| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 LAdmitted-Finance 2ND FLOOR SHOP NO 303 MARUTI PLAZA RONCHI BANGAR TOWNSHIP MATHURA | MATHURA | UTTAR PRADESH | 281001 | ₹2.1 L | L1 | Admitted-Finance |
| 2 | L2₹2.2 LAdmitted-Finance 06 ARPA COMPLEX BESIDE RAJIV PLAZA COMPLEX OLD BUS STAND BILASPUR BILASPUR CHHATTISGARH 495001 | BILASPUR | CHHATTISGARH | 495001 | ₹2.2 L | L2 | Admitted-Finance |
| 3 | L3₹4.8 LAdmitted-Finance | ₹4.8 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | TIRUPATI ELECTRICALS L3 | P&H Engineering L1 | DEEP ENTERPRISES L2 |
|---|---|---|---|---|---|---|
| 1.00 | Safe carriage of the following equipment including loading and unloading on trucks duly arranged by the contractor from stores of different sub - station of electricity transmmision circle gr. Noida ( approx. dist. 100 KM ), with all due care of safety & precautions during transit required for the job including the insurance / fare / toll tax etc. of all the trucks. (A) Transpotation of 03No. 33KV PT, 03No. 33KV CT and 02 set 33KV Isolator. | 1 | JOB | 30,000 ₹30,000 | 10,000 ₹10,000 Lowest | 10,200 ₹10,200 |
| 2.00 | (B) Transpotation of 01No. 33KV VCB, 01 No. 33 KV Tripple feeder C&R Panel & various size control cable (2KM). | 1 | JOB | 10,000 ₹10,000 Lowest | 10,000 ₹10,000 Lowest | 10,000 ₹10,000 Lowest |
| 3.00 | Safe carriage of the following equipment ( ALP, ABL,& CCR ) Loaded structure from electy. Fabrication unit Naini Prajagraj to 132 Kv S/S Shikarpur Under ETD - Khurja ( Distance Approx. 730 km. ) CCR - ( 2 No. ) Column, CGR - ( 1 No. ) Beam, TMR - ( 1 No. ) Mast, ALP - ( 13 No. ), ABL - (2 No.) | 3.4 | MT | 10,000 ₹34,000 | 7,000 ₹23,800 Lowest | 10,450 ₹35,530 |
| 4.00 | Erection of Auxiliary Structure as ALP-03 Nos (approx weight- 121Kg), ABL-02Nos (approx weight-341 Kg) and 33 KV Circuit Breaker related structure installing as per drawing with the help of G.I. nut & bolt, flat, spring washer, matching the hole. | 3.4 | MT | 7,000 ₹23,800 | 4,000 ₹13,600 | 3,200 ₹10,880 Lowest |
| 5.00 | Erection of 33 KV equipments including shifting of equipments and accessories from store to erection site, fixing of required clamps, all related cable termination with cable glands according schedule, welding and other related associated works with testing and commisoning. (A) 36 KV Bus Isolator (1250 Amp) | 1 | Nos. | 6,000 ₹6,000 | 2,300 ₹2,300 | 2,000 ₹2,000 Lowest |
| 6.00 | (B) 36 KV Line Isolator | 1 | Nos. | 7,000 ₹7,000 | 2,000 ₹2,000 Lowest | 2,100 ₹2,100 |
| 7.00 | (C) 36 KV CTs (400/200/1A) | 3 | Nos. | 3,000 ₹9,000 | 2,000 ₹6,000 | 390 ₹1,170 Lowest |
| 8.00 | (D) 36 KV CT Junction box | 1 | Nos. | 1,000 ₹1,000 | 500 ₹500 | 390 ₹390 Lowest |
| 9.00 | (E) 33 KV VCB | 1 | Nos. | 10,000 ₹10,000 | 8,000 ₹8,000 | 7,980 ₹7,980 Lowest |
| 10.00 | (F) 33 KV Tripple feeder control and relay panel (Conventional Type) | 1 | JOB | 5,000 ₹5,000 Lowest | 5,000 ₹5,000 Lowest | 9,520 ₹9,520 |
Tender Value
₹2.5 L
EMD Value
₹3,000
Closing Date
1 Jun 2026, 12:00 pmClosed
SE ETC GREATER NOIDA
400 KV SUB STATION PALI GAUTAM BUDH NAGAR GREATER NOIDA
FOR CONSTRUCTION OF 33 KV BAY AT 132 KV SUB STATION SHIKARPUR UNDER ETD KHURJA UNDER ETC GREATER NOIDA
2026_UPTCL_1152825_1
T-05/2026-27ETC/GN
Open Tender
Electrical Works
Item Rate
45 days
KHURJA
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
EE ELECTRICITY 400 KV S/S DIV. GREATER NOIDA
₹3,000
30 Jul 2026
23 May 2026
1 Jun 2026
23 May 2026
1 Jun 2026
23 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Safe carriage of the following equipment including loading and unloading on trucks duly arranged by the contractor from stores of different sub - station of electricity transmmision circle gr. Noida ( approx. dist. 100 KM ), with all due care of safety & precautions during transit required for the job including the insurance / fare / toll tax etc. of all the trucks. (A) Transpotation of 03No. 33KV PT, 03No. 33KV CT and 02 set 33KV Isolator. | - | JOB | 10,000 | - |
| 2 | (B) Transpotation of 01No. 33KV VCB, 01 No. 33 KV Tripple feeder C&R Panel & various size control cable (2KM). | - | JOB | 10,000 | - |
| 3 | Safe carriage of the following equipment ( ALP, ABL,& CCR ) Loaded structure from electy. Fabrication unit Naini Prajagraj to 132 Kv S/S Shikarpur Under ETD - Khurja ( Distance Approx. 730 km. ) CCR - ( 2 No. ) Column, CGR - ( 1 No. ) Beam, TMR - ( 1 No. ) Mast, ALP - ( 13 No. ), ABL - (2 No.) | 1 | MT | 10,500 | ₹10,489.5 |
| 4 | Erection of Auxiliary Structure as ALP-03 Nos (approx weight- 121Kg), ABL-02Nos (approx weight-341 Kg) and 33 KV Circuit Breaker related structure installing as per drawing with the help of G.I. nut & bolt, flat, spring washer, matching the hole. | 1 | MT | 3,225 | ₹3,221.78 |
| 5 | Erection of 33 KV equipments including shifting of equipments and accessories from store to erection site, fixing of required clamps, all related cable termination with cable glands according schedule, welding and other related associated works with testing and commisoning. (A) 36 KV Bus Isolator (1250 Amp) | - | Nos. | 2,000 | - |
| 6 | (B) 36 KV Line Isolator | - | Nos. | 2,000 | - |
| 7 | (C) 36 KV CTs (400/200/1A) | - | Nos. | 400 | - |
| 8 | (D) 36 KV CT Junction box | - | Nos. | 400 | - |
| 9 | (E) 33 KV VCB | - | Nos. | 8,000 | - |
| 10 | (F) 33 KV Tripple feeder control and relay panel (Conventional Type) | - | JOB | 9,500 | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
T05.pdf
Tender Documents • 0.62 MB
BOQ_2159594.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].