Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 LAccepted-AOC SECTOR 27 1001 GH 13 134116 | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹1.7 L Quoted ₹1.1 L | L1 | Accepted-AOC L1 |
| 2 | L2₹1.1 LRejected-AOC | ₹1.1 L | L2 | Rejected-AOC L2 |
| 3 | L3₹1.7 LRejected-AOC SHOP NO 137 38 NEW MOTOR MARKET MANIMAJRA CHANDIGARH | CHANDIGARH | CHANDIGARH | CHANDIGARH | ₹1.7 L | L3 | Rejected-AOC L3 |
| 4 | L4₹1.7 LRejected-AOC | ₹1.7 L | L4 | Rejected-AOC L4 |
Tender Value
₹1.7 L
EMD Value
₹3,400
Closing Date
23 Apr 2026, 12:00 pmClosed
Narender Kumar Payal
DIV 2 Panchkula
Rewinding of 100HP induction motor at W/works Sector 5 MDC Panchkula and other related water supply assets contingent thereto (A/mtc of PH services in Sector 1 to 6, MDC and Sector 23 to 28, 31 and 32, Panchkula Extension)
2026_HBC_515854_1
202611F53AF8 A3B1 4DED 8BA3 5BFE0C9F1BFE270HSV
Open Tender
Civil Works
30 days
Panchkula
2 documents required · 2 mandatory
₹250
₹3,400
Yes
19 May 2026
17 Apr 2026
23 Apr 2026
17 Apr 2026
23 Apr 2026
17 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | [20.11.5]Providing and fixing cast iron double flanged swing check type reflux (non return) valves PN-1.6 marked with IS:5312 including nuts and bolts marked with IS:1363, rubber sheet marked with IS:638 etc., carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect to the satisfaction of Engineer-in-charge 5. 250 mm i/d | - | Each | 14,304 | - | BI01010001010000000000000515BI0100001113 |
| 2 | [20.114.1]Supplying erection, testing of fully
automatic electric control panel board for
T/Wells in Pump Chamber consisting of
MS sheet of thickness 14 gauge duly
painted box type floor mounted made of
angle Frame containing 1 no. fully
automatic air brake starter suitable for
Motor of the following capacity, Min
switch of suitable range with HRC fuse, 1
no. volt meter (0 to 500 volts), 1 No.
Amp. Meter of 0 to 100 amp. 3 sets of
indicating lamp capacitor of suitable
capacity and 1 no. single phase preventers
with the timer switch including wiring in
panel board and suitable electric energy
meter wiring in Electric Control Panel
Board complete in all respect as per
specification given in Schedule No. II,
Including MCB, suitable, Capacitor,
Wooden Box etc as per site
requirement complete in all respect. 1. 10 HP Motor | - | Each | 11,595 | - | BI01010001010000000000000515BI0100001114 |
| 3 | [23.22.1.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.5. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA | - | Each | 8,577 | - | BI01010001010000000000000515BI0100001115 |
| 4 | [23.22.8.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.3. SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 200 amp 415 volts | - | Each | 14,959 | - | BI01010001010000000000000515BI0100001116 |
| 5 | [24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. | - | Metre | 730 | - | BI01010001010000000000000515BI0100001117 |
| 6 | [24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. | - | Each | 8,275 | - | BI01010001010000000000000515BI0100001118 |
| 7 | [24.5.1.6]MISCELLANEOUS ITEMS 1.6. Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge.
Submersible Copper Cable 3 Core 16 sqmm | - | Metre | 281 | - | BI01010001010000000000000515BI0100001119 |
| 8 | Rewinding of 100 HP induction motor inluding P/F of super Enamel copper wire, F class synthetic paper, glass paper. F class glasa tape roll, glass sleeve f class, varnish Dr. beck, red bectol, epoxy hardener, glass wire 35 Sq mm, labor charges for motor winding, opening and refitting of motor, making of motor pump alignment, coupling fixing, testing etc complete in all respect as per entire satisfaction of engineer-in-charge | - | NO. | 53,000 | - | BI01010001010000000000000515BI0100001120 |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.88 MB
BOQ_594701.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid