Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Bid | |
| 2 | L2₹34.0 L+₹1.4 L (4.14%)Rejected-Finance R G BARUAH ROAD NEAR SHIV MANDIR GUWAHATI AIRPORT GUWAHATI 781015 | KAMRUP METRO | ASSAM | 781015 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹34.7 L+₹2.1 L (6.42%)Rejected-Finance | L3 | Rejected-Finance Other than L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
27 Oct 2021, 6:00 pmClosed
GE (AF) Borjhar
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati, Assam, Pin- 781015 Tele 0361 - 2840127
Annual Maintenance, Repair and Cleaning of Sewage Line, Septic Tank, Manhole, Soak Pits at certain Units, 3 AFSR, 11 ASC, 8 LU, NKP, Site C and MES area and Certain B/R Works in E/M Installation under GE(AF) Borjhar
2021_MES_474335_1
8239/BOR/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Borjhar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Borjhar
₹60,000
Yes
4 Dec 2021
10 Sept 2021
29 Oct 2021
10 Sept 2021
27 Oct 2021
29 Sept 2021
Amount
Dismantling asbestos cement (corrugated, semi corrugated, etc) sheets in roof coverings including ridges complete all as specified and as directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness of roof covering complete all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges of roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Dismantling timber scantlings 40sq.cm and over in section, in any position complete all as specified and as directed.
S&F for framed brackers of angles or tees with web and flangs cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc, n exc. 10 kg each brackets, conforming to Fe-410-0 or Fe-310 complete all as specified and as directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed.
M&L for weather boarding, clean sawn, plain, 20mm thick or feather edged 15mm to 20mm thick and fixed with 30mm laps of 2nd class hard wood, planed both sides with butt joint fixed with nails to timber frame/roof member complete all as specified and as directed..
Dismantling boarding, any description, fixed in any position with screws complete all as specified and as directed.
M&L for 4mm thick non asbestos fibre cement building boards, fixed or laid/inserted to timber/GI/Aluminium frame work with screws complete all as specified and as directed.
S&F 605 x 605mm anodised aluminium snap grid frame work for false ceiling complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and as directed.
M&L for brickwork with sub class 'B' bricks using old size bricks, stright or curved on plan exc. 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
Demolition of cement concrete in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and as directed.
Taking out old existing treatment of any thick from RCC roof by scrapping, scrubbing and brooming down, etc. complete all as specified and as directed.
M&L for 40mm thick PCC (1:2:4) type B-0 (using 12.50mm graded stone aggregate) as in roof pedding, etc. finished surface even and fair without using extra cement complete all as specified and as directed.
M&L for 15mm thick cement plaster with cement mortar (1:4) mixed with WPC by weight of cement as per manufacture'r instructions on other than fair faces of brick surface, finished even and fair without using extra cement over and including cement slurry @ 3 Kg per Sqm with WPC on existing roof surface complete all as specified and as directed.
M&L for preparation and cleaned to plastered/ concrete surface of roof and applying the under mentioned course of roof treatment as given below:- (a) Applying evenly compactible primer @ 0.4 litre/sqm over concrete/plastered roof surface (b) Applying a tack coat of industrial bitumen @ 85/25 grade (ISI marked) @ 1.2kg/sqm (c) Laying of 3mm thick membrane sheet of weight not less than 3.6 kg/sqm with minimum longitudinal end over laps of 100mm and horizontal side laps of 75mm and joints finally thermofused with help of LPG flames. Membrane sheet laid over a tack of industrial bitumen 85/25 as specified.
Taking down cement plaster on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water, etc.complete all as specified and as directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surface in cement mortar (1:4) mixed with water proofing compound by weight of cement, surface finished even and smooth complete all as specified and as directed. Note : Water proofing compound shall be measured and paid separately.
M&L for 15mm thick rendering in cement mortar (1:6) on faces of brick work or concrete surfaces of walls, finished fair and even complete all as specified and as directed
M&L for rendering 5mm thick in cement mortar (1:3) as on ceiling surfaces complete all as specified and as directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper complete all as specified and as directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed.
M&L for three coats of white wash on newly plastered surfaces of ceiling including preparation of surfaces complete all as specified and as directed..
Supply only Integral waterproofing compound (ISI mark) complete all as specified and as directed.
Taking down chowkats or frames including shutter (without taking off shutters from the frame) area n. exc. 1.5 Sqm each, removing from the site including cutting holes required for taking out existing hold fast, etc. complete all as specified and as directed
All as per Serial item No. 27 here-in-before but exc. 1.50 Sqm and n. exc. 4 Sqm.
S&F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, and edges will be painted to match will printed sheet fixed in opening as per specifications and drawings complete all as spcified and as directed.
S&F factory made solid panel PVC door shutter, 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed.
M&L pressed steel frames for doors of size 105mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified complete all as specified and as directed.
S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S&F MS butt hinges of size 75mm long, medium weight, cold rolled complete all as specified and as directed.
S&F for 125mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
S&F for 100mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed.
S&F for 300mm length aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts complete all as specified and as directed.
S&F for butt hinges of size 100mm, extruded aluminium alloy with galvanised mild steel hinges pin, anodised and fixed C-21 complete all as specified and as directed.
S&F for aluminium handles, cast type, anodised of size 150mm complete all as specified and as directed.
S&F for 200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed.
M&L for preparation of new wooden surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description, not otherwise provided for complete all as specified and as directed.
S&F for steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
S&F for steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and as directed.
S&F for steel ventilator with top hung shutter including hinges, steel peg stay, wheel and all other fittings complete all as specified and as directed.
M&L for 3mm thick sheet glass, ordinary quality and glazing with oil putty or with wooden beading are to be fixed wooden frame or steel frame, area n. exc. 0.5 sqm in each pane complete all as specified and as directed.
S&F 3mm thick frosted sheet glass, ordinary quality and glazing with oil putty or with wooden beads, area n. exc 0.5 sqm in each pane complete all as specified and as directed.
S&F in for galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed.
S&F as in repairs for galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description, over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal or wooden frame including punching or drilling out old glazing pins/spring clips or fixed with putty or beads copmlete all as specified and as directed.
S&F mild steel work, grade Fe -290 Gd-E-265, as in guard bars, etc. complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed.
M&L for non-skid coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, as in floors over and including 15mm thick screed bed or bedding in layer in cement mortar (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and as directed.
M&L for non skid ceramic designer coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 20mm thick screed bed in cement mortar (1:6) complete all as specified and as directed.
M&L for glazed ceramic coloured tiles of size 350mm x 250mm x 7mm/450mm x 350mm x 7mm thick on vertical surfaces, such as dado, skirtings, etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15mm thick rendering screed bed in cement mortar (1:4) complete all as specified and directed.
Taking down rolling shutters of any description exc. 2 sqm but n exc. 6 sqm each and removing to store from site complete all as specified and as directed.
S&F steel rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, push pull or manual type, thickness of laths 1.25mm complete all as specified and directed.
S&F ball bearing for rolling shutters as per existing size and make complete all as specified and as directed.
Repair to steel rolling shutter of any description including taking down and refixing the same with necessary adjustment to ball brearing including oiling and greasing to make serviceable complete all as specified and as directed.
M&L for preparation of old distempered surfaces of walls, cornices, etc. by washing, rubbing down, stopping, etc. and applying one finishing coat of distemper oil emulsion complete all as specified and as directed.
M&L for preparation of old plastered/concrete surfaces of any description and applying one finishing coat of cement base paint complete all as specified and as directed.
All as per Serial Item No 61 here-in-before but one coat as on ceiling.
M&L for preparation of old decorated white washed, plastered or un-plastered surfaces of walls and applying one finishing coat of white wash complete all as specified and as directed.
M&L for preparation of old decorated surface of external fins, fascia, vertical and horizontal surface of roof projection, chajja, etc. and applying one coat of weather coat anti fungal exterior coating emulsion paint complete all as specified and as directed.
M&L for 75mm thick cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) as in plinth protection, footpath, etc. complete all as specified and as directed.
M&L for 15mm thick screed bed or bedding layer of cement mortar (1:6) for laying floor finishes complete all as specified and as directed..
M&L for coloured chequered cement concrete tiles of size 20cm x 20cm x 22 to 25mm thick with grey cement and pigment, set jointed and pointed in neat cement slurry as on floors complete all as specified and as directed.
All as per Serial item No. 67 here-in-before but of size 30cm x 30cm x 22 to 25mm thick
S&F as in repairs vitreous china wash down closet pan (pedestal pattern), white, with ‘P’ or ‘S’ trap, plastic seat cover, white, including connection to out going pipe and to flushing pipe, anti-syphonage pipe, etc. (excluding flushing cistern) complete all as specified and as directed.
S&F as in repairs vitreous china squatting pan (Orissa pattern) water closet (white) of size 580 x 440mm with integral foot rests, 'P' or 'S' trap, including connection to trap and flushing pipe, antisyphonage pipe, etc. and making good to floors as existing complete all as specified and as directed.
S&F as in repairs vitreous china wash hand basin, white, flat back of size 550mm x 400mm including a pair of cast iron cantilever brackets of size 40x40x5mm, embedded in PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) with and including 32mm dia PVC waste pipe and 32mm chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed including 15mm bore PVC connection pipe, 450mm long complete all as specified and as directed.
S&F as in repairs pillar taps,15mm dia, fancy type with capstan heads, chromium plated, screwed down, high pressure with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
S&F as in repairs PVC valveless symphonic action type, low level flushing cistern (ISI marked) of 10 litres capacity including 32mm dia PVC flush pipe, connected to water closet with inlet, ball valve, float and handle including 15mm bore PVC connection pipe complete all as specified and as directed.
S&F as in repairs PVC connection pipe, 15mm dia, 450mmm long with 2 Nos PVC check nuts with washer complete all as specified and as directed.
S&F as in repairs 15mm bore angle valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified and as directed.
S&F as in repairs 15mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified and as directed.
S&F as in repairs 15mm dia bib taps, cast copper alloy, chromium plated, fancy type with capstan head, long body and cup, screwed down for iron pipe, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified and as directed.
S&F as in repairs high density polyethylene pipes (HDPE), 32mm dia of pressure rating 6kgf/cm2, fixed to walls, ceilings or in floors, etc.complete all as specified and as directed..
M&L for 75mm thick cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in hardstanding and like complete all as specified and as directed.
Forming 12mm thick expansion joints, filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ complete all as specified and as directed.
Taking up or down steel tubing 15mm bore and connections with all fittings including cleaning for refixing or removing from site complete all as specified and as directed.
All as per Serial item No. 81 here-in-above but 20mm bore.
All as per Serial item No. 81 here-in-above but 25mm bore.
Refixing old steel tubing, 15mm bore and connections in new or old position such as walls, ceiling, floors, etc. complete all as specified and as directed. Note : Steel tubes obtained from Serial item No. 81 above shall be used.
All as per Serial item No. 84 here-in-above but 20mm bore. Note : Steel tubes obtained from Serial item No. 82 above shall be used.
All as per Serial item No. 84 here-in-above including note but 25mm bore. Note : Steel tubes obtained from Serial item No. 83 above shall be used.
Supply and laying 15mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed complete on walls and ceilings or laid in floors, etc. complete all as specified and as directed.
All as per Serial item No. 87 here-in-above but 20mm bore.
All as per Serial item No. 87 here-in-above but 25mm bore.
Disconnecting of old existing tanks of any description, exc. 250 litres and n. exc. 500 litres capacity and removing from site complete all as specified and as directed.
S&F 500 liters capacity rotational moulded polyethylene water storage tank (cylindrical vertical with closed top cover) as per IS-12701-1996, hoisted and fixed in position as specified in SSR Part-I complete all as specified and as directed. Note : The cost of accessories like as inlet and outlet pipe, ball valve, air vent pipe, etc. shall measured and paid separately.
S&F 20mm bore ball brass valve, high pressure with polythene float and flynut, screwed for iron pipe or brass ferrule complete all as specified and as directed.
Disconnecting of old existing tanks of any description, exc. 250 litres and n. exc. 500 litres capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required including reconnecting and re-fixing in position complete all as specified and as directed.
S&F as in repairs grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and as directed.
Demolition and breaking up drain pipes (SGSW, AC or reinforced concrete) of 150mm internal dia, set in cement mortar complete all as specified and as directed.
All as per Serial item No. 97 here-in-before but 100mm bore.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation, manholes, etc. not exc. 10 sqm on plan and not exc 1.5m in depth including getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and as directed.
Removing excavated surplus soil/material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L for Salt Glazed Stone Ware drain pipe of 100mm internal dia, grade ‘A’, laid in trenches and jointed complete all as specified and as directed.
All as per Serial item No. 102 here-in-before but 150mm internal dia of pipe.
M&L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in concrete bed to drain pipes of 100mm bore, including packing under, and haunching against the sides of pipes after they are laid and tested in complete all as specified and as directed.
All as per Serial item No. 104 here-in-before but for 150mm bore pipe.
M&L for brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 metre means radius, built in cement mortar (1:4) complete all as specified and as directed.
M&L for preparing of new plastered/concrete surfaces of walls, etc. and applying two coats of oil bound distempers including one coat of primer with alkali resistant complete all as spicified and as directed.
M&L for pre-cast RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in manhole cover slab and drain cover, set in cement mortar (1:4) with plain faces including necessary form work, etc. complete all as specified and as directed.
M&L for mild steel TMT bars, 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending, spirally for hopping for columns, hooking ends, and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips of quality Fe-500, conforming to IS -1786-1985 complete all as specified and as directed.
Cutting into existing manhole, 100mm bore pipe, for connecting new drains, making good to pipe and removing cutting out existing benching for and forming branch channel in cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregates), smooth finish and re-forming benching complete all as specified and as directed
All as per Serial item No. 110 here-in-before but for 150mm bore pipe.
Cleaning sewage line of 100mm bore pipe and removing the blockage by means of rodding with and including bamboos, splits/flexible iron wire or concrete malacces rods from manhole to manhole, through pipes from trap to manhole, rendering the system clear and flushing the delogged line with sufficient quantity of water and removing sludge/waste materials, etc. to a distance n. exc. 50m and burrying in pipts and re-filling the same with sprinkling bleaching powder around and over complete all as specified and as directed. Note : Rate quoted shall be inclusive for necessary excavation and earth work for pits under this item.
All as per Serial item No. 112 here-in-before including Note but 150mm bore pipe line.
Cleaning to blocked soil pipe vertical stack 100/110mm dia by opening inspection eye door of bend/branch pieces, rodding till smooth flow and refixing of door after cleaning including necessary scaffolding, etc. complete all as specified and as directed.
S&F as in repairs SWG gully traps, square type of size 150mm x 100mm complete all as specified and as directed. .
Taking down/removing gully trap covers from waste pipes of kitchen and bathrooms, removing blocked waste materials, cleaning and re-fixing the gully trap covers with all necessary items complete all as specified and as directed.
Cleaning manhole by taking out sludge in semi liquid/solid stage including water, etc. from inside of manhole of depth not exceeding 1.5m and removing the sludge to a distance not exceeding 50m depositing in trenches including supply and sprinkling bleaching powder and covering sludge with earth to a thickness not less than 30cm including necessary earth work, returning filling, removal of surplus soil and temporary cleaning complete all as specified and as directed.
All as per Serial item No. 117 here-in-before but depth exceeding 1.5m.but n.exc 3m deep.
Dewatering and desludging of septic tank for 100 users including working in foul position including sprinkling bleaching powder over internal wall surfaces and upto 50cm wide from end of wall around and top of slab of septic tank including removal of sludge/liquid mud or any other obstruction material and deposting out of MOD land with the help of covered container and burried in pit and covered with 15cm layer of soil complete all as specified and as directed. Note : Rate quoted shall be inclusive for necessary excavation and earth work under this item.
All as per Serial item No. 119 here-in-before including note but for cleaning of septic tank for 50 users.
All as per Serial item No. 119 here-in-before including note but for cleaning of septic tank for 25 users.
M&L for cleaning of soak well by pumping or any suitable means, dia of soak well exceeding 2.50 m and n. exc 3.00 dia and depth not exc 3.00 complete all as directed by Engr-in-Charge.
Cleaning of septic tank for 200 users capacity in running/flowing order without disturbance by removal of all blockage of any type mechanical device system and making fully functional at any location and at any floor in the area covered by AF Stn Site C', 3AFSR, NKP and MES Area complete all as specified and directed. Notes (A) The following elements are included in the unit rate of this item)- (i) Working in foul conditions/positions. (ii) Making good the disturbed position of any during the cleaning. (iii) Removing sludge/waste material/liquid / mud/dirt/silt or other obstruction taking out through container/tanker to a distance exc 5Km and disposal off out off MOD land or as directed. (B) The scope of work comprises of cleaning, removing blockages of various item mentioned therein the entire AF Stn Site C', 3AFSR, NKP and MES Area.
Cleaning to blocked floor/nahani trap and CI/PVC pipe upto 1st manhole and removing all silt, residue sludge both organic and inorganic nature including any type of foreign materials and removing waste materials/sludge, etc. to a distance exc 50m and disposal off out off MOD land or as directed and sealing the sides of traps in bath room/kitchen using Aqua TS of Aqua shield water proofing or equivalent and making good the disturbed position of any during the cleaning to entire satisfaction of Engineer-in-Charge complete all as specified and as directed.
Cleaning to blocked WC trap and CI/PVC pipe upto 1st manhole and removing all silt, residue sludge both organic and inorganic nature including any type of foreign materials and removing waste materials/sludge etc to a distance exc 50m and disposal off out off MOD land or as directed and sealing the sides of traps in bath room/kitchen using Aqua TS of Aqua shield water proofing or equivalent and making good the disturbed position of any during the cleaning to entire satisfaction of Engineer-in-Charge complete all as specified and as directed.
Taking down 75mm/110mm bore AC/PVC rain water, soil and waste pipe, etc. from trench, walls, ceiling, etc. including fittings and fixtures complete all as specified and as directed.
S&F for 110mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints, fixed to walls, etc. complete all as specified and as directed. NOTE : Rate quoted shall deemed to be inclusive with PVC clamps, distance pieces, plugs, holder bats, etc.including cutting, jointing, etc.
All as per Serial item No. 127 here-in-before including note but of size 75mm dia
S&F as in repairs PVC (SWR) bends of size 75mm bore, any radius with access door complete all as specified and as directed.
S&F as in repairs 110mm bore PVC (SWR) branch piece, double (double 'Y'), equal or unequal with access door complete all as specified and as directed.
S&F as in repairs 110mm bore PVC (SWR) junction, double (double T) equal or unequal with access door complete all as specified and as directed.
S&F as in repairs 110mm bore PVC (SWR) bends, any radius complete all as specified and as directed.
S&F for 75mm dia cast iron floor trap, with grating including jointing to waste pipe, fixed in cement concrete (1:2:4) type B-1 (using 20mm grades stone aggregate) complete all as specied and as directed.
All as per Serial item No. 133 here-in-before but 100mm dia.
S&F as in repairs 15mm dia pillar taps, cast copper alloy with capstan heads, chromium plated, screwed down, high pressure with long screws shanks and fly nuts complete all as specified and as directed.
S&F as in repairs vitreous china wash down water closet (pedestal pattern), white, including plastic WC seat cover, white, closed pattern with flat bottom and cover, mild steel chromium plated hinging device and including chromium plated jet nozzle, hand shower type for EWC and chromium plated toilet paper holder, fixed to wall with chromium plated brass screws, including connection to GI pipe line complete all as as directed.
S&F as in repairs 15mm dia stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with capstan handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F as in repairs 15mm dia angle valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with capstan handle screwed both ends for iron pipe or for unions complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed.
M&L for non skid ceramic designer coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed.
M&L for glazed ceramic coloured tiles of size 350x250x7mm / 450x350x7mm thick, fixed in vertical surfaces, such as dado, skirtings, etc. set and jointed in neat cement slurry and pointed in white or coloured cement ot match, over a backing coat of 10mm thick in cement mortar (1:4) complete all as specified and as directed.
M&L for 75mm thick cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protections, etc. finishing the surface even and smooth without using extra cement complete all as specified and as directed.
M/s Vishnu Enterprises
Ms Jahnabi Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .