Way to 12 Way old type DB including taking out all cable connections of any description and in any position including Material and labour for making good the disturbed surface of walls, to match with the existing surfaces complete all as specified and as directed by Engineer in charge.
Supply and fix, connecting & testing of VTPN DB of 4 way suitable for MCCB up to 160 Amps as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated busbar, neutral bar, door earthing, corner safe. wire sets, neutral bar, earth bar & wire ties, all as specified and as directed of Make Legrand /Schneider- Acti-9/ L&T-Exora. NOTE :- MCCB , MCB will be measured and paid separately under relevant item of this schedule.
Supply and fix, thermal magnetic adjustable MCCB 160 Amps 4 pole with breaking capacity 25 KA & shall be Ics=Icu 100%, complete all as specified and directed. MAKE ;- Legrand-DPX3 / Schneider-NSX/L&T.
Supplying and fix MCB 6 to 32 Amps, single pole and neutral, "C" curve 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly including taking down existing complete all as specified and directed. MAKE :- Legrand/ABB/L&T/ Seimens.
Supplying and fix MCB 6 to 32 Amps, single pole, 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, complete including taking down existing all as specified and as directed. MAKE :- Legrand/ABB/L&T/ Seimens.
Supply and fix, connecting & testing SPN DBs of 8 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK 09 conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated busbar, neutral bar, door earthing, corner safe, wire sets, neutral bar, earth bar & wire ties, all as specified and as directed. MAKE :- Legrand/Schneider/L&T.
Supply and fix, connecting & testing SPN DBs of 12 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09 conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting, DB shall be with insulated busbar, shrouded neutral bar, door earthing, corner safe. wire sets, neutral bar, earth bar & wire ties, all as specified and as directed. MAKE :- Legrand/Schneider/L&T.
Taking down existing unserviceable aluminum / copper point wiring of any description and in any position including all fittings and making good the disturbed surface to match with the existing surfaces complete all as specified and as directed.
Material and labour for point wiring in PVC coduit of suitable size but not less than 20mm dia including all fittings such as elbow, bends, junction boxes, saddles, etc. on surface with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sq.mm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sq.mm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and including PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover for one light point or one fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wall all as specified and directed by Engineer in charge.
All as per Sl Item No. 41 above but point wiring for 5 pin socket outlet, 5 Amps on same board with other switches.
All as per Sl Item No. 41 above but point wiring for 5 pin socket outlet, 5 Amps on independent board.
All as per Sl Item No. 41 above but point wiring for one five pin socket outlet, 15 Amps & 5 Amps on independent board using 2.5 sq.mm two run and one run 2.5 sq.mm (nominal area) stranded copper conductor cable.
Material and labour for point wiring in casing and caping of suitable size but not less than 20mm including all fittings such as elbow, bends, junction boxes, saddles, etc. on surface with and including ISI marked two runs of PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) 1.5 sq.mm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sq.mm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and including PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover for one light point or one fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wall all as specified and as directed by Engineer in charge.
All as per Sl Item No. 45 above but one bell/buzzer point controlled by one push button on the same board with other switches or independent with cables1.5 sq.mm. size.
All as per Sl Item No. 45 above but point wiring for 5 pin socket outlet, 5 Amps on same board with other switches.
All as per Sl Item No. 45 above but point wiring for 5 pin socket outlet, 5 Amps on independent board.
All as per Sl item No 45 above but point wiring for one five pin socket outlet, 15 Amps & 5 Amps on independent board using 2.5 sq.mm two run and one run 2.5 sqmm (nominal area) stranded copper conductor cable.
Supply and fix switch flush type, 5 Amps, single pole, one way , 230 volts AC circuit complete all as specified and as directed
Supply and fix bell push, flush type, 5 Amps, flush type, 230 volts AC circuit complete all as specified and as directed.
Supply and fix socket outlet, five pin, 5 Amps, flush type, multipurpose, 230 volts AC circuit complete all as specified and as directed.
Supply and fix switch flush type, 15 Amps, single pole, one way , 230 volts AC circuit complete all as specified and as directed.
Supply and fix socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type, 230 volts AC circuit complete all as specified and as directed.
Supply and fix ceiling rose PVC/polycarbonate, isolated body, three terminals, complete all as specified and as directed.
Supply and fixing in replacement stepped type electronic fan regulator flush type suitable for ceiling fans, prewired 230 volts AC 50Hz supply 100Watt complete all as specified and as directed.
Dismantling and taking out old unserviceable copper/aluminium sub main wiring / unarmoured cable (used as sub main wiring) from any height or any size and Core with all connecting accessories including conduit or casing caping and making good to the disturbed wall and painting the same with matching paint as of existing wall all as specified and as directed by Engineer in charge.
Material and labour for sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type, 4.0 sq.mm, 1100 volts grade, drawn through and including new PVC rigid non metallic conduit 20 mm dia including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type, 4.0 sq.mm, 1100 Volts grade,,green in colour as earth contuinity wire all as specified and as directed by Engineer in charge.
Material and labour for sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type, 4.0 sq.mm, 1100 volts grade, drawn through and including casing caping including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type, 4.0 sq.mm, 1100 Volts grade,,green in colour as earth contuinity wire all as specified and directed by Engineer in charge.
Material and labour for sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type, 6.0 sq.mm, 1100 volts grade, drawn through and including casing caping including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type, 4.0 sq.mm, 1100 volts grade green in colour as earth contuinity wire all as specified and as directed by Engineer in charge.
Supplying, fixing and connecting up to existing/new ceiling rose and testing industrial box type batten with precoated CRCA body. LED tube light fitting suitable for and including 1x20 W 4 feet long tube with polycarbonate diffuser, LED lamp efficay -110 Lum/W ,THD ≤15% with operating voltage range 100-300 volts, driver efficiency >85%, surge voltage withstand 2.5 KV , power factor ≥0.9 including taking down existing and all accessories for fixing on steel trusses / false ceiling all as specified and as directed. MAKE :- Crompton Cat no-IGP161LT8-16 & LT8-20-865 or equivalent in Havells / Bajaj / Philips
Supplying, fixing and connecting up at any height up to existing/new ceiling rose and testing LED luminarie made up of precoated CRCA housing provided with cum reflector finished in white powder coating, completely prewired with accessories up to terminal block suiatble for 2x 20W 4 feet long LED tubes(High Lumen-110 Lumen/Watt) including taking down existing and fixing arrangements for fixing on steel trusses / false ceiling all as specified and as directed. MAKE :- Crompton Cat no-IGP162LT8-16 & LT8-20-865 or equivalent in Havells / Bajaj / Philips
Supplying, fixing and connecting up to existing/new ceiling rose and testing 36 Watt aesthetically designed 2' x 2' LED recess mounting in grid/armstrong type ceiling including suitable LED driver and connecting with copper conductor flexible twisted two core cable to existing/new ceiling rose and including taking down of old fitting complete all as specified and as directed. MAKE :- Crompton /Havells / Bajaj / Philips
Supplying, fixing and connecting in at any height up to existing/new ceiling rose and testing LED batten with 20 Watt LED light source in integral module with polycarbonate/Acrylic diffuser more than 85%efficiency of light with LED lamp efficay as 110 Lum/W THD ≤15% with operating voltage range 100-300V, driver efficency >85%, surge voltage withstand 2.5 KV , power factor ≥0.9, fittings conection complete including taking down existing all as specified and as directed. NOTE for Sl Item No. 59 to 62 :- Quoted rate is deemed to be inclusive of any miscelleneous materials required for fixing new luminaries and dismantling cost of old light fitings.
SHAILENDRA B TULSANI
ONKAR ELECTRIC AND GENERAL STORE
Veekay Enterprises
PAMS ENTERPRISES
metro electrical services
M/S. OM ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .