Principal, S.G.G.S College, Sector-26, Chandigarh
Principal, S.G.G.S College, Sector-26, Chandigarh
Construction of Two(02) Classrooms in S.G.G.S College, Sector-26, Chandigarh Under RUSA Scheme
2020_CHD_57402_1
SGGS/RUSA/NC/001
Open Tender
Civil Works
Item Rate
60 days
work
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,500
Principal, S.G.G.S College, Sector-26, Chandigarh
₹48,000
Yes
9 Dec 2020
30 Nov 2020
7 Dec 2020
30 Nov 2020
7 Dec 2020
30 Nov 2020
90 days
Amount
PART -A(CIVIL WORKS) Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.DSR 2.8
All kinds of soil.DSR 2.8.1
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc, in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5m.
Supplying and filling in plinth with fine sand under floors including, watering, ramming consolidating and dressing complete.
Providing & laying in position cement concrete of specified grade excluding the cost of centering & shuttering- All work upto plinth level:
1: 5: 10 (l cement: 5 course sand: 10 stone aggregate)
Centering and shuttering including strutting, propping etc. and removal of form for:
Foundation, footing, bases of column etc.
Suspended floors, Roof, Landing, Balconies and access plateform
Lintels, beams, plinth beams, girders, bressuners and cantilevers.
Columns, pillars, peirs, abutments, posts and struts.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.
(Note:-Cement content considered in this item is @ 320 kg/ cum. Excess/ less cement used as per design mix is payable/ recoverable separately).
All work upto plinth level
All work above plinth level up to floor V level.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1: 6 (1 cement: 6 fine sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:
Cement mortar 1: 6 (1 cement: 6 fine sand)
Providing and fixing glazed shutters for doors, windows and clerestory windows using 5 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.
Kiln seasoned and chemically treated hollock Wood
35mm thick
providing and fixing 5mm thick clear glass of approved make in windows, ventilators etc
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part 1) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains and cross bands and face veneers on both faces of shutters
35 mm thick including necessary M.S screws but excluding the cost of butt hinges
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws:
35 mm thick shutters
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per is IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
Twin rubber stopper
Providing and fixing pressed steel door frames conforming IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb. lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer in-charge:
Profile E
Fixing with adjustable lugs with split end tail to each jamb
(Note: The Centre mullion in any door & window frame will be counted & paid 1.5 times of outer section, for its clear length)
Providing and laying cement concrete flooring 1:2:4 finishing with a floating coat of neat cement, including cement slurry complete
Providing gola 75x75 mm in cement concrete 1: 2: 4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1: 3 (cement: 3 fine sand) as per standard design:
In 75x75mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1: 2: 4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x 1 m x 400 micron, finished with 12 mm cement plaster 1: 3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
110 mm diameter
Providing and fixing on wall face unplasticised-PVC moulded fittings/ accessories for unplásticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS: 5382. leaving 10 mm gap for thermal expansion, (i) Single socketed pipes
110 mm bend
12 mm cement plaster of mix
1: 6 (1 cement : 6 fine sand)
White wash and colour washing (three coats) complete in all respect
Finishing walls with Acrylic Smooth exterior paint of required shade:
New work (Two or more coat applied @1.67 ltr/10 sqm over and including priming coat of exterior primer applied @2.20 kg/10 sqm)
Painting with synthetic enamel paint of approved brand & manufacturer to give an even shade:
Applying priming coat:
With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Providing & fixing M.S. railing, grills, guard bars etc. as & where required consisting of M.S. flat/solid square bars / M.S. angle etc. as per architectural drawings & fixing in position including welding charges, cost of one coat of anti-corrosive metal primer & two coats of special quality paint of approved shade complete in all respect.
PART-C (ELECTRICAL WORK) Wiring for light point / fan point/ call bell point/ Exhaust fan point with 1.5 sq mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq mm FR PVC insulated copper conductor single core cable etc as required.
S & F of stepped type electronics fan regulator in the existing modular plate switch box including connections but excluding modular plate etc.
Installation, T & C of ceiling fan, including wiring the down rods of standard length (upto 30cm) with 1.5 sqmm FR PVC Insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover in the fan box etc. as required.
Supplying and fixing following way prewired vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box of steel sheet, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FR PVC insulated copper conductor upto the terminal connector/neutral link, earthing etc as required (But without MCB/ RCCB / Isolator). (Note: Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.)
8 way double door
S & F SP MCB 5 to 32 Amp suitable for 240/415 volts C series MCB suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.
Triple pole and Neutral
Supply of PVC/ XLPE insulated Copper conductor armoured and served cable working voltage 1100 volt Grade through walls/ ceiling with appropriate clamps and fixing arrangements, cable tray etc. as per specifications and drawings.
4 Core 16 Sq mm
BRIJ NANDAN
SURESH KUMAR
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .