| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 LRejected-Finance | L1 | Rejected-Finance Bid cancelled due to absurd quoting |
Tender Value
₹2.5 L
EMD Value
₹5,086
Closing Date
5 Sept 2024, 3:00 pmClosed
Executive Engineer (E), BSNL, Bhubaneswar
Door Sanchar Bhawan, Unit-IX, Bhubaneswar-751022
AMC of Split AC and WAC units
2024_BSNL_206095_1
NIT NO- 18/BSNL-EDB/2024-25
Open Tender
Electrical Works
Item Rate
365 days
Bhubaneswar
3 documents required · 3 mandatory
₹590
A O (Cash), BSNL, O/o GMTD, Bhubaneswar.
₹5,086
Yes
17 May 2025
27 Aug 2024
6 Sept 2024
27 Aug 2024
5 Sept 2024
27 Aug 2024
27 Aug 2024 - 2 Sept 2024
Amount
AMC of SPLIT AC / WINDOW AC UNITS
Providing comprehensive maintenance for 1.5 TR Inverter type Split AC units (LG / Hitachi make) along with all accessories etc. as required. The scope of CMC works includes, attending breakdown calls, fault attending, repairing and restoration of AC units within a stipulated time, carry out periodical maintenance and repair works including replacement of faulty Compressors, Fan motors, Blower motors, Fan blades, blower/runner and other spare parts such as PCB, Relays, Capacitors, hand remotes, Batteries for remotes, detection and repairing of leakages in refrigerant pipes, pressure testing, gas charging/top up, repairing of condenser coils (copper), replacement of faulty control switches, MCBs, plugs, plug tops, Stabilizers (if available), replacement of damaged foam insulations, faulty/burnt out wirings between indoor and outdoor units, painting of condenser stands and Base plates (at least once in a Contract period if required) etc. as per the specifications attached as required. ( For 12 months)
Providing comprehensive maintenance for 1.5 TR Window AC units (Carrier / Hitachi make) along with all accessories etc. as required. The scope of CMC works includes, attending breakdown calls, fault attending, repairing and restoration of AC units within a stipulated time, carry out periodical maintenance and repair works including replacement of faulty Compressors, Fan/runner motors, Fan blades, runner and other spare parts such as PCB, Relays, Capacitors, hand remotes, Batteries for remotes, leak detection and repairing of refrigerant pipes, pressure testing, gas charging/top up, repairing of condenser coils (copper), replacement of faulty control switches, MCBs, plugs, plug tops, Stabilizers (if available), painting of condenser stands and Base plates/trays (at least once in a Contract period) etc. as per the specifications attached as required. ( For 12 months)
REPAIRING AND RECTIFICATION OF INITIAL FAULTS
Physical Inspection of the WAC/SAC units ,testing the units ,detecting the fault & assessing the list of materials for repairing the units, rectification of minor faults i/c replacement of spare parts such as condensers, relays etc as reqd. (without materials)
General Servicing of 1.5 /2.0 TR SAC / WAC units of different make i/c cleaning the air filters, de-dusting the condenser and evaporator coils with the help of Blower and water servicing etc. complete as reqd. (cleaning solutions if required shall also be provided).
Charging of Refrigerant gas R-22/R -407 / R -410 up to specified pressure for 1.5 TR WAC/ Split AC units after leak testing , leak rectification i/c testing for proper cooling of the AC units etc. as reqd.
Top up of R-22 / R-407 /R -410 gas in existing Window A.C /Split A.C units, i/c testing etc. as required.
Replacement / repairing of the faulty /damaged spare parts/accessories/components the SAC units by new ones of approved make and capacities/ ratings compatible for 1.5 TR Hitachi / LG /Voltas/Carrier/ Blue Star/ Godrej / Amtrex/ Usha/ Videocon/National make Split AC units of non inverter & fixed speed type, star/non star models. i/c dismantling of the faulty ones and fixing the new ones, connection and testing etc. complete as reqd.
Running / Dual running Capacitor (36-50 / 4 mfd, 440 volts ) . Casing- Aluminium, IS:2993
Capacitor for Blower/Condenser motor, 2- 6mfd, 440 volts
Indoor unit Blower Motor, copper wound, 220-240V, 50Hz, 4 pole.
Indoor unit Blower Motor, copper wound, 220-240V, 50Hz. For Hitachi make AC units
Outdoor unit Condenser Motor, copper wound, 220-240V, 50Hz.
Outdoor unit Condenser Motor, copper wound, 220-240V, 50Hz. (For Hitachi make AC units)
Replacement / repairing of the faulty /damaged spare parts/electrical accessories of the WAC units by new ones of approved make and capacities/ ratings compatible for 1.5 TR Hitachi / LG /Voltas/Carrier/ Blue Star/ Godrej / Amtrex/ Usha/ Videocon/National make WAC units of non inverter & fixed speed type, star/non star models. i/c dismantling of the faulty ones and fixing the new ones, connection and testing etc. complete as reqd.
Starting capacitor(80-120 mfd, 440 volts). Casing- Aluminium, IS:2993
Motor for Window AC units, copper wound, 220-240V, 50Hz, 4 pole.
Fan Blades for 1.5 TR Window units .
Runner for 1.5 TR Window units .
16/25/32 Amps SP MCB (C Class) (Legrand/Havells/L&T/Siemens)
Repairing of the electronic PCB card of the Inverter Split AC indoor unit i/c replacement of defective parts & re-fixing the same in indoor unit ,testing etc as reqd.
Replacement of damaged refrigerant pipe lines of Split AC units by new refrigerant copper pipe for suction & discharge line (size not less than 1/4" & 1/2" dia ) or as recommended by the manufacturer along with expanded polythene foam insulation i/c cutting ,brazing /making joint etc as reqd. The measurement shall be taken on linear basis for one circuit which includes suction & discharge line & foam insulation.
Replacement of faulty compressor of 1.5 TR Split AC /Window AC units by a new Compressor (copper) suitable for working with R22/R410A refrigerant and operation on 220 volts 1-phase, 50 Hz AC supply i/c removing the faulty one, disconnection and reconnection of refrigerant pipes, electrical connections testing etc. complete as reqd. (make-Emerson Copeland /Hitachi/LG/Mitsubishi/GMMC) . The faulty dismantled Compressor may be retained by the firm.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .