Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹39.9 L+₹1.3 L (3.32%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹43.5 L+₹4.9 L (12.8%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹46.8 L+₹8.2 L (21.3%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹48.0 L+₹9.4 L (24.3%)Rejected-Finance 97 19 JWALA HERI PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
31 Aug 2023, 6:00 pmClosed
GE (EAST) DELHI CANTT-10
GE (EAST) DELHI CANTT-10
PROVN OF AIR CONDITIONING WORKS AT SURGICAL AND PROVN OF WALL PANELING AT BHDC UNDER GE (EAST) DELHI CANTT-10
2023_MES_612038_1
GE/DE-60/2023-24
Open Tender
Civil Works
Item Rate
120 days
GE (EAST) DELHI CANTT-10
Class D Cat c (i)
8 documents required · 8 mandatory
₹500
Yes
GE (EAST) DELHI CANTT-10
₹90,000
Yes
13 Sept 2023
3 Aug 2023
2 Sept 2023
3 Aug 2023
31 Aug 2023
17 Aug 2023
Amount
Supply Installation Testing and Commissioning of modular type capacity 20 HP Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor Units suitable for cooling and heating , having all hermetically sealed inverter type Scroll Compressor(s), ,microprocessor based controller, Top discharge type condensing units with R410 A refrigerant , vibration isolators with suitable foundation etc. complete as required . The compressor and VRF should be of same make. The outdoor should deliver 100% capacity at 39 Deg C . The unit shall deliver the rated capacity at AHRI conditions and work even at 53 Deg C ambient temperature without tripping. The unit shall be suitable to work on 400 V+/-10% 3 phase , 50 Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.73 and IEER not less than 8 complete all as specified and directed. (Make: DAIKIN/LG/BLUESTAR)
Supply Installation Testing and Commissioning of modular type capacity 14 HP Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor Units suitable for cooling and heating , having all hermetically sealed inverter type Scroll Compressor(s), ,microprocessor based controller, Top discharge type condensing units with R410 A refrigerant , vibration isolators with suitable foundation etc. complete as required . The compressor and VRF should be of same make. The outdoor should deliver 100% capacity at 39 Deg C . The unit shall deliver the rated capacity at AHRI conditions and work even at 53 Deg C ambient temperature without tripping. The unit shall be suitable to work on 400 V+/-10% 3 phase , 50 Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.73 and IEER not less than 8 complete all as specified and directed. (Make: DAIKIN/LG/BLUESTAR)
Supply installation,testing and commissioning capacity 1.2 TR of following minimum capacity VRF 4-way cassette compact Type Indoor unit equipped with washable synthetic media pre filetr fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve ,outer cabinet cord less remote control , drain pan necessary accessories etc suitable for operation on 230 V +- 10% 50 Hz single phase AC supply complete as required . The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS system. The cooling capacity of Indoor Unit will be at air inlet conditions of 27 Deg C DB and 19 deg C WB temperature complete all as specified and directed. (Make: DAIKIN/LG/BLUESTAR)
Supply installation,testing and commissioning capacity 1.75 TR of following minimum capacity VRF 4-way cassette compact Type Indoor unit equipped with washable synthetic media pre filetr fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve ,outer cabinet cord less remote control , drain pan necessary accessories etc suitable for operation on 230 V +- 10% 50 Hz single phase AC supply complete as required . The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS system. The cooling capacity of Indoor Unit will be at air inlet conditions of 27 Deg C DB and 19 deg C WB temperature complete all as specified and directed. (Make: DAIKIN/LG/BLUESTAR)
Supply installation,testing and commissioning capacity 2.0 TR of following minimum capacity VRF 2-way Cassette Indoor unit equipped with washable synthetic media pre filetr fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve ,outer cabinet cord less remote control , drain pan necessary accessories etc suitable for operation on 230 V +- 10% 50 Hz single phase AC supply complete as required . The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS system. The cooling capacity of Indoor Unit will be at air inlet conditions of 27 Deg C DB and 19 deg C WB temperature complete all as specified and directed. (Make: DAIKIN/LG/BLUESTAR)
S & F Wireless Remote controller for indoor cassette unit
S & F Centralized remote controller- AC Ez Touch
Supply, fixing and commissioning of refrigerant Y joint / Branch distibutors indoor to outdoor complete with nitrile rubber insulation, supporting etc.,
Supply, fixing and commissioning of refrigerant Y joint / Branch distibutors between Outdoors complete with nitrile rubber insulation, supporting etc.,
Supply installation testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRF/VRV system,complete with fittings,with suitable adjustable ring type hanger supports,jointng/brazing including accesories insulated with XLPE Class O tubular insulation/with Class O closed cell elastemeric nitrile rubber tubular sleeves sections of specified thickness as below for Suction and Liquid lines, all accessories as per specification etc as required:
(a) 6.4 mm dia (OD) (soft drawn) with tube thickness 1.2 mm with 19mm thick insulation
(b) 9.5 mm dia (OD) (soft drawn) with tube thickness 1.2 mm with 19mm thick insulation
(c) 12.7 mm dia (OD) (soft drawn) with tube thickness 1.2 mm with 19mm thick insulation
(d) 15.86 mm dia (OD) (soft drawn) with tube thickness 1.2 mm with 19mm thick insulation
(e) 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation
(f) 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation
(g) 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation
(h) 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation
Supply and fixing Rigid PVC piping complete with fittings, supports and duly covered with 6 mm thick closed cell nitril rubber insulation complete all as specified and directed. Note : Providing and fixing in position the following size of PVC (UPVC quality) pipes, cut in required lengths and joined with PVC cement and also providing and fixing in position the necessary "U" trap elbows, tees, and reducer and all types of fittings. Cost to include all necessary as required. Necessary Wall cutting and making the wall good and its cost should be included. The pipe to be insulated by 9mm thick nitrile rubber thermal insulation of class 0 category.
(a) 25 mm dia ( with 6 mm nitrile rubber Insulation)
(b) 32 mm dia ( with 6 mm nitrile rubber Insulation)
(c) 40 mm dia ( with 6 mm nitrile rubber Insulation)
Supply and Fixing of Covered GI Perforated cable / pipe tray for running refrigerant piping and cable alongwith control wiring etc. tray should be properly clamped and hang with all connected accessories and it should be of following sizes.(For exposed Cable / Pipe only ) (a) 300 x 50 x 1.6 mm
Supply & installation of control cum transmission wiring of 2 core x 1.5 sqmm copper in suitable pvc conduits between indoor and out door unit.
Supply and fixing of pvc conduit along with accessories in surface / recess for control cable 25 mm dia
Supply and laying / fixing on surface of Power cable of following sizes XLPE insulated copper armoured conductor cable to VRF outdoor unit from main electrical panal. The cost shall include allnecessary supports clamps etc as necessary as required. (a) 4C x 10 sqmm
Supply, making end termination with brass compression gland and aluminium lugs for following sizes of PVC insulated and PVC sheathed/XLPE aluminium condutor cable of 1.1 KV grade as required. (a ) 4C x 10 sqmm
Supply and fixing of power socket with plug for Indoor Unit
Refrigerant gas R-410 for top up
Supply & erection of MS angle, channel and structure for supporting of indoor units, making stand of outdoor units, supporting for ducting etc . with 2 coat of primer & painted
Supply, Laying, jointing and testing of electric cable XLPE 3.5 Core 120 sqmm insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation /fixing pole / laying cable and pipe line etc or for man hole etc n.exc 10 sqm on plan and getting out in any type of soil complete all as specified and directed
Returning filling in including spreading leveling, watering and well ramming in layers not exc any type of soil complete all as specified and directed
Removing the excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed
Supply and laying common burnt bricks of sub class ‘B’ laid flat at right angle on the cable complete all as directed in trenches for cable protection complete all as specified and directed
M&L for providing dry river sand as in sand cushioning to under ground electric cable including punning down of sand in layer complete all as specified and directed Note: for measurement purpose punned thicness of sand only will be considered.
M&L for earthing complete with galvanised iron earth plate electrod 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25 mtrs deep below normal grond level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth GI wire of size 4mm by means of GI nut, bolts and washers or steel as shown in electrical plate No. 3 of SSR part-I and connected to earth GI wire on main switch board all as specified and testing on completion including provision of earth wire protection by 15 mm dia GI Tubing, light grade and watering pipe shall be 20 mm bore GI light grade including excavation & earth work, PCC pit with CI cover, charcoal, salt, funnel, wire mesh,GI wire up to 7.5 mtrs length complete all as specified and directed.
M&L for Earth continuity conductor fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm dia galvanised iron strip
Supply and fixing of 125mm deep Antivibration Flexible Joints made out of imported fire retardant fabric with extruded aluminium frame/ flange on both sides for Outdoor Units & AHU.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion including provision of 40 mm GI Tubing, light grade and watering pipe shall be 20 mm bore GI light grade including excavation & earth work, PCC pit with CI cover, Charcol, salt, funnel, wire mesh, GI strip Up to 7.5 mtrs length complete all as specified and directed.
Supply and fixing of MS Stand as per OEM Recommendation and Placing of Outdour Unit on MS Stand of C Channel.
Supply and installation, testing, commissioning Outdoor type feeder piller Box made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply factory made & MS angle section 40 x40x 5mm frame with front and back openable double door with provision of locking arrangement dust & varmin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof duly spray painted inside and outside of panel with one coat of red oxide primer and two coat of synthetic enamel paint grey complete all as specifed abd directed & Connisting of the following equipments:- (i) MCCB, 4 pole , 25 KA , 250 Amps adjustable to thermal Magnetic Release -01 No ( Incomming) (ii) MCCB , 4 pole , 25 KA, 125 Amps -01 No (Out going) (iii) MCCB, 4 Pole, 16 KA, 63 Amps -03 Nos, thermal Magnetic MAKE- Schneider/Siemens/Socomec) (iv) Indication Lamp 22.5 mm dia LED type 240Volts AC to show three phase availability- 01 set MAKE : L & T/Secure/Conserv (v) Solid aluminium bus bar 400 Amp for 3 phase , 200 Amp for neutral (vi) PCC and block Mesonry work for grouting of panel complete all as specified and directed
S & F distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof , TPN 12 way with 200 Amps rated copper busbar, 415 Volts with in built MCCB 125 Amps, 25 KA, 01 No., earth bar IP 43 protection, flush to wall complete all as specified and directed. Make : Legrand/Siemens/ Schnieder
S & F MCB SP 2A to 40A complete all as specified and directed. Make - Havells/Legrend/Crabtree
M&L for control wiring with 3 core X 1.5 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 32 mm dia as per IS 694 complete all as specified and directed Make : Finloex/Havells/Polycab (Note : Two run of wire with PVC conduit will be considered as one Length.)
S&F Solid PVC Wall lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame complete all as specified and directed.
RUCHIKA ENGG.WORKS
ASHUTOSH BUILDERS
shivrefrigeration
RefAir Technical Services
M P TYAGI ENGINEERS AND CONTRACTORS
Vishal Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .