Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹7,320
Closing Date
17 Dec 2022, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer RNB Srinagar
Executive Engineer RNB Srinagar
Internal Electrification of NTEP State Drug Store inside CD Hospital Dalgate Srinagar
2022_PWDJK_199118_1
E/NIT/153/2022/23dtd09/12/2022
Open Tender
Electrical Works
Item Rate
Internal Electrification of NTEP State Drug Store
As Per BOQ
2 documents required · 2 mandatory
₹200
Executive Engineer RNB Srinagar
₹7,320
17 Dec 2022
9 Dec 2022
17 Dec 2022
9 Dec 2022
17 Dec 2022
9 Dec 2022
Amount
Point wiring for switch controlled primary light points with 2 x1.5 sq mm (P+N) FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor of standard make dully isi marked ( Finolex /Polycab/Havels /Anchor /Paramount make ) to be laid in recessed or surface Conduiting system and the cost of supplying and fixing modular grid.plate mounted flush mounted volts 6 amp control switch of Antibacterial.and antifungal switch dully isi marked of approved quality and colour housed in zinc chromate passivity GI boxes with modular cover plate complete as per specification and as required (Excl cost Of Conduiting).
Point 660/1100 supplying wiring for Ceiling fan points with 2 x1.5 sq mm (P+N) FR PVC insulated volt grade flexible stranded copper conductor wires of standard make dully isi marked ( Finolex / Polycab /Havels / Anchor / Paramount make to be laid in recessed or surface conducting system and incl the cost of and fixing modular grid plate mounted flush mounted 240 volts 6 amp control switch of Antibacterial and antifungal switch apd 2110 volts 300 watt 5 step electronic speed regulator of Antibacterial and antifungal fan regulator and colour housed in zinc chromate passivity GI boxes with modular cover plate and with inter connections complete as per specification and as required. ( Excl cost of Conduiting )
Point wiring for 10 Amp Socket out lets with 3x2.5 sq mm (P+N+E) FR PVC insulated 660/1100 volt grade flexible stranded copper conductor wires Finolex / Polycab / Havels / Anchor / Paramount make ) to be laid in recessed or surface conducting system incl the cost of supplying and fixing modular grid plate mounted flush mounted 3 no's of 240 volts 6 amp 5 pin socket out let along with 16 Amp control Switch of Antibacterial and antifungal and colour housed in zinc chromate passivity GI boxes with modular cover plate and inter connections and including cost of loop Earthing with 2.5 sq mm FRLS PVC Insulated 660/1100 circuit wiring( from DB to first switch in the sub circuit) complete as per specification and as required volt grade flexible stranded copper conductor wires complete as per specifications and as required ( Excl cost of Conduiting)
Point wiring for 16 Amp Socket out lets ( Two out lets wired in one sub circuit ) with 3x4 sq mm (P+N+E) FR PVC insulated 660/1100 volt grade flexible stranded copper conductor wires ( Finolex I Polycab / Havels / Anchor /Paramount make ) to be laid in recessed or surface conducting system and incl the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 16-20 amp 6 pin combined shuttered socket out let along with 240 volt 16-20 Amp control Switch of Antibacterial and antifungal and colour housed in zinc chromate'passivity GI boxes with inter connection complete as per specifications and as required.( Excl cost of conduits)
Supply, Installation, Testing and commissioning of 20-22 watt 4 ft long LED surface mounted light fittings complete having Aluminium body (CRCA) of standard make dully isi marked( Philips / Havells / Helonix / Veto / crompton make ) .
Supply, Installation, Testing and commissioning of 10-12 watt 2 ft long LED surface mounted light fittings complete having Aluminium body (CRCA) of standard make dully isi marked( Philips / Havells / Helonix / Veto / crompton make )
Supply, Installation, Testing and commissioning of 15 watt LED surface mounted light fittings (Square /Rounri ) complete having Aluminium body (CRCA) of standard make dully isi marked Philips / Havells / Helonix / Veto / crompton make )
Supply, Installation, Testing and commissioning of 50 Watt LED Flood lights (IP66) of standard make dully isi marked( Philips/ Havells / Helonix / Veto /C.G make ) incl making of necessary Connections to be fitted on walls with nuts and bolts of sorts.The job includes AMC (reckoned from date of sucessful commissioning) of lighting fixtures for a period of two years ,which includes.
Supply, Installation testing and commissioning of 1400 mm sweep Ceiling Fans of Crompton Greaves / Havel's / Usha / Veto make ( Sample to be got approved ) with ceiling rose of SSK make Complete incl making of necessary connections.
Supply, Installation testing and commisioning of 200 mm sweep Shutter type Exhaust Fans of Usha / Crompton Greaves / Havel's with way ceiling rose of 55K make incl making of necessary con ections and making of necessary space in walls / Windows as per site.
Supply, Installation, Testing and Commissioning of AC/DC Bells of standard make with its batteries.
Supply and fixing modular blanking plates on existing modular switch plates,excluding cost of plates.
Supply, Installation, Testing and Commissioning of Double Door Distribution Boxes to be recessed in walls incl refacing of walls of Legrend / L&T /ABB /Schinder /SSK /simens make complete job with making of all necessary
Supply,Laying ,connecting ,testing and commissioning of ( 2 x 10 SQ. mm + 1 x 10 SQ. MM ) FRLS PVC Insulated multistranded copper wire of standard make dully ISI Marked ( Finolex / Polycab / Havels / Anchor / Paramount make ) including making of end termination and connection complete job ) for Lighting Sub main and AC Points
Supply ,Laying ,connecting ,testing and commissioning of ( 2 x 4 SQ. mm FRLS PVC Insulated multistranded copper wire of standard make dully ISI Marked ( Finolex / Polycab / Havels / Anchor / Paramount make ) including making of end termination and connection complete job ) .
Supply,Laying ,connecting ,testing and commissioning of ( 2 x 2.5 SQ. mm FRLS PVC Insulated multistranded copper wire of standard make dully ISI marked ( Finolex / Polycab / Havels / Anchor / Paramount make ) including making of end termination and connection complete job ) .
Supply and fixing of AC Boxes having provided and fitted with 25-32 Amps Switch-Socket of modular GI Boxes and 3-Pin top for AC Points
Supply and Fixing of medium grade PVC conduit incl its allied accessories like bends.etc for laying of wires recessed in walls incl refacing of walls or final with necessary cliffs and rowel plugs complete.(25/31 mm dia ) The Job includes refacing of walls and floors to original position
Supplying and fixing 63 Amps DP 240/415 volts "C" curve MCB of Legrand / ABB/ Siemens / L&T make suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required for AC Points .
Supplying and fixing 32-40 Amps DP 240/415 volts "C" curve MCB of Legrand / ABB/ Siemens / L&T /Schinder make suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required for AC Points
Supplying and fixing of 5 Amps to 32 Amp S Pole rating 240/415 volts "C"curve MCB of Legrand /ABB/ Siemens / L&T/Schinder, make suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required.
Supplying and Fixing of Cat 5, PCB based RJ-45 UTP Information Outlet with face plates of Antibacterial and antifungal laid in recessed zinc chromate passivated MS box, cable bend limiting, strain relief caps for voice communication as per TIA / EIA 568-B.2-1 standard in existing floor recessed box/ recessed galvanized MS box complete as per specifications and as required.
Providing and fixing of a single telephone cord grid plate mounted outlet unit (RJ-11) with moulded cover plate of Antibacterial and antifungal switch in recessed zinc chromate passivated MS box or in existing floor outlet box complete as required for telephone system with telephone wiring for points
Wiring for telephone points with 4 pair 0.61 mm annealed tinned electrolytic copper conductor PVC insulated unshielded twisted wire in existing surface/concealed conduit/floor raceways up to central point complete as required for telephone system
Supply, Installation, Testing and Commissioning of MDF ( Krone type) 10 Pair with IPM fuses
Supplying, laying, drawing and of UPT 4-pair CAT 6-LAN cable drawn partly in,existing recessed/surface conduits, partly in existing recessed/ surface a mounted raceways and partly in existing cable ducts in modular furniture complete as per specifications and as required for net points and CCTV.
Supply , Installation, Testing and Commissioning of 16 Port Networking Switch of D-Link make
Supply, Installation, Testing and commissioning of lockable 4 U with 5A strip and two fan for distribution mounting of patch Panels hubs switches, compete fully loaded of Dlink make
edison electricals
stage.html
html • 0.02 MB
finance_530824.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .