Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹3.3 Cr AT PO MATIHANI BEGUSARAI BIHAR 851101 MAIL ID KIEP 7892 GMAIL COM | ₹3.3 Cr |
Tender Value
₹4.6 Cr
EMD Value
₹4.6 L
Closing Date
7 Oct 2025, 11:00 amClosed
Renovation and Conversion of D Block (Ground Floor) of Administrative Building into Projects Office Building in Bokaro Steel City, Jharkhand
NBCC/SBG/etender/2025/165
NBCC/SBG/etender/2025/165
Open Tender-Domestic
Civil Works General
Bokaro, Jharkhand
₹11,800
₹4.6 L
16 Jul 2026
30 Sept 2025
7 Oct 2025
7 Oct 2025
6 Nov 2025
ABSTRACT OF COST
Name of the work :Cost Estimate for Renovation and conversion of D Block (Ground Floor)
of Administrative Building into Projects office building at Bokaro Steel City, Jharkhand.
S.H. No. Description of Sub-Head Amount (Rs) Amount (Rs)
1 Civil Finshing Works : 1,89,29,998 16,57,648
2 Electrical Works : 78,64,603 62,99,987
3 Plumbing Works : 11,61,227 13,94,265
4 HVAC Works : 53,97,038
5 Conference furniture 29,34,980
After Correction Factor 0.973 Included in Rate
Addl. Cost Index on DSR Included in Rate
W Grand Total 4,56,39,745
W Grand Total 4,56,39,745
Digitally signed by PRIYA
ABSTRACT OF COST
Name of the work : Renovation and conversion of D Block (Ground Floor) of Administrative
Building into Projects office building at Bokaro Steel City, Jharkhand.
S.H. No. Description of Sub-Head Amount (Rs)
A Schedule Items
01. Earth Work : 3,82,468
02. Concrete Work : 2,42,930
03. Reinforced Cement Concrete : 8,88,890
04. Masonry Work : 29,98,357
06. Cladding Work : 8,46,433
07. Wood and P.V.C. Work : 23,20,752
08. Steel Work : 9,80,944
11. Finishing : 42,13,540
19. Aluminium Work : 13,89,586
20. Water Proofing : 1,23,555
24. New Technologies and Materials : 89,750
B Non Schedule Items : 16,57,648
EstimateDigitally
signed by PRIYA
Description of Item Quantity unit Rate (Rs) Amount(Rs)
Sub-Head : Earth Work
2.6 Earth work in excavation by mechanical means (Hydraulic
excavator) / manual means over areas (exceeding 30cm in
depth, 1.5m in width as well as 10 sqm on plan) including
getting out and disposal of excavated earth, lead up to
50m and lift up to 1.5m,as directed by Engineer-in-
2.6.1 All kinds of soil 55.50 Cum 189.98 10543.79
2.7 Earth work in excavation by mechanical means (Hydraulic
excavator) / manual means over areas (exceeding 30 cm
in depth, 1.5m in width as well as 10 sqm on plan)
including getting out and disposal of excavated earth, lead
up to 50 m and lift up to 1.5m, as directed by Engineer-in-
2.7.1 Ordinary rock 5.55 Cum 533.97 2963.55
2.25 Filling available excavated earth (excluding rock) in 47.79 Cum 209.78 10025.33
trenches, plinth, sides of foundations etc. in layers not
exceeding 20cm in depth, consolidating each deposited
layer by ramming and watering, lead up to 50 m and lift
2.25A Excavating, supplying and filling of local earth (including 10.00 Cum 749.75 7497.45
royalty) by mechanical transport up to a lead of 5 km, also
including ramming and watering of the earth in layers not
exceeding 20 cm in trenches, plinth, sides of foundation
etc., complete.
Digitally signed by PRIYA
Description of Item Quantity unit Rate (Rs) Amount(Rs)
2.27 Supplying and filling in plinth with sand under floors, 18.02 Cum 2273.05 40952.17
including watering, ramming, consolidating and dressing
2.28 Surface dressing of the ground including removing
vegetation and inequalities not exceeding 15 cm deep and
disposal of rubbish, lead up to 50 m and lift upto1.5 m.
2.28.1 All kinds of soil. 160.00 Sqm 36.55 5848.12
2.34 Supplying chemical emulsion in sealed containers
including delivery as specified.
2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 268.13 Ltr 251.25 67367.19
2.35 Diluting and injecting chemical emulsion for POST-
CONSTRUCTIONAL anti- termite treatment (excluding the
cost of chemical emulsion) :
2.35.3 Treatment of soil under existing floors using chemical
emulsion @ one litre per hole, 300 mm apart including
drilling 12 mm diameter holes and plugging with cement
mortar 1 :2 (1 cement : 2 Coarse sand) to match the
existing floor :
2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% 715.00 Sqm 331.85 237270.26
Total of the Sub-Head - Earth W ork : 382467.86
Sub-Head : Concrete Work
4.1 Providing and laying in position cement concrete of
specified grade excluding the cost of centering and
shuttering - All work up to plinth level :
4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from 11.00 Cum 7290.88 80199.72
natural sources : 8 graded stone aggregate 40 mm
nominal size derived from natural sources).
4.17 Making plinth protection 50mm thick of cement concrete 85.00 Sqm 801.98 68167.94
1:3:6 (1 cement : 3 coarse sand (zone-III) derived from
natural sources : 6 graded stone aggregate 20 mm
nominal size derived from natural sources) over 75mm
thick bed of dry brick ballast 40 mm nominal size, well
rammed and consolidated and grouted with fine sand,
including necessary excavation leveling & dressing &
finishing the top smooth.
4.20 Providing and laying in position ready mixed or site
batched design mix cement concrete for plain cement
concrete work; using coarse aggregate and fine aggregate
derived from natural sources, Portland
Pozzolana/Ordinary Portland/Portland Slag cement,
admixtures in recommended proportions as per IS : 9103
to accelerate/ retard setting of concrete, to improve
durability and workability without impairing strength;
including pumping of concrete to site of laying, curing,
carriage for all leads; but excluding the cost of centering,
shuttering and finishing as per direction of the Engineer-
in-charge; for the following grades of concrete.
Note : Extra cement upto 10% of the minimum specified
cement content in design mix shall be payable separately.
In case the cement content in design mix is more than
110% of the minimum specified cement content, the
contractor shall have discretion to either re-design the
mix or bear the cost of extra cement.
4.20.1 All works up to plinth level:
4.20.1.1 Concrete of M-10 grade with minimum cement content of 10.00 Cum 9456.26 94562.61
Total of the Sub-Head - Concrete W ork : 242930.27
Sub-Head : Reinforced Cement Concrete
Digitally signed by PRIYA
Description of Item Quantity unit Rate (Rs) Amount(Rs)
5.3 Reinforced cement concrete work in beams, suspended 25.00 Cum 12314.34 307858.42
floors, roofs having slope up to 15 ° landings, balconies,
shelves, chajjas, lintels, bands, plain window sills,
staircases and spiral stair cases above plinth level up to
floor five level, excluding the cost of centering, shuttering,
finishing and reinforcement with 1:1.5:3 (1 cement : 1.5
coarse sand(zone-III)derived from natural sources : 3
graded stone aggregate 20 mm nominal size derived from
natural sources).
5.9 Centering and shuttering including strutting, propping etc.
and removal of form for :
5.9.4 Shelves (Cast in situ) 105.00 Sqm 992.44 104205.75
5.9.21 Lintels, beams, plinth beams, girders, bressumers and 40.00 Sqm 901.14 36045.56
cantilevers with water proof ply 12 mm thick
5.22A Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in position and
binding all complete above plinth level.
5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or 3091.31 Kg 115.43 356835.65
5.30 Add for plaster drip course/ groove in plastered surface or 120.00 m 83.91 10069.38
moulding to R.C.C. projections
5.33 Providing and laying in position ready mixed or site
batched design mix cement concrete for reinforced
cement concrete work; using coarse aggregate and fine
aggregate derived from natural sources, Portland
Pozzolana/ Ordinary Portland/ Portland Slag cement,
admixtures in recommended proportions as per IS: 9103
to accelerate/ retard setting of concrete, to improve
durability and workability without impairing strength;
including pumping of concrete to site of laying, curing,
carriage for all leads; but excluding the cost of centering,
shuttering, finishing and reinforcement as per direction of
the engineer-in-charge; for the following grades of
Note: Extra cement up to 10% of the minimum specified
cement content in design mix shall be payable separately.
In case the cement content in design mix is more than
110% of the specified minimum cement content, the
contractor shall have discretion to either re-design the
mix or bear the cost of extra cement
5.33.2 All works above plinth level upto floor V level
5.33.2.1 Concrete of M25 grade with minimum cement content of 7.00 Cum 10553.59 73875.10
Total of the Sub-Head - Reinforced Cement Concrete : 888889.86
Sub-Head : Masonry Work
6.1 Brick work with common burnt clay F.P.S. (non modular)
bricks of class designation 7.5 in foundation and plinth in:
6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) 5.00 Cum 7633.65 38168.24
6.4 Brick work with common burnt clay F.P.S. (non modular)
bricks of class designation 7.5 in superstructure above
plinth level up to floor V level in all shapes and sizes in :
6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand) 270.00 Cum 9746.10 2631446.54
6.13 Half brick masonry with common burnt clay F.P.S. (non
modular) bricks of class designation 7.5 in superstructure
above plinth level up to floor V level.
6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) 250.00 Sqm 1202.80 300700.79
6.15 Extra for providing and placing in position 2 Nos 6mm dia. 250.00 Sqm 112.17 28041.86
M.S. bars at every third course of half brick masonry.ird
course of half brick masonry.
Total of the Sub-Head - Masonry W ork : 2998357.42
Sub-Head : Cladding Work
Digitally signed by PRIYA
Description of Item Quantity unit Rate (Rs) Amount(Rs)
8.2 Providing and fixing 18 mm thick gang saw cut, mirror
polished, premoulded and prepolished, machine cut for
kitchen platforms, vanity counters, window sills, facias
and similar locations of required size, approved shade,
colour and texture laid over 20 mm thick base cement
mortar 1:4 (1 cement : 4 coarse sand), joints treated with
white cement, mixed with matching pigment, epoxy touch
ups, including rubbing, curing, moulding and polishing to
edges to give high gloss finish etc. complete at all levels.
8.2.2 Granite stone slab colour black, Cherry/Ruby red
8.2.2.1 Area of slab upto 0.50 sqm 20.00 Sqm 5794.07 115881.38
8.3 Providing edge moulding to 18 mm thick marble stone
counters, Vanities etc., including machine polishing to
edge to give high gloss finish etc. complete as per design
approved by Engineer-in-Charge.
8.4 Extra for fixing marble /granite stone, over and above 25.00 m 608.52 15212.98
corresponding basic item, in facia and drops of width upto
150 mm with epoxy resin based adhesive, including
cleaning etc. complete.
8.5 Extra for providing opening of required size & shape for 33.00 No. 1047.50 34567.59
wash basin/kitchen sink in kitchen platform, vanity
counter and similar location in marble/ Granite/ stone
work, including necessary holes for pillar taps etc.
including moulding, rubbing and polishing of cut edges
8.31 Providing and fixing Ist quality ceramic glazed wall tiles 450.00 Sqm 1357.09 610689.10
conforming to IS: 15622 (thickness to be specified by the
manufacturer), of approved make, in all colours, shades
except burgundy, bottle green, black of any size as
approved by Engineer-in-Charge, in skirting, risers of steps
and dados, over 12 mm thick bed of cement mortar 1:3 (1
cement : 3 coarse sand) and jointing with grey cement
slurry @ 3.3kg per sqm, including pointing in white
cement mixed with pigment of matching shade complete.
8.32 Designing, fabricating, testing, installing and fixing in 10.00 Sqm 5367.61 53676.08
position Curtain Wall with Aluminium Composite Panel
Cladding, with open grooves for linear as well as
curvilinear portions of the building , for all heights and all
levels etc. including:
Total of the Sub-Head - Cladding W ork : 846433.22
Sub-Head : Wood and P.V.C. Work
9.1 Providing wood work in frames of doors, windows,
clerestory windows and other frames, wrought framed
and fixed in position with hold fast lugs or with dash
fasteners of required dia & length (hold fast lugs or dash
fastener shall be paid for separately).
9.3 Providing wood work in frames of false ceiling, partitions
etc. sawn and fixed in position with necessary stainless
steel screws etc.
9.3.2 Kiln seasoned and chemically treated hollock wood. 3.61 Cum 76352.90 275633.97
9.21 Providing and fixing ISI marked flush door shutters
conforming to IS : 2202 (Part I) non-decorative type, core
of block board construction with frame of 1st class hard
wood and well matched commercial 3 ply veneering with
vertical grains or cross bands and face veneers on both
faces of shutters:
9.21.1 35 mm thick including ISI marked Stainless Steel butt 155.00 Sqm 2560.85 396932.26
hinges with necessary screws
9.23 Extra for providing lipping with 2nd class teak wood 155.00 Sqm 494.85 76702.25
battens 25 mm minimum depth on all edges of flush door
shutters (over all area of door shutter to be measured).
Digitally signed by PRIYA
Description of Item Quantity unit Rate (Rs) Amount(Rs)
9.40 Providing and fixing wooden moulded beading to door
and window frames with iron screws, plugs and priming
coat on unexposed surface etc. complete :
9.40.1 2nd class teak wood
9.74 Providing and fixing bright finished brass tower bolts
(barrel type) with necessary screws etc. complete :
9.75 Providing and fixing bright finished brass door latch with
necessary screws etc. complete :
9.76 Providing and fixing bright finished brass 100 mm mortice 63.00 No. 914.73 57628.11
latch and lock with 6 levers and a pair of lever handles of
approved quality with necessary screws etc. complete.
9.82 Providing and fixing bright finished brass hanging type 63.00 No. 130.20 8202.73
floor door stopper with necessary screws, etc. complete.
9.100 Providing and fixing aluminium handles ISI marked,
anodised (anodic coating not less than grade AC 10 as per
IS : 1868) transparent or dyed to required colour or shade
with necessary screws etc. complete :
9.118 Providing and fixing to existing door frames.
9.118.1 24 mm thick factory made PVC door shutters made of 20.16 Sqm 3177.99 64068.24
styles and rails of a uPVC hollow section of size 59x24 mm
and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on
both sides. The styles and rails mitred and joint at the
corners by means of M.S. galvanised/plastic brackets of
size 75x220 mm having wall thickness 1.0 mm and
stainless steel screws. The styles of the shutter reinforced
by inserting galvanised M.S. tube of size 20x20 mm and 1
mm (± 0.1 mm) wall thickness. The lock rail made up of ‘H’
section, a uPVC hollow section of size 100x24 mm and 2
mm (± 0.2 mm) wall thickness, fixed to the shutter styles
by means of plastic/galvanised M.S. ‘U’ cleats. The shutter
frame filled with a uPVC multi-chambered single panel of
size not less than 620 mm, having over all thickness of 20
mm and 1 mm (± 0.1 mm) wall thickness. The panels filled
vertically and tie bar at two places by inserting
horizontally 6 mm galvanised M.S. rod and fastened with
nuts and washers, complete as per manufacturer ’ s
specification and direction of Engineer-in-charge. (For
W.C. and bathroom door shutter).
9.127 Providing & Fixing decorative high pressure laminated
sheet of plain / wood grain in gloss / matt / suede finish
with high density protective surface layer and reverse side
of adhesive bonding quality conforming to IS : 2046 Type
S, including cost of adhesive of approved quality.
9.140 Providing and fixing plain lining with necessary
screws/nuts & bolts/nails including a coat of approved
primer on one face and fixed on wooden /steel frame
work, complete as per direction of Engineer-in-charge.
(Frame work shall be paid for separately)
9.140.1 12mm thick commercial ply conforming to IS : 1328 BWR 250.00 Sqm 1310.74 327685.72
Digitally signed by PRIYA
Description of Item Quantity unit Rate (Rs) Amount(Rs)
9.168 Providing and fixing cuboard shutter with 19 mm thick 20.00 Sqm 3028.15 60562.93
one side decorative and other side balancing lamination
factory pressed BWP grade marine ply as per IS 710 of
approved brand including 2 mm thick PVC edege banding
tape with hot glue by edege bending machine etc. with
auto closing spring loaded hinges (hydraulic type) etc.
complete as per direction of Engineer-in-charge.
(Payment of providing and fixing auto closing hinges shall
be paid separately)
9.169 Providing and fixing 19 mm thick both side balancing 51.00 Sqm 2775.45 141547.87
lamination factory pressed BWP grade marine ply as per
IS 710 of approved brand boxes, shelves, racks, almirah,
cupboard and drawer etc. including necessary nails,
screws etc. complete as per direction of Engineer-in-
9.170 Providing and fixing stainless steel fancy handle of
approved make fixed with SS screws etc. complete as per
direction of Engineer-in-charge.
9.171 Providing and fixing stainless steel soft closing spring 80.00 No. 291.12 23289.73
hinges at 0 degree hinges (hydrarlic type) of approved
make/brand to cupboard shutters with full threaded steel
screws including making necessary recess in board and
finished etc. complete as per direction of Engineer-in-
9.174 Providing and fixing 2 mm thick 16 to 19 mm wide PVC 100.00 m 46.88 4687.91
edge binding tape of approved quality for
cuboard/wardrobe shutters including necessary synthetic
resin hot pressed to edges on binding machine etc.
complete as per direction of Engineer-in-charge.
Total of the Sub-Head - W ood And P.V.C W ork : 2320752.05
Sub-Head : Steel Work
Structural steel work riveted, bolted or welded in built up
sections, trusses and framed work, including cutting,
hoisting, fixing in position and applying a priming coat of
approved steel primer all complete.
10.3 Providing and fixing in position collapsible steel shutters 17.00 Sqm 12243.80 208144.67
with vertical channels 20x10x2 mm and braced with flat
iron diagonals 20x5 mm size, with top and bottom rail of
T-iron 40x40x6 mm, with 40 mm dia steel pulleys,
complete with bolts, nuts, locking arrangement, stoppers,
handles, including applying a priming coat of approved
10.25 Steel work welded in built up sections/ framed work,
including cutting, hoisting, fixing in position and applying a
priming coat of approved steel primer using structural
steel etc. as required.
10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, 100.00 Kg 184.73 18473.38
gates and similar works.
10.27 Providing and fixing carbon steel galvanised (minimum
coating 5 micron) dash fastener of 10 mm dia double
threaded 6.8 grade (yield strength 480 N/mm2), counter
sunk head, comprising of 10 mm dia polyamide PA 6
grade sleeve, including drilling of hole in frame , concrete/
masonry, etc. as per direction of Engineer-in-charge.
Digitally signed by PRIYA
Description of Item Quantity unit Rate (Rs) Amount(Rs)
10.28 Providing and fixing stainless steel ( Grade 304) railing 450.00 Kg 826.70 372014.87
made of Hollow tubes, channels, plates etc., including
welding, grinding, buffing, polishing and making curvature
(wherever required) and fitting the same with necessary
stainless steel nuts and bolts complete, i/c fixing the
railing with necessary accessories & stainless steel dash
fasteners , stainless steel bolts etc., of required size, on
the top of the floor or the side of waist slab with suitable
arrangement as per approval of Engineer-in charge, (for
payment purpose only weight of stainless steel members
shall be considered excluding fixing accessories such as
nuts, bolts, fasteners etc.).
Total of the Sub-Head - Steel W ork : 980944.08
Sub-Head : Flooring
11.3 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand
: 4 graded stone aggregate) finished with a floating coat of
neat cement, including cement slurry, but excluding the
cost of nosing of steps etc. complete.
11.3.1 40 mm thick with 20 mm nominal size stone aggregate 50.00 Sqm 657.38 32868.91
11.6 Cement plaster skirting up to 30 cm height, with cement
mortar 1:3 (1 cement : 3 coarse sand), finished with a
floating coat of neat cement.
11.24 Extra for pre finished nosing to treads of steps of marble / 20.00 m 770.51 15410.18
11.25 Extra for marble / granite stone flooring in treads of steps 10.00 Sqm 911.68 9116.82
and risers using single length up to 2.00 metre .
11.26 Kota stone slab flooring over 20 mm (average) thick base
laid over and jointed with grey cement slurry mixed with
pigment to match the shade of the slab including rubbing
and polishing complete with base of cement mortar 1 : 4
(1 cement : 4 coarse sand) :
11.41A Providing and laying Vitrified tiles in floor in different sizes
(thickness to be specified by the manufacturer) with
water absorption less than 0.08% and conforming to
IS:15622, of approved brand & manufacturer, in all
colours and shade, laid on 20 mm thick cement mortar
1:4 (1 cement: 4 coarse sand) jointing with grey cement
slurry @3.3 kg/sqm including grouting the joints with
white cement and matching pigments etc. The tiles must
be cut with the zero chipping diamond cutter only . Laying
of tiles will be done with the notch trowel, plier, wedge,
clips of required thickness, leveling system and rubber
mallet for placing the tiles gently and easily.
11.41A.1 Double charge vitrified tile polished finish of size
11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size
11.55 Providing and laying flamed finish Granite stone flooring
in required design and patterns, in linear as well as
curvilinear portions of the building all complete as per the
architectural drawings with 18 mm thick stone slab over
20 mm (average) thick base of cement mortar 1:4 (1
cement : 4 coarse sand) laid and jointed with cement
slurry and pointing with white cement slurry admixed
with pigment of matching shade including rubbing, curing
and polishing etc. all complete as specified and as directed
by the Engineer-in-Charge :
11.55.1 Flamed finish granite stone slab Jet Black, Cherry Red, 50.00 Sqm 3410.73 170536.25
Elite Brown, Cat Eye or equivalent.
Digitally signed by PRIYA
Description of Item Quantity unit Rate (Rs) Amount(Rs)
11.56 Providing and laying Polished Granite stone flooring in
required design and patterns, in linear as well as
curvilinear portions of the building all complete as per the
architectural drawings with 18 mm thick stone slab over
20 mm (average) thick base of cement mortar 1:4 (1
cement : 4 coarse sand) laid and jointed with cement
slurry and pointing with white cement slurry admixed
with pigment of matching shade including rubbing , curing
and polishing etc. all complete as specified and as directed
by the Engineer-in-Charge.
11.56.1 Polished Granite stone slab jet Black, Cherry Red, Elite 22.00 Sqm 4796.34 105519.38
Brown, Cat Eye or equivalent
11.56.2 Polished Granite stone slab of all colour and texture 22.00 Sqm 3286.94 72312.79
except Black, Cherry/Ruby Red
Total of the Sub-Head - Flooring : 2380823.43
Sub-Head : Roofing
12.21 Providing gola 75x75 mm in cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 stone aggregate 10 mm and
down gauge), including finishing with cement mortar 1:3
(1 cement : 3 fine sand) as per standard design :
12.22 Making khurras 45x45 cm with average minimum 12.00 No. 319.22 3830.60
thickness of5 cm cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate of 20 mm nominal
size) over P.V.C. sheet 1 m x1 m x 400 micron, finished
with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand)
and a coat of neat cement, rounding the edges and
making and finishing the outlet complete.
12.45 Providing and fixing false ceiling at all height including
providing and fixing of frame work made of special
sections, power pressed from M.S. sheets and galvanized
with zinc coating of 120 gms/sqm (both side inclusive) as
per IS : 277 and consisting of angle cleats of size 25 mm
wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at
1200 mm centre to centre, one flange fixed to the ceiling
with dash fastener 12.5 mm dia x 50 mm long with 6 mm
dia bolts, other flange of cleat fixed to the angle hangers
of 25x10x0.50 mm of required length with nuts & bolts of
required size and other end of angle hanger fixed with
intermediate G.I. channels 45x15x0.9 mm running at the
spacing of 1200 mm centre to centre, to which the ceiling
section 0.5 mm thick bottom wedge of 80 mm with
tapered flanges of 26 mm each having lips of 10.5 mm, at
450 mm centre to centre,
Digitally signed by PRIYA
Description of Item Quantity unit Rate (Rs) Amount(Rs)
shall be fixed in a direction perpendicular to G.I.
intermediate channel with connecting clips made out of
2.64 mm dia x 230 mm long G.I. wire at every junction,
including fixing perimeter channels 0.5 mm thick 27 mm
high having flanges of 20 mm and 30 mm long, the
perimeter of ceiling fixed to wall/partition with the help of
rawl plugs at 450 mm centre, with 25mm long dry wall
screws @ 230 mm interval, including fixing of gypsum
board to ceiling section and perimeter channel with the
help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c,
including jointing and finishing to a flush finish of tapered
and square edges of the board with recommended
jointing compound , jointing tapes , finishing with jointing
compound in 3 layers covering upto 150 mm on both
sides of joint and two coats of primer suitable for board,
all as per manufacturer's specification and also including
the cost of making openings for light fittings, grills,
diffusers, cutouts made with frame of perimeter channels
suitably fixed, all complete as per drawings, specification
and direction of the Engineer in Charge but excluding the
cost of painting with :
12.45.1 12.5 mm thick tapered edge gypsum plain board 1400.00 Sqm 1451.11 2031557.84
conforming to IS: 2095- (Part I) : 2011 (Board with BIS
certification marks)
Total of the Sub-Head - Roofing : 2071967.87
Sub-Head : Finishing
13.1 12 mm cement plaster of mix :
13.2 15 mm cement plaster on the rough side of single or half
brick wall of mix :
13.11 18 mm cement plaster in two coats under layer 12 mm 220.00 Sqm 555.00 122100.89
thick cement plaster 1:5 (1 cement: 5 coarse sand)
finished with a top layer 6mm thick cement plaster 1:6 (1
cement: 6 fine sand).
13.16 6 mm cement plaster of mix :
13.22 Extra for plastering exterior walls of height more than 10 80.00 Sqm 93.22 7457.85
m from ground level for every additional height of 3 m or
13.80 Providing and applying white cement based putty of 4400.00 Sqm 167.02 734889.39
average thickness 1 mm, of approved brand and
manufacturer, over the plastered wall surface to prepare
the surface even and smooth complete.
13.85 Applying priming coats with primer of approved brand
and manufacture, having low VOC (Volatile Organic
Compound ) content.
13.85.3 With water thinnable cement primer on wall surface 4400.00 Sqm 79.15 348254.21
having VOC content less than 50 grams/litre.
13.83 Wall painting with premium acrylic emulsion paint of
interior grade, having VOC (Volatile Organic Compound )
content less than 50 grams/ litre. of approved brand and
manufacture, including applying additional coats
wherever required to achieve even shade and colour.
13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm 100.00 Sqm 171.89 17189.02
over and including priming coat of exterior primer applied
@ 0.90 litre/10 sqm)
13.47 Finishing walls with Premium Acrylic Smooth exterior
paint with Silicone additives of required shade
13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm 100.00 Sqm 183.13 18312.83
over and including priming coat of exterior primer applied
@ 0.90 litre/10 sqm)
Digitally signed by PRIYA
Description of Item Quantity unit Rate (Rs) Amount(Rs)
13.61 Painting with synthetic enamel paint of approved brand
and manufacture to give an even shade :
13.61.1 Two or more coats on new work. 150.00 Sqm 166.86 25028.97
13.88 Removing white or colour wash by scrapping and sand 1000.00 Sqm 21.14 21138.43
papering and preparing the surface smooth including
necessary repairs to scratches etc. complete
13.116 Polishing in high gloss/matt finish melamine clear polish 25.00 Sqm 3264.25 81606.36
on wood work in required color/wooden shade texture
with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper
80/120 no. and then with sand paper of 160/180 nos.
2. Applying two coats of sealer with spray gun and
allowing sufficient drying time for 1st coat and 2nd coat is
allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth
of finer grading with water to remove excess sealer layer
and make the surface further smooth after this wet
rubbing, then surface is applied with special grade
melamine fillers to fill all the small and big holes/grooves
etc. Filler coat to be allowed to dry for 4 to 6 hrs on which
again a light wet rubbing is done this surface is further
allowed to dry for 12 hrs.
4. On this, 1st coat of melamine polish is applied with
spray gun using melamine clear polish and melamine
thinner in required proportion. This 1st coat is allowed to
dry for 24 hrs then this dry surface is again fine wet
rubbed smooth, which is further allowed to dry for 12 hrs.
The final melamine polish is applied with compressor
pressure spray gun using melamine clear polish and
melamine thinner mixed in required proportion complete
as per direction of Engineer-in-Charge. (Finalo coat to be
done in 1 or 2 layers without gap of time.)
14.1 Repairs to plaster of thickness 12 mm to 20 mm in
patches of area 2.5 sq.meters and under, including cutting
the patch in proper shape, raking out joints and preparing
and plastering the surface of the walls complete, including
disposal of rubbish to the dumping ground, all complete
as per direction of Engineer-in-harge.
14.1.1 With cement mortar 1:4 (1 cement : 4 fine sand). 660.00 Sqm 585.88 386682.27
Providing and fixing double scaffolding system (cup lock
type) on the exterior side, up to seven story height made
with 40 mm dia M.S. tube 1.5 m centre to centre,
horizontal & vertical tubes joining with cup & lock system
with M.S. tubes, M.S. tube challies, M.S. clamps and M.S.
staircase system in the scaffolding for working platform
etc. and maintaining it in a serviceable condition for the
required duration as approved and removing it there
after. The scaffolding system shall be stiffened with
14.72 bracings, runners, connection with the building etc 500.00 Sqm 362.03
wherever required for inspectionof work at required
locations with essential safety features for the workmen
etc. complete as per directions and approval of Engineer-
in-charge. The elevational area of the scaffolding shall be
measured for payment purpose. The payment shall be
made once irrespective of duration of scaffolding.Note: -
This item to be used for maintenance work judicially,
necessary deduction for scaffolding in the existing item to
Digitally signed by PRIYA
Description of Item Quantity unit Rate (Rs) Amount(Rs)
Providing & fixing White vitreous china water closet
squatting pan (Indian type) along with "S" or "P" trap
including dismantling of old WC seat and "S" or "P" trap at
14.80 site complete with all operations including all necessary
materials, labour and disposal of dismantled material i/c
malba, all complete as per the direction of Engineer-in
14.80.1 Long pattern W.C Pan of size 580x440 mm 5.00 No. 3747.87 18739.35
14.80.2 Orissa pattern W.C Pan of size 580x440 mm 2.00 No. 4793.61 9587.21
Dismantling W.C. Pan of all sizes including disposal of 2152.91
14.82 dismantled materials i/c malba all complete as per 15.00 No. 143.53
directions of Engineer-in- Charge.
Taking out existing wooden door shutter, repair by
cutting, painting etc. and refixing of repaired door
14.85 shutters to existing door frames, including replacement of 10.00 No. 459.27
hinges with screws, etc. as required, all complete as per
the direction of the Engineer-in-charge.
15.2 Demolishing cement concrete manually/ by mechanical
means including disposal of material within 50 metres
lead as per direction of Engineer - in - charge.
15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent 5.00 Cum 2605.38 13026.89
15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalent 5.00 Cum 1609.30 8046.52
15.3 Demolishing R.C.C. work manually/ by mechanical means 5.00 Cum 3800.90 19004.51
including stacking of steel bars and disposal of
unserviceable material within 50 metres lead as per
direction of Engineer - in- charge.
15.7 Demolishing brick work manually/ by mechanical means
including stacking of serviceable material and disposal of
unserviceable material within 50 metres lead as per
direction of Engineer-in-charge..
15.7.4 In cement mortar 100.00 Cum 2205.03 220503.21
15.12 Dismantling doors, windows and clerestory windows
(steel or wood) shutter including chowkhats, architrave,
holdfasts etc. complete and stacking within 50 metres
15.12.1 Of area 3 sq. metres and below 55.00 No. 393.01 21615.78
Dismantling steel work in built up sections in angles, tees, 302359.75
flats and channels including all gusset plates, bolts, nuts,
cutting rivets, welding etc. including dismembering and
stacking within 50 metres lead.
15.23 Dismantling tile work in walls, floors and roofs laid in
cement mortar including stacking material within 50
15.23.1 For thickness of tiles 10 mm to 25 mm 300 Sqm 78.56002 23568.01
15.45 Dismantling C.I. pipes including excavation and refilling
trenches after taking out the pipes, manually/ by
mechanical means breaking lead caulked joints, melting of
lead and making into blocks including stacking of pipes &
lead at site within 50 metre lead as per direction of
Engineer-in-charge:
15.56 Dismantling old plaster or skirting raking out joints and 1000.00 Sqm 58.49 58491.90
cleaning the surface for plaster including disposal of
rubbish to the dumping ground within 50 metres lead.
15.57 Dismantling aluminium/ Gypsum partitions, doors, 500.00 Sqm 60.31 30155.70
windows, fixed glazing and false ceiling including disposal
of unserviceable material and stacking of serviceable
material with in 50 meters lead as directed by Engineer-
Digitally signed by PRIYA
Description of Item Quantity unit Rate (Rs) Amount(Rs)
15.60 Disposal of building rubbish / malba / similar 200.00 Cum 282.51 56501.14
unserviceable, dismantled or waste materials by
mechanical means, including loading, transporting,
unloading to approved municipal dumping ground or as
approved by Engineer-in-charge, beyond 50 m initial lead,
for all leads including all lifts involved.
Total of the Sub-Head - Finishing : 4213540.18
Sub-Head : Aluminium Work
21.1 Providing and fixing aluminium work for doors, windows,
ventilators and partitions with extruded built up standard
tubular sections/appropriate Z sections and other sections
of approved make conforming to IS: 733 and IS: 1285,
fixing with dash fasteners of required dia and size,
including necessary filling up the gaps at junctions, i.e. at
top, bottom and sides with required EPDM
rubber/neoprene gasket etc. Aluminium sections shall be
smooth, rust free, straight, mitred and jointed
mechanically wherever required including cleat angle,
Aluminium snap beading for glazing / paneling, C.P. brass/
stainless steel screws, all complete as per architectural
drawings and the directions of Engineer-in-charge.
(Glazing, paneling and dash fasteners to be paid for
21.1.1 For fixed portion
21.1.1.2 Powder coated aluminium (minimum thickness of powder 600.00 Kg 568.22 340933.36
coating 50 micron)
21.1.2 For shutters of doors, windows & ventilators including
providing and fixing hinges/ pivots and making provision
for fixing of fittings wherever required including the cost
of EPDM rubber / neoprene gasket required (Fittings shall
be paid for separately).
21.1.2.2 Powder coated aluminium (minimum thickness of powder 600.00 Kg 679.05 407431.10
coating 50 micron)
21.3 Providing and fixing glazing in aluminium door, window,
ventilator shutters and partitions etc. with EPDM rubber /
neoprene gasket etc. complete as per the architectural
drawings and the directions of engineer-in-charge . (Cost
of aluminium snap beading shall be paid in basic item):
21.3.3 With float glass panes of 8 mm thickness (weight not less 300.00 Sqm 1803.88 541165.09
than 20 kg/sqm)
21.8 Filling the gap in between aluminium frame & adjacent
RCC/ Brick/ Stone work by providing weather silicon
sealant over backer rod of approved quality as per
architectural drawings and direction of Engineer-in-charge
21.8.1 Upto 5mm depth and 5 mm width 500.00 m 103.55 51775.76
21.11 Providing and fixing stainless steel (SS 304 grade)
adjustable friction windows stays of approved quality with
necessary stainless steel screws etc. to the side hung
windows as per direction of Engineer-in-charge complete.
21.15 Providing and fixing aluminium casement windows
fastener of required length for aluminium windows with
necessary screws etc. complete.
21.15.2 Powder coated minimum thickness 50 micron aluminium. 102.00 No. 104.84 10693.26
Total of the Sub-Head - Aluminium W ork : 1389586.01
Sub-Head : Water Proofing
22.3 Providing and laying water proofing treatment to vertical
and horizontal surfaces of depressed portions of W.C.,
kitchen and the like consisting of:
Digitally signed by PRIYA
Description of Item Quantity unit Rate (Rs) Amount(Rs)
(i) Ist course of applying cement slurry @ 4.4 kg/sqm
mixed with water proofing compound conforming to IS
2645 in recommended proportions including rounding off
junction of vertical and horizontal surface.
(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3
coarse sand) mixed with water proofing compound in
recommended proportion including rounding off junction
of vertical and horizontal surface.
(iii) IIIrd course of applying blown or residual bitumen
applied hot at 1.7 kg. per sqm of area.
(iv) IVth course of 400 micron thick PVC sheet. (Overlaps 150.00 Sqm 823.70 123555.43
at joints of PVC sheet should be 100 mm wide and pasted
to each other with bitumen @ 1.7 kg/sqm).
Total of the Sub-Head - W ater Proofing : 123555.43
Sub-Head : New Technologies and Materials
26.28 Chipping of unsound/weak concrete material from slabs,
beams, columns etc. with manual Chisel and/ or by
standard power driven percussion type or of approved
make including tapering of all edges, making square
shoulders of cavities including cleaning the exposed
concrete surface and reinforcement with wire brushes
etc. and disposal of debris for all lead and lifts all
complete as per direction of Engineer-In-Charge
26.28.1 75 mm average thickness 150.00 Sqm 404.57 60686.01
26.29 Cleaning of reinforcement from rust from the reinforcing
bars to give it a total rust free steel surface by using
alkaline chemical rust remover of approved make with
paint brush and removing loose particles after 24 hours of
its application with wire brush and thoroughly washing
with water and allowing it to dry, all complete as per
direction of Engineer-In-Charge.
26.29.1 Bars upto 12 mm diameter 300.00 m 8.83 2648.99
26.29.2 Bars above 12 mm diameter 200.00 m 17.61 3521.29
26.31.2 Epoxy bonding adhesive having coverage 2.20 sqm/kg of 75.00 Sqm 305.25 22893.72
Total of the Sub-Head - New Technologies And Materials : 89750.01
15 Sub-Head : Non Schedule Items
MR Providing & fixing Vista DS Opaque 3ply PVC+1 Ply fiber
glass blackout fabric series or equivalent in 100mm
vertical blinds having Head Rail: Head rail is of 25mm high
and 47 mm wide Extruded High strength aluminum alloy
section with Average wall thickness of minimum 0.9mm.
The section is anodized for smooth operations and has
the provision of Fabric valance matching with louvers
fabric. End Control Unit (Reduction Gear Box): End control
unit state of art reduction gear box having the reduction
ratio of 3.5:1 for a very smooth operation of the blind.
This unit Consists of a planetary gear in the outer housing,
four small transmission gears fitted in the middle
assembly and an end receiving gear attached to central
sprocket unit. Tilt Rod: It is made of extruded aluminum
having three keyways. The tilt rod is fixed in the end
control unit and drives the carrier gear mechanism to
rotate the louvers. The average diameter is 5.8mm to
achieve minimum torsion deflection Tilter Chain: This is
made of 4.5 mm plastic beads molded on 1.5 mm thick
polyester cord. The Pitch of the beads is 6mm. The chain
drives the procket fixed in the end control unit to rotate
the louvers by 180 degrees.
Digitally signed by PRIYA
Description of Item Quantity unit Rate (Rs) Amount(Rs)
The pitch of the chain corresponds to the sprocket in
perfect match for trouble free Operation. It is provided in
white color. Carrier (Runner): This is a molded component
having anti friction additive. It consists of polymer
Housing with wheels mounted on sides and has a gear and
worm mechanism with vertical worm fixed With a
tongued poly carbonate stem to hold the louvers. The
worm and gear mechanism are driven by Tilt rod fixed to
end control unit to rotate louvers by 180 degrees. The
mounted wheels on sides of Casing move on rails of head
rail section for resistance free stacking of louvers Spacer:
This is made of molded High Polymer ABS, having anti
friction additive. It maintains proper Spacing of the
runners and ensures overlapping of louvers for perfect
light control. It is available in 100 mm size. Installation
Bracket: This is made of galvanized steel “ L ” bracket of
thickness 3mm which is fitted with Pressure clip made of
spring steel to hold the head-rail. Cord Weight: This is
made of ABS material hollow casing with a steel weight
Cord: It is 2.2mm in diameter, Nylon braided high strength 220.00 Sqm 4222.00 928840.00
cord having maximum abrasion resistance & Minimum
elongation. Bottom Mechanism (Weight and Chain): The
purpose of this is to keep the louver straight & prevent
them from swaying.
•The bottom weight is made of FILLED PP and is having
provision for fixing bottom chain. Available in 100 mm.
• Bottom weight is fixed with U- type of clips attached
at equal distance on Polyester cord having 0.8mm dia
with molded plastic beads on it.
MR Providing and fixing machine cut, mirror/ eggshell
polished, Granite stone work for wall lining (veneer work),
including dado, skirting risers of steps etc. in required
design and pattern wherever required stone of different
finished surface texture, on 12mm average thick cement
mortar 1:3 (1 cement : 3 coarse sand) laid and joined with
white cement slurry @ 3.3kg/sqm including pointing with
white cement slurry admixed with pigment of matching
shade, including rubbing curing, polishing etc. All
complete as per Architectural designs and as direction by
Engineer-in-charge.
Area of slab over 0.50 sqm
18mm thick Granite of all colour except black, cherry/ruby 11.94 Sqm 7121.00 85024.74
18mm thick Granite of colour black, cherry/ruby red 11.94 Sqm 8592.00 102588.48
Digitally signed by PRIYA
Description of Item Quantity unit Rate (Rs) Amount(Rs)
M.R.2 Constructing Brick masonry percolation pit 3m dia and 5m 1.00 Each 541195.00 541195.00
deep with bricks of class designation 7.5 in cement mortar
1:6, base concrete 1:4:8 below the brick wall, including
cost of necessary excavation in any type of soil, back
filling as required in 20cm thick layers, dewatering if any,
shuttering and shoring and disposal of surplus excavated
material within 2 nos. 300mm dia borings to a depth of 9
metre (to be measured from the bottom of the
percolation pit), provisioning and fixing 160mm O.D. PVC
pipes, tested to 6kg/sqcm, in each bore and upto the
height of 300mm above the RCC top slab. The PVC pipe
shall be slotted except 3.0 metres at the top and 3.0
metres below from the bottom of the percolation pit,
which shall be blind. Top of the PVC pipe shall be covered
with PVC Socket & plug. Each bore around the PVC pipe
shall be filled with pea gravels. The percolation pit shall be
filled with river stone/pebbles as shown in drawing. The
top slab shall be 150mm thick with RCC M20 including
nominal reinforcement and 2 nos. of 560mm internal dia
SFRC manhole covers with frames conforming to
Total of the 1657648.22
Digitally signed by PRIYA
Name of Project: D-WING PROJECT BUILDING , BOKARO STEEL PLANT
1 SUBHEAD-I(Sanitary Fixtures & CP Brass Fittings) 3,18,826.05 32,326.00
2 SUBHEAD II(Soil, Waste, Vent & Rain Water Pipes) - 11,70,874.45
3 SUBHEAD III(Water Supply System(Internal)) 4,48,407.93 94,624.50
4 SUBHEAD IV(External Sewerage & Storm Water Drainage) 3,51,153.76 96,440.00
5 SUBHEAD V(External Water Supply) 42,839.45 -
GRAND TOTAL 25,55,492.15
GRAND TOTAL 25,55,492.15
Digitally signed by PRIYA
Name of Project: D-WING PROJECT BUILDING , BOKARO STEEL PLANT
PLUMBING WORKS DETAILED ESTIMATE
S.I DSR MR MR DSR
Description of Item Unit QUANTITY
No Item No Item No Rate Amount Rate Amount
SUBHEAD-I(Sanitary Fixtures & CP Brass Fittings)
1 17.3 MR 1 Providing and fixing white vitreous china pedestal type water
closet (European type) with seat and lid, 10 litre low level
white vitreous china flushing cistern & C.P. flush bend with
fittings & C.I. brackets, 40 mm flush bend, overflow
arrangement with specials of standard make and mosquito
proof coupling of approved municipal design complete,
including painting of fittings and brackets, cutting and making
good the walls and floors wherever required :
1.1 17.3.2 MR 1.1 W.C. pan with ISI marked black solid plastic seat and lid Each 14 8,427.86 117990.0861
2 17.7 MR 2 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. -
brass pillar taps, 32 mm C.P. brass waste of standard pattern,
including painting of fittings and brackets, cutting and making
good the walls wherever require:
2.1 17.7.2 MR 2.1 White Vitreous China Wash basin size 630x450 mm with a Each 17 2,382.86 40508.66089
single 15 mm C.P. brass pillar tap
3 17.22A MR 3 Providing and fixing CP Brass 32 mm size Bottle Trap of Each 17 1,107.55 18828.28948
approved quality & make and as per the direction of Engineer-
4 17.10 MR 4 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen -
sink as per IS:13983 with C.I. brackets and stainless steel plug
40 mm, including painting of fittings and brackets, cutting and
making good the walls wherever required:
4.1 17.10.1 MR 4.1 Kitchen sink with drain board -
5 MR 5 Fixing of 15 mm C.P brass wall mounted mixing fittings Each
swinging spout for sink complete including cutting and 1 5388.00 5388 -
making good the walls where required. (Pantry, Kitchen,
Coffee-Break etc.)
6 17.4 MR 6 Providing and fixing white vitreous china flat back or wall -
corner type lipped front urinal basin of 430x260x350 mm and
340x410x265 mm sizes respectively with automatic flushing
cistern with standard flush pipe and C.P. brass spreaders with
brass unions and G.I clamps complete, including painting of
fittings and brackets, cutting and making good the walls and
floors wherever required :
6.1 17.4.1 MR 6.1 One urinal basin with 5 litre white P.V.C. automatic flushing Each 10 6,698.74 66987.40125
7 MR 7 Providing and fixing in postion storage type automatic electric -
water heater pressure type thermostatically controlled, single
phase wall mounted of approved make (to the approval of
Engineer-in-charge) with thermostats, inner container of
stainless steel, Inner glass lining with B-Rating minimum 3
stars complete with 1 Mtr. three core flexible cord with plug,
non return valve and pressure release valve complete
including fixing and testing complete in all respect.
Vertical type -
7.1 MR 7.1 15 litre capacity water heater Each 1 13470.00 13470 -
8 MR 8 Providing & fixing in position Water Cooler without Stablizer -
of approved make (to the approval of Engineer-in-charge )
including carriage complete in all respect.
8.1 MR 8.1 Each 0
Water Cooler Full Steel Body 40 ltr Capacity without Stablizer
9 17.16A MR 9 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube Each 14 373.70 5231.73343
upto 1 metre long with S.S. triangular plate to Eureopean type
W.C. of quality and make as approved by Engineer - in -
10 18.53 MR 10 Providing and fixing C.P. brass angle valve for basin mixer and Each 45 614.67 27660.29805
geyser points of approved quality conforming to IS:8931
11 17.28 MR 11 Providing and fixing P.V.C. waste pipe for sink or wash basin -
Digitally signed by PRIYA
11.1 17.28.2 MR 11.1 Flexible pipe -
12 MR 12 Providing & Fixing in position C.P. Brass coat hook of -
approved make (to the approval of Engineer-in-charge ) fixed
into wall with C.P. brass screws and rawl plugs etc. complete in
12.1 MR 12.1 C.P.Brass coat hook Each 14 962.00 13468 -
13 17.31 MR 13 Providing and fixing 600x900 mm beveled edge mirror of Each 17 1,720.99 29256.81105
superior glass (of approved quality) complete with 6 mm thick
hard board ground fixed to wooden cleats with C.P. brass
screws and washers complete.
14 17.72 MR 14 Providing and fixing PTMT towel ring trapezoidal shape 215 Each 7 248.26 1737.792595
mm long, 200 mm wide with minimum distances of 37 mm
from wall face with concealed fittings arrangement of
approved quality and colour, weighing not less than 88 gms.
15 17.71 MR 15 Providing and fixing PTMT liquid soap container 109 mm Each 17 180.19 3063.145085
wide, 125 mm high and 112 mm distance from wall of
standard shape with bracket of the same materials with snap
fittings of approved quality and colour, weighing not less than
SUBHEAD II(Soil, Waste, Vent & Rain Water Pipes) -
16 MR 1 Supply, installation , testing commissioning of PP Mineral
filled low noise Soil & Waste system as per EN 12056,
with density 1.9 g/cm3. PP mineral(Astolan) filled Low
noise system should has a fire classification DIN 4102-
B2/EN13501 . Product should have a chemical resistance
of pH 2-12 and is a complete sound protection system
according to DIN 4109. including with push fit rubber ring
sockets all necessary fittings and specials such as Bends,
junctions, offsets & vent cowl. Fixing at wall/ceiling level
supported by rubber line bracket & hangers etc. duly epoxy
coated. Cutting, chases/holes in floors / walls /
slab.Compliant with LABC. Weight mass per unit area of
DN100MM should not be less than 110.07kg/m3. sound
levels of not more than 15dBA as per EN 14366 at a flow
rate of 4 l/s.including all core cut ,chases ,cutting making
holes in all wall and floor as required complete in all
17 MR 2 Providing fixing, testing and commissioning in position Solfit
SWR uPVC PIPE TYPE-B pipe comforming to IS:13592
including all fittings such as bends, junctions, inspection doors,
offests, cowl, access pieces/clean out plugs, clamps /supports/
hangers etc. jointing with PVC Adhesive joints including cutting
holes in walls, core cutting in slabs and making good the same.
All complete as per specification and direction of E/l.(For
rainwater piping) -
18 MR 3 Providing Fixing straight /offset type single body push fit type WC
pan connector with factory supplied spring loaded seal
guard with integral single mould sealing fins made of
flexible EVA body, including bush/adaptor as supplied with
the pan connector (if required). Each 14 800.00 11200 -
19 MR 4 Providing and fixing floor drain (FD) with 50mm/40mm outlet
and one 40mm inlet for waste, with SS grating (adjustable
height), having 50mm water seal and in-built NRV
20 MR 5 Providing and fixing PP/UPVC trap of self cleansing design with
screwed down or hinged grating with or without vent arm complete,
including cost of cutting and making good the walls and floors :
20.1 MR 5.1 100 mm inlet and 100 mm outlet -
20.1.1 MR 5.1.1 Sand cast iron S&S as per IS: 3989 Each 20 3986.29 79725.89977 -
21 MR 6 Providing and fixing PP/UPVC grating with Cockroach proof
strainer of approved design including setting in floor with
cement motor to match with floor finish as per architect
requirement suitable for waster and FT. -
Digitally signed by PRIYA
22 MR 7 Providing and fixing PP/UPVC brass grating with frame of
approved design including setting in floor with cement motor
to match with floor finish as per architect requirement.
23 MR 8 Providing and fixing PP/UPVC extention piece for 100 mm dia
floor trap formed out of main pipe with multiple side inlets,
suitable for various dia pipes including all fixtures as required
complete as per drawing approved sample and direction of
engineer in charge. Each 20 2508.45 50168.98083 -
24 MR 9 Providing and fixing cast PP floor clean out plug with
suitable insert keys for opening, male threaded joint with
threaded socket drip seal to soil / waste pipe as required
complete as per drawing approved sample and direction of
engineer in charge. Each 8 1769.53 14156.20855 -
25 MR 10 Providing and fixing rainwater khurra epoxy coated cast
iron body outlet with flat grate on balconies & terrace as
required complete as per drawing approved sample and
direction of engineer in charge. -
SUBHEAD III(Water Supply System(Internal)) -
26 18.8 MR 1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)
pipes, having thermal stability for hot & cold water supply,
including all CPVC plain & brass threaded fittings and fixing the
pipe with clamps at 1.00 m spacing. This includes jointing of
pipes & fittings with one step CPVC solvent cement and the
cost of cutting chases and making good the same including
testing of joints complete as per direction of Engineer in
Concealed work, including cutting chases and making good
the walls etc(inside building) -
26.5 MR 1.5 50 mm nominal dia Pipes Mtr 10 1074.25 10742.5 -
27 18.7 MR 2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)
pipes, having thermal stability for hot & cold water supply and
all CPVC plain & brass threaded fittings, including fixing the
pipe with clamps at 1.00 m spacing. This includes jointing of
pipes & fittings with one step CPVC solvent cement and testing
of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall(vertical & terrace area) -
27.2 18.7.3 MR 1.2 25 mm nominal dia Pipes Mtr 20 429.78 8595.5793
27.5 MR 1.5 65 mm nominal dia Pipes Mtr 20 1925.1 38502 -
27.6 MR 1.6 80 mm nominal dia Pipes Mtr 10 2490.9 24909 -
28 18.18 MR 3 Providing and fixing ball valve (brass) of approved quality, -
High or low pressure, with plastic floats complete :
28.1 18.18.1 MR 3.1 15 mm nominal dia Pipes Each 10 435.45 4354.52
28.2 18.18.2 MR 3.2 20 mm nominal dia Pipes Each 7 495.01 3465.10
28.3 18.18.3 MR 3.3 25 mm nominal dia Pipes Each 5 496.67 2483.36
29 18.17 MR 4 Providing and fixing gun metal gate valve with C.I. wheel of
approved quality (screwed end) : -
30 MR 5 Providing and fixing Butter fly valve with nitrile seat and
stainless steel stem with lever operation and cast iron body
in powder coated finish, suitable for test pressure of
10Kg/sq.mm) with flanges, gaskets and necessary pad
locking arrangement complete required. -
Digitally signed by PRIYA
31 MR 6 Providing and fixing thermal insulation in cold/hot water -
pipes a Polyolefin foam of closed cell structure having
thermal conductivity of 0.036 W/M.K at an average
temperature of 30oC. complete with 24 gauge aluminium
sheet/cladding.
31.1 MR 6.1 15 mm dia pipe RM 0 45 -
31.9 Providing and placing on terrace (at all floor levels) LTR 20000 11.77
polyethylene water storage tank, IS : 12701 marked, with
18.48 cover and suitable locking arrangement and making necessary
holes for inlet, outlet and overflow pipes but without fittings
and the base support for tank. 235466.00
Digitally signed by PRIYA
SUBHEAD IV(External Sewerage & Storm Water Drainage) -
32 MR 1 Excavation in trenches with straight or open cutting in streets,
lanes or in open area with 3D/JCB or excavator including
manually dressing bed, trimming sides and side slopes for
sewers and manholes to full depths as shown in
drawings,including, dressing to correct sections and
dewatering, provision for diversion for traffic, protection of
existing services i.e. telephone cables, electric lines, water
supply lines and gas lines etc. night signals, profiles, pegs, sight
rails, boning rods, watching, etc., fixing and maintenance of
caution boards, fencing, refilling trenches, watering, ramming
and restoration of surface to original level and removal of
surplus spoil from the site of works, upto one chain (15m)
complete in all respects
32.1 MR 1.1 Depth not exceeding 3 m. BGL -
All kinds of soil except rocky Mtr 200 224 44800 -
33 MR 2 Excavation of trenches in a Streets, Lanes or in Open Area for
Storm Sewers and Manholes to Full Depths as Shown in
Drawings,excluding Shoring, Timbering of Poling Board Frame
System Type, dressing to correct sections and dewatering,
provision for diversion for traffic, protection of existing
services i.e. telephone cables ,electric lines, water supply lines
and gas lines.night signals, profiles, Pegs, Sight rails, boning
rods, crossing over trenches for access to the houses,
watching, fencing etc., fixing and maintenance of caution
boards, refilling trenches, watering of refill in 15 cm layers,
ramming and restoration of surface to original conditions and
removal of Surplus Spoil from the Site of Works, for all Works
other than connections to Ventilating Shafts upto a Lead of 15
33.1 MR 2.1 For depth not exceeding 2 m. below Ground level -
All classes of soil except rocky Mtr 110 224 24640 -
34 19.6 MR 3 Providing and laying non-pressure NP2 class (light duty) R.C.C.
pipes with collars jointed with stiff mixture of cement mortar in the
proportion of 1:2 (1 cement : 2 fine sand) including testing of joints
etc. complete : -
Providing, laying and jointing glazed stoneware pipes class SP-1
with stiff mixture of cement mortar in the proportion of 1:1 (1
cement : 1 fine sand) including testing of joints etc. complete : -
36 19.7 MR 5 Constructing brick masonry manhole in cement mortar 1:4 ( 1
cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1
cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20
mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4
coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal
size), inside plastering 12 mm thick with cement mortar 1:3 (1
cement : 3 coarse sand) finished with floating coat of neat cement
and making channels in cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size)
finished with a floating coat of neat cement complete as per
standard design :
36.1 19.7.1 MR 5.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with
frame (light duty) 455x610 mm internal dimensions, total weight of
cover and frame to be not less than 38 kg (weight of cover 23 kg
and weight of frame 15 kg) : -
36.2 19.7.1.2 MR 5.1.2 With Sewer bricks conforming to IS : 4885 Each 12 13,605.44 163265.2745
37 19.4 MR 6 Providing and fixing square-mouth S.W. gully trap class SP-1
complete with C.I. grating brick masonry chamber with water tight
C.I. cover with frame of 300 x 300 mm size (inside) the weight of
cover to be not less than 4.50 kg and frame to be not less than
2.70 kg as per standard design: -
37.2 19.4.1.1 MR 6.1.1 With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 Each 6 2,898.00 17387.98677
38 MR 7 Constructing catch basin 45x45 cm with bricks in cement
mortar 1:4 (1 cement : 4 coarse sand) including 500x450
mm pre-cast R.C.C. horizontal grating with frame complete
as per standard design : -
38.2 MR 7.1 With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 Each 6 4500 27000 -
Digitally signed by PRIYA
Providing orange colour safety foot rest of minimum 6 mm thick
plastic encapsulated as per IS : 10910, on 12 mm dia steel bar
conforming to IS: 1786, having minimum cross section as 23
mmx25 mm and over all minimum length 263 mm and width as
165 mm with minimum 112 mm space between protruded legs
having 2 mm tread on top surface by ribbing or chequering
besides necessary and adequate anchoring projections on tail
length on 138 mm as per standard drawing and suitable to with
stand the bend test and chemical resistance test as per
specifications and having manufacture’s permanent identification
mark to be visible even after fixing, including fixing in manholes
with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3
coarse sand : 6 graded stone aggregate 20 mm nominal size)
complete as per design. Each 36 592.63 21334.50396
40 19.21 MR 9 Making connection of drain or sewer line with existing
manhole including breaking into and making good the walls, floors
with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size) cement plastered on
both sides with cement mortar 1:3 (1 cement : 3 coarse sand),
finished with a floating coat of neat cement and making necessary
channels for the drain etc. complete :
40.1 19.21.1 MR 9.1 For pipes 100 to 250 mm diameter Each 2 867.42 1734.84927
SUBHEAD V(External Water Supply) -
41 18.12 MR 1 Providing and fixing G.I. pipes complete with G.I. fittings including
trenching and refilling etc. -
External work -
42 18.40 MR 2 Painting G.I. pipes and fittings with two coats of anti-corrosive
bitumastic paint of approved quality : - 0
43 18.14 MR 3 Fixing water meter and stop cock in G.I. pipe line including
cutting and threading the pipe and making long screws etc.
complete (cost of water meter and stop cock to be paid
separately). Each 1 869.40 869.40469
44 18.37 MR 3 Constructing masonry Chamber 60x45x50 cm inside, in brick
work in cement mortar 1:4 (1 cement : 4 coarse sand) for water
meter complete with C.I. double flap surface box 400x200x200
mm (inside) with locking arrangement and RCC top slab 1:1.5:3
mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20
mm nominal size), including necessary excavation, foundation
concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone
aggregate 40 mm nominal size) and inside plastering with cement
mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a
floating coat of neat cement complete as per standard design :
Digitally signed by PRIYA
ENGINEERING CONSULTANCY SERVICES
(SCHEDULE OF QUANTITIES)
NAME OF WORK: Cost Estimate for Renovation and conversion of D Block (Ground Floor) of Administrative Building
into Projects office building
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
A SCHEDULE ITEMS
WIRING AND SUB MAINS
Wiring for light point/ fan point/ exhaust fan point/ call bell
point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable in surface / recessed heavy
1 1.3.3 class Steel conduit, with modular switch, modular plate, Point 360 2,042.44 735277.55
suitable GI box and earthing the point with 1.5 sq.mm.
FRLS PVC insulated copper conductor single core cable
etc as required.a) Group C
Wiring for twin control light point with 1.5 sq.mm FRLS
PVC insulated copper conductor single core cable in
surface / recessed Steel conduit, 2 way modular switch,
modular plate, suitable GI box and earthing the point with
1.5 sq.mm. FRLS PVC insulated copper conductor single
core cable etc as required
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC
insulated copper conductor single core cable in surface/
3 1.5 recessed Steel conduit alongwith 1 No 4 sq. mm FRLS Point 1120 479.34 536856.67
PVC insulated copper conductor single core cable for loop
earthing as required
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC
insulated copper conductor single core cable in surface/
4 1.6 recessed Steel conduit alongwith 2 Nos 4 sq. mm FRLS metre 10 732.84 7328.42
PVC insulated copper conductor single core cable for loop
earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with
the following sizes of FRLS PVC insulated copper
conductor, single core cable in surface/ recessed Steel
conduit as required.
b 1.7.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire metre 1000 473.80 473801.25
b 1.7.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire metre 969 652.03 631810.77
d 1.7.5 2 X 10 sq. mm + 1 X 6 sq. mm earth wire metre 5 785.98 3929.89
e 1.7.9 4 X 6 sq. mm + 2 X 6 sq. mm earth wire metre 120 1,022.88 122745.52
f 1.7.10 4 X 10 sq. mm + 2 X 6 sq. mm earth wire metre 60 1,290.78 77446.58
g 1.7.11 4 X 16 sq. mm + 2 X 6 sq. mm earth wire metre 50 1,821.04 91051.76
Supplying and fixing suitable size GI box with modular
plate and cover in front on surface or in recess, including
5 1.31 providing and fixing 3 pin 5/6 amps modular socket outlet Each 56 528.04 29570.51
and 5/6 amps modular switch, connection etc. as required.
(For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular
plate and cover in front on surface or in recess, including
6 1.32 providing and fixing 6 pin 15/16 amps modular socket Each 42 648.71 27245.79
outlet and 15/16 amps modular switch, connection etc. as
Supplying and fixing of following modular switch/ socket
7 outlet on the existing Modular plate & switch including -
connection but excluding modular plate etc. as required.
b 1.24.4 3 pin 5/6 amp socket outlet Each 56 135.06 7563.11
d 1.24.5 6 pin 15/16 amp socket outlet Each 42 218.08 9159.42
Supplying and fixing following size/ modules, GI box
Boxes alongwith modular base & cover plate for modular
switches in recess etc as required.
a 1.27.1 1 or 2 Module (75mmX75mm) Each 2 329.89 659.78
ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
2.18 Supplying and fixing 20 amps, 240 volts, SPN industrial
type, socket outlet, with 2 pole and earth, metal
enclosed plug top along with 20 amps "C" curve, SP,
9 MCB, in sheet steel enclosure, on surface or in recess, Each 1 1,794.47 1794.47
with chained metal cover for the socket out let and
complete with connections, testing and commissioning
etc. as required.
1.25 Supplying and fixing stepped fan regulator on the existing
10 modular plate switch box including connections but Nos. 15 408.49 6127.31
excluding modular plate etc. as required.
Supplying and fixing of modular Blanking plate on the
11 1.26 existing modular plate & switch box excluding modular Each 100 44.28 4428.05
plate etc. as reqd.
TELEPHONE / TV -
1.24 Supply and fixing following modular switch/socket on the
12 existing modular plate and cover plate & switch box -
including connections but excluding modular plate etc. as
a 1.24.6 Telephone socket outlet. (RJ - 11) Each 49 163.84 8028.05
b 1.24.7 TV antenna socket outlet Each 1 163.84 163.84
1.27 Supplying and fixing following size/modules, GI box along
13 with modular base and cover plate for modular switches in -
recess etc as required.
1.18 Supplying and drawing following pair, 0.5 sq.mm FR PVC
15 insulated copper conductor, unarmoured telephone cable -
in the existing surface / recessed steel / PVC conduit as
1.27.1 Supply, laying, testing and commissioning of the following
16 co-axial PVC insulated conductor cable in existing -
surface / recessed conduit etc. and including making
terminal joints, complete as required.
1.53 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in
17 the existing surface/ recessed Steel/ PVC conduit/ -
raceway as required.
ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
Supplying and fixing of following sizes of steel conduit
along with accessories in surface/recess including painting
in case of surface conduit, or cutting the wall and making
good the same in case of recessed conduit as required.
Supplying and fixing of following sizes of heavy class PVC
conduit along with accessories in surface/recess including
cutting the wall and making good the same in case of
recessed conduit as required.
DISTRIBUTION BOARDS -
Supplying and fixing following way, Horizontal type three
pole and neutral, sheet steel, MCB distribution board, 415
volts, on surface/recess, complete with tinned copper bus
bar, neutral bus bar, interconnections, powder painted
including earthing etc. as required. (But without
MCB/RCCB/Isolator)
a 2.4.1 4 way (4 + 12), Double door, Horizontal Each 1 4,528.79 4528.79
b 2.4.2 6 way (4 + 18) ,Double door, Horizontal Each 8 5,506.28 44050.23
c 2.4.3 8 way (4 + 24), Double door, Horizontal Each 1 6,605.54 6605.54
Supplying and fixing following rating, four pole, 415 volts,
21 2.13 isolator in the existing MCB DB complete with -
connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, (single
phase and neutral), 240 volts, residual current circuit
22 2.14 breaker (RCCB), having a sensitivity current upto 30 -
milliamperes in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA,
"C" curve, miniature circuit breaker suitable for inductive
23 2.10 load of following poles in the existing MCB DB complete -
with connections, testing and commissioning etc. as
a 2.10.1 Single pole Each 120 283.40 34007.42
Supplying and fixing single pole blanking plate in the
existing MCB DB complete etc. as required.
ERRECTION OF FAN & FIXTURE -
Installation ,Testing, Commissioning of wall bracket fittings
of all sizes and shapes including LED lamps per fitting,
complete with all accessories including connections etc.
Installation, testing and commissioning of pre-wired,
fluorescent fitting / compact fluorescent fitting / LED
Fittings of all types, with all accessories and tube
etc. directly on ceiling/ wall, including connection with
1.5 sq. mm FR PVC insulated, copper conductor, single
core cable and earthing etc. as required.
ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
Supply, Installation, Testing and Commissioning of 1200
mm sweep, BEE 5 star rated, ceiling fan with Brush Less
Direct Current (BLDC) Motor, class of insulation: B, 3 nos.
blades, 30 cm long down rod, 2 nos. canopies, shackle kit,
safety rope, copper winding, Power Factor
not less than 0.9, Service Value (CM/M/W) minimum 6.00,
27 19.1 Air delivery minimum 210 Cum/Min , 350 RPM (tolerance each 5 3,022.14 15110.72
as per IS : 374-2019), THD less than 10%, remote or
electronic regulator unit for speed control and all
remaining accessories including safety pin, nut bolts,
washers, temperature rise=75 degree C (max.), insulation
resistance more than 2 mega ohm, suitable for 230 V, 50
Hz, single phase AC Supply, earthing etc. complete as
Installation of exhaust fan in the existing opening,
28 1.5 including making good the damage, connection, -
testing, commissioning etc. as required.
Extra for fixing the louvers/ shutters complete with frame
for a exhaust fan of all sizes.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia
including accessories, and providing masonry enclosure
30 5.2 with cover plate having locking arrangement and watering Nos. 2 7,588.57 15177.14
pipe etc. with charcoal/coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm
including accessories, and providing masonry enclosure
cover plate having locking arrangement and watering pipe
2.7 metre long etc. with charcoal/ coke and salt as
Earthing with copper earth plate 600 mm X 600 mm X 3
thick including accessories, and providing masonry
with cover plate having locking arrangement and watering
of 2.7 metre long etc. with charcoal/ coke and salt as
Providing and fixing 25 mm X 5 mm G.I. strip on surface
or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm Copper. strip on
surface or in recess for connections etc. as required.
5.18 Providing and fixing 6 SWG dia G.I. wire on surface or in
35 recess for loop earthing along with existing surface/ Mtr 150 46.49 6974.18
recessed conduit/ submain wiring/ cable as required
6.2 Providing and fixing of lightning conductor finial, made of
36 25 mm dia 300 mm long, G.I. tube, having single prong at Nos. 2 573.43 1146.86
top, with 85 mm dia 6 mm thick G.I. base plate including
holes etc. complete as required.
6.7 Providing and fixing G.I. tape 20 mm X 3 mm thick on
37 parapet or on surface of wall for lightning conductor and Mtr 200 139.48 27896.71
external lighting complete as required. (For Horizontal run)
6.8 Providing and fixing G.I. tape 20 mm X 3 mm thick on
38 parapet or on surface of wall for lightning conductor Mtr 60 218.08 13084.88
complete as required. (For vertical run)
ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
6.12 Providing and fixing testing joint, made of 20 mm X 3 mm
39 thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, Set 2 133.95 267.90
nuts, chuck nuts and spring washers etc. complete as
INTELLIGENT FIRE DETECTION AND ALARM SYSTEM -
17.2.1 Supplying, installation, testing and commissioning of micro
processor based intelligent addressable main fire alarm
panel, central processing unit with the following loop
modules and capable of supporting not less than 240
devices (including detectors) and minimum 120 detectors
per loop and loop length up to 2 km, network
communication card, minimum 320 character graphics/
LCD display with touch screen or other keypad and
minimum 4000 events history log
40 in the non volatile memory (EPROM), power supply unit -
(230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed
maintenance free batteries with automatic charger. The
panel shall have facility to connect printer to printout log
and facility to have seamless integration with
analog/digital voice evacuation system (which is part of
the schedule of work under SH: PA System) and shall be
complete with all accessories . The panel shall be
compatible for IBMS system with open protocol BACnet/
Modbus over IP complete as per
17.2.2 Supplying, installation, testing & commissioning of central
41 graphical fire alarm management system to centrally Each 1 2,22,078.84 222078.84
monitor and operate the fire alarm system complete as
17.2.3 Supplying, installation, testing & commissioning of
42 repeater panel wih 320 character/ Touch screen LCD Each 1 1,20,318.95 120318.95
display with inbuilt reset, acknowledge and silence
switches complete as required.
17.2.9 Supplying, installation, testing & commissioning of
intelligent addressable thermal detector with rate of rise
cum fixed tempreature thermistor complete with base as
17.2.4 Supplying, installation, testing & commissioning of
44 intelligent analog addressable photothermal detector Each 117 3,163.84 370169.40
complete with mounting base complete as required.
17.2.13 Supplying, installation, testing & commissioning of
45 intelligent addressable duct detector including suitable Each 1 8,650.19 8650.19
Photo detector complete with base as required
17.2.5 Supplying, installation, testing & commissioning of
46 response indicator on surface/recessed MS Box having Each 41 305.54 12526.95
two LED, metallic cover complete with all connections etc
17.2.14 Supplying, installation, testing & commissioning of
addressable manual call point complete as required.
17.2.15 Supplying, installation, testing & commissioning of
addressable horn cum strobe complete as required.
17.2.7 Supplying, installation, testing & commissioning of fault
isolator complete with base as required.
17.2.10 Supplying, installation, testing & commissioning of
addressable fire control module complete as required
17.2.11 Supplying, installation, testing & commissioning of
51 addressable phone control module complete as required. Each 3 3,616.61 10849.83
17.2.17 Supplying, installation, testing & commissioning of fire
fighter telephone handset complete as required.
ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
17.5.2 Supplying & laying of 2x1.5 sqmm fire alarm armoured
53 cable, 600/1000V rated with annealed copper conductor Each 2835 191.51 542939.70
having XLPE insulation, steel wire armouring & FRLS
outer sheath complete as required.
Supplying, installation, testing & commissioning of 6 zone,
voice alarm controller with USB, MP3 player (including 6
54 17.3.1 zone button paging station) with seamless integration Each 1 1,39,938.53 139938.53
facility with main fire alarm panel for voice evacuation
complete as required.
Supplying, installation, testing & commissioning of
1.5/3/6W ceiling speaker complete as required.
Supplying, installation, testing & commissioning of
56 17.3.3 1.5/3/6W metal box ceiling/wall speakers complete as Each 2 1,984.87 3969.75
Supplying, installation, testing & commissioning of
57 17.3.4 ceiling/wall mounted loud speaker, 3/1.5 Watt in ABS Each 3 2,687.83 8063.48
enclosure complete as required.
Supplying, installation, testing & commissioning of 6
inches dia, 2 watts, 70/100 volts ceiling speaker complete
Supplying, installation, testing & commissioning of digital
59 17.3.6 audio amplifier 50 Watt, 25V rms operating at 240 volt AC Each 3 1,07,135.54 321406.62
supply complete as required.
Supplying, installation, testing & commissioning of digital
60 17.3.7 audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Each 1 1,61,394.64 161394.64
Supply complete as required.
Supplying, installation, testing & commissioning of Voice
61 17.3.9 command keypad 6 zone, with microphone assembly Each 1 90,504.89 90504.89
complete as required.
Supplying and drawing of cable Fire Retardant PVC
insulated copper conductor cable in the existing surface /
62 17.5.3 recessed steel conduit of following pairs, cores and size -
including connections and interconnections etc. as
a 17.5.3.2 speaker cable Two pair, 2-core, 1.5 sqmm meter 5 98.52 492.62
b 17.5.3.3 speaker cable Three pair, 2-core, 1.5 sqmm meter 1890 136.16 257347.14
c 17.5.3.4 speaker cable Four pair, 2-core, 1.5 sqmm meter 50 174.91 8745.40
Cable End Termination & Pipes -
Supplying and making ends termination with brass
compression glands and aluminium lugs for following size
of PVC insulated PVC sheathed aluminiumconductor
cable of 1.1 KV grade as required .
Providing, laying and jointing PVC/RCC NP-2 pipe with
Vin stiff mixture of cement mortar in the proportion of 1:2
(1 cement:2 fine sand) including trenching
64 (75 cm deep / or as required) i/c testing the joints etc. in -
loose soil/under the flooring (before laying the finished
flooring) for electrical cable entrance to the building
complete as required i/c excavation and refilling of earth.
ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
Supplying and laying of following size DWC HDPE pipe
ISI marked along with all accessories like socket, bend,
couplers etc. conforming to IS 14930, Part II complete with
fitting and cutting, jointing etc.direct in ground (75 cm
below ground level) including
excavation and refilling the trench but excluding sand
cushioning and protective covering etc., complete as
a 14.16.1 63 mm dia (OD-63 mm & ID-51 mm nominal) metre 100 273.43 27343.20
b 14.16.2 90 mm dia (OD-90 mm & ID-76 mm nominal) metre 5 321.03 1605.17
c 14.16.3 120 mm dia (OD-120 mm & ID-103 mm nominal) metre 5 407.38 2036.90
d 14.16.4 160 mm dia (OD-160 mm & ID-135 mm nominal) metre 80 532.47 42597.83
e 14.16.5 200 mm dia (OD-200 mm & ID-175 mm nominal) metre 5 739.48 3697.42
ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
B NON SCHEDULE ITEMS
DATA /TELEPHONE / EPBX
Supply and fixing following modular switch/socket on the
66 existing modular plate and cover plate & switch box
including connections but excluding modular plate etc. as
Information Socket Outlet RJ -45 suitable for CAT 6 Data
WI FI AND NETWORKING
Supply & Installation of Dual Face Plates along with
67 clearly printed labels and holders complete as required Each 2 250.00 500.00
and as per technical specifications.
Supply & Installation of Single Face Plates along with
68 clearly printed labels and holders complete as required Each 55 225.00 12375.00
and as per technical specifications.
SITC of light fixtures suitable for LED fixture, lamps with
all components and accessories including but not
69 restricted to reflectors, housings, lamp holders and
including cost of ballasts and cost of lamps complete as
required and as below Make:-Bajaj,Havells,Polycab or
20W LED Tube light of Havells Cat Ref:
LUMILINESMART20WLED865PCWH or equivalent.
Recessed mounted 20 W Downlighter of Havells Cat
Ref:Havells GLOWDLR15WLED830S or equivalent.
Recessed mounted 18 W Downlighter of Havells Cat
Ref:Havells GLOWDLR15WLED830S or equivalent.
Surface mounted 18W LED Downlighter of Havells Cat
b Ref:Havells EDGESURFACERDDLR18WLED840S or Nos. 32 2,778.00 88896.00
28/30 W, 2x2 Panel recess mounting luminaire . of
d Havells Cat Ref: PLANO2X2PLR30WLED840SG2, or Nos. 26 7,039.00 183014.00
15W Mirror Light of Havells Cat Ref:
LUMILINEXS17WLED865SPCWH or equivalent.
10W LED Bulk Head of Havells Cat Ref:
e RUGBYGENXFTS10WLED865SSYMBOPC or Nos. 3 1,528.00 4584.00
Supplying of under note sizes of heavy duty exhaust
fans complete with fan motor, blades fixing frame, louver
etc as required of havells makes or equivalent.
Supplying and fixing of 16 SWG M.S. Fan Box 12.5" Rod
but without fan cover (hylam sheet). as required.
Supplying and fixing of fan cover (hylam sheet).on the
existing Fan Box as required.
450 mm exhaust fan 900 RPM Each 8 2,968.00 23744.00
Supply, installation, testing and commissioning of 2 kVA
Inverter with alongwith lithium ion battery giving a
back up of min. 30 min. at full load as per specification
alongwith all accessories including interconnecting cables,
lugs, Base Frames, Battery Rack & Battery Circuit
breaker, palral kit complete as required.
AUDIO VIDEO SYSTEM (Conference Hall )
ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
Supply installation testig and commissioning of LG
Interactive Display - 86", LG - 86TR3DJ
Brightness : 390 nit (w/o Glass, Typ.)
Multi Touch Point : 20 Points (Max.)
Interface : HDMI (3), RGB (1), Audio In (1), RS-232C In
(1), RJ45 (1), USB 3.0 Type A (3), USB 2.0 Type A (3),
Audio Out / Optical Output, Touch USB (2)
Supply installation testig and commissioning of POP
75 Display - for chairman Each 1 65,000.00 65000.00
Supply installation testig and commissioning of Video
Conferencing Solution
Supports sharp video quality of up to 4K Full-HD video
output, Runs on Android 9.0 operating system, Remote
76 video screen real[1]time control and sharing PC screen Each 1 2,18,000.00 218000.00
functions, Advanced camera with 8M pixel CMOS sensor,
FOV wide-angle lens, 12x zoom and PTZ for easy camera
view adjustments
Supply installation testig and commissioning of
Capacitive touch mute button with LED, 1500mA built-in
Li-Ion battery, Micro-B port for charging, BYOD
77 microphone and upgrading, Low power indicator, Each 28 53,000.00 1484000.00
Bluetooth v2.1+EDR protocols, Proprietary 2.4GHz
wireless technology with dynamic beamforming
Supply installation testig and commissioning of Audio
Audiotrak 120W Class D RMS Mixer Amplifier
2x MIC, 1xLine, 1xEMC, 2xAUX & 4x Phonejack MIC
Input, Rack Mount
Approved Makes - Audiotrak / Barco / Honeywell / Bosch
Supply installation testig and commissioning of CENTRAL
UNIT (CONTROLLER) : Support eight meeting modes:
limited number, FIOFI, LIFO, Last in First out, Chairman's
79 permission (request for speech), voice control start, limited Each 1 2,11,000.00 211000.00
time speech, queuing speech, free discussion.
Approved Makes - Barco / Grandstream / Polycom /
Supply installation testig and commissioning of 6.5 inch
two way loudspeaker having driver size : 6.5'' + 1'', Rated
RMS Power: 40W and peak Power 110W at 8Ohm , RMS
Power Taps: 8 Ω /40W/20W/10W/ 5W, Line Voltage:
100V/70V/8Ω. Refquency Range from 70Hz - 16Khz.
Approved Makes - Bosch / Sonance / Philips /Stapes
Supply installation testig and commissioning of Digital
signal processor ; 08 AEC enabled Mic/Line inputs, 08
Line outputs or better , Input channel processing should
include Pre amplifier, Signal generator, Expander,
Compressor, 10 band Parametric EQ or better.
Approved Makes - Barco / Grandstream / Polycom
Supply installation testig and commissioning of Gold
82 Plated HDMI Cable Each 1 14,750.00 14750.00
Supply installation testig and commissioning of
Conference Room Automation Controller
( for Lighting, Screen, Blinds, and Hardware On / OFF
ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
Supply installation testig and commissioning of
84 Automation Relay module for Lighting - 2 channel Each 1 1,00,300.00 100300.00
Supply installation testig and commissioning of Lighting
85 Dimmer for Lighting / Blinds - 2 channel Each 1 1,23,900.00 123900.00
Supply installation testig and commissioning of
Automation Keypad
8/10 Buttons Keypad for Automation
Supply laying, testig and commissioning of Set Of Cables:
Speakers Cable, cat 6 cable & patch cable and all type of
wiring for conference systems
Supply installation testig and commissioning of Set Of
Connector and equipment rack:Set of various Connector
88 and other accessories and hardware and software as Lot 1 50,000.00 50000.00
required for Complete Setup
The BOQ shall be read in conjunction with general notes,
specification and equipment schedule and single line
Supply and installation of the following cubical type panels
( Partial Type tested ) made of 14 gauge CRCA structure,
base channel, doors & partitions complete with, Air Circuit
Breaker, moulded case circuit breakers, meters, indicating
lamps, current transformer etc. Complete in all respects,
insulated bus bars with heat shrinkable PVC sleeve in
suitable bus chambers, interconnection, small wiring,
name plate, danger plate, earth bus etc. & comprising of
compartments with hinged door for each feeder & its
accessories, cable alley with hinged doors, bus chamber
with bolted door etc. The panel being of dust & vermin
proof construction with rubber gasket, attractively powder
coated with Siemens grey shade and having orange peel
finish. The panel shall be free standing type/ wall mounted
type as per relevant drawing, Equipment schedule,
specifications including all materials, accessories, loose
supplied items, etc. required for completeness of the
project majorly comprising of following : -
ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
ACB shall have a rated operational voltage of 415V AC,
rated insulation voltage of 1000 volts AC, rated impulse
voltage of 12kV.ACB shall be Moulded Case design and
shall comply with standards IS/IEC 60947-1 & 2. with Ics =
Icu = Icw (1sec) = 50kA.
Both fixed & draw-out circuit breakers shall have single
pole-pitch. ACBs upto 3200A shall be provided with top
horizontal and bottom vertical terminal adapters on both
sides for proper cable connections/bus duct connections.
Shunt trip and closing coil (having common AC/DC supply
upto 250V) shall be continuous rated.
There Should be On, Off, Trip, Spring Charge and Ready
to close Indication lamp for all ACB on the panel door..
ACB trip unit shall be EMC/EMI tested and should have a
display for measurement of current and voltage. It shall be
possible to view last 5 trip cause on trip unit. Separately
powered, individual fault trip indication LEDs (For O/L,
S/C, E/F and trip unit failure) shall be available on the trip
unit which shall function even if the display fails.All ACB
shall be EMS compitable.
All MCCBS shall be with Extended type Front door
operating handle, Phase Spreaders & Phase Barriers
complying to IS/IEC 60947-1 & 2.
MCCBs shall be current limiting type preferably having an
encapsulated double break design, with rated operational
voltage (Ue) of 415V, insulation voltage (Ui) of 690 V (AC
50/60 Hz) & impulse voltage (Uimp) of not less than 8kV.
The electrical life of MCCBs shall be 8,000 operations up
to 250A & 4000 operations up to 630A and shall be of
single frame size upto 250A.Cable Termination on MCCB
should be done using circular lugs being fixed with a bolt
passing through.
For E/F in MCCBs wherever required , external earthfault
module with CBCT should be used with indication lamp on
the panel and fault sensitivity selection from 20% – 60%
In. and time delay selection in case of Earth Fault from 0.5
to 3 Sec/ instantaneous.All incomer MCCB should be with
E/F protection also.There Should be On, Off, Trip, and
electrical fault trip Indication lamp for all MCCB on the
panel door. Separate fault differentiation indication (LED)
for Over current and Earth fault. Indication for over current
and earth fault tripping shall be extended to the panel door
via indication lamps..All MCCB shall be EMS compitable.
All MCCBs of ratigs above 250A shall be microprocessor
based and upto 250A shall be Thermal Magnetic Type
and with Min 35 kA Rating .
ON, OFF, Trip and Ready to close status for each ACB
and ON, OFF Trip staus for all Incommer MCCB shall be
avilable on MODBUS.
Control Voltage for Closing / Tripping coils , Spring
charging motor & Indicting lamps in Manually / Electrically
operated ACB Feeder shall be 230 V AC/ DC.
Metering CTs burden shall be with suitable VA & accuracy
CTs shall be "CAST RESIN" type .
All indication lights shall be LED type.
All energy meter shall be "DIGITAL" type with Modbus
Protocol as per techncial Specification
ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
Panel Manufacturer should have Type Test Certificates for
Short Time withstand current test of 50KA for 1.0 Sec
from CPRI. Bhopal / Bangalore.
Control SP MCB's of 2A Rating shall be provided for each
metering circuit.
20% spare control terminal to be provided.
Live parts shall not be accessible after opening the door,
Transparent acrylic sheet to be provided to cover the
same & busbar joints section shall be covered with PVC
All bus bar shall be insulated with coloured PVC Sleeve
i.e. R, Y, B, BK as per colour code.
All internal control wiring shall be heat resistant type.
All TP/TPN feeders shall have solid isolable neutral link.
All starters shall be provided with Auto/ Manual selector
switch, MPCB/ MCCB/MCB, over load relay, single
phasing preventor, ON/OFF/ Trip/ Trip on Eclectrical
Fault indication lamps, ON/OFF push Buttons, contractor
and suitable No. of Potential free contacts for remote /
local operations, indication, interlocking and Building
Management system.
Current density for bus bar shall not be more than
0.8A/Sqmm. Rating of Bus bar is after considering all
derating factors. (Bus bar sizing calculation to be
submitted for approval.)
All TP/TPN feeders shall have solid isolable neutral link.
Bus couplers shall be provided with ON & OFF indicating
lights but without releases.
All feeders shall be provided with door interlocked with
door defeat, pad lock facility.
Spare contacts of Relays/Contactor etc. shall be wired
upto terminal block.
Degree of protection for following type of distribution panel
enclosure shall be as per IS:13947-1993.
IP 43 for indoor panels.
IP 55 for outdoor panels.
Contractor and panel builder shall have to submit the GA
drawing and get approval from consultant before
89 MAIN LT PANEL
2 No.320A, 4-pole MCCB
2 No.320A, 4-pole Contactor
Metering & Indication:
Multifunction digital meter with Class 0.5 active energy
Accuracy with Sag/Swell - Waveform capture and
Individual harmonics monitoring upto 63rd. Power Quality
analyser needs to be capable of Disturbance direction
detection with onboard ethernet Port communication.
Set of ON/OFF/Trip/Trip Circuit healthy/ready to close
Sets of phase indicating lamp with 2A control MCBs.
Auto trip indicating lamps protection by 2A Control MCB
All incomer with buscoupler shall be mechanically and
electrically interlock.Consider all necessary software and
hardware for proper functioning of interlocking.It shall
operate auto on and auto off of breaker and then auto on.
1 Nos.200A, 4P MCCB as Buscoupler
ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
500A, TPN aluminium, colour coded bus bars suitable for
415V, 50Hz with fully rated neutral.(After deration)
1 Nos.200A, TPN MCCB
2 Nos.100A, TPN MCCB
6 Nos.63A, TPN MCCB
7 Nos.40A, TPN MCCB
2 Nos. Bulb with holder
Panel shall be suitable for incoming & outgoing supply
with cables,and top / bottom entry as required.
2 No.63 A, TPN MCCB
1 No.63 A, 4P Bypass
Metering & Indication:
Combined Ammeter/Voltmeter with Selector Switch and
160/5A, CL-1, 10VA CTs and 2A control MCB.
Set of ON/OFF/Trip/Trip Circuit healthy/ready to close
Sets of phase indicating lamp with 2A control MCBs.
100A, copper busbar for R,Y,B and 200A for Neutral,
colour coded bus bars suitable for 415V, 50Hz with fully
rated neutral.(After deration)
4 Nos.32A, TPN MCCB
2 Nos.16A, TPN MCCB
2 Nos.16A, DP MCCB
2 Nos. Bulb with holder
Panel shall be suitable for incoming & outgoing supply
with cables,and top / bottom entry as required.
Supply & Laying of 1.1KV grade multicore aluminium
conductor XLPE insulated and PVC sheathed armoured
91 cable conforming to IS : 7098 (Part-I) 1998 along walls/ on
existing cable trays etc. in an approved manner and as
Cable End Termination & Pipes -
Supplying and making ends termination with brass
compression glands and aluminium lugs for following size
of PVC insulated PVC sheathed aluminiumconductor
cable of 1.1 KV grade as required .
Constructing Masonry chamber 60x60x75 cm (deep)
inside with 75 class designation FPS brick work in cement
mortar 1:4 (1 cement: 4 coarse sand) (for cable entry) with
10 mm thick M.S. hinged cover plate on top in 40 x 5 mm
93 MS angle iron frame embedded in C C 1:2:4 i/c each 4 7,500.00 30000.00
necessary excavation and inside plastering with cement
mortar 1:3 (1 cement:3 fine sand) finished with a floating
coat of neat cement complete as required and as per
specifications attached.
ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
Constructing masonry chamber 60 cm x 45 cm x 50 cm
(deep) inside with 75 class designation FPS brick work in
cement mortar 1:4 (1 cement : 3 coarse sand) (for cable
entry) with 10 mm thick M.S. hinged cover plate on top in
94 40 x 40 x 5 mm MS angle iron frame embedded in C C each 2 6,000.00 12000.00
1:2: 4i/c necessary excavation and inside plastering with
cement mortar 1:3 (1 cement:3 fine sand) finished with a
floating coat of neat cement complete as required and as
per specifications attached.
EXTERNAL LIGHTING
Supplying and fixing (with suitable MS clamp) 300mm
95 long 65mm dia MS pipe with base plate i/c nipple for each 2 3,384.00 6768.00
Supplying, installing, testing & commissioning of 4.5 Mtr
long single dip Galvanised steel octagonal poles
in 3mm sheet integrated connector box inside the
pole containing one no. 5A MCB , Neutral link and earth
terminal with single over hang bracket 1m long ;
providing and fixing in position 1:2:4 reinforced
cement concrete foundation for the pole, size
500mm(L)X500mm(W)X 1650mm deep i/c excavation of
earth, providing, cutting, bending and placing in position
reinforcement as per drawing and providing PVC
flexible pipes 50mm dia for cable entry and exit as
required i/c foundation bolts, transportation, handling,
marking etc. as per specification and drawings as required
of Havells/ Bajaj or equivalent
Supply and installation of following arms suitable for 4.5
Mtr to 9 mtr street light pole
a Single Arm over hang bracket 1mtr length each 12 3,384.00 40608.00
b Double Arm over hang bracket 1mtr length each 3 4,600.00 13800.00
Providing and erection of black painted galvanized 3
meter high poles in different section, top 60mm dia.,
bottom 100mm dia. with gold colour painted ornamental
cast aluminium ring having lockable weather proof flush
door junction box in bottom section, and suitable
arrangement for installation of CCTV and with base plate
dia. 290mm having 4 holes of 22mm dia. complete
erected in an approved manner including foundation of
Suitable size & type of foundation bolts as required. (For
supply & drawing 3 core 2.5 sqmm
unarmoured copper cable inside the GI
99 Octagonal pole from connector box to the light Set 15 1,083.00 16245.00
fixture including connections with thimbles as required
upto 9m high pole
Supplying and fixing (with suitable MS clamp) 1200mm
long vertically and 900mm inclined at 45 degree, 65mm
dia MS pipe with hardware i/c nipple for street
light.(boundary wall light)
ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
Supplying and fixing of LED Bollard Fitting 600mm High
with IP65 and IK07 Housing made up of aluminum pipe
powder coated black after phosphochromate treatment
with aluminum heat sink for effective thermal management
Complete with Mounting Brackets & accessories as
required with connections similar. Havells Mount Bollard
MOUNTBLMINIMOUNTBL10WLED830PSYMTOPMMAS
. The product should be BIS approved with R number
mentioned on product label. To be supported with
Product test reports - LM79, Is 10322/IEC 60598 and for
LEDs - LM80, RoHS and Photo Biological Safety
Supplying and fixing of Spike Light LED of Havells cat no.
IRVINESPS5WLED830PSYMTG or equivalent.
Supply, fixing &testing of prewired external light fixture
having Die-cast housing with epoxy coating and
having profiled cooling fins at the top for effective
103 heat dissipation, separate driver and LED lamp cavity,
heat resistant toughened clear glass cover with high
transmittance and high quality gasketing system,
high power LED complete as required.
25 Watt LED Fitting Lighting lantern on GATE/ POST TOP
of Havells Cat
no.CORALMINIPT15WLED757PSYMTOPC or equivalent
Street Light Luminare of 60 watt LED including suitable
fixing MS clamps etc.as requird of Havells Cat No.
ENDURASUNDOWNSL60WLED765PASYBOTG or
Street Light Luminare of 35 watt LED including suitable
fixing MS clamps etc.as requird of Havells Cat No.
ENDURASUNDOWNSL35WLED765PASYBOPC or
Floodlight LED luminaire 50 Watas with high pressure
die cast housing with IP66 deg of protection of Havells
Cat No. JETAQUANTOPLUSFLP50WLED757SYMLENS
DSR TOTAL Rs. 78,64,602.77
NON DSR TOTAL Rs. 62,99,986.60
DSR + NON DSR TOTAL Rs. 1,41,64,589.38
PROJECT : BILL OF QUANTITY FOR HVAC WORK FOR PROJECT BUILDING IN D-WING
SUMMARY OF PRICES AMOUNT
1 PART A VRF EQUIPMENT Rs. 37,82,810
2 PART B PIPING WORK Rs. 5,40,950
3 PART C AIR DISTRIBUTION SYSTEM. Rs. 5,33,567
4 PART D LOW SIDE MECHANICAL VENTILATION SYSTEM Rs. 42,771
5 PART E ELECTRICAL WORK Rs. 4,96,940
TOTAL OF ALL ABOVE Rs. 53,97,038
Note:- Final Quantity As Per The GFC Provided By HVAC Contractor 10% Variation For Tender Drg.
BILL OF QUANTITIES
S.No Description Unit Qty. Rate (Rs.) Amount (Rs.)
PART A VRF EQUIPMENT
Variable Refrigerant Flow Air-conditioning System
Supply,instalaltion ,testing and commissioning of variable refrigerant flow modular
type airconditioning system invertor controlled with stepless modulation complete
with indoor and outdoor units,individual remote controller and centralized
controller,interconnected refrigerant piping,full charge of refrigerant gas &
oil,control cabling etc.as per detail given in specifications and having following
items:(The prices to be given in Indian rupees on Full Import duty basis)
Refrigerant to be used shall be - R - 410 A.
Supply , installation, testing and commissioning of Outdoor Unit with blue fin
coating@ 44.4 Degree C
Supply,installation, testing and commissioning of side /top discharge Modular type
outdoor units equipped with highly efficient scroll compressors with both inverter
speed type compressors special heat exchanger,low noise condenser fan ,auto
check function for connection error,auto address setting and capacity as
mentioned below. Cable termination with double compression glands. The unit
shall be filled with first charge of refrigerant and ready for use as required. Any
additional top up charge required at the time of commissioning is inclusive in cost.
Note :-All Outdoor units shall be mounted on MS powder coated / epoxy painted
stand along with fixing arrangement as approved by engineer incharge.
i 12 HP OUTDOOR UNIT For (Conference & Min.Conference Room) Nos. 1 2,70,000 2,70,000
i 16 HP (8+8 HP) OUTDOOR UNIT For (TFA Uunit) Nos. 1 360000 3,60,000
ii 3x18 HP OUTDOOR UNIT (Balance Areas) Nos. 3 405000 12,15,000
2) Supply Instalaltion, testing and commissioning of Indoor Units with + 5% Tolerence
All Below units shall be provided with Remote Control
A CEILING TYPE CASSATTE UNIT
i 1.6 TR Split Units Regular Cassette TypeI Nos. 11 32,500 3,57,500
ii 1.28 TR Split Units Regular Cassette TypeI Nos. 10 28,500 2,85,000
B WALL MOUNTED HI - WALL UNIT
i 1.28TR Split Units Nos. 12 17,280 2,07,360
ii 1.0TR Split Units Nos. 12 12,800 1,53,600
C CEILING TYPE TFA UNIT
i 6.4 TR TFA Units Nos. 2 78000 1,56,000
3) Supply,instalaltion,testing and commissioning of Y-joints. Nos. 46 3250 1,49,500
Supply, Instalaltion, testing and commissioning of self diagnostic type Remote
Controllers. Corded Type
5 Refrigerant R-410A to Top up the system if required. Kg 75 1250 93,750
Supply, instalaltion, testing and commissioning of Main Intelligent central
6 controller system Touch Screen suitable for above indoor units to operate, Nos. 1 48000 48,000
monitor, on/off, temperature setting etc.
Comprehensive Annual maintenance contract for VRF System with BMS System
including Energy monitoring & Central Remote Control for Suitable for 82.0HP
Digitally signed by PRIYA
S.No Description Unit Qty. Rate (Rs.) Amount (Rs.)
i After First year L/s 1 168100 1,68,100
ii After Second year L/s 1 184500 1,84,500
8 DX TYPE SPLIT UNIT WITH 3 STAR RATING WITH GREEN GAS
Supply , installation, testing & Commissioning of DX type split AC units with air
cooled condenser mounted in outdoor unit complete with scroll/rotary
compressor ,condensor ,wiring & accessories . Indoor units shall be wall mounted
type complete with evaporator ,fan, filter ,drier, expansion devices &
microprocessor control panel along with all accessories with refrigerant & oil
charge , cordless remote controls. The unit shall be suitable for working 50 cycle
/second ,1 phase AC supply .The unit shall be designed to take care of veritcal head
4mt & horizontal length of 15mt & necessary oil seprator shall be included
,Necessary supporting arrangement for both indoor & outdoor units ( Powder
Coated /Epoxy painted MS stand for ODU units as per approved make shade by
Architect) with necessary vibration isolation arrangement as per site condition
etc.( without condensate drain pipe ,electrical pipe ,electrical power & control
cabling between indoor & outdoor unit which shall be paid seprately ). The Color
of the outdoor units to be finalized by the Architect as per building Architectural
i All Unit shall be Minimum 3 Star Rating Based
ii The Outdoor unit Compressor must be provided with 5 Year Warranty Period.
Civil Work such as wall hole making , wall chiseling, refilling of chiseling part with
mortar etc as per site condition.
Nitrogen pressure testing for leakages & flushing during installation & after
commissioning between IDU & ODU with flar nuts
Removable Covers for all indoor & Outdoor units shall be supplied & put on the
units after installation & commissioning.
vi Incoming power supply shall be provided near each indoor units
vii Sound level of Outdoor unit shall be 70 Db at 1 Mt Distance
Below All outdoor units to be provided with blue fin / UV coating . No extra price
shall be paid for the same .
a) 2.0 TR Split Units Nos 2 50000 1,00,000
Insulated Refrigerant piping for above split unit 2.0TR (As per site Location) RMT 30 1150 34,500
Total of Part A carried to Summary of Prices. 37,82,810
PART B PIPING WORK
Supply, installation, testing and commissioning of interconnecting copper
refrigerant pipe work (19mm /13mm thick )duly insulated with ( Class O )
elastomeric nitrile rubber type tubular insulation between indoor & outdoor units
as per specifications. All piping inside the room shall be properly supported on GI
Slotted Channel and all external piping shall run in Cable tray with top cover
(Cable tray with top cover to be paid separately as per Item. 6). All outside piping
insulation to be covered with protective coating. ( fiber glass cloth helically wound
and coated with 2-coats of reisn with hardner to give smooth and plain finish.)
i 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm RMT 15 2050 30,750
ii 38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm RMT 25 1850 46,250
iii 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm RMT 35 1550 54,250
iv 31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm RMT 35 1250 43,750
v 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm RMT 45 1050 47,250
vi 25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm RMT 35 850 29,750
vii 22.2 mm O.D. (insulation – 19 mm thick) RMT 55 790 43,450
viii 19.1 mm O.D. (insulation – 13 mm thick) RMT 35 705 24,675
ix 15.9 mm O.D. (insulation – 19 mm thick) RMT 45 610 27,450
x 12.7mm O.D. (insulation – 19 mm thick) RMT 155 495 76,725
xi 9.5 mm O.D. (insulation – 13 mm thick) RMT 45 410 18,450
xii 6.4 mm O.D.(insulation : 13 mm) RMT 155 305 47,275
Supply, installation, testing and commissioning of uPVC 10 Kg/Sq.cm drain water
piping complete with fittings,connection bush, support as per specification and
2) insulated with 6 mm thick closed cell elastomeric nitile rubber insulation including
the cost of cutting & filling chases in wall/floor, repairing using wire mesh &
making good with rough finish.
ii 32 mm dia O.D RMT 55 265 14,575
iii 40 mm dia O.D RMT 10 310 3,100
Total of Part B carried to Summary of Prices. 5,40,950
PART C AIR DISTRIBUTION SYSTEM.
1) GSS RECTANGULAR DUCTING
Digitally signed by PRIYA
S.No Description Unit Qty. Rate (Rs.) Amount (Rs.)
Supply,installation, balancing & commissioning of Factory fabricated GSS sheet
metal ducting complete with neoprene rubber gaskets , elbows , splitter dampers
, vanes , hangers, supports etc. as per approved drawings and specifications of
following sheet thickness complete as required.
splitter & vanes etc.shall be apart of ducting no extra cost shall be paid for the
All supports shall be provided with 1 coat of primer & 2coat of black paint
RECTANGULAR DUCTING (FACTORY FABRICATED)
iii 20 G SMT 0 -
Supply,installation, balancing & commissioning of Site fabricated GSS sheet metal
ducting complete with neoprene rubber gaskets, elbows,splitter
dampers,vanes,hangers, supports etc. as per approved drawings and specifications
of following sheet thickness complete as required.
All supports shall be provided with 1 coat of primer & 2coat of black paint
iii 20 G SMT 0 -
3) Main Box Type Duct Damper
Supply, fabrication, installation and testing of 18G GI construction Main duct
3.1 damper for supply & return air complete with nuts bolts, screws, linkage, flanges SMT 4 5850 23,400
etc.ducts lever and quadrants for proper balancing of the air distribution system .
Supply,installation, testing and commissioning of 50 micron powder coated
4) "Aluminium"collar volume control dampers with key operated of black painted in SMT 4 4850 19,400
supply & Return air registers / terminals.
Supply,installation,testing and commissioning of 50miron Powder coated
5) Aluminium extruded Grille /Diffuser for supply and return air as per specification &
the sizes will be as per the drawing
Supplying & fixing of Fresh air intake louvers with bird screen (Aluminium extruded
only) as per specification and sizes will be as per shop drawing mentioned.
7) Duct Insulation
Supplying , installation, testing & commissioning of external thermal insulation on
ducts with Closed Cell Cross Linked Polythylene (XLPE) Foam of density 33 Kg/m³
with 13 mm thick & thermal Conductivy not exceding 0.035 W/mK at an average
Temperature of 40°C. The Material Shall be rated as Class 1, As per BS476 Part 7 ,
The Smoke Density as per AS - 1530.3 Shall not exceed 1. The Material shall have
Fire Approval from CBRI - Roorkie & no toxicity under flaming and non- flaming
condition as per AITM 3.000 (1993) .Adhesive used for setting the insulation shall
be non - flammable,Vapour Proof. All Joints should be sealed with 3 mm thick 50
mm wide PE tape and Flange to be overlapped by 6" width of the same material
thickness. Finally Duct insulated should be strapped by 12mm Plastic Packing strip
at every random meter & conforming to standard Spec.
13 mm thick Closed Cell Cross Linked Polythylene( XLPE) Foam with Factory
Laminated Al PE Foil for Supply Air Duct
Supplying and fixing of acoustic lining of duct with fibre glass rigid board of density
8) 48 Kg/m³ sealed in fibre glass tissue paper andcovered with 0.5 mmthick
perforated aluminium sheet and conforming to standard specification.
i 12 mm thick fibre glass rigid board. SMT 5 910 4,550
Total of Part C carried to Summary of Prices. 5,33,567
PART D LOW SIDE MECHANICAL VENTILATION SYSTEM
1) INLINE FAN WITH REGULATOR
Supply, installation, testing and commissioning of ceiling suspended Inline fans
(Rectangular/Round casing) complete with bird screen, rain guard, metal clad MCB
& starter ,5m length copper cable, earthing wire all compete as required of
following capacities as per specification and shop drawing mentioned.
EXHAUST AIR (For Toilet Area)
ii 150 CFM ,20mm St.Pr. Nos 7 2263 15,841
iii 300 CFM ,20mm St.Pr. Nos 1 4530 4,530
Digitally signed by PRIYA
S.No Description Unit Qty. Rate (Rs.) Amount (Rs.)
Total of Part D carried to Summary of Prices. 42,771
PART E ELECTRICAL WORK
1) ELECTRICAL WORK FOR HVAC EQUIIPMENTS
2) POWER ,CONTROL CABLING & EARTHING
Supplying,laying,effecting proper connections, testing & commissioning of the
following sizes of 1.1 KV - Cross Linked Poly Ethelene armoured aluminum /
Copper conductor and control cabling cables conforming to relevant latest
amended Indian Standards including clamping the cables to supports in an
approved manner as required complete with all accessories.
FOR VRF OUTDOOR :-
(cabe as per site location)
4C x 10 mm² Cu PVC Cable RMT 40 647 25,880
4C x 10 mm² Cu PVC Cable RMT 60 647 38,820
4C x 10 mm² Cu PVC Cable RMT 120 647 77,640
Providing & fixing weather proof isolator with suitable rating near each unit. SET 10 5500 55,000
4) POWER CUM CONTROL CABLING
Supply and laying ,testing & commissioning of following sizes of sheilded Copper
conductor control cables Sq. mm in PVC conduit with including fixing clamps &
effecting proper connections to equipment etc. complete as required .
4.1 3C X 1.5 Sq.mm shielded cable (as per site location) RMT 1200 180 2,16,000
Supply & laying 8 SWG GI wire at 0.5mt below ground level for conductor earth
electrode,inculding connection / termination with GI thimble etc as required .
The AC contractor shall provide fire shunt relay contact in his panel wherever
necessary along with auto/ manual mode selector switch in the outgoing feeder
for HVAC EQUIPMENTS etc.To take fire input signal (Potential Free Contact).Cost
shall be included in the panel price quoted by him.
Total of Part E carried to Summary of Prices. 4,96,940
Digitally signed by PRIYA
Sl. No Description of Item Ref Image Quantity Rate (Rs) Amount(Rs)
Supply, Installation and placement of High Back Chair
with Headrest from manufacturers certified with ISO
14001:2015 (all ISO must be from NABCB/IAF
accredited agency),BIFMA (LEVEL 2), Indoor air quality,
Indoor Air Advantage Gold, Green Pro,Greenguard (by
UL), Griha 2019.1.SEAT/BACK ASSEMBLY: The
Cushioned seat assembly consshould be ts of seat
outer (material-30% Glass Fiber Nylon)& upholstered
Seat inner (material- Poly
Propylene) with moulded Polyurethane foam &
polyster fabric. The Net Back should be made up of
Back outer (material-Glass Fiber Filled Nylon)& Back
inner (material- PP) and upholstered using Polyester
fabric with high tenacity yarn.Full Back Size: 46.5 cm.
Supply, HIGH RESILIENCE
Installation (HR) POLYURETHANE
and placement of Chair without
Headrest from manufacturers certified with ISO
14001:2015 (all ISO must be from NABCB/IAF
accredited agency),BIFMA (LEVEL 2), Indoor air quality,
Indoor Air Advantage Gold, Green Pro,Greenguard (by
UL), Griha 19.SEAT/BACK ASSEMBLY: The Cushioned
seat assembly cons should be ts of seat outer
(material-30% Glass Fiber Nylon)& upholstered Seat
inner (material- Poly Propylene) with moulded
Polyurethane foam & polyster fabric. The Net Back
should be made up of Back outer (material-Glass Fiber
Filled Nylon)& Back inner (material- PP) and
2 upholstered using Polyester Mesh fabric with high 26 30,321.12 788349.1229
Supply, Installation and placement of Storage from
manufacturers certified with ISO 9001:2015, ISO
must be from NABCB/IAF accredited agency),BIFMA
(LEVEL 2), Indoor air quality, Indoor Air Advantage
Gold, Green Pro,Greenguard (by UL), Griha 2019.AV
storage of the following specifications with size should
be be 1745 X 670 X 740 CARCASS-Made of 18mm Thick
Pre-laminated twin board of E1-P2 grade and approved
shade conforming to should be -12823:1990, Edge
banded with matching 0.8 mm thick PVC lipping. Pilot
holes provided for fixing 12U AV equipment rack.
Supply, installation and testing of U shape modular
conference table (9mx3.2m approx) as per approved
technical specification and direction of BSL
MINGLE MODULAR 12 SEATER CONFERENCE TABLE
Digitally signed by PRIYA
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
1 NIT.pdf
Tender Document
2 SCC.pdf
Tender Document
3 BOQ.pdf
Tender Document
4 List of Approved Make .pdf
Tender Document
5 Physical Milestone Annex I-A.pdf
Tender Document
6 SCOPE OF WORK_PB.pdf
Tender Document
7 GCC PMC 2022 AMEND 1 TO 14.pdf
Tender Document
8 Drawings.pdf
Tender Document
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .