Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹30.1 LAdmitted-Finance 102 STREET NO 10 1 SHAKTI NAGAR DERABASSI PB | -2.27% | ₹30.1 L | L1 | Admitted-Finance |
| 2 | L2₹32.0 LAdmitted-Finance 195 FLAT NO 5068 2ND FLOOR MODERN HOUSING COMPLEX MANIMAJRA CHANDIGARH | CHANDIGARH | CHANDIGARH | CHANDIGARH | +4.00% | ₹32.0 L | L2 | Admitted-Finance |
Tender Value
₹30.8 L
EMD Value
₹61,620
Closing Date
2 Mar 2026, 3:00 pmClosed
Executive Engineer SWM MC Chd
Room No. 612 6th floor MC Building Sector 17 Chandigarh
Providing and Laying of Storm water drainage system in Shastri Market and behind Sun Beam Hotel Sector 22 Chandigarh.
2026_MCC_90578_2
MCC/EE/SWM/2026/5
Open Tender
Civil Works
120 days
Chandigarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,000
₹61,620
3 Mar 2026
20 Feb 2026
2 Mar 2026
20 Feb 2026
2 Mar 2026
20 Feb 2026
SUB HEAD NO. 1 Shastri Market, Sector- 22, Chandigarh
Extra cutting through metalled road and their foundation including sorting screening and stacking at the site complete in all respects. (NSI)
Earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10sqm or plan) including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. All kinds of soil. (DSR No. 2.8.1)
Carriage of material by mechanical transport including loading, unloading and stacking Earth upto 2 Km. (DSR No. 1.1.2)
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : (DSR No. 19.6)
For 300mm RCC Pipe (DSR No. 19.6.4)
For 400mm RCC Pipe (NSI based on DSR No. 19.6)
For 450mm RCC Pipe (DSR No. 19.6.5)
For 600mm RCC Pipe (DSR No. 19.6.7)
Providing Laying In Position Cement Concrete Of specified Grade Excluding Cast Of Centering And Shuttering – All work up to plinth level: 1:5:10 (1 cement : 5 manufactured sand derived from recycled concrete Aggregate (RCA): 10 graded stone aggregate 40 mm nominal size Recycled aggregate (RA) (DSR No. 4.1.10 A)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR No. 6.1.1)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand i/c manufactured sand derived from Recycled concrete Aggregate (RCA) upto 25% : 4 graded stone aggregate 40 mm nominal size Recycled concrete Aggregate (RCA) upto 25%). (NSI based on DSR No. 4.1.4)
12 mm cement plaster finished with a floating coat of neat cement of mix 1:4 (1cement: 4 fine sand) (DSR No. 13.7.2)
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. (DSR No. 5.9.3)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR No. 5.22.6)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (DSR No. 5.3)
Making connection of drain or storm line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete For pipes 450 to 600 mm diameter (NSI based on DSR No. 19.21)
Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality: Circular shape 560 mm internal diameter. (DSR No. 19.19.3.1)
Providing orange colour safely foot rest of minimum 6mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmX25mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30X20X15 cm cement concrete block 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. (DSR No. 19.16)
Supplying and filling sand (recycled sand) under road crossing including carriage etc., complete in all respects to the entire satisfaction of the EIC. (NSI based on DSR No. 2.27)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (DSR No. 2.25)
Providing and Fixing of precast RCC M-20 HD Road Gully cover and frames in 1:2 Cement Sand Mortar on the top of brick masonary chamber complete in all respects to the entire satisfaction of EIC. (Size of cover 690 x 537 x 80mm and of frame is 810 x 657 x 130mm). (NSI)
SUB HEAD NO. 2 Behind Sun Beam Hotel, Sector 22, Chandigarh
Extra cutting through metalled road and their foundation including sorting screening ans stacking at the site complete in all respects. (NSI)
Earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1:5 m in width or 10sqm or plan) including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. All kinds of soil. (DSR No. 2.8.1)
Carriage of material by mechanical transport including loading, unloading and stacking Earth upto 2 Km. (DSR No. 1.1.2)
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : (DSR No. 19.6)
For 300mm RCC Pipe (DSR No. 19.6.4)
For 450mm RCC Pipe (DSR No. 19.6.5)
Providing Laying In Position Cement Concrete Of specified Grade Excluding Cast Of Centering And Shuttering – All work up to plinth level: 1:5:10 (1 cement : 5 manufactured sand derived from recycled concrete Aggregate (RCA): 10 graded stone aggregate 40 mm nominal size Recycled aggregate (RA) (DSR No. 4.1.10 A)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR No. 6.1.1)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand i/c manufactured sand derived from Recycled concrete Aggregate (RCA) upto 25% : 4 graded stone aggregate 40 mm nominal size Recycled concrete Aggregate (RCA) upto 25%). (NSI based on DSR No. 4.1.4)
12 mm cement plaster finished with a floating coat of neat cement of mix 1:4 (1cement: 4 fine sand) (DSR No. 13.7.2)
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. (DSR No. 5.9.3)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR No. 5.22.6)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (DSR No. 5.3)
Making connection of drain or storm line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete For pipes 450 to 600 mm diameter (NSI based on DSR No. 19.21)
Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality: Circular shape 560 mm internal diameter. (DSR No. 19.19.3.1)
Providing orange colour safely foot rest of minimum 6mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmX25mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30X20X15 cm cement concrete block 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. (DSR No. 19.16)
Supplying and filling sand (recycled sand) under road crossing including carriage etc., complete in all respects to the entire satisfaction of the EIC. (NSI based on DSR No. 2.27)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (DSR No. 2.25)
Providing and Fixing of precast RCC M-20 HD Road Gully cover and frames in 1:2 Cement Sand Mortar on the top of brick masonary chamber complete in all respects to the entire satisfaction of EIC. (Size of cover 690 x 537 x 80mm and of frame is 810 x 657 x 130mm). (NSI)
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 15.92 MB
BOQ_111032.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid