Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹74.3 CrAccepted-AOC ASHOK BAG PLOT NO 16 GAJANAN HOUSING SOCIETY 100 GHUTI ROAD DHAMANI CHOWK SANGLI | SANGLI | SANGLI | MAHARASHTRA | ₹74.3 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹81.5 CrRejected-Finance | ₹81.5 Cr | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical HARSH ANAND YEVALEKAR MALA COLLEGE ROAD NASHIK 422005 | NASHIK | NASHIK | MAHARASHTRA | 422005 | - | - | Rejected-Technical Disqualified |
| 4 | Rejected-Technical | - | - | Rejected-Technical Disqualified |
Tender Value
₹75.9 Cr
EMD Value
₹38 L
Closing Date
16 Feb 2024, 5:30 pmClosed
Executive Engineer P W Dn Kolhapur
Near Head Post Office, Ramnamala Tarabai Park, Kolhapur
Construction of Central Administrative Building Tal. Karveer Dist. Kolhapur (Civil and Electrical)
2024_PWDRP_991356_1
108 for 2023-24 (B2) (OPEN
Open Tender
Civil Works
730 days
Works
Please refer Tender documents.
4 documents required · 4 mandatory
₹13,300
₹38 L
Chief Engineer, P W Region, Pune
21 Mar 2024
26 Jan 2024
20 Feb 2024
26 Jan 2024
16 Feb 2024
26 Jan 2024
6 Feb 2024
Amount
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Mechanical Means
Excavation for foundation in hard murum including removing the excavated material upto a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. (Lift upto 1.5 metre) By Mechanical Means
Excavation for foundation in hard murum and boulders including removing the excavated materials upto a distance of 50 metre beyond the building area and stacking and spreading as directed dewatering preparing the bed for the foundation and necessary back filling, ramming, watering including shoring the strutting excetra complete. (Lift upto 1.5 metre) By Mechanical Means
Excavation for foundation in soft rock and old cement and lime masonry foundations including removing the excavated materials upto a distance of 50 metre beyond the building area and stacking as directed including dewatering, preparing the bed for the foundation and necessary back filling, with available earth, murum, ramming, watering including shoring and strutting excetra complete. By Mechanical Means (Unspecified Lift)
Excavation for foundation in hard rock by chiselling wedging, line drilling excetra including trimming and levelling the bed, removing the excavated materials upto a distance of 50 metres beyond the building area and stacking as directed, dewatering and back filling with available earth / murum, ramming, watering complete. (Lift 1.5 metre TO 3.00 metre) By Mechanical Means
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the bottom surface and sides for excavation at the rate of 5 liters of emulsion concentrates of 1.0 percent of clorophyriphoas per square metre of surface area covering ten years guarantee on bond paper
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyriphoas per square metre of surface area covering ten years guarantee on bond paper.
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 centimetre to 1.5 centimetre diameter about 30 centimetre to 60 centimetre deep at 15 centimetre center to center as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper. (For Ground Floor)
Filling in plinth and floors with approved excavated materials in 15 centimetre to 20 centimetre layers including watering and compacting, excetra complete.
Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND).
Providing and laying Cast in situ / Ready mix cement concrete M-40 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled/ concrete Batch mix plant (Pan mixer) excetra complete. with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).
Providing and laying cast in situ / Ready Mix cement concrete M-40 of trap metal for reinforced cement concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled / concrete Batch mix plant (Pan mixer) excetra complete. With natural sand/V.S.I. quality Artificial Sand (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and laying cast in situ / Ready Mix cement concrete M-40 of trap metal for reinforced cement concrete plinth beams as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled/ concrete Batch mix plant (Pan mixer) excetra complete. With natural sand/V.S.I. quality Artificial Sand (using ARTIFICIAL SAND).
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap metal for reinforced cement concrete plinth beams as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled / concrete Batch mix plant (Pan mixer) excetra complete. With natural sand/V.S.I. quality Artificial Sand (using ARTIFICIAL SAND).
Providing and laying cast in situ / Ready Mix cement concrete M-40 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying / pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and laying cast in situ / Ready Mix cement concrete M-40 of trap/ granite / quartzite/ gneiss metal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks,aying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled / concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and laying cast in situ / Ready Mix Cement concrete M-40 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete pardi of required thickness including centering, formwork, cover blocks, compacting, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and laying cast in situ /Ready Mix cement concrete in M-40 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete waist slab and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood / steel formwork, steel props, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled / concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled / concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and laying Cast in situ / Ready Mix cement concrete M-15 of trap / granite / quartzite / gneiss metal for steps including steel centering, plywood / steel formwork, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing, excetra complete. The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin, excetra (Wooden centering will not be allowed.) with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled / concrete Batch mix plant (Pan mixer) excetra complete. With With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).
Providing and laying in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled / concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).
Providing and laying cast in situ / Ready Mix Cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete pardi of required thickness including centering, formwork, cover blocks, compacting, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).
Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing during laying in reinforced cement concrete slab rectangular 2 milimetre thick mild steel sheet fan hook box of size 180 milimetre X 100 milimetre with required depth with holes or notches as required, bottom and top sides of 1.6 milimetre mild steel sheet fixed with 3.5 milimetre diameter round headed screws together with 12 milimetre diameter mild steel bar bent to shape with hooked ends for fan hook and painting to exposed surface. complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricks in cement mortar 1:6 in foundation and plinth including bailing out water manually, striking joints, racking out joints, watering and scaffolding, excetra complete. (using ARTIFICIAL SAND).
Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricks in cement mortar 1:6 in superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing second class fly ash Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 milimetre diameter / 2 hoop iron strips 25 milimetre X 1.6 milimetre at every third course, properly bent and bounded at ends, scaffolding, racking out joints and watering, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing expansion joints in reinforced cement concrete framed structure (interior column) with plain premoulded filler confirming to Indian Standard 1838 : 1961, 25 milimetre thick with 75 milimetre wide and one milimetre thick stainless steel plate finishing, excetra complete as directed. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing expansion joints in reinforced cement concrete framed structure (exterior column) with plain premoulded filler 25 milimetre thick with 75 milimetre wide and 1 milimetre thick stainless steel plate and finishing, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing expansion joints in reinforced cement concrete framed structure (at floor level) with plain premoulded filler 25 milimetre thick with 75 milimetre wide and one milimetre thick stainless steel plate and finishing, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing expansion joints in reinforced cement concrete framed structure (at terrace level) with plain premoulded filler 25 milimetre thick with 40 milimetre wide and 1 milimetre thick stainless steel plate as required bitumen poured filler and finishing excetra complete as directed. (For 4th Floor)
Providing and fixing bituminous pad 25 milimetre thick for expansion joints in retaining wall, compound wall, excetra complete. (For Ground Floor)
Providing and fixing interior wall to wall expansion joint cover model W90 for 50 mm gap size, this surface mounted aluminium cover is designed for interior application where low maintenance is desirable. This model is made using Aluminium alloy 6063 and temper T5/T6. This cover is installed using stailness steel clip in the rear which helps the movement to + 10 mm.
Providing and fixing of external wall to wall cover model ASM 200X for 50 mm gap size,this surface- mounted metal wall cover is designed for exterior applications where low maintenance or tamper-resistant applications are desired. The free-floating aluminum center plate spans the joint and slides over the surface of the wall to allow required movement.EPDM vapor barrier to protect the joint with water. This profile is extruded aluminum with ASTM B 221, Alloy 6063-T5. This profile has been tested under Architectural Testing Agency ( an Intertek Company) for the movement performance. The minimum opening of the profile is 10mm ( -40mm) and the maximum openeing of the profile is 76mm (+26mm) which is more than ±50% movement.
Providing and Fixing of external Roof cover model RJT 200 for 50 mm gap size, Aluminium roof cover comprised of extruded alumunium components, Injection molded turnbar, duroflex gaskets and EPDM vapor barrier.This profile is extruded aluminum with ASTM B 221, Alloy 6063-T5. This profile has been tested under Architectural Testing Agency ( an Intertek Company) for the movement performance. The minimum opening of the profile is 3mm ( -47mm) and the maximum openeing of the profile is 92mm (+42mm) which is more than ±50% movement.
Providing waterproofing in water closet and bath including brick bat coba in all position including providing and laying 12 milimetre bedding in cement mortar 1:3 on vergin concrete slab with waterproofing compound at the rate of 1 kilogram per bag of cement laying brick bat coba of required thickness in cement mortar 1:5 with waterproofing compound 1 kilogram per bag of cement grouting and finishing the top layer with 20 milimetre thick brick bedding in centimetre mortor 1:3 with waterproofing compound 1 kilogram per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing water proofing treatment to newly laid fully cured concrete slab of terraces by applying first coat of polymer modified semi - viscous paste prepared by mixing polymer of approved make (such as Master Seal 550 / brush bond/ Roff Supercrete / Webercrete / Monobond / Perma shield / Hypercrate / Master Crete M 81) and cement in 1:2 proportion ( one litre polymer : two kilogram cement) or Rohnex water proofing system in two coats ( one kilogram powder, 700 mililitre water and polymer jelly for first coat and one kilogram powder, 500 mililitre water and polymer jelly for second coat) to a neatly cleaned and dust free concrete surface and upto 300 milimetre over parapet wall prepared by removing loose and deposited material with brush and water, laying glass fibre mesh of 10 X 10 specification of approved make over tacky surface of first coat of polymer followed by second coat in transverse direction, laying mechanical protective cover to polymer coating treatment with brick bat coba with burnt broken brick bats laid in cement mortar 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for three days, applying cement slurry over this layer, joints of brick bats with cement mortar 1:3 admixed with approved water proofing compound and finally top finishing with average 20 milimetre thick layer of same mortar added with polypropylene fibers at 125 gram per bag of cement including finishing the surface smooth with neat cement slurry admixed with approved water proofing compond, Marking finished surface by false squares of 300 milimetre X 300 milimetre, Making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and prapet and curing and covering 10 years Guarantee against leakproofness on court fee stamp paper Rs. 100/- including ponding test excetra complete
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of reinforced cement concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / burnt brick masonry and or tying by binding wire, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and laying in situ cement concrete M-20 with tremix treatment for 100 milimetre thickness for flooring with groove cutting of 4 milimetre wide 20 milimetre deep with necessary refilling with bitumen, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and laying vitrified mirror / glossy finish tiles having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and laying in position flooring of telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on a bed of 1:4 cement mortar including float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing machine cut mirror polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone partition with rounding / moulding the edegs, excetra complete. - Both side polish (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing frame with / without ventilator of size as specified with country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 milimetre X 40 milimetre X 5 milimetre with oil painting, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings, approved face veneers 3 milimetre thick on both faces or as directed, all necessary beeds, moulding and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides and finishing with french polish, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing factory made solid core flush door shutters in double leaves 35 milimetre thick, decorative types, of exterior grade, as per detailed drawings, conforming to Indian Standard : 2202 - 1962 (Revised) including approved face veneers on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastenings, stoppers and finishing with french polishing, excetra (excluding door frame). Commercial hard wood shutter. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing the country cut teak wood second class fully glazed openable fanlight rectangular in shape as per detailed drawing excluding the frame, stainless steel fixtures and fastenings and finishing the wood work with three coats of oil painting, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing fibreglass reinforced polyster door shutter 30 milimetre thick as per Indian Standard : 14856 (2000) (reaffirmed-2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing Indian Standards Institute marked double swing flush door shutters conforming to Indian Standard : 2202 (Part I) Non-decorative type, core of block board construction with frame of first class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 milimetre thick including Indian Standards Institute marked stainless steel L-hinges with necessary screws, fittings and fixtures per leaf, stainless steel kick plates on both sides of the door of 300 milimetre height, heavy duty satin finish butt stainless steel Hinges (100 milimetre X 75 milimetre X 3 milimetre in size) 4 Nos., stainless steel finished lever handle with mortise lock 1 No., floor spring 1 No., 100 milimetre X 100 milimetre safety glass at the specified location. (For First Floor)
Supplying and fixing in position powder coated aluminium four track sliding windows with outer frame made from section of over all size 122 milimetre X 45 milimetre, bottom section with drain section track weighing 1.83 kilogram per metre and top and side section of size 122 milimetre X 31.75 milimetre weighing 1.15 kilogram per running metre with shutter sections made of 18 milimetre X 40 milimetre size having average weight of 0.6 kilogram per running metre (or as required size) with change in proportionate weight, with 6 milimetre float glass in three equal panels and aluminium coated stainless steel mosquito net in one (2/3 of opening) panel fixed with new neoprene gasket, shutters to be provided with nylon encased stainless steel rollers, necessary locks and handles complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 milimetre X 38 milimetre X 1.22 milimetre box type, 5 milimetre thick sheet glass louvers of approved quality, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing mild steel grill work for windows, ventilator, excetra 20 kilogram per square metre as per drawings including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing 50 milimetre diameter and 1.5 milimetre thick stainless steel hand railing in stainless steel 304 grade including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing 40 milimetre diameter and 1.5 milimetre thick stainless steel hand railing in stainless steel 304 grade including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates, excetra including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts, excetra of the required size on the top of the floor of the side of waiste slab with suitable arrangement as per approval of Engineer in-charge (for payment purpose, only the weight of the stainless steel members shall be considered excluding fixing accessories such as nut bolts, fasteners, excetra). 50 milimetre diameter pipe, 1.5 milimetre thickness and weight 1.92 kg/Rmt. (For Ground Floor)
For First Floor
Providing and applying two coats of wall care putty on plastered surface and ceiling and walls to prepare surface even and smooth approved make excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and applying Royale Luxury Emulsion of approved make on internal wall surface as detailed below - Scrapping for surface with emery paper and wipe clean for area. Applying wall primer with brush by adding mineral turpentine oil by 8 to 10 percent or water by 15 to 20 percent allowing to dry for 6 to 8 hours. After applying approved make acrylic wall putty with appropriate proportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean. Applying paints Royale Luxury emulsion first coat with brush water content water 40 to 45 percent or 65 to 70 percent by role. Applying paints Royale luxury emulsion second coat with brush with water content 40 to 45 percent or 65 to 70 percent by roller. (With prior approval of S.E.) (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and applying two coats Apex Ultima Puranature Anti- Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, excetra) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist.
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and laying in trenches 50 milimetre diameter unplasticized polyvinyl chloride pipe including necessary excavation, fittings, refilling trenches, excetra complete including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete.
Providing and laying concrete pipes of Indian Standard Non Pressure class of 300 milimetre diameter in proper line, level and slope including necessary collers, excavation, laying, fixing with collers in cement mortar 1:1 and refilling the trench excetra complete.
Providing and fixing 15 centimetre X 10 centimetre salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
Providing and constructing brick masonry inspection chamber 60 centimetre X 45 centimetre X 90 centimetre including 1:4:8 cement concrete foundation, 1:2:4 cement concrete channels, half round glazed stoneware pipes, brick masonary, plastering from inside and farme fixed in cement concrete Cover medium duty 140 kilogram with frame excetra complete. (using ARTIFICIAL SAND).
Providing and constructing brick masonry inspection chamber 90 centimetre X 45 centimetre X 90 centimetre including 1:4:8 cement concrete foundation, 1:2:4 cement concrete channels, half round glazed stoneware pipes, brick masonary, plastering from inside and cast iron lid cover 75 kilogram with frame fixed in cement concrete, excetra complete. (using ARTIFICIAL SAND).
Providing and fixing 450 milimetre X 550 milimetre size superior type belgium mirror with 16 milimetre diameter nickel plated towel rod, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing chromium plated towel rod 16 milimetre diameter and 75 centimetre in length including all accessories complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing 50 milimetre diameter water metre with non-return value including stainer, sockets / union nut including water metre box making locking arrangement and lock. [Without chamber].
Providing and fixing screw down for 25 milimetre diameter wheeled stop tap of brass including necessary sockets / union nut complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing screw down 32 milimetre diameter wheeled stop tap of brass including necessary sockets / union nut complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing screw down for 50 milimetre diameter wheeled stop tap of brass including necessary sockets / union nut complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing white glazed earthenware full stall type urinal with poly vinyl chloride flushing cistern of 5 litres capacity with fitting inlet pipes and stop tap brackets for fixing the cistern 32 milimetre diameter poly vinyl chloride flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap soil pipe connection upto the outside face of the wall. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing White Glazed Earthenware Squatting plate (Ladies Urinal) with polyvinyl chloride flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 milimetre diameter P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connection up to the outside face of the wall. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing push cock (self closing tap) symet type of 20 milimetre diameter including necessary socket, testing, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing White glazed with bottle trap earthenware Wash Hand Basin of 63 centimetre X 45 centimetre size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including unplasticized polyvinyl chloride waste pipe and trap upto the outside face of the wall, making good the damaged surface, testing, excetra complete.
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 milimetre X 450 milimetre size as per detailed drawing including vertical both side polished kadappah stone 25 milimetre to 30 milimetre thick supports with kadappah top 35 milimetre to 40 milimetre thick and polished granite 16 to 20 milimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 centimetre X 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite excetra complete.(Platform top size 5.00 metre X 0.60 metre and height is 0.75 metre) (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing Orissa type ivory glazed earrthenware 575 milimetre water closet pan including "S" trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall, 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing half turn 25 milimetre diameter gun metal flushing cock including all accessories, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing 40 milimetre diameter ball cock medium type with polyvinyl chloride float including sockets and necessary fittings and tested as per municipal requirements, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing 75 milimetre diameter stabilliser pipe / polyvinyl chloride soil vent / waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing 100 milimetre diameter stabilliser pipe / polyvinyl chloride soil vent / waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Provoding and fixing high density polyethylen container one piece moulded water tank made out of high density polyethylen and built corrugated inclusive of delivery upto destination housing, fixing of accessaries such as inlet, outlet, overflow pipe inclusive of all Taxes - Capacity between 1000 litres to 20000 litres. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing on walls / celling / floor, 15 milimetre diameter chlorinated polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing on walls / celling / floor, 25 milimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing 10 centimetre poly vinyl chloride nahani trap with grating, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing chromium plated angular stop cock with wall flange of approved make including necessary sockets / union nut, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing chromium plated two way bib cock of approved make including necessary sockets / union nut, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing chromium plated bib cock with wall flange of approved make including necessary sockets / union nut, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing chromium plated sink cock with raised J shaped swinging casted spout of approved make including necessary sockets / union nut, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing polyvinyl chloride Rain water pipes of 160 milimetre outer and having wall thikness of 2.2 milimetre to 2.7 milimetre confirming to Indian standared 13592-1992 including proper rain water receiving recess with polyvinyl chloride plug, bends, necessary fittings, such as offset shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimetre to 40 milimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on cement concrete or masonry blocks, including necessary scaffolding andpolyvinyl chloride maintenance for three years for any leakages or dislocations of pipes. All the fittings and additional two piece socket clips shall be got approved from engineer in charge etc. complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing european type wall hung white water closet of approved make with push valve consealed type with cover plate 32 milimetre size of approved make including soil pipe, vent pipe upto outside face of wall, 100 milimetre diameter galvanised iron plug, bend, inlet pipe all fittings, cutting and making good walls, floors, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing on walls / celling / floor 15 milimetre diameter unplasticized polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing on walls / celling / floor 20 milimetre diameter unplasticized polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing on walls / celling / floor 25 milimetre diameter unplasticized polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing on walls / celling / floor 32 milimetre diameter unplasticized polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing on walls / celling / floor 50 milimetre diameter unplasticized polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and laying in trenches 20 milimetre diameter unplasticized polyvinyl chloride pipe including necessary excavation, fittings, refilling trenches, excetra complete including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete.
Providing and fixing 15 milimetre diameter poly vinyl chloride Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing wall mixer with overhead shower,shower arm,hand shower with wall bracket having flow rate up to 12 litre per minute of Jaquar/ Cera/ Hindware/ Perryware or equivalent make including all necessary pipes,fittings etc.complete as directed by Engineer In Charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) (For 2nd Floor)
For 3rd Floor
For 4th Floor
Supply and installation of cubicles of width and depth as per Athena Lite - SS Series cubicles standard sizes 900 milimetre width X 1550 milimetre depth X 2105 milimetre height (height is including 100 milimetre gap from bottom, door width 600 milimetre specifications / site drawings). Cubicle hight to be 2105 milimetre. Made from solic grade compact high pressure laminate as per Indian Standard : 2046 and EN-438 manuafactured under high specific pressure more than 5 megapascal and temperature more than 120° Centigrade. All doors will be of single colour and made of 12 milimetre thick Merino HPL compact panel. The door will have chamfered edges. Each door will be supported by three stainless steel made hinges affixed to the pilasters. Size of panels to be as per drawing. Hardware and accessaries are H shaped (top) head frame structure made of extruded aluminium grade 6063 T5. 50 micron epoxy powder coated for surface protection. Size to be 125 milimetre X 70 milimetre X 5 milimetre thick. Corner joinery section size to be 40 milimetre X 16.5 milimetre X 1.8 milimetre thick. U-Channel wall joinery section size to be 22 milimetre X 16 milimetre X 1.6 milimetre thick. Door stopper section size to be 21 milimetre X 12.5 milimetre X 1.6 milimetre thick. Spring loaded butt hinges made from stainless steel grade 304. Surface finish to matt type. Covers to be lacqurr coated, excetra complete. (For Ground Floor)
For First Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Providing and fixing 90 centimetre X 60 centimetre granite name plate engraving 10 centimetre height letter, figures including painting the letters / figures with approved colour and shade complete.
Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns, purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required, excetra as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade, excetra complete. (For 4th Floor)
Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns, purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required, excetra as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade, excetra complete. (For Ground Floor)
Supply and Installation of DPI Flux translucent roof with standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded ultra violet protected multicell panels incorporated into a complete system. Co-extruded ultra violet protected polycarbonate panel system of minimum 18 milimetre thick of 1200 milimetre (minimum) width with angular daylighting concept. Panels shall have minimum seven layers in a truss bridge design for higher flexibility and strength. Panels with opaque and translucent clear combination as per required lux level and design requirements with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall have an additional infra red blocking features for enhance thermal comfort. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on mild steel structure (will be paid Separately) with a continuous aluminium I Beam holding the base of the standing seam along the length of the panel and fixed with purlin with self-drilling hexhead screws offering best stability with a pull-out load ofminimum 21000 N (21 kilo newton) tested as per
Providing and installing bio digester unit based on Defence Research and Development Organisation technology made of fibre reinforced plastic having composition and following technical specifications and including necessary pipe and accessories up to 3 metre length, excluding the necessary excavation for installing the bio digester. - Percentage of fibre glass (glass content in fibre glass should be minimum 30 percent) : 33.33 percent, Percentage of polyester resin : 66.67 percent, Water absorption (as per ASTM) : 0.30 percent, Flammability as per ASTM, Tensile strength : 115 MPA, Specific Gravity at 25 degree centigrade : 1.45, Izod impact strength : 65 kJ/sqm, Heat defection / distort temperature : 65 degree Centigrade, Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid polyvinyl chloride : 100 milimetre, Outlet pipe size rigid polyvinyl chloride : 80 milimetre, Gas outlet rigid polyvinyl chloride with valve : 20 milimetre, Bacteria immobilization polyvinyl chloride mattes (on all partition). With Defence Research and Development Organisation TOT licensee and latest batch certificate(month and year of supply) and capacity as below - Up to 400 user - size 5.0 metre X 2.0 metre X 1.5 metre, Capacity of biodgester : 15000 liters, Area of top, bottom and side walls : 41.0 sqm, Area of partition walls : 12.0 sqm, Total weight of fibreglass reinforced polyster : 678.80 kg, Bacteria inoculums quantity : 5200 litres, Minimum thickness of side walls / top and bottom : 8 milimetre, Number of inside partitions : 4, Minimum thickness of partition wall : 4 milimetre.
Providing and erecting 2mm thick Aluminium Laser cut façade screens, Pattern cut as per design, Powdercoated all sides, Tray bend all sides each panel - 25 mm
Digging borewell with transportation in soil/ earth/ SM of 200 mm dia. and 150 mm dia. in hard rock by wet drilling
Providing and fixing PVC casing pipe of 180 mm dia. of 6 kg/cm^2(IS 4185-1988)
Providing and fixing Cap for 180 mm dia. PVC pipe
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed. By Mechanical Means.
Excavation for roadway in hard murum and boulder including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed.
Excavation for roadway in soft rock, including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading or stacking as directed.
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing off unsuitable or excess stuff as directed all sorts of soils.
Excavation for catch / side water gutter in hard murum and boulder strata to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed.
Watering and compacting of embankment formed of materials obtained from the road cutting, within a lead of 50 metre to not less than 97 percent of Standard Proctor density after laying them in layers of 20 centimetre to 30 centimetre. With vibratory roller
Providing soling using 80 milimetre size trap metal in 15 centimetre layer including filling voids with crushed sand / grit, ramming, watering, excetra complete.
Construction of granular sub-base by providing close graded material, mixing in a mechanical mix plant at optimum moisture content, carraige of mixed material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401. - Plant Mix Method and grading - I material.
Construction of dry lean cement concrete sub-base over a prepared sub-grade with coarse and fine aggregate (V.S.I. grade finely washed crushed sand) conforming to Indian Standard : 383, the size of coarse aggregate not exceeding 25 milimetre, cement content not to be less than 150 kilogram per cubic metre, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant / weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor / by suitable means as approved by Engineer in-charge, compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required, excetra complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.
Providing and laying in situ M-30 grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate (V.S.I. grade finely washed crushed sand) conforming to Indian Standard : 383, using fine and coarse aggregates combined gradation as per Table 600-3 of Ministry of Road Transport and Highways specification 2013, mixed in a batching and mixing plant / non tilting mixer and weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer in-charge and curing by curing compound / by providing cement vata in cement mortar 1:8 at 0.6 metre X 0.6 metre center to centre, admeasuring 80 milimetre at bottom and 40 milimetre at top with depth of 75 milimetre and maintaining the same throughout curing period or by any other method approved by Engineer in-charge, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled / concrete Batch mix plant (Pan mixer) excetra complete.
Providing and laying cast in situ / Ready Mix cement conrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed, including steel centering, formwork, cover blocks,aying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled / concrete Batch mix plant (Pan mixer) excetra complete.with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled / concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks,laying / pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).
For First Floor
Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water, striking joints on unexposed faces and watering, excetra complete. (using ARTIFICIAL SAND).
Providing and laying cast in situ / Ready Mix cement concrete in M-15 of trap / granite / quartzite / gneiss metal for coping to plinth or parapet moulded or chamfered as per drawing or as directed including steel centering, plywood / steel formwork, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing, excetra complete. The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin, excetra complete. (Wooden centering will not be allowed.) With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).
Providing flush grooved pointing with cement mortar 1:3 for stone masonry work including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
Providing and fabricting structural steel work in rolled sections like joists, channels, angles, tees, excetra as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted / welded connections without connecting plates, braces, excetra and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, excetra complete. (For Ground Floor)
Providing and fixing of colour coated zincalume (R) AZ 150 (Minimum 150 grams per square metre total on each sides) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 milimetre base metal thickness (BMT) (0.5 milimetre TCT), Hi-strength steel with minium 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55 percent aluminium, 43.4 percent zinc, 1.6 percent silicon) with COLORBOND (R) steel quality super durable polyster paint coat (with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nominal 950-1050 milimetre effective cover width and nominal 25-30 milimetre deep ribs with subtle square fluting in the five pan at nominal 180-250 milimetre center to centre. The end rib shall be designed for anti capilary groove and return leg. The feed material should have coil manufacturer's product details marked at regular interval. Including fasteners with minium fatened with minium 25 um zinc-tin alloy coated, hex head, self-drilling screw, excetra complete. (Weight of profile 4.52 kilogram per square metre). (For Ground Floor)
Providing and fixing of colour coated zincalume (R) AZ 150 (Minimum 150 grams per square metre total on each sides) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 milimetre base metal thickness (BMT) (0.5 milimetre TCT), Hi-strength steel with minium 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55 percent aluminium, 43.4 percent zinc, 1.6 percent silicon) with COLORBOND (R) steel quality super durable polyster paint coat (with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nominal 950-1050 milimetre effective cover width and nominal 25-30 milimetre deep ribs with subtle square fluting in the five pan at nominal 180-250 milimetre center to centre. The end rib shall be designed for anti capilary groove and return leg. The feed material should have coil manufacturer's product details marked at regular interval. Including fasteners with minium fatened with minium 25 um zinc-tin alloy coated, hex head, self-drilling screw, excetra complete. (Weight of profile 4.52 kilogram per square metre). - 301 milimetre to 600 milimetre girth (surface width) (For Ground Floor)
Royalty charges for various building construction bonafied materials which are used for government bonafied works and for which Royalty charges are to be paid by the contractor. (This Item is to be paid to the contractor only after he pays the Royalty amount to Revenue department and produces the required voucher.)
Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune. Liquid Limit & Plastic Limit for Plinth Filling
Standard Consistancy, Fineness, Specific Gravity, Setting Time (Initial and Final), Compressive Strength, Soundness Test for Cement
Fineness Modulus (Sieve Analysis), Silt and Clay Content Test for Artificial Sand
Compressive Strength of Cement Concrete Cube
Sieve Analysis Test for Metal below 40 milimetre
Water Absorption, Specific Gravity, Impact Value, Crushing Value Test for Metal below 40 milimetre
Concrete Mix Design (with all tests on basic materials) for Grade M-40
Concrete Mix Design (with all tests on basic materials) for Grade M-20
Concrete Mix Design (with all tests on basic materials) for Grade M-25
Tensile Strength, Percent Elongation, Yield Stress, Weight per Metre, Bend / Rebend Test, Proof Stress (Steel Bar upto 16 milimetre)
Tensile Strength, Percent Elongation, Yield Stress, Weight per Metre, Bend / Rebend Test, Proof Stress (Steel Bar above 16 milimetre)
Compressive Strength of Cement Mortar
Water Absorption, Compressive Strength, Efflorescence Test for Fly Ash Bricks
Water Absorption, Modulus of Rupture Test for Ceramic / Vitrified Tiles
Density, Moisture Content for Wood
Thickness, Mass per Running Metre of Aluminium Section
Water Absorption, Compressive Strength, Efflorescence Test for Burnt Bricks
Compaction Test (Proctor Density) for Earth Work
Crushing Value / Compressive Strength, Water Absorption, Specific Gravity Test for Stone / Rubble
Fineness Modulus (Sieve Analysis), Silt and Clay Content Test for Sand
Granular Sub-Base Mix Design
Flekiness Index / Elongation Index Test for Metal below 40 milimetre
Concrete Mix Design (with all tests on basic materials) for Grade M-30
Supplying, installing, testing and commissioning 11 kV 630A, indoor type ring main unit with 1 VCB & 2 LBS with internal arc compliance complete erected on provided CC foundation/MS channels/trench, etc., as per specification no SW-HTS / RMU
Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 630kVA, Mineral oil immersed and naturally cooled Intdoor type, Copper wound Non-sealed transformer delta/star connected additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%, having 7 number of tap positions , with standard accessories complete with test certificate with losses below 1860 Watts at 50% load, 5300 Watts at 100% load as per IS:1180 (part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TRNSL. 10-1-10 NOTE 1 1) For indoor type transformer add Rs. 18000/- in rate of transformer.
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 200 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 34.40 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB(A) at 1.0 m, provided with first filling of oil, diesel not less than 300 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 200 kVA up to 250 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT NOTE 2 2) For round wire armouring increase rate For 11 kV (E) by 28%
Providing and erecting Heat shrinkable indoor termination kit for 11 kV (UE)/ 22 kV ( E ) XLPE HT cable 3x95 sq. mm. with necessary material as per specification no. CB-JT/HT
Supplying and erecting 40 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating , APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC
Supplying and erecting 75 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating , APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)
Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544 duly tested, with necessary test certificate from manufacturer.
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 having 2.5 mm thickness up to 11 kV
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working upto 22 kV supply complete
Supply, Installation, Testing and commissioning of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. Specification no. EA-MOBI
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP.
Supplying and erecting G.I. strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joint required. as per specification No (EA-EP).
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking DPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuitbreaking capacity (Icn) 10kA in provided distribution board as per specificationno. SW-SWR/MCB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB),SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) asper specification no. SW-SWR/MCBDB
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying and erecting blanking plate of suitable size on MCBDB.
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & commissioning 4 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying and erecting quartz electronic time switch having 24 hour dial to work on 250 V 50 cycle AC having built in rechargeable nickel cadmium batteries to run the time switch on failure of supply having switch contact rating up to 16A to use independently or in conjunction with contactor.
Supplying and erecting four pole power contactor 430 V, 16 A for time switch complete erected on provided wooden block/ box, with necessary materials.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (NOTE 3)
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG?PW/CW
Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG?PW/CW
Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW
Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty.
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
upplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% without IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF NOTE
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 75 mm height complete with necessary coupler plates & hardware. (28Mtr X 3 Off/Fl X 3 Fl + 30X3 GF + 60 +40 EL Vertical + 40 LV Vertical + 28X3 off X3 Fl = 1194
Supplying and erecting PVC slotted box trunking of size 100x100 mm. with accessories on wall/ceiling as per specification No: WG-MA/SLBOX
Supplying, erecting, testing and commissioning of 6kVA capacity online pure sine wave with backup time of 0.5 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS (7 Off X 3 Fl = 21 + 1 Audi + 1 Common)
Supplying and erecting 12V/17Ah -18Ah SMF battery with battery terminal wire, duly charged with 12 months warranty complete
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority
Supplying and erecting integrated LED Bollard Cylindrical/Cubical shaped 800mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of Min. 800 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 25,000 Hrs. at L50B50, including driver complete with 2 Year warranty as per specification No FG-ODF/FLS2.
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supply, Installation, testing and commissioning of cubical type MV Panel conform to IEC:61439-I as per technical specifications,single line diagram & approval of Drawings prior to manufacturing, packed in wooden crates with PVC sheets inner packing, transport to site, compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. erected in 14 gauge CRCA sheet and surface treated with phosphating seven tank process and duly powder coated with MSEDCl approved color, feeder piller should be with supporting angles, self-locks, gasket and slanting top to be erected on provided foundation Panel Details :- Name - MAIN LT FEEDER PILLAR Duty -Duty: Indoor Type (IP 42) Busbar - 1000A TPN Al Busbar 1000A FP ACB MDO Outgoings - 400A HRC FUSE - 12 NOS, 315A HRC FUSE - 3 NOS 200A HRC FUSE - 3 NOS 100A HRC FUSE - 3 NOS INDICATOR LAMPS, as per schematic
Supply, Installation, testing and commissioning of cubical type MV Panel conform to IEC:61439-I as per technical specifications,single line diagram & approval of Drawings prior to manufacturing, packed in wooden crates with PVC sheets inner packing, transport to site, compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. erected in 14 gauge CRCA sheet and surface treated with phosphating seven tank process and duly powder coated with MSEDCl approved color, feeder piller should be with supporting angles, self-locks, gasket and slanting top to be erected on provided foundation Panel Details :- Name - DG PANEL Duty -Duty: Indoor Type (IP 42) Incomer-1 Nos of 315 FP MCCB, Busbar - 400A TPN Al Busbar Outgoings - 315A FP MCCB - 2 NOS, 200A FP MCCB - 1 NOS 100A FP MCCB - 1 NOS as per schematic
Supply, Installation, testing and commissioning of cubical type MV Panel conform to IEC:61439-I as per technical specifications,single line diagram & approval of Drawings prior to manufacturing, packed in wooden crates with PVC sheets inner packing, transport to site, compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. erected in 14 gauge CRCA sheet and surface treated with phosphating seven tank process and duly powder coated with MSEDCl approved color, feeder piller should be with supporting angles, self-locks, gasket and slanting top to be erected on provided foundation Panel Details :- Name - Meter Panel 1 Duty -Duty: Indoor Type (IP 42) Incomer-1 Nos of 400 FP MCCB, Busbar - 400A TPN Al Busbar Outgoings - 40-63A FP MCB - 16 NOS, 40A DP MCB - 4 NOS 3PH TRIVECTOR METER - 13 NOS 1PH METER - 4 NOS as per schematic
Supply, Installation, testing and commissioning of cubical type MV Panel conform to IEC:61439-I as per technical specifications,single line diagram & approval of Drawings prior to manufacturing, packed in wooden crates with PVC sheets inner packing, transport to site, compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. erected in 14 gauge CRCA sheet and surface treated with phosphating seven tank process and duly powder coated with MSEDCl approved color, feeder piller should be with supporting angles, self-locks, gasket and slanting top to be erected on provided foundation Panel Details :- Name - Mater Panel 2 Incomer-1 Nos of 315 FP MCCB, Busbar - 400A TPN Al Busbar Outgoings - 40A FP MCB - 10 NOS, 40A DP MCCB - 5 NOS 3PH TRIVECTOR METER - 10 NOS 1PH METER - 3 NOS
Supply, Installation, testing and commissioning of cubical type MV Panel conform to IEC:61439-I as per technical specifications,single line diagram & approval of Drawings prior to manufacturing, packed in wooden crates with PVC sheets inner packing, transport to site, compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. erected in 14 gauge CRCA sheet and surface treated with phosphating seven tank process and duly powder coated with MSEDCl approved color, feeder piller should be with supporting angles, self-locks, gasket and slanting top to be erected on provided foundation Panel Details :- Name - Common Panel 1 Incomer-1 Nos of 400 FP MCCB, Busbar - 400A TPN Al Busbar Outgoings - 400A FP ATS WITH MCCB, MSEDCL LT CT METER 200A FP MCCB - 2 NOS 100A FP MCCB - 2 NOS 40a FP MCB - 24 nOS 32A FP MCB - 20 NOS
Supply, Installation, testing and commissioning of cubical type MV Panel conform to IEC:61439-I as per technical specifications,single line diagram & approval of Drawings prior to manufacturing, packed in wooden crates with PVC sheets inner packing, transport to site, compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. erected in 14 gauge CRCA sheet and surface treated with phosphating seven tank process and duly powder coated with MSEDCl approved color, feeder piller should be with supporting angles, self-locks, gasket and slanting top to be erected on provided foundation Panel Details :- Name - Common Panel 2 Duty -Duty: Indoor Type (IP 42) INCOMMER 200A FP MCCB WITH MSEDCL CT METER Busbar - 200A TPN Al Busbar Outgoings - 100A FP MCCB - 4 NOS 63A FP MCB - 1 NOS
Supply, Installation, testing and commissioning of cubical type MV Panel conform to IEC:61439-I as per technical specifications,single line diagram & approval of Drawings prior to manufacturing, packed in wooden crates with PVC sheets inner packing, transport to site, compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. erected in 14 gauge CRCA sheet and surface treated with phosphating seven tank process and duly powder coated with MSEDCl approved color, feeder piller should be with supporting angles, self-locks, gasket and slanting top to be erected on provided foundation Panel Details :- Name - Lift panel Duty -Duty: Indoor Type (IP 42) Incomer - 100A FP MCCB, Busbar - 100A TPN Al Busbar WITH ATS Outgoings - 40A FP MCB - 5 NOS 16A DP MCB - 5 NOS as per schematic
Supply, Installation, testing and commissioning of cubical type MV Panel conform to IEC:61439-I as per technical specifications,single line diagram & approval of Drawings prior to manufacturing, packed in wooden crates with PVC sheets inner packing, transport to site, compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. erected in 14 gauge CRCA sheet and surface treated with phosphating seven tank process and duly powder coated with MSEDCl approved color, feeder piller should be with supporting angles, self-locks, gasket and slanting top to be erected on provided foundation Panel Details :- Name - Emergency Lighting Duty -Duty: Indoor Type (IP 42) Incomer - 40A DP MCB Busbar - 100A TPN Al Busbar 1000A FP ACB MDO Outgoings - 25A DP MCB - 10 NOS
Supply, Installation, testing and commissioning of cubical type MV Panel conform to IEC:61439-I as per technical specifications,single line diagram & approval of Drawings prior to manufacturing, packed in wooden crates with PVC sheets inner packing, transport to site, compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. erected in 14 gauge CRCA sheet and surface treated with phosphating seven tank process and duly powder coated with MSEDCl approved color, feeder piller should be with supporting angles, self-locks, gasket and slanting top to be erected on provided foundation Panel Details :- Name - AUDITORIUM Duty -Duty: Indoor Type (IP 42) Incomer - 100A FP MCB Busbar - 100A TPN Al Busbar 1000A FP ACB MDO Outgoings - 63A FP MCB - 6 NOS 16A DP MCB - 2 NOS 40A DP MCB - 2 NOS
SITC of Electric Traction Passenger Lift with · Rated capacity :- 10 Passenger/680Kg · Floors :- P1+P2+G+2 floor (5 Stops/5 Landings) · Travel :- 22.2 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 900 mm wide x 2000 mm high · Clear Car size of 1300 mm wide x1350 mm deep x 2250mm high · Lift shaft available having clear size of2000mm wide x 2000mm deep, pith epth-1500mm, Over height-4500mm. Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.· ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit /trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. (MR 1+each floor 5)
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected.
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW
Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Point wiring (1.7.19) Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting CRCA powder coated corridor/ passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
Providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm.
Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 300 mm as per specification no FG-FAS/MSC
Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation.
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/ compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 4 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying & erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE
Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI
Supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws complete.
Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN - 10025 S355/E350 & 3mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum with assembly 250 kg, 5x2.5 Sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete as per specification no. OH?PL/HM (excluding luminaries)
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 32A TPN MCB incomer, 24hr astronomical time switch with minimum 5 years battery backup, IP 54 and IK10 protection, 25 A TP contactor for automatic switching of luminaires, 2 no. 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box with supporting angles, self lock, gasket and slanting top erected on CC foundation complete.
Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast).
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multistra nded copper Industrial cable for voltage grade up to 1.1 kV (45 Poles x 7 mtr = 315 m ) ( 2 Highmast 14 mtr x 12 = 168 Total --483 )
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, installation, testing and commissioning of Main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 55kW or of suitable kW capacity for manual / automatic operation and consisting of following (a)Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b)Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c)M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d)Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP
Supplying, installation, testing and commissioning of jockey fire pump (JP)suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 9.3 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plasteredwith anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP
Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d)Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP
Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP
Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications the capacity of electric motor driven pump are as follows a. Main fire pump (MFP) having capacity of 22kW 1no (1 working) b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears: 1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating. 2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU's, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating. Add on For addition of capacity of main electric motor driven fire pump MFP (1 working) for hydrant system is more than 22kW, add as follows in the basic cost of Item no 13-5-1 towards increased capacity switchgears and motor starters for main & jockey pumps along with necessary accessories for main & jockey fire pumps MFP (1working), JP (1working + 1standby, alternate run per start in auto mode)
For main electric motor driven fire hydrant system pump of 55kW capacity & relevant capacity jockey pump add Rs….
Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.C. Submersible/centrifugal pump set up to 7.5 HP - 10 H.P. consisting of DOL starter having relay range 28-42 AMP,S.P.P., Combined ammeter/voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc.
Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP
Providing coating of bitumen paint & 4mm thick wrapping for underground 100 mm ring main of fire fighting system.
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
Excavating hard murum / stone metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site as required complete.
Supplying and erecting 75/80 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 75/80 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV
Supplying and erecting 150 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV
Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 75/80 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
Supplying and erecting 50 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
Supplying and erecting gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and erecting ISI mark GI pipe 32 mm. dia ‘C” class at position with accessories complete. Specification no. CW-PLB/GP.
Supplying and erecting ISI mark GI pipe 40 mm. dia ‘C” class at position with accessories complete. Specification no. CW-PLB/GP.
Supplying and installing one piece moulded HDPE / fibre water tank for negative suction only, having capacity 1000 litres fitted with necessary accessories complete as per specification no. FF-FFA/PT
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting gun metal branch pipe of 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specification no. FF?FFA/NZ
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FF-FA/FMC
Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no.FF-FFA/ACT
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
13-8-14 Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP
Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8" x 6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
Supplying, erecting, testing and commissioning vane type water flow detector 100 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes.
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR.
Supplying, installing, testing, and commissioning standard response Sidewall sprinkler (Standard coverage) quartzite bulb type with 15mm screwed end connection of 68 deg. C.tempersture rating K-80 and orifice shall not be less than 6mm sprinklers shall be UL listed approved with chrome finished. complete all the work up to the satisfaction of the Engineer in charge.
Providing and fixing 150 mm dia installation valve with Hydraulic trim type automatic alarm to be connected with control valve drain and test valve as per manufacturer's recommendations . with accessories like water motor gong bell, Test & drain valve , Flow switch etc UL listed etc complete to satisfaction of Architect/ PM
Supplying, installing, testing, and commissioning of portable fire extinguishers of ABC dry powder stored pressure type fire extinguishers of 6 Kgs.capacity Complete with standard discharge valve with tube, CI bracket for wall mounting etc. complete as per confirming to IS : 15683 complete all the work up to the satisfaction of the Engineer in charge.
Providing and fixing in position statutory Signage's made out of 3mm thick opaque PVC foam board, machine cut, non reflective, auto glow (type & Make), with silicon adhesive for safe evacuation of occupants in case of emergency. Sign indicators should be provided at prominent places as per Fire Provisional NOC (As per - IS-9457, IS-12349, IS-12407). complete all the work up to the satisfaction of the Engineer in charge.
Providing, laying, testing & commissioning of 80mm dia resilient rubber neoprene lined single arch Vibration eliminators (Expansion bellows) suitable for Design Pressure 16 kg/sq cm and test pressure 24 kg/sq cm. complete all the work up to the satisfaction of the Engineer in charge.
Providing, laying, testing & commissioning of 150mm dia resilient rubber neoprene lined single arch Vibration eliminators (Expansion bellows) suitable for Design Pressure 16 kg/sq cm and test pressure 24 kg/sq cm. complete all the work up to the satisfaction of the Engineer in charge.
Supplying, installation, testing, and commissioning 50MM Test and drain valve with K factor 5.6 unless otherwise mentioned in the drawings; made of brass in following sizes, with with unions etc. complete. The installation must be carried out as per the standard procedure as directed by the EIC.
Providing and fixing 25 mm dia Inspection & Testing Assembly with 25mm gunmetal ball valve, gun metal sight glass bypass valve & connected to drain line etc complete as per drawing.
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.
Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5 - 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI
Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, ,IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP.
Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP
Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF?AFAS/SD .
Supplying, installing, testing and commissioning of intelligent addressable thermal / heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
Supplying, installing, testing and commissioning of intelligent addressable thermal/ heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from - 20°C to 38 °C for fixed-heat and rate-of-rise type detectors whereas 0°C to 90°C for high heat type detectors, in built isolation mode, suitable for industrial/ kitchen/ boiler room etc. with 3 years equipment replacement warranty, IS : 2175-1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
Supplying, installing, testing and commissioning of digital linear heat detection cable addressable through monitor module with temperature ratings such as 60°-70°C, conforming to IS 2189: 2008, EN 54 or UL listed FF-AFAS/LHDC.
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM
Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON.
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK
Supplying, erecting, testing and commissioning of 1.5 sq. mm speaker wire complete.
Supply, installation, testing & commissioning of 6 Watt Cone type Ceiling Mounted metal grill Speakers with line matching transformer, Power tapping: 1.5W/3W/6W, Frequency response: 100-20000 Hz. SPL (1W 1m) 92 dB, including screw clamp mounting with required accessories. (Colour - White)
Supply, Installation, testing and commissioning of 6 Watt Box type Wall / Surface Mount Speaker with line matching transformer, Power tapping: 1.5W/3W/6W, ABS or metal body, Frequency response: 100-20000 Hz. SPL (1W 1m) 92 dB, including required mounting accessories.
Supply, Installation, testing and commissioning of 10 Watt column/wall mount Projector Speaker (uni directional) with line matching transformer, Power tapping: 5W/10W, fire protected ABS or Metal cabinet, includes a steel U-bracket, with adjustable inclination and easy installation with required accessories.
Supply, installation, testing & commissioning of 6 Zone Voice Alarm PA Controller with built in audio message generator (multi message), 6 Zone 70/100V live outputs for Speaker circuit, Fireman Microphone, Pre-recorded evacuation messages, Should be able to send 2 different pre-recorded messages simultaneously (message should be in 2 languages English & Hindi), Phased evacuation, 6 supervised input contact relays for integration with Fire Alarm Control Panel, Up to 6 call stations can be connected together with controller. The controller should integrates multiple functions such as audio storage, playback, zone control, audio monitoring, scheduled broadcast and fault diagnosis, audio playing, zone control, fault monitoring, log recording, volume control and amplifier switchover etc. complete with cords, connectors & required accessories.
Supply, installation, testing & commissioning of 480 Watt, high efficiency Power amplifier, 70/100V loudspeaker output voltages, RMS output power limiter, high temperature, DC, short circuit, mains undervoltage protection, DC supply undervoltage protection, inrush current limiter with cords, connectors, power supply & required accessories.
Supply, installation, testing & commissioning of 240 Watt, high efficiency Power amplifier, 70/100V loudspeaker output voltages, RMS output power limiter, high temperature, DC, short circuit, mains undervoltage protection, DC supply undervoltage protection, inrush current limiter with cords, connectors, power supply & required accessories.
S.S.SATHE
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid