Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.5 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹10.9 L+₹36,937.20 (3.51%)Rejected-Finance | L2 | Rejected-Finance Rejected in AOC |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
19 Feb 2022, 6:00 pmClosed
GE ARMY SURATGARH
SURATGARH MIL STN
Repair / maint of LT overhead line, LT UG cable, LT panel, APFC panel and connected items at CETC, SASF, ASCON Nodes and other misc units under GE (Army) Suratgarh at Suratgarh Mil Stn
2022_MES_503227_1
GE (A) SOG - 54/21-22
Open Tender
Civil Works
Item Rate
330 days
SURATGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ARMY SURATGARH
₹30,000
Yes
28 Feb 2022
22 Jan 2022
21 Feb 2022
22 Jan 2022
19 Feb 2022
5 Feb 2022
Amount
Dismantling existing unserviceable Aluminium conductors, steel reinforced (ACSR conductor) from overhead lines on LT poles, of any type and any size complete all as specified and as directed by Engineer-in-charge
Disconnecting and re-stretching ACSR conductor of any size and re-fixing with and including new 2mm dia aluminum binding wire complete all as specified. Note :- (i) The rate quoted by the contractor shall deemed to be included for cutting / trimming of tree branches touching / approaching the LT over lines upto 3 metre width on each side with hacksaw / axe to clear the LT line including disposal of trimmed branches 100 metre away inside the cantonment area & cleaning site as directed by Engineer-in-charge. (ii) Length of each conductor shall be measured as one length.
Supplying, fixing & stretching aluminium conductor steel, reinforced (ACSR) of any size fixed on LT poles fixed on insulators and binding with & including 2 mm binding wire complete all as specified and directed by Engineer-in-Charge. Notes: - (i) The ACSR conductors shall be conforming to IS-398 (Part-II) and as specified in SSR Part-I. (ii) The unit rate quoted shall also be deemed to include for supply and fixing of binding wire, aluminum tapes etc. which shall not be included in the weight of conductors for payment. (iii) Weight of conductors shall be determined by measuring the horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size multiplied by length of span and 3% extra shall be added for sag, jointing, jumpers etc. (iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS.
S&F in replacement shackle type insulators, vitreous porcelain white, brown or green for working pressure 1100 volts grade of 100 mm height and 115 mm dia including galvanized mild steel straps of 31mm x 5mm size,14mm dia insulator bolts, washers and nuts complete all as specified and directed by Engineer-in-Charge.
S&F in replacement pin type insulator of size 100mm height, 65 mm dia porcelain, vitreous white, brown or green insulator suitable for 1100 volts grade including one galvanized mild steel spindle, two GI washer and one GI nut complete all as specified and directed by Engineer-in-Charge.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-charge
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation of poles, filling & mass concrete including necessary form work complete all as specified and directed by Engineer-in-charge .
M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation for stays & mass concrete including necessary form work and fair finishing complete all as specified and directed by Engineer-in-charge
Suppyling, installing, testing in replacement and commissioning of factory made outdoor type bus bar chamber outer shell shall be made out of 3.15mm thick CRCA sheet duly powder coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with double door fix with hinges and locking arrangements etc suitables to accomodate the 200 Amps aluminium bus bar fixed horizontally in staggred manner minimum length 450mm, 3 phases and neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty DMC insulators including provision for taking out incoming and outgoing cable detacheable plate at bottom for cable entry and making six Nos hole in each bus bar including with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm complete all as specified and directed by Engineer-in-Charge.
Inspection/checking of APFC panel 3 phase, 440 voltage 50 Hz AC supply system to improve power factor 0.80 to 0.98 automatic step wise switched capacitor panel to make it serviceable with the help of connecting relays, capacitors, contactors, MCB's, CT's etc and rectifying the defects, replacement of unserviceable part as required at site and cleaning of AMF panel as detecting during inspection or pointed out by users/department and carry out maintenance complete all as specified as directed by Engineer-in-charge. Note:- Spare parts required shall be measured and paid for separately under respective items of BOQ as supply only..
Supply only in replacement of AIPFC micro processor based relay 4 Stage PFC CONTROLLER-BR-4904-04 ST RELAY 230V complete all as specified and as directed by Engineer in charge.. Make - L & T /GE / EPCOS / Siemens / Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of AIPFC micro processor based relay 8 Stage PFC CONTROLLER-BR-4000-08 ST RELAY 230V complete all as specified and as directed by Engineer in charge.. Make - L & T /GE / EPCOS / Siemens / Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 1 KVAR complete all as specified and as directed by Engineer in charge. Make - Epcos Cat part- B32447A4012B 40 / GE/L& T / Siemens / Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 2 KVAR complete all as specified and as directed by Engineer in charge.. Make - Epcos Cat part- B32447A4022B 40 / GE / L& T / Siemens / Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 3 KVAR complete all as specified and as directed by Engineer in charge.. Make - Epcos Cat part- B32448A4032B 40 / GE/L& T / Siemens /Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 5 KVAR complete all as specified and as directed by Engineer in charge. Make - Epcos Cat part- B32448A4052B 40 / GE / L& T / Siemens /Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 10 KVAR complete all as specified and as directed by Engineer in charge. Make - Epcos Cat part- B32448A4102B 40 / GE / L& T / Siemens / Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 15 KVAR complete all as specified and as directed by Engineer in charge.. Make - Epcos Cat part- B32448A4122B540 / GE / L& T / Siemens /Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Capacitor duty contactors 3 Phase suitable up to 10 KVAR cap Duty cont 1 NO1NC240V complete all as specified and as directed by Engineer in charge.. Make - EPCOS Cat Part No B44066S1011C240N 1 or Equvilent in L&T / GE / Siemens / Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Capacitor duty contactors 3 Phase suitable up to 16 KVAR cap Duty cont 1 NO1NC240V complete all as specified and as directed by Engineer in charge. Make - EPCOS Cat Part No B44066S1611C240N 1 or Equvilent in L&T / GE / Siemens / Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of current transformer of ratio 100/5, 5 VA with accuracy class 1.0 including connection with 2.5 sqmm twin core PVC cable complete all as specified and as directed by Engineer in charge.
S&F in replacement pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 172mm at top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1998 erecting truly in vertical position including painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30cm each in black and yellow colour up to 1.5 metre height from top of PCC pedestal/coping of poles including numbering of poles with synthetic enamel paint black in 80mm high letters over 150mm x 230mm yellow base made from synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Note : PCC for foundation and earth work shall be measured and paid for separately.
S&F in replacement MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408587 to 408595 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement MCB, Triple Pole 40 Amps, , 415 volts, having breaking capacity 10 KA, 'C' Curve complete all as specified and directed by Engineer-in-Charge. Make :- Legrand Cat Part No 408659 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement MCB 63 Amps, four pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408702 or equivalent in makes mentioned in Appendix 'A' here-in-after.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade of length 2.25 metre and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mmthick pre-cast RCC (1:2:4) type B-0 cover with 40mm x 40mm x 3mm MS angle iron frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 including taking down old earthing complete all as specified and directed by Engineer-in-charge. Notes :- (i) GI strip upto earth test point/equipment is included in this item. (ii) Outer edge of earth pit shall be 1.5 metre away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement for earth pit cover shall be 1 kg .
Laying, jointing, commissioning and testing in replacement XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 240 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions. (iii) Cable required for laying shall be issued under Schedule 'B' free for fixing only.
All as per item No 27 above but cable of cross sectional area 185 sq mm 3.5 core
All as per item No 27 above but cable of cross sectional area 120 sq mm 3.5 core
All as per item No 27 above but cable of cross sectional area 95 sq mm 3.5 core
All as per item No 27 above but cable of cross sectional area 16 sq mm 4 core
Supplying, laying, jointing, commissioning and testing in replacement XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 95 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc including taking down old unserviceable cable complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
All as per item No 32 above but cable of cross sectional area 70 sq mm 3.5 core
All as per item No 32 above but cable of cross sectional area 25 sq mm 3.5 core
All as per item No 32 above but cable of cross sectional area 16 sq mm 2 core
All as per item No 32 above but cable of cross sectional area 10 sq mm 2 core
Supplying, jointing and testing heat shrinkable type straight through jointing kit, suitable for cable of size 16 to 50 Sqmm, 3.5 core aluminium conductor 1100 Volts including making connections complete all as specified and directed by Engineer-in-Charge.
All as per item No 37 above but suitable for cable of size 70 sqmm to 120 sqmm.
All as per item No 37 above but suitable for cable of size 150 sqmm to 185 sqmm.
All as per item No 37 above but suitable for cable of size 240 sqmm to 300 sqmm.
Supplying, jointing and testing heat shrinkable type, in / out door, end termination jointing kit, suitable for cable of size 25 to 50 Sqmm, 3.5 core aluminium conductor 1100 Volts including making connections complete all as specified and directed by Engineer-in-Charge.
All as per item No 41 above but suitable for cable of size 70 sqmm to 120 sqmm.
All as per item No 41 above but suitable for cable of size 150 sqmm to 185 sqmm.
All as per item No 41 above but suitable for cable of size 240 sqmm to 300 sqmm.
Cutting/ trimming of tree branches not exc 10cm girth touching/approaching the LT / HT overhead lines upto 3 metre width on each side with hacksaw/axe to clear the LT / HT line including disposal of trimmed branches 100 Metre away inside the cantonment area & clearing site complete all as specified and directed by Engineer-in-Charge. (Approximate length of span 40 to 50 metre) Note:-The contractor shall be responsible to maintain this item of work till the date of completion work. Nothing shall extra be paid on this account.
Taking out old unserviceable underground LT Cable with standad aluminium conductor 1100 volts grade cross sectional area upto 95 Sqmm form trenches / floor / road / pipe / along poles and relaying in the same location after repair complete all as specified and directed by Engineer-in-Charge. Note : Excavation & earthwork shall be measured and paid seperately under respective items of BOQ.
All as per item No 46 above but cable of cross sectional area 120 sqmm to 300 sqmm
S&F in replacement cross arms, bracings, stiffeners, supports, clamps and back plates fabricated from structural steel confirming to Fe-290 (Gde E-165) including nuts, bolts, washers, welding, binding cold or hot, drilling holes for bolts, in any shape or size complete all as specified and directed by Engr-in-Charge. Note :Exposed steel surface shall be treated with two coats of synthetic enamel paint over a coat of red oxide primer and unexposed surface of steel sections shall be applied one coat of red oxide primer.
S&F in replacement stay assembly complete with accessories as shown in electrical plate No 1 using stay rod 20 mm dia x 1800mm long, stay bow 14mm dia and stay plate 30 cm x 30 cm x 6 mm including stay wire 8 SWG x 7 strands, loop type insulator with over all dimensions 90x140mm and clearence of hole 25.5mm, stay clamps and painting to exposed surfaces of mild steel work with two coats of aluminum paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge. Note : Excavation, earthwork and PCC in foundation shall be measured and paid seperately under respective items of BOQ.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable and water supply / sewage pipe line etc. in soft / loose soil & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
All as per serial item No. 50 here-in-above but depth exc 1.5 mtr & not exc 3mtr
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note: - For payment purpose thickness after punning shall be measured.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable all as specified and directed by Engineer-in-Charge.
S&F in replacement Galvanized iron tubing, 80mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account.
All as per item No 56 above but 50mm bore tubing
All as per item No 56 above but 40mm bore tubing
M&L for preparation of existing painted surfaces of Panel Board / Feeder Pillar box (indoor / outdoor type), area not exceeding 10 square metre each and applying one coat of synthetic enamel paint after preparation of surfaces on external and internal surfaces of approved tint by using spray machine inclusive of writing SM / MES No / name of feeders etc. (not exceeding of height 5 cm each) including welding of broken panel door, tightening electric connection of switch gears and cleaning of vegetation all around the panels up to one meter from all sides complete all as specified and as directed by Engineer-in-charge.
S&F in replacement MCCB 4 Pole 100 Amps, thermal magnetic release having, breaking capacity 25 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections complete all as specified and as directed by Engineer-in-Charge. Make : Legrand Cat Part No. DPX³ 160 420055 or equivalent in makes mentioned in Appendix 'A' here-in-after.
All as per item No. 60 here-in-before but MCCB 4 Pole, 160 Amps rating, breaking capacity 36 KA, 415 Volt Make : Legrand Cat Part No. DPX³ 160 420097 or equivalent in makes mentioned in Appendix 'A' here-in-after.
All as per item No. 60 here-in-before but MCCB 4 Pole, 250 Amps rating, breaking capacity 36 KA, 415 Volt Make : Legrand Cat Part No. DPX³ 250 420249 or equivalent in makes mentioned in Appendix 'A' here-in-after.
All as per item No. 60 here-in-before but MCCB 4 Pole, 400 Amps rating, breaking capacity 36 KA, 415 Volt Make : Legrand Cat Part No. DPX³ 630 422007 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F LT Line polypropylene composite phase separator, moulded or bolted type, overall length 940mm, width 25mm, thickness 12mm, suitable for 4-lines wire complete all as specified and as directed by Engineer-in-charge.
S&F LT Line polypropylene composite phase separator, moulded or bolted type, overall length 1250mm, width 25mm, thickness 12mm, suitable for 5-lines wire complete all as specified and as directed by Engineer-in-charge.
S&F in replacement Digital type Voltmeter 96mm x 96mm, of range 0-500 volts, class -1 complete all as specified & as directed by Engineer-in-charge
S&F in replacement Digital type Ammeter 96mm x 96 mm of range 0-200 Amp, single phase, class -1 complete all as specified & as directed by Engineer-in-charge
S&F in replacement Phase indicator lamp assembly LED type complete with indicator lamp including making connections with 2.5 Sq mm copper conductor PVC insulated and PVC sheathed single core cable complete all as specified and as directed by Engineer-in-charge.
S&F in replacement heavy duty TPN bus bar chamber 100 Amps, 4 way fixed with hinges and locking arrangements, wall mounting type and arrangements for 4 Nos incoming / outgoing connections in each bus bar fixed on wall complete all as specified & directed by Engineer-in-Charge. Make :- Havells Cat Part No IHBC010004 or equivalent in makes mentioned in Appendix 'A' here-in-after.
Disconnecting LT cable connection for repair turbo battery charger 12/24 volts DC of any make, replacement of unserviceable parts, tightening of electric connection, reassembling, making connections and testing complete all as specified and directed by Engineer-in-charge. Note:- The cost of spare parts required to repair / replacement in the item deemed included in the quoted rate. -------------------------------------------------------------------------- Note :- A sum of Rs. 124984/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 27 & 28 (Schedule of Credit) of Tender documents.
BHADU BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .