Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹28.8 L+₹1.4 L (5.04%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹29.2 L+₹1.8 L (6.57%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹30.0 L+₹2.6 L (9.53%)Rejected-Finance BLOCK NO 306 A SAI NIVAS CHOUDHARY CHOWK JARIPATKA NAGPUR 440014 | NAGPUR | NAGPUR | MAHARASHTRA | 440014 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹30.3 L+₹2.9 L (10.5%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹33.1 L
EMD Value
₹66,200
Closing Date
29 Dec 2022, 6:00 pmClosed
GE Kamptee
GE Kamptee
SPECIAL REPAIRS TO ROOF OF BLDG NO P 83 P 84 P 85 P 208 AND P 209 OF OTM ACCN OF CERTAIN UNIT AND PROVN OF RATION STORE AT 414 ASC BN MKTG TA UNDER GE KAMPTEE
2022_MES_557315_2
8455/E8
Open Tender
Civil Works
Item Rate
180 days
Kamptee Cantt
AS PER NIT
4 documents required · 4 mandatory
₹500
GE Kamptee
₹66,200
Yes
13 Jan 2023
8 Dec 2022
5 Jan 2023
8 Dec 2022
29 Dec 2022
15 Dec 2022
Amount
Taking down existing water proofing treatment including PCC padding, mortar etc and disposal of rubbish outside of MD land and hacking for key, scrubbing down with water complete all as specified and directed.
M&L for 25mm thick cement concrete 1:2:4 type B-0 using 12.50 mm graded stone aggregate as in padding, coping proper slope and gradient, complete all as specified and directed.
M&L for 10mm thick rendering in cement mortar 1:4 on concrete surfaces using with water proofing liquid @ 200 ml/50 kg of cement complete all as specified and directed. Note:- Water proofing liquid will be measured & paid separately.
Supply only liquid integral water proofing admixture of make pidilite or its equivalent complete all as specified and directed.
M&L for provision of water proofing treatment by using APP torch on non woven polyster film reinforcement with 3 mm thick and weight not less than 3.00 kg/sqm over roof and vertical surfaces including preparation of surfaces and applying oil based bituminous primer coat @ 0.30 ltr per sqm on clean and dry surface and then providing APP membrane laid with 100mm over lap on both sides all as per manufacturer's instructions including aluminium paint total 200 gram/sqm in two layers over membrane complete all as specified and directed.
Disconnecting existing tanks, capacity in litres exc 500 ltr and not exc 1000 ltr setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 ltr capacity, hoisted and fixed in position incl top cover incl dismantling of water tank all as specified in SSR part-I complete all as specified and directed.
S&F 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (Minimum weight 20 mm -210 Gms) complete all as specified and directed.
All as per item No 8 above but 25mm bore complete all as specified and directed.
S&F in repairs 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (Minimum weight 20 mm -210 Gms) complete all as specified and directed.
Taking up or down 20mm dia steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 25mm dia steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Refixing 20mm dia old steel tubing and connections in new or old position (Walls, ceiling, floors, etc) complete all as specified and directed.
Refixing 25mm dia old steel tubing and connections in new or old position (Walls, ceiling, floors, etc) complete all as specified and directed.
S&F GI tubing 20mm bore medium grade with all fittings and fixed to wall and ceiling or laid in floor complete all as specified and directed.
S&F GI tubing 25mm bore medium grade with all fittings and fixed to wall and ceiling or laid in floor complete all as specified and directed.
Surface dressing not exc 15cm deep and getting out in soft /loose soil complete all as specified and directed.
Excavation in trenches not exc 1.5m in depth and not exc 1.5m in width for fundation etc or for shafts, wells, cesspits, manholes, pier holes etc. not exc and getting out in hard/dense soil complete all as specified and directed.
M&L for providing cement concrete 1:4:8 type D2 (Using 40mm graded stone aggregate) as in foundation, mass concrete and fillings complete all as specified and directed.
M&L for form work to side of concrete in fdns, footing base, base of columns, side and soffits of plinth beam and similar work complete all as specified and directed.
M&L for providing RCC 1:1 1/2:3 type A-1 (nominal mix) as in footing, foundation, beams, plinth beams, base for columns and mass concrete etc complete all as specified and directed.
M&L for form work to side of columns and similar work for fair finished complete all as specified and directed.
M&L for providing RCC 1:1 1/2:3 type A-1 (nominal mix) as in columns and pillars etc complete all as specified and directed.
M&L for providing RCC 1:1 1/2:3 type A-1 (nominal mix) (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span concrete etc complete all as specified and directed.
M&L for form work to sides and soffits of floor, lintel or roof beams including supports, overhangs etc also splays between floor and beam etc complete for fair finished complete all as specified and directed.
M&L for form work to chullah hoods, chajjas, troughs and similar items including edges and similar work complete all as specified and directed.
M&L for providing RCC 1:1 1/2:3 type A-1 (nominal mix) (using 20mm graded stone aggregate) as in chajja etc complete all as specified and directed.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exc 20cm wide for fair finish complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L for providing RCC 1:1 1/2:3 type A-1 (nominal mix) (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending and binding with mild steel (anneal) wire not less than 0.90mm dia complete all as specified and directed.
S&F mild steel TMT bars 6 to 8 mm dia cut to length, bent to shape required, including cranking, bending and binding spirally for hooping for columns, hooking ends & binding with mild steel (anneal) wire not less than 0.90mm dia complete all as specified and directed.
S&F mild steel TMT bars 5 mm dia & over upto & including 10mm dia as stirrups, spacers and binders cut to length, bent to shape required, binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and directed.
M&L for brick work with fly ash brick old size straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed.
All as per item No 34 above but half brick wall in CM 1:4 complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces with CM 1:6 finished fair and even complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces with CM 1:4 on vertical surfaces complete all as specified and directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment etc complete all as specified and directed.
S&F Mild steel work in Tubular/ square hollow trusses, purlins, rafter and tubular posts including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 Grade St-240 with one shop coat of zinc chromate primer paint etc complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for GI powder coated snap grid framework for false ceiling comprising of the following section for making partition of 600x600 mm size fixed to wall with rawl plug and screw and hanged to roof with 4 mm dia GI suspended wire of suitable length and butterfly clip of size of main Tee shall be 32mm x 15mm x 0.30mm, cross tee shall be 28mm x 15mm x 0.30mm thick with black lining in mid portion and wall angle shall be 24mm x 24mm x 0.30mm thick complete all as specified and directed.
M&L for 4mm thick Non Asbestos, fibre cement building board of size 595x595mm size in ceiling fixed or laid/ inserted to timber/ GI/ Aluminium framework with screws complete all as specified and directed. (Note: GI frame work will be measured and paid for separately.)
M&L for hardcore of gauge not exc. 63mm deposited, spread and levelled in layers not exc 15cm thick watered and rammed to a true surface for plinth protection/ path complete all as specified and directed.
M&L for 75mm thick cement concrete type C-2, 1:4:8 (using 40mm graded stone aggregate) in sub base complete all as specified and directed.
M&L for providing 40mm thick cement concrete 1:2:4 type B1 (Using 20mm graded stone aggregate), as in floors/paving etc complete all as specified and directed.
M&L for pre-polished Machine cut Kota stone slab flooring 20-25 mm thick over cement screed base 20mm thick in CM 1:4 laid and jointed wih grey cement slurry mixed with pigments to match the shade of the slab incl rubbing and polishing complete all as specified and directed.
M&L for pre-polished Machine cut Kota stone slab 18-25 mm thick in riser of steps, skirting, dado and pillar 10 mm thck back plaster in CM 1:4 laid and jointed wih grey cement slurry mixed with pigments to match the shade of the slab complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) Type C2 (using 40mm graded stone aggregate), as in plinth protection and finishing surfaces even & smooth without using extra cement including mastic filling in the joint complete all as specified and directed.
M&L for prepartion of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of wall care putty complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint over a coat of primer on walls complete all as specified and directed.
M&L for MS Framed work of Fe-290(Gde E-165)as in doors or gates of angle or other section with gusset plates, rails, braces, MS Plates etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete etc complete all as specified and directed.
S&F 1.00 mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and directed.
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars dovetailed or welded complete all as specified and directed.
S&F steel ventilator with top hung shutter including hinges, with steel handle, steel tower bolt, peg stay complete all as specified and directed.
S&F framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L for providing cement concrete 1:3:6 type C-1 (Using 20mm graded stone aggregate) as in fixing of hold fast, bed blocks etc includig necessary form work as required complete all as specified and directed.
S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and directed.
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified and directed.
Removing excavated material not exc. 50m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
M&L for point wiring 1100 volt grade single core FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in and including electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marked medium grade concealed in wall/ ceiling including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 1.50 sqmm pressed steel modular boxes sunk on wall for mounting of modular switches, switch sockets, fan regulator etc including modular cover with frame any size complete all as specified and making good disturbed surfaces for one light point controlled by one, one way switch. Note:- Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly.
All as per item No 63 above but one ceiling /exhaust fan point controlled by one switch and regulator complete all as specified and directed.
All as per item No 63 above but one 3 pin 5 amp socket out point on the same board with other switches complete all as specified and directed.
All as per item No 63 above but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 amps power point complete all as specified and directed.
S&F for switch modular type single pole one way 6 amp 1 module 250 volts AC suitable for modular switch boxes complete all as specified and directed. Make :- Anchor / Roma / Legrand / Crabtree
S&F for socket modular type single pole one way 6 amp 2 module 2/3 pin 250 volts AC suitable for modular switch boxes complete all as specified and directed. Make :- Anchor / Roma / Legrand / Crabtree
S&F for switch modular type single pole one way 6/16 amp 3 pin 250 volts AC suitable for modular switch boxes complete all as specified and directed. Make :- Anchor / Roma / Legrand / Crabtree
S&F for socket modular type single pole one way 6/16 amp 2/3 pin 2 module, 250 volts AC suitable for modular switch boxes complete all as specified and directed. Make :- Anchor / Roma / Legrand / Crabtree
S&F ceiling rose surface type 3 terminal 5 amps complete all as specified and directed.
S&F 18-22 Watt LED tube light fittings complete with aluminum body including tube rod, dirver with not less than 2000 Lumen O/P and l/p rated voltage 240 V connecting with 3 core 1 sqmm copper conductor cable complete all as specified and directed. Make & Model : Philips Astra Line CG LDC-20-CDL/ Philips / Wipro / Surya
S&F LED light fitting 10W bulk head luminaires with lamp holders etc complete with all accessories and including connecting upto with twin core twisted flexible cable of suitable size of 230V 50Hz complete all as specified and directed. Make: Bajaj Cat No BIBWP 10W / CG Cat No LBHP 10 CDL / Wipro / Philips / Surya
S&F building security light LED 25 W with Lumen O/P 1800 with driver with rated cvoltage 240 V, 50Hz, including mounting GI (made out of 25mm dia grade pipe 0.8 m bent two shape including FI clamps nout bolts etc complete all as specified and directed. Make : CG LSTS-25-CDL/Philips/Wipro
S&F exhaust fan metallic body 300mm sweep single phase, 230 volts 50Hz with nut and bolts washers etc and connecting up with twin core twisted flexible copper conductor cable of suitable size from fitting to ceiling rose and making holes complete all a sspecified and directed.
S&F sheet metal enclosure single pole & neutral for 240 volts 8 way with 200 Amp rated bus bar flush /surface mounting double door complete all as specified and directed. Make :- Legrand / Havells /L&T
S&F MCB single pole 240 volt 6 to 40 amps 10 KA, complete all as specified and directed. Make:- Legrand / Havells / L&T
S&F MCB single pole & neutral 240 volt 6 to 40 amps 10 KA, complete all as specified and directed. Make:- Legrand / Havells / L&T
Excavation in trenches not exc 1.5m in depth and not exc 1.5m in width for laying of cable trench, pole & stay foundation and getting out in any type of soft/loose soil complete all as specified and directed.
S&F double wall corrugated high density polymer ethyl (HDPE) pipe for laying of electric cable of size 50mm outer dia and 38mm inner dia with IS 14930 (part 2) 2001 and 6mm thickness laid in trenches, wall, poles including bends, sockets and other connected accessories complete all as specified and directed.
Supply and laying in trenches or fixing in walls/ poles or drawing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 10 sqmm 4 core including testing after laid and jointed complete all as specified and directed.
M&L for earthing complete with galvanized street earth plate electrode 600 x 600 x 6mm thick buried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr. below the normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washer of galvanized iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified and testing on completion including the material and labour for:- (a) Excavation and earth work or drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete (1:2:4) type B-1. (c) Pre cast RCC cover with suitable handle 40mm thick in PCC (1:2:4) reinforced with welded steel wire fabric weighting not less than 1.87 Kg/sqmm. (d) Funnel with watering pipe of GI 20mm nominal bore medium grade and Aluminum lugs etc all as specified. (e) 15mm nominal bore medium grade GI protection pipe up to 7.50 meter long for protection of earthing lead. (f) Requisite quantity of charcoal and common salt. (g) Connection to earthing test point and testing on completion.
NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs.2,245.00]
M/S Darshan Singh Plaha
M/s T.S.JOHAR
Manoj Jethani
DEESHA CONSTRUCTIONS
M/s Rana Construction
M/s DS Khekde
DE PRETTY AND CO
Bidder Name
DE PRETTY AND CO
M/S Darshan Singh Plaha
DEESHA CONSTRUCTIONS
M/s Rahul Traders
M/s DS Khekde
Manoj Jethani
M/s Rana Construction
M/s T.S.JOHAR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .