| 1 | L1₹42.1 LAccepted-AOC HOUSE NO 41 WARD NO 09 ARYA SAMAJ GALI UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹42.4 L+₹9,874.27 (0.23%)Rejected-Finance 146 B BARI BRAHMANA JAMMU JAMMU AND KASHMIR 181133 | SAMBA | JAMMU AND KASHMIR | 181133 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹42.4 L+₹15,655.27 (0.37%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹44.5 L+₹2.3 L (5.33%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹46.6 L+₹4.3 L (10.2%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L5 | Rejected-Finance OTHER THAN L1 |
| Sl No | Description | Qty | Unit | MOHAN LAL AND SONS L5 | M/S N K POWER SYSTEMS AND PROJECTS L1 | FANGALIA TRADERS L8 | jaima electricals L2 | PREM NATH KHAJURIA AND SONS L4 | PROACH ASSOCIATES BUILDERS & ENGINEERS L7 | Prakash Trading Corporation L6 | DAVINDER SINGH L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down old U/S Earth Plate, M&Lfor earthing with Galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick, with earth strip 25 mm x 4 mm protected by galvanised iron or steel pipe 40 mm bore light grade with Watering pipe 20 mm bore GI medium grade. The rate of earthing shall be inclusive of necessary earth work in any type of soil, charcoal, salt, funnel, PCC pit and RCC cover with handle complete as per electrical plate No. 3 of MES SSR Part-I, complete all as specified and directed by Engr-in-Charge. | 18 | Each Set | 2,500 ₹45,000 Lowest | 5,000 ₹90,000 | 5,000 ₹90,000 | 3,500 ₹63,000 | 4,200 ₹75,600 | 5,500 ₹99,000 | 2,600 ₹46,800 | 5,000 ₹90,000 |
| 2.00 | S&F straight through joint kit, heat shrinkable type suitable for 35 to 95 sqmm LT UG Cable complete all as specified and directed. | 20 | Each | 1,000 ₹20,000 Lowest | 2,000 ₹40,000 | 3,000 ₹60,000 | 4,300 ₹86,000 | 2,200 ₹44,000 | 1,500 ₹30,000 | 1,700 ₹34,000 | 1,500 ₹30,000 |
| 3.00 | S&F straight through joint kit, heat shrinkable type suitable for 120 to 185 sqmm LT UG Cable, complete all as specified and directed by Engr-in-Charge. | 15 | Each | 1,000 ₹15,000 Lowest | 2,500 ₹37,500 | 5,000 ₹75,000 | 5,100 ₹76,500 | 2,200 ₹33,000 | 1,900 ₹28,500 | 1,900 ₹28,500 | 2,200 ₹33,000 |
| 4.00 | S&F straight through joint kit, heat shrinkable type suitable for 240 to 400 sqmm LT UG Cable, complete all as specified and directed by Engr-in-Charge. | 4 | Each | 1,000 ₹4,000 Lowest | 3,000 ₹12,000 | 5,000 ₹20,000 | 4,100 ₹16,400 | 2,350 ₹9,400 | 2,200 ₹8,800 | 2,200 ₹8,800 | 4,000 ₹16,000 |
| 5.00Supply and Laying and fixing in replacement of unservicable /corroded overhead conductor/underground cable jointing and testing LT Cross Linked Polythene Insulated(XLPE insulated) galvanized steel strip armoured electric cable 1100 volt grade heavy duty ISI marked with aluminium conductor and overall served with an outer sheath of PVC, of cross sectional area including taking down as under, complete all as specified and directed by Engr-in-Charge :- (Note : (i) Excavation, earthwork, Sand Cushioning, Cable covers, Pipe for cable protection to be measured and paid for separately) | |||||||||||
| 5.01 | 25 sqmm 3.5 core. | 600 | RM | 180 ₹1,08,000 Lowest | 200 ₹1,20,000 | 260 ₹1,56,000 | 264 ₹1,58,400 | 205 ₹1,23,000 | 180 ₹1,08,000 Lowest | 230 ₹1,38,000 | 185 ₹1,11,000 |
| 5.02 | 35 sqmm 3.5 core. | 550 | RM | 200 ₹1,10,000 Lowest | 240 ₹1,32,000 | 300 ₹1,65,000 | 264 ₹1,45,200 | 249 ₹1,36,950 | 240 ₹1,32,000 | 320 ₹1,76,000 | 235 ₹1,29,250 |
| 5.03 | 50 Sqmm 3.5 core. | 500 | RM | 285 ₹1,42,500 Lowest | 330 ₹1,65,000 | 350 ₹1,75,000 | 350 ₹1,75,000 | 338 ₹1,69,000 | 330 ₹1,65,000 | 410 ₹2,05,000 | 300 ₹1,50,000 |
| 5.04 | 70 Sqmm 3.5 core. | 450 | RM | 390 ₹1,75,500 Lowest | 420 ₹1,89,000 | 400 ₹1,80,000 | 480 ₹2,16,000 | 445 ₹2,00,250 | 470 ₹2,11,500 | 510 ₹2,29,500 | 435 ₹1,95,750 |
| 5.05 | 95 sqmm 3.5 core. | 250 | RM | 480 ₹1,20,000 | 550 ₹1,37,500 | 460 ₹1,15,000 Lowest | 600 ₹1,50,000 | 570 ₹1,42,500 | 550 ₹1,37,500 | 690 ₹1,72,500 | 550 ₹1,37,500 |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
29 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (UTILITIES) UDHAMPUR
GE (UTILITIES) UDHAMPUR, PO-GARHI, PIN-182121
Repair/Maint to LT network system in Chinar, PB Enclave, NCSR and other locations under GE (U) Udhampur.
2025_MES_723807_1
GE/U-48/2025-26
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (UTILITIES) UDHAMPUR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (UTILITIES) UDHAMPUR
₹97,000
17 Oct 2025
1 Aug 2025
1 Sept 2025
1 Aug 2025
29 Aug 2025
15 Aug 2025
Amount
Taking down old U/S Earth Plate, M&Lfor earthing with Galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick, with earth strip 25 mm x 4 mm protected by galvanised iron or steel pipe 40 mm bore light grade with Watering pipe 20 mm bore GI medium grade. The rate of earthing shall be inclusive of necessary earth work in any type of soil, charcoal, salt, funnel, PCC pit and RCC cover with handle complete as per electrical plate No. 3 of MES SSR Part-I, complete all as specified and directed by Engr-in-Charge.
S&F straight through joint kit, heat shrinkable type suitable for 35 to 95 sqmm LT UG Cable complete all as specified and directed.
S&F straight through joint kit, heat shrinkable type suitable for 120 to 185 sqmm LT UG Cable, complete all as specified and directed by Engr-in-Charge.
S&F straight through joint kit, heat shrinkable type suitable for 240 to 400 sqmm LT UG Cable, complete all as specified and directed by Engr-in-Charge.
Supply and Laying and fixing in replacement of unservicable /corroded overhead conductor/underground cable jointing and testing LT Cross Linked Polythene Insulated(XLPE insulated) galvanized steel strip armoured electric cable 1100 volt grade heavy duty ISI marked with aluminium conductor and overall served with an outer sheath of PVC, of cross sectional area including taking down as under, complete all as specified and directed by Engr-in-Charge :- (Note : (i) Excavation, earthwork, Sand Cushioning, Cable covers, Pipe for cable protection to be measured and paid for separately)
25 sqmm 3.5 core.
35 sqmm 3.5 core.
50 Sqmm 3.5 core.
70 Sqmm 3.5 core.
95 sqmm 3.5 core.
120 sqmm 3.5 core.
150 sqmm 3.5 core.
300 sqmm 3.5 core.
Taking down old unserviceable panel & Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings MCCBs are to busbar spadles to fitted complete base frame of 50x50x6mm angle iron,powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following, complete all as specified and directed by Engr-in-Charge :- Note :- All Scrap retrieved from Ser Item No 6.00, 7.00, 8.00, 9.00, 10.00 & 11.00 wil be deposited in the MES Yard. Incoming (a) MCCB 200 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-01 No, (b) Bus bar electrolytic grade Aluminium and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 500 Amp,4 pole, not less than 1 MTR long mounted on insulators - 01 set
Outgoing (a) MCCB 100 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 25 KA-03 No, (b) MCCB 63 Amps 4 pole , Ics=100%Icu-25/26 KA, 415 Volts,, with thermal adjustable and fixed magnetic setting with extended terminals -01 No. Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands. (v) including suitable thimbles/lugs, nut bolts ,washers fitted the cables. (vi) cable glands for incoming and out going suitable cables is including rate quoted by vendover. (vii) 02 No's of Earhing connecting the same panel will be measured and paid separately.
Description all as Ser items No 6.00 above but following capacity, complete all as specified and directed by Engr-in-Charge :- Incoming (a) MCCB 400 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA- 1 No, (b) Change Over 400 A with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-01 No, (c) Bus bar electrolytic grade Aluminium and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 1000 Amp,4 pole, not less than 1 MTR long mounted on insulators 01 set.
Outgoing (a) MCCB 250 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-02No, (b) MCCB 160 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 25 KA-01 No, Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands. (v) including suitable thimbles/lugs, nut bolts ,washers fitted the cables. (vi) cable glands for incoming and out going suitable cables is including rate quoted by vendover. (vii) 02 No's of Earhing connecting the same panel will be measured and paid separately.
Description all as Ser items No 6.00 above but following capacity, complete all as specified and directed by Engr-in-Charge :- Incoming (a) MCCB 400 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA- 1 No, (b) Bus bar electrolytic grade Aluminium and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 1000 Amp,4 pole, not less than 1 MTR long mounted on insulators 01 set.
Outgoing (a) MCCB 250 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-02 Nos, (b) MCCB 160 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 25 KA-02 No, Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands. (v) including suitable thimbles/lugs, nut bolts ,washers fitted the cables. (vi) cable glands for incoming and out going suitable cables is including rate quoted by vendover. (vii) 02 No's of Earhing connecting the same panel will be measured and paid separately.
Description all as Ser items No 6.00 above but following capacity, complete all as specified and directed by Engr-in-Charge :- Incoming (a) MCCB 400 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA- 1 No, (b) Bus bar electrolytic grade Aluminium and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 1000 Amp,4 pole, not less than 1 MTR long mounted on insulators 01 set.
Outgoing (a) MCCB 250 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-03 No, (b) MCCB 160 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 25 KA-01No, Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands. (v) including suitable thimbles/lugs, nut bolts ,washers fitted the cables. (vi) cable glands for incoming and out going suitable cables is including rate quoted by vendover. (vii) 02 No's of Earhing connecting the same panel will be measured and paid separately.
Description all as Ser items No 6.00 above but following capacity, complete all as specified and directed by Engr-in-Charge :- Incoming (a) MCCB 400 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA- 1 No, (b) Bus bar electrolytic grade Aluminium and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 1000 Amp,4 pole, not less than 1 MTR long mounted on insulators 01 set.
Outgoing (a) MCCB 320 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-02 No, Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands. (v) including suitable thimbles/lugs, nut bolts ,washers fitted the cables. (vi) cable glands for incoming and out going suitable cables is including rate quoted by vendover. (vii) 02 No's of Earhing connecting the same panel will be measured and paid separately.
Description all as Ser items No 6.00 above but following capacity, complete all as specified and directed by Engr-in-Charge :- Incoming (a) MCCB 320 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-01 No, (b) Bus bar electrolytic grade Aluminium and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 800 Amp,4 pole, not less than 1 MTR long mounted on insulators 01 set.
Outgoing (a) MCCB 200A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-01 No, (b) MCCB 160 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 25 KA-01No, (c) MCCB 100 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 25 KA-01 No, Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands. (v) including suitable thimbles/lugs, nut bolts ,washers fitted the cables. (vi) cable glands for incoming and out going suitable cables is including rate quoted by vendover. (vii) 02 No's of Earhing connecting the same panel will be measured and paid separately.
Removing existing old same stickers & supply and pasting of stickers on transformer/Panel body using industrial-grade adhesive of custom-designed glue-based weatherproof stickers for transformers, size 6"x4", UV & water-resistant with the Following Details. Material: Vinyl or equivalent high-grade sticker with lamination, complete all as specified and directed by Engr-in-Charge. Note: 1) Sticker will be full-color digital print with lamination for UV protection. (surface to be cleaned before pasting). 2) Words (in English) for printing will be given by Engineer-in-charge during Execution.
Removing old unserviceable cable trays & supply, installation, testing, and commissioning of heavy-duty hot-dip galvanized wire mesh cable tray system, minimum 80-micron zinc coating, suitable for XLPE power cables of size 50 sq.mm to 400 sq.mm, including trays of minimum 100mm depth and 400mm width, 5mm dia welded mesh wire, and all necessary accessories like horizontal/vertical bends, tees, crosses, end caps, jointing couplers, and supporting hardware. Installation shall be on wall, ceiling, or structural frames using GI brackets, threaded rods, anchor bolts, beam clamps,console and other hardware as per site requirement. The system shall be aligned and secured for heavy-duty cable routing, with edges filed for smoothness to avoid cable damage. Work shall conform to IS/IEC standards and electrical specifications, complete all as specified and directed by Engr-in-Charge. Make : Legrand/ C&S/ L&T Note :- All scrap retrieved from Ser Item No 13.00 will be deposited in the MES Yard.
Supply and installation of heat shrinkable/PVC cable sleeves with color-coded as per phase identification (Red, Yellow, Blue, Black, Green), suitable for LT Aluminium/aluminum cables of sizes ranging from 16 mm² to 300 mm², with thickness not less than 1.2 mm and temperature rating ≥ 90°C. The scope includes cutting, cleaning of cables, and proper application of sleeves with hot air gun or flame torch to ensure tight adhesion without air pockets. Work shall conform to IS: 7098/IS: 13592 and standard electrical practices, complete all as specified and directed by Engr-in-Charge.
M&L for aluminium thimble cable (Lugs) suitable for Cable of following sizes, complete all as specified and directed by Engr-in-Charge :-
Description all as Ser items No 15.00 above here-in-before but for size 25 sqmm to 70 Sqmm, complete all as specified and directed by Engr-in-Charge.
Description all as Ser items No 15.00 above here-in-before but for size 95 Sqmm to 120 Sqmm, complete all as specified and directed by Engr-in-Charge.
Description all as Ser items No 15.00 above here-in-before but for size 150 Sqmm to 240 Sqmm, complete all as specified and directed by Engr-in-Charge.
Description all as Ser items No 15.00 above here-in-before but for size 300 Sqmm to 400 Sqmm, complete all as specified and directed by Engr-in-Charge.
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil, complete all as specified and directed by Engr-in-Charge.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick, complete all as specified and directed by Engr-in-Charge.
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed by Engr-in-Charge.
S&F, in replacement double walled corrugated (DWC) pipe of size 160 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT/LT cable in under ground, complete all as specified and directed by Engr-in-Charge.
S&F, in replacement double walled corrugated (DWC) pipe of size 120 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT/LT cable in under ground, complete all as specified and directed by Engr-in-Charge.
S&F, in replacement double walled corrugated (DWC) pipe of size 90 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT/LT cable in under ground, complete all as specified and directed by Engr-in-Charge.
S&F, in replacement double walled corrugated (DWC) pipe of size 75 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT/LT cable in under ground, complete all as specified and directed by Engr-in-Charge.
Taking down old busbar and supply, install, 200 amp copper Bus bar with enclouser wall mounted size 400 mmX300 mm ,suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 2 mm CRCA MS sheet for cable entry and locking arrangement, complete all as directed and specified by Engineer-in-charge. Note :- All scrap retrieved from Ser Item No 23.00 will be deposited in the MES Yard.
Disconnecting & taking out the existing Unserviceable MCCB from panel and S&F new MCCB of following rating and breaking cap of suitable frame size, 4 Pole, 415 V, 50 Hz, 3 phase including extension terminals and connecting using suitable fasteners, modification/fabrication if any complete all as required at site, complete all as specified and directed by Engr-in-Charge :- Note :- All scrap retrieved from Ser Item No 24.00 will be deposited in the MES Yard.
63 amp, 25 KA
100 amp, 25 KA
125 amp, 25 KA
160 amp, 25 KA
200 amp, 35/36 KA
250 amp, 35/36 KA
350 amp, 35/36 KA
400 amp, 35/36 KA
jaima electricals (BID ID -3402961)
DAVINDER SINGH (BID ID -3402306)
PREM NATH KHAJURIA AND SONS (BID ID -3398347)
MOHAN LAL AND SONS (BID ID -3409983)
Prakash Trading Corporation (BID ID -3402323)
PROACH ASSOCIATES BUILDERS & ENGINEERS (BID ID -3399013)
FANGALIA TRADERS (BID ID -3410097)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .