Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.0 LAccepted-AOC 9 SARAT BOSE ROAD OPP KALIDHAR TRANSFORMER HAKIMPARA SILIGURI 734 001 | JALPAIGURI | WEST BENGAL | 734001 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹47.2 L+₹1.1 L (2.46%)Rejected-Finance 75 VIDYAPITH ROAD DESHBANDHU PARA SOUTH PO SILIGURI TOWN DIST DARJEELING WB PIN 734004 WB | JALPAIGURI | WEST BENGAL | 734004 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹47.2 L+₹1.1 L (2.48%)Rejected-Finance VILL DANGAPARA NEAR SAHID BEDI PO RAHARAH PS KHARDAH KOLKATA 700 118 | 24 PARAGANAS NORTH | WEST BENGAL | 700118 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹47.3 L+₹1.3 L (2.76%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹47.5 L+₹1.4 L (3.12%)Rejected-Finance HAKIMPARA NEAR PAKURTALA MORE SILIGURI 734 001 | DARJEELING | WEST BENGAL | 734001 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹42.9 L
EMD Value
₹85,880
Closing Date
4 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Sukna
Garrison Engineer Sukna, Post-Simulbari, Dist.-Darjeeling, WB-734009
PROVN OF GD ROOM AND TOILET AT MT GATE ASC BN (MT) IN SUKNA MIL STN
2023_MES_622826_1
GE Sukna/8581
Open Tender
Civil Works
Works
270 days
Sukna
All as per tender documents
8 documents required · 8 mandatory
₹500
GE Sukna
₹85,880
Yes
5 Dec 2023
12 Oct 2023
6 Nov 2023
12 Oct 2023
4 Nov 2023
28 Oct 2023
13 Oct 2023 - 4 Nov 2023
Amount
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and directed.
Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in Soft/ Loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50m & making good surface complete all as specified and directed.
Surface dressing not exc. 15 cm deep as in soft / loose soil complete all as specified and directed.
M & L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
Removing Excavated soils not exc 50 M and depositing where directed at a level not exc1.5 M above the starting point complete all as specified and directed.
M & L for Hardcore of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
M&L for Plain Cement Concrete Type C2 1:3:6 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
M&L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
M & L for providing reinforced cement concrete 1:2:4, Type B-1, Nominal Mix using 20 mm graded stone aggregate as in foundation including rafts, footing, foundation beams, plinth beams, bases for columns, basement slabs, under-reamed piles and mass concrete complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately under respective item)
M&L for Reinforced Cement Concrete Type B-1 1:2:4 (using 20 mm graded stone aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, deck slabs and in shelves and the like complete all as specified and directed.
M & L for providing Reinforced cement concrete (1:2:4) type B-1 Nominal Mix using 20 mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 m span and like complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately under respective item)
M & L for providing reinforced cement concrete 1:2:4, Type B-1, Nominal Mix using 20 mm graded stone aggregate as in columns, pillars, piers, posps and struts complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately under respective item)
Supply only integral water proofing compound complete all as specified.
M & L for brick work with sub class ‘B’ old size bricks straight or curved on plan n.exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for Brick work with sub-class `B' bricks, straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and directed.
M & L for use and waste of formwork to sides of concrete foundation, footing, bases of columns, raft & raft beams, sides and soffits (if any) of foundation and plinth beams; and similar works; in rough finished flat surface of concrete complete all as specified and directed.
M&L for rough finished flat form work to soffits of suspended slabs such as roof slabs, floor slabs and similar work not exc. 200 mm thick (horizontal or sloping) work as rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in rough finished flat surface of concrete complete all as specified and directed.
M & L for use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions in rough finished surface of concrete complete all as specified and directed.
Taking down chowkhats or frames area not exc. 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 4.00 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail,lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of wire gauze in lieu of plain colour PVC sheet. The wire gauze shall be wrapped on an additional square 8mm MS Solid tube and this tube shall be welded to MS tubes. The wire gauge shall be stretched to tighten firmly, suppling & fixing in the framecomplete all as specified and directed.
S & F factory made Solid PVC door frame of size 50 mm X 47 mm made out of 5 mm plain coloured PVC sheet reinforced with mild steel square tube as per specification and drawing given on MES schedule Part – II (2010) complete all as specified and directed.
S&F 30mm thick flush shutters, solid core construction, with MDF board and both face is covered with decorative face veneer with 6mm thick teak wood lipping/frame to match all as specified and directed
S&F 150mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
S & F of 300 mm long (Length of bolt) aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolt of extruded sections or cast aluminium alloy complete all as specified and directed.
S & F 125 mm long medium weight, cold rolled mild steel Butt hinges with screws complete all as specified and directed.
S & F 100 mm long medium weight, cold rolled mild steel Butt hinges with screws complete all as specified and directed.
S & F 300 mm long ordinary rat tail pattern springs including roller and roller plate complete all as specified and directed.
S&F in repair 140 mm floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
S&F 150 mm Aluminium handles cast type, anodised and fixed complete all as specified and directed.
S&F 125 mm Aluminium handles cast type, anodised and fixed complete all as specified and directed.
S&F in repairs 20 mm dia harrison rail, mild steel, chromium plated with & includig suitable fixing CP brackets, stops, rollers etc. complete all as specified and directed.
S&F towel rail 20 mm dia & 600 mm long D type of brass chromium plated fixed with and including chromium plated brass screws and wooden / plastic cleat complete all as specified and directed.
S & F Mild steel work in framed work such as grills, gratings,framed guard bars, ladders etc., with ends of bars shouldered and/ or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S & F of mild steel screw bolts (machine made) with hexagonal or square head at one end and screwed the other or screwed both ends, each screwed ends to be fitted with washer and one hexagonal or square nut, exc. 10 cm and not exc. 15 cm long and 11 to 15 mm dia of shank complete all as specified and directed.
S&F Mild steel screw bolts diameter of neck 16 to 20 mm (machine made) with hexoganal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut, exc. 22.5 cm but not exc. 30 cm long complete all as specified and directed.
M&L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
M&L for Mild steel TMT bars 5 mm to 10 mm dia.,cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned stacks, or stainless steel wire staples complete all as specified and directed.
S&F rolled mild steel in plates, gusset plate (plain or chequered) channels square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe-410W (Gde-E-250) quality-A complete all as specified and directed.
S & F of rolled mild steel sections as in framing of cladding, glazing, door or gates and the like fixed with angle cleats and connecting plates etc. confirming to Fe – 410 – W(Gde E - 250) quality 'A' complete all as specified and directed.
S & F of steel work as in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS – 1161 – 1979 grade St – 240 complete all as specified and directed.
S&F welded steel wire fabric and fixed complete to wood or steel members weight exceeding 4 Kg per Sqm.
S & F Steel windows with side hung shutters including box type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dove-tailed or welded complete all as specified and directed.
S&F steel ventilator with top hung shutter and including hinges steel peg stay complete all as specified and directed.
S & F of pressed steel frame of size 125 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates etc complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm TCT (total coated thickness) of any colour having tensile strength of 550 Mpa as in roof covering cladding to wall etc, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm TCT (total coated thickness) of any colour having tensile strength of 550 Mpa as in roof covering cladding to wall etc, fixed with self tapping screws complete all as specified and directed.
S&F in replacement 4 mm thick pre-painted E-fibre board Designer/Decorative fixed or laid/ inserted to with and including Anodised aluminium snap grid frame size 605x605 mm work for false ceiling Hangers with 6 mm dia. G.I. (length as required) adjusting level fixed to roof slabs/truss by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including necessary dimantling of existing unserviceable ceiling boards of any thickness including cover fillets complete all as specified and directed.
M&L for 100 mm thick cement concrete, type B2, 1:2:4 (using 40 mm graded stone aggregate) as in flooring and finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L 75 mm thick, PCC 1:3:6, type C-2, (using 20 mm graded crushed stone aggregate) as in plinth protection, hardstanding, floors, paths, etc, finished even and fair without using extra cement complete all as specified and directed.
M&L for Providing 100mm thick cement concrete 1:3:6 type C-1( using 20mm graded crushed stone aggregate) as in plinth protection laid in alternate bays (n exc 4 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified.
M&L for 100 mm thick cement concrete, type D 2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring finished rough to receive finishes complete all as specified and directed.
S&F 1.5 mm thick and 38 mm wide Aluminium dividing strips as in floors inserted in position, conform to design complete all as specified and directed.
M&L for Non - skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm laid on floor surface jointed and pointed with coloured cement over and including 15 mm thick screed bed in cement mortar 1:6 with bedding complete all as specified and as directed.
M&L Non Skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.11 sqm but n. exc. 0.18 sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including screed bed 15 mm thick in CM 1:6 complete all as specified and directed.
M&L coloured glazed ceramic tiles 450 x 300 x 7 mm thick as in dado / skirting and vertical surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10 mm thick screed bed in CM 1:3 including roughening of surface complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and fair without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L complete removal of existing treatment of old decorated wall surfaces and including applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
M & L for preparation of newly plastered or previously untreated surfaces of walls and applying two coats of oil bound distemper over a coat of primer and over a thin layer of wall care putty to obtain smooth finish complete all as specified and directed.
M&L for prepration of new plastered surfaces of wall and applying two coat of oil emulsion distemper of wall surfaces complete all as specified and directed.
M&L preparation of new plastered wall surfaces and including applying two coats of cement base paint complete all as specified and directed.
M & L for preparing newly plastered walls surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L complete removal of existing treatment and preparation of old plastered wall surfaces and including applying two coats of cement base paint over a coat of cement primer complete all as specified and directed.
S & F Sheet glass 3.0 mm thick, ordinary quality and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane glazed with putty or fixed with beads complete all as specified and directed.
S & F 3 mm thick Figured glass, pin headed type and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane.
M&L preparation of new wooden surfaces of any description, not otherwise described over 10 cm width or girth and including applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L preparation of new steel surfaces of any description, not otherwise described over 10 cm width or girth and including applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F 15 mm bore galvanised steel water tubing medium grade and including necessary GI fitting (such as bends, elbows, tees etc.) and fixed to wall / ceiling or laid in / on floor complete all as specified and directed.
S&F 20 mm bore galvanised steel water tubing medium grade and including necessary GI fitting (such as bends, elbows, tees etc.) and fixed to wall / ceiling or laid in / on floor complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
M&L for preparation of new steel surfaces of any description not exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified.
S&F rotational moulded polyethylene water storage tanks of 1000 Litres capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position and including 20 mm dia nipple suitable for HDPE water tank (minimum weight 45 gm), 20 mm bore ball valves (minimum weight 210 gm) high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed to 20 mm bore pipe & locking with GI wire (to prevent monkey menace) to tank complete all as specified and directed.
S&F 15 mm bore bib tap, brass chromium plated with crutch or butterfly handle, screwed for iron pipe or for brass ferrule & fixed complete all as specified and directed.
S&F pillar tap 15 mm bore,fancy type, cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without lettered “hot" or “cold” with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S & F 15 mm bore Stop valves, brass chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions (Minimum weight - 90gms) complete all as specified and directed.
S&F Ball valves 20mm dia high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20 mm - 210 gms ) complete all as specified and directed.
S&F PVC connections 15 mm size with PTMT nuts, of length 450 mm & suitable for cold/hot water supply complete all as specified and directed.
S & F 100 mm dia cast iron 'P' or 'S' trap fixed to pipes complete all as specified and directed.
S&F in repair swivel shower rose size 125 mm of brass chromium plated any colour (minimum weight 40 gms) for fixing with 15mm dia steel pipe complete all as specified and directed.
S & F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S&F in repairs vitreous china european water closet pan (pedestal pattern) white in colour with fixing bolts and flush pipe, connection to trap and to flushing cistern and all joints, including plastic water closet seat cover white, closed pattern with flat bottom and cover and mild steel CP hinges complete all as specified and directed.
S & F in repairs Vitreous China Squatting pan of Orissa pattern, size 580x440 mm size white with integral foot rest with Cast Iron `P' or `S' trap, front or back inlet and including connection to trap and to flushing pipe, anti-syphonage pipe etc., including trap set in and including lime concrete bedding complete including making good to floor (excluding flushing cistern and flush pipe)all as specified and directed.
S&F vitreous china wash hand basin white flat back of size not less than 550 x 400 mm with and including PVC waste pipe 32 mm bore, CP waste fitting and cutting for and pinning in ends of brackets etc, complete all as specified and directed.
S&F PVC low level flushing cistern of 10 litres capacity, valve less, syphonic action type, white body, with inlet ball valve, float and handle including brackets complete all as specified and directed.
E/M PORTION
M&L point wiring with 1.5 sqmm single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) concealed in wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one light / fan / exhaust fan / call bell point controlled by one 5 / 6 Amps switch and including cutting chasing (as required) and making good the disturbed surfaces including finishes to match with adjacent surfaces complete all as specified and directed.
All as per Sl. item No. 98.00 above but for one 5 / 6 Amps socket outlet point on same board.
All as per Sl. item No. 98.00 above but for one 5 / 6 Amps socket outlet point on independent board.
All as per Sl. item No. 98.00 above but for one 16 Amps socket outlet point on independent board with 2.5 sqmm cable and 2.5 sqmm earth wire
M & L concealed sub main wiring with 2 runs of 2.5 sqmm main wire along with 1 run of 2.5 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the disturbed surfaces including finishes to match with adjacent surfaces complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
M & L concealed sub main wiring with 2 runs of 4 sqmm main wire along with 1 run of 4 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the disturbed surfaces including finishes to match with adjacent surfaces complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
M & L concealed sub main wiring with 2 runs of 6 sqmm main wire along with 1 run of 6 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the disturbed surfaces including finishes to match with adjacent surfaces complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
S&F switch piano flush type one way, 5 / 6 Amps, 240 volt complete all as specified and directed.
S&F switch socket combination 3 pin 5 Amp, flush type universal complete all as specified and directed.
S&F switch socket combination 3 pin 15 Amp, flush type universal complete all as specified and directed.
S&F ceiling rose, 3 phase /PVC/ polycarbonate isolated body complete all as specified and directed.
S&F stepped type electronic fan regulator flush type, with 5 step, AC 50 Hz 240 Volts grade, 100W complete all as specified and directed.
S&F lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and as directed.
S&F in repairs LED battery backup inverter bulb of Lamp wattage: - 9 to 12 Watts, Battery: - Not less than 2200mAh or not less than 4 hrs backup,Efficeacy: - Not less than 110 Lm/Watt including taking down old unsv ones complete all as specified and directed.
S & F in repair Surface and wall mounted LED batten 20 watt 4ft long with Aluminum extruded housing , high quality polycarbonate diffuser & integrated Electronic Driver with IP20, PF 0.95, Efficiency not less than 110 lm/W color temp 6500k CRI ≥ 80, Operating Voltage range 140 V - 270 V complete all as specified and directed.
S&F LED batten light fitting 1 x 10 watt inverter (backup) type, 230 Volts, suitable for surface mounting, lithium ion battery with minimum 4 hrs backup time, extruded polycarbonate housing & extruded polycarbonate diffuser, lumen efficacy 110 Lm / watt (minimum), colour temperature 650 0K (minimum), CRI 80 (minimum), IP-20 (minimum), PF 0.90 (minimum), in-built surge protection 3.5 KV (minimum) inlcuding all fixing arragnement and electrically connecting from ceiling rose to light fitting & taking down complete all as specified and directed.
S & F in repair LED Bulk Head fitting 10 watt with Injection molded polycarbonate housing IP66, IK10, 3.5kV inbuilt surge protection, PF ≥0.95, total System Lumens not less than 1100 lm, 6500k CRI ≥ 80, Operating Voltage range 140 V - 270 V. complete all as specified and as directed.
S&F LED street / building security light fitting 1 x 20 watt, integrated type with high efficiency electronic driver, pressure die cast aluminium housing & PC diffuser, Lumen Efficacy 100 Lm/Watt (minimum), colour temperature 5700K (minimum), CRI 70 (minimum), IP-65 (minimum), PF 0.90 (minimum), THD 10% (Maximum), in-built surge protection 5 KV (minimum) internally prewired and including electrically connecting with twin core twisting flexible cord of 0.75 sqmm copper conductor cable & all other necessary fixing accessories such as GI pipe light grade of 40 mm bore (or higher size as per manufacturer recommendation) & suitable length with MS flat iron clamps (clamps shall be 40 x 5 mm MS flat), nuts, bolts & washers including painting to GI pipe & clamps with two coat of aluminium paint over a coat of red oxide primer complete all as specified & directed.
S&F in replacement old MCB DB including MCB / Isolated with new MCB DB, SPN 12 way, IP-43, IK 09, double door type with metal door, with 200A copper neutral and earth bus bar for fixing MCB, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed.
S&F MCB SPN 40 Amps 240V ,50 Hz ,breaking capacity 10 KA," C " series, complete all as specified and directed.
S&F MCB SP,10KA, 230V, C-curve, 6-32 amps complete all as specified and directed.
Supply and fix in repair of energy saving BLDC ceiling fan complete with all connected accessories as specified below: - Input Power: - 26 watts with full speed and reduced power consumption with reduced speed technology. Voltage: - 90-300 V AC, 50Hz, single Phase. RPM: - 340 to 375 rpm Blades: - Decorated Sweep: - 1200 mm. Air delivery: - Not less than 210 CFM Colour: - Glow white/Toast Brown/Gloss Black/or others as approved by Engr-in-Charge Speed/power control: -Without Remote through existing regulator. Star rating: - BEE 5 Star Rating Warranty: - As specified by the manufacturer, contractor shall produce original warranty and test certificate from the manufacturer.
M &L of Earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level connected using galvanised iron earth lead wire 4 Sq mm as earthing electrode by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe (medium grade) and other end connected to earthing test point as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth up to a distance not exceeding 50 Mtr etc all as shown on electrical plate No. 5 of MES Schedule Part-I complete including testing on completion. On testing after completion if the desired earth resistance is not obtained the earthing will be made again by the contractor at no additional cost and including dimantling complete all as specified and directed.
S&F 40 mm bore galvanised steel tubing, light grade with necessary fittings, fixed along electric pole etc, for cable protection complete all as specified and directed.
S&F Metal Plug Socket DB with sheet metal enclosures with two pin and earth plug and socket one double pole MCB 20 Amps,240V for Geysor connenction complete all as specified and directed.
S&F exhaust fan 300 mm sweep, heavy duty, metal body, 1400 RPM (minimum), AC single phase, 230 V, 50Hz along with louwer Shutter / bird guard, nuts, screws, bolts including electrical connection, writing MES number in 2 cm height with synthetic enamel paint and cutting wall for making hole and making good the disturbed surface to match the existing surface complete all as specified and directed. Note: Old unsv fans retrived from site deposited to the AGE EM Fan section and rate for the same is deemed to be included in the quotated rate.
S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and directed.
S&F geyser of 2KW of capacity 25 Litres, 230V, 50Hz, vertical, wall mounted type, BEE 5 star rated, steel outer body and copper inner tank with, incoloy glass coated heating element, adjustable thermostat for temperature regulation, multifunctional safety valve with & including 3 core copper cable of 1 to 2 metre length with 3-pin plug of 16A capacity, fixing arrangement such as. bracket, nuts, bolts washers etc. complete all as specified and directed.
SHRI ARUN BHATTACHERJEE
SHANTI UDYOG
M/s TALCO
SHRI N.DAS
M/S JAGRITI ENTERPRISES
GEETA CONSTRUCTION
DEBABROTA ROY CHOWDHURY
PS ENTERPRISE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .