| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAccepted-AOC | L1 | Accepted-AOC Quoted lowest rate | |
| 2 | L2₹17.7 L+₹56,265 (3.28%)Rejected-Finance | L2 | Rejected-Finance Quoted other than lowest rate | |
| 3 | L3₹17.8 L+₹65,025 (3.79%)Rejected-Finance | L3 | Rejected-Finance Quoted other than lowest rate | |
| 4 | L4₹18.3 L+₹1.1 L (6.39%)Rejected-Finance | L4 | Rejected-Finance Quoted other than lowest rate | |
| 5 | L5₹19.4 L+₹2.2 L (12.7%)Rejected-Finance | L5 | Rejected-Finance Quoted other than lowest rate |
Tender Value
Refer Docs
EMD Value
₹42,600
Closing Date
30 Nov 2020, 6:00 pmClosed
Shri Sachin H Chavan IDSE
SPECIAL REPAIR/REPLACEMENT OF CEILING FAN, PROVN OF CEILING FAN, GEYSER AND LIGHTENING CONDUCTOR UNDER GE NORTH AT BATHINDA MIL STN
SPECIAL REPAIR/REPLACEMENT OF CEILING FAN, PROVN OF CEILING FAN, GEYSER AND LIGHTENING CONDUCTOR UNDER GE NORTH AT BATHINDA MIL STN
2020_MES_390801_1
8935/NIT-34/20-21
Open Tender
Electrical and Maintenance Works
Item Rate
122 days
Bathinda Mil Stn
Class E
9 documents required · 9 mandatory
₹500
GE (North) Bathinda
₹42,600
Yes
15 Dec 2020
29 Oct 2020
2 Dec 2020
29 Oct 2020
30 Nov 2020
16 Nov 2020
29 Oct 2020 - 5 Nov 2020
Amount
Disconnecting electric connection and taking down carefully old existing ceiling fan complete with hanging rod, canopy, clamp, rubber real, nut bolt etc but except fan regulator and Disconnecting electric connection & water connection and taking down carefully old existing Geyser except PVC connection ( any size/make and in any condition ceiling fan and geyser) from sites as directed and deposit it into AGE E/M Store yard complete all as specified and as directed by Engineer-in-charge.
Supply and hanging/fixing ceiling fan 1200 mm sweep in white colour, 50watt, copper winding, 3 Blade, single phase, 230 volts 50 Hz double ball bearing, energy saver/energy-efficient, alongwith hanging rod (length as per site requirement or as directed by Engineer-in-charge), canopy (lower and upper), rubber real, nut bolts, lock pin etc. including making electrical connection with flexible round twin core multi strand copper cable suitable size complete all as specified and as directed by Engineer-in-Charge. Make and cat part :- Entrust 50 of Crompton / Energia of USHA / ES Plus of Havelles Note :- (i) Srl Number of ceiling fan and 'GE North BTD' shall also be writing on fan with red colour permanent marker, which will be issued by Engineer-in-Charge and cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account. (ii) Ceiling fan installed/hanging at various locations as directed by Engineer-in-charge with in the Jurisdiction of GE North Bathinda (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account
Supply and fixing stepped type (1-5), electronic Fan regulator (two module), 100 watt, 250 volts, regulator fixing in existing switch board (at any site) on laminated sheet including making elctric connection and testing, including making fixing arrangement i.e. cutting of sheet if required or in lieu of blanking plate or in lieu of unserviceable regulator, including screws complete all as specified and as directed by Engineer-in-charge. Make :- Crab tree / HAVELLS / LEGRAND / Indo Asian / SSK / Anchor
Supply and fixing water heater (Geyser) storage type of capacity 50 Ltrs, energy saver/energy-efficient Star rating, 230V, 2KW element, single phase AC supply, inner tank made out of heavy duty stainless steel sheet glass line coated, having pressure release valve, non return valve and drain valve, thermostat with auto cut off etc, hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface as per existing surfaces, including electric, earthing and water connection to geyser and testing on load ( Filled with water ) upto entire satisfaction of Engineer-in-Charge/JE complete all as specified and directed by Engineer-in-Charge. Make - Usha / Venus/Bajaj / Kenstar/ Victor Note :- (i) Srl Number of geyser and 'GE North BTD' shall also be writing on geyser with red colour permanent marker, which will be issued by Engineer-in-Charge and cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account. (ii) Geyser installed/hanging at various locations as directed by Engineer-in-charge with in the Jurisdiction of GE North Bathinda (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account
Supply and fixing water heater (Geyser) storage type of capacity 25 Ltrs, energy saver/energy-efficient Star rating, 230V, 2KW element, single phase AC supply, inner tank made out of heavy duty stainless steel sheet glass line coated, having pressure release valve, non return valve and drain valve, thermostat with auto cut off etc, hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface as per existing surfaces, including electric, earthing and water connection to geyser and testing on load ( Filled with water ) upto entire satisfaction of Engineer-in-Charge/JE complete all as specified and directed by Engineer-in-Charge. Make - Usha / Venus/Bajaj / Kenstar/ Victor Note :- (i) Srl Number of geyser and 'GE North BTD' shall also be writing on geyser with red colour permanent marker, which will be issued by Engineer-in-Charge and cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account. (ii) Geyser installed/hanging at various locations as directed by Engineer-in-charge with in the Jurisdiction of GE North Bathinda (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account
Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete along walls, ceiling and laid in floor or concealed in walls, including cutting hole in brick wall to pass the pipe out side for connection as per site requirment and making good disturbed surfaces of walls by using CM (1:3) to matching with existing surfaces including cutting and threading of existing pipe any dia for insertaion of tee branch complete all as specified and as directed by Engineer-in- charge. Make :- TATA / JINDAL / ZENITH / SWASTIK
Supply & fixing 600 mm long PVC connection 15mm size with Brass CP nuts, ring washer, heavy duty suitable for hot water complete all as specified & directed by Engineer-in-charge.
Supply and fixing stop valve/angle valve cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed both end for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS. Make :- PRAYAG / JAQUAR (CLARION) / GROHE / KOHLER / HINDWARE
Supply and fixing bib tap cast copper alloy, chromium plated, fancy type with crutch or butterfly handle with capstan head, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS. Make :- PRAYAG / JAQUAR (CLARION) / GROHE / KOHLER / HINDWARE
Material and labour for surface sub main wiring with 2.5 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through and including PVC casing caping suitable size as per wiring norms (heavy duty ISI marked), on independent circuit from existing DB and including one run 2.5 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC rawl plug, screw etc. including cutting hole in brick wall to pass the wire as per site requirment and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 2.5 sqmm copper wire and one run casing caping shall be measured as one RM length for payment. Make of wire :- RR KABEL LTD / L&T / FINOLEX / RALLISON / HAVELLS / NICCO Make of casing caping :- Polycab / AKG / Prince / Supreme / Finolex
Supply and fixing (concealed in wall or as directed) single pole and neutral sheet metal enclosure (AC Box) with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 240 volts, AC supply complete all as specified and directed by Engineer-in-Charge. Make :- SCHNEIDER / L & T / C & S / SIEMENS / HAVELLES / LEGRAND
Supply and fixing Air termination, single pointed aluminium rod 12mm dia and 300mm long at roof of building/shed at any height, rod fixing/grouted in PCC block of size 200x200x300mm made by PCC (1:2:4) B-1 using 20mm stone aggregate including form work complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Aluminium strip 25 x 3.15mm fixing with suitable size saddles and fixing screws etc. for roof conductors and down conductors (building at any height) above ground including making good to disturbed surfaces complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing copper strip 32 x 6mm as earth continuity conductor/loop earthing or main earthing lead fixed to wall with saddles or chases or buried in ground etc. or any other indicated situation complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Earthing complete with copper earth plate electrode of size 60cm x 60cm x 3.15mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity copper strip 32x6 mm (upto test point from earth plate i.e. 7.5m minimum) by means of GI bolts/nuts/washers and including protected by 40mm dia GI light grade protection pipe from earth plate to test point. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, CI cover 10mm thick hanged to CFI frame, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate), including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR Part – I complete all as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Test point shall be measured & paid separately under appropriate item of this BOQ (iii) Earthing result should be less than 3 Ohms and the earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos, 8mm dia 25mm long hex head screw including junction box made out of GI sheet 2mm thick, suitable size appximate 180 x 100 x 50mm, with provision of openable side hung shutter easy to use for test point terminal complete all as specified and as directed by Engineer-in-charge.
Note:- The cost of any minor item like adhesive tape, nut bolt, screws, washers, insulating tape, rubber gasket, rubber washer etc. as per requirement to complete the job shall be included in the unit rate of BOQ items.
Dhriti Constructions
M/s Pioneer Construction Co.
NASIB ENGINEERS AND CONSTRUCTION
PREM ENTERPRISES
M/s VISHAL ELECTRIC STORE
Rasvinderpalandco
m/s s.n. builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .