Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC FLAT NO 2450 KRISHNA COLONY JIND 126102 | JIND | HARYANA | 126102 | ₹1.7 Cr | L1 | Accepted-AOC Awarded |
| 2 | L2₹1.9 Cr+₹16.3 L (9.37%)Rejected-AOC HOUSE 630 VILLAGE PUR TEHSIL BAWANI KHERA DISTRICT BHIWANI 127032 | BAWANI KHERA | BHIWANI | HARYANA | 127032 | ₹1.9 Cr+₹16.3 L (9.37%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹2.1 Cr+₹33.5 L (19.3%)Rejected-AOC | ₹2.1 Cr+₹33.5 L (19.3%) | L3 | Rejected-AOC Rejected |
Tender Value
₹2.0 Cr
EMD Value
₹4.0 L
Closing Date
28 May 2021, 3:00 pmClosed
EE
Behind PWD Rest House Jawahar Nagar Camp Palwal, Distt. Palwal (Haryana)
Construction of Boosting Station consisting with U.G. Water Storage Tank, Boosting Chamber, Boosting Machinery, Laying of D.I. Rising Main Laying of Distribution System of DI pipe line Operation for 5 years including 1 year defect liability per
2021_HRY_170857_1
SE PWL No. 4513 dated 28/04/2021
Open Tender
Civil Works
Works
300 days
Palwal
Refer to Tender Documents
3 documents required · 3 mandatory
₹15,000
Yes
₹4.0 L
Yes
2 Jul 2021
6 May 2021
28 May 2021
6 May 2021
28 May 2021
6 May 2021
Amount
Garhi Patti Supplying & erection of horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No.II complete in all respect with complete base frame. Clear water pump set (For Boosting Station) 1600 LPM x 50 Mtr. Head
Supplying, erection, testing of fully automation electric control panel board for Boosting Station in Boosting Chamber consisting of M.S. sheet of thickness 14 gauge duly painted box type floor mounted made of angle frame 50 x 50 x 6mm duly spray painted containing 1 No. fully automatic oil immersed starter suitable for motor, Main switch of suitable range with HRC fuse, 1 No. volt meter (0 to 500 volts), 1 No. amp. meter of 0 to 100 amp, 3 sets of indicating lamp, capacitor of suitable capacity 1 No. single phase preventors with the timer switch including wiring in panel board with earthing arrangement and wiring from DHBVN supply to panel board complete in all respect. Suitable For 1600 LPM x 50 Mtr. Head
Supplying and fixing D/F pipes/ made of C.I. pipe Class-B (medium duty) of reputed make i.e. Jindal/Parkash/Tata of laying length for making flanged column pipes inside & outside of Boosting Chamber & UGT including cutting, threading, welding of M.S. flanges on both ends & jointing with nut bolts, rubber sheet complete.For Horizontal Spindle Splt casing type pumping set for MBS at source.CI D/F Pipes 150 mm i/d
Gantry of 2 Tones capacity with traveling trolley of appropriate lifting capacity for handling of pumping sets, capable of moving along the girders in the Boosting chamber of size 14'x24' for BS at source.
Operation & Maintenance of water works (disinfection material supplied by the PHED. As per schedule-IV for a period of 5 years (60 months) after three 3 months of trial run (will be charged to the A/Mtc. Estimate). Operation & Maintenance during the defect liability period (Operation only)
1st year Operation & Maintenance after defect liability period
2nd year Operation & Maintenance.
3rd year Operation & Maintenance.
4th year Operation & Maintenance.
Bedha Patti Supplying & erection of horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No.II complete in all respect with complete base frame. Clear water pump set (For Boosting Station) 2100 LPM x 50 Mtr. Head
Supplying, erection, testing of fully automation electric control panel board for Boosting Station in Boosting Chamber consisting of M.S. sheet of thickness 14 gauge duly painted box type floor mounted made of angle frame 50 x 50 x 6mm duly spray painted containing 1 No. fully automatic oil immersed starter suitable for motor, Main switch of suitable range with HRC fuse, 1 No. volt meter (0 to 500 volts), 1 No. amp. meter of 0 to 100 amp, 3 sets of indicating lamp, capacitor of suitable capacity 1 No. single phase preventors with the timer switch including wiring in panel board with earthing arrangement and wiring from DHBVN supply to panel board complete in all respect. Suitable For 2100 LPM x 50 Mtr. Head
Supplying and fixing D/F pipes/ made of C.I. pipe Class-B (medium duty) of reputed make i.e. Jindal/Parkash/Tata of laying length for making flanged column pipes inside & outside of Boosting Chamber & UGT including cutting, threading, welding of M.S. flanges on both ends & jointing with nut bolts, rubber sheet complete.For Horizontal Spindle Splt casing type pumping set for MBS at source.CI D/F Pipes 150 mm i/d
Gantry of 2 Tones capacity with traveling trolley of appropriate lifting capacity for handling of pumping sets, capable of moving along the girders in the Boosting chamber of size 14'x24' for BS at source.
Operation & Maintenance of water works (disinfection material supplied by the PHED. As per schedule-IV for a period of 5 years (60 months) after three 3 months of trial run (will be charged to the A/Mtc. Estimate). Operation & Maintenance during the defect liability period (Operation only)
1st year Operation & Maintenance after defect liability period
2nd year Operation & Maintenance.
3rd year Operation & Maintenance.
4th year Operation & Maintenance.
Bidder Name
Amount
Ranbir Singh(GSTN-NA)
JAIBIR SINGH CONTRACTOR(GSTN-NA)
M/S AAR PEE CONSTRUCTION COMPANY JIND(GSTN-NA)
JAIBIR SINGH CONTRACTOR
Ranbir Singh
M/S AAR PEE CONSTRUCTION COMPANY JIND
JAIBIR SINGH CONTRACTOR
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .