Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 CrAdmitted-Finance AT ROAD BOKAKHAT ASSAM | ₹9.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹10.1 Cr+₹42.7 L (4.41%)Admitted-Finance 4B TOWN SQUARE CHINAR PARK RAJARHAT KOLKATA 700 136 | ₹10.1 Cr+₹42.7 L (4.41%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S. M.P. AGARWALLA L1 | Tribeni Constructions Limited L2 |
|---|---|---|---|---|---|
| 1.00 | Construction of IB BUILDING
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
2.8.1 All kinds of soil. | 1,388 | Cum | 250 ₹3,47,000 Lowest | 250 ₹3,47,000 Lowest |
| 2.00 | Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over
corresponding basic item for depth upto 1.5 metre). | 694 | Cum | 190 ₹1,31,860 Lowest | 240 ₹1,66,560 |
| 3.00 | Filling available excavated earth (excluding rock) in trenches, plinth,
sides of foundations etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up
to 50 m and lift upto 1.5 m. | 1,203 | Cum | 235 ₹2,82,705 Lowest | 250 ₹3,00,750 |
| 4.00 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL
anti-termite treatment (excluding the cost of chemical emulsion) : | 664 | metre | 30 ₹19,920 Lowest | 30 ₹19,920 Lowest |
| 5.00 | Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (each layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer -in-charge, including compacting each layer by rolling/ ramming and watering, all complete as per drawing and direction of Engineer -in - charge. | 1,203 | Cum | 240 ₹2,88,720 Lowest | 300 ₹3,60,900 |
| 6.00 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) including dewatering if necessary, and curing etc. complete. | 120 | Cum | 6,300 ₹7,56,000 Lowest | 6,500 ₹7,80,000 |
| 7.00 | 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone
aggregate 40 mm nominal size) including dewatering if necessary, and curing etc. complete.
c) 100mm thick | 56 | Cum | 6,700 ₹3,75,200 Lowest | 6,800 ₹3,80,800 |
| 8.00 | Providing and laying damp-proof course 40mm thick with cement
concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural
sources : 4 graded stone aggregate 12.5mm nominal size derived from
natural sources) | 78 | Sqm | 350 ₹27,300 Lowest | 350 ₹27,300 Lowest |
| 9.00 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size,well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
(a) 50mm thick | 8 | Sqm | 700 ₹5,600 Lowest | 700 ₹5,600 Lowest |
| 10.00 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
(5.1.2) 1:1:2 (1 cement : 1 coarse sand (zone-III): graded stone aggregate 20 mm nominal size)
M25 grade concrete | 338.36 | Cum | 8,200 ₹27,74,552 | 8,000 ₹27,06,880 Lowest |
Tender Value
₹9.7 Cr
EMD Value
₹19.4 L
Closing Date
3 Nov 2022, 2:00 pmClosed
Chief Engineer, PWD, Roads, Assam, Chandmari, Ghy
O/o the Chief Engineer, Roads,PWRD Assam, chandmari, Guwahati-781003
SOPD_G_21_22_48 Construction of New Inspection Bunglow, Grade IV Quarter and Repairing of Existing Multistorey IB at Bokakhat under PWRD, under SOPD-G for the year 2021-2022, Bokakhat LAC
2022_PWD_27438_1
CE/DEV/TB/369/2021-22/07
Open Tender
Civil Works
Item Rate
540 days
Bokakhat
Please refer Tender documents.
6 documents required · 6 mandatory
₹19,380
₹19.4 L
Yes
O/o the Chief Engineer, Roads,PWRD Assam
15 Nov 2022
22 Oct 2022
4 Nov 2022
22 Oct 2022
3 Nov 2022
26 Oct 2022
22 Oct 2022 - 25 Oct 2022
25 Oct 2022
Amount
Construction of IB BUILDING Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre).
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :
Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (each layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer -in-charge, including compacting each layer by rolling/ ramming and watering, all complete as per drawing and direction of Engineer -in - charge.
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) including dewatering if necessary, and curing etc. complete.
1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) including dewatering if necessary, and curing etc. complete. c) 100mm thick
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size,well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (a) 50mm thick
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (5.1.2) 1:1:2 (1 cement : 1 coarse sand (zone-III): graded stone aggregate 20 mm nominal size) M25 grade concrete
Reinforced cement concrete work in beams, suspended floors,column, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1:2 (1 cement : 1 coarse sand(zone-III) : 2 graded stone aggregate 20 mm nominal size). M25 grade concrete
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete
Providing form work of 19mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:Columns, Pillars, Piers, Abutments, Posts and Struts
Lintels, beams, plinth beams, girders, bressumers and cantilevers (a) For depth not exceeding 1.0M.
Suspended floors, roofs, landings, balconies and access platform (a) Floors etc. upto 200mm in thickness.
Stairs, (excluding landings) except spiral-staircases
Providing form work of 19mm thick Plywood board and removal of the same in edges of slabs and breaks in floors and walls etc. of in-situ reinforced concrete works upto first floor level. (a) Thickness not exceeding 200mm.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above and below plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:(d). In proportion 1:6.(1 cement:6 sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.3 Electric resistance or induction butt welded tubes
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. WATER PROOFING OF CHAJJAS, ROOF SLABS, TERRACES, SEPTIC TANK,OH TANK, RAFT SLAB IN BASEMENT, WALLS ETC.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement:5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 8.2.1 Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble Area of slab OVER 0.50 sqm
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Marble work
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement:4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm
Glazed vitrified floor tiles polished finish of size Size of Tile 600 x 1200 mm
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3 kg/ sqm including grouting thejoints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm ( HIGH GLOSS)
Providing and laying Ceramic glazed wall tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement:4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size 11.41A.1.1 Size of Tile 600 x 600 mm
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 11.6.1 18 mm thick
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.
12 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. 13.1.1 1:4 (1 cement: 4 fine sand)
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side 13.2.1 1:4 (1 cement: 4 fine sand)
20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick) 13.3.1 1:4 (1 cement: 4 fine sand)
White washing with lime to give an even shade : 13.37.1 New work (three or more coats)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 13.48A.1 New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Sal wood
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 2nd class teak wood 9.40.1.2 50 x 20 mm
Providing and fixing factory made laminated veneer lumber glazed shutter conforming to IS: 14616 and TADS 15:2001 (Part B), using 4 mm thick float glass panes for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, all as per directions of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 30 mm thick shutters
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300mm x 16mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250mm x 10mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper
Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket,G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.147B.1 Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ±0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)
Providing and fixing factory made uPVC white colour sliding glazed window above 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads, uPVC extruded interlocks and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle on one side of extreme panel along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) touch lock with hook (if required for wire mesh panel), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, ncluding drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. 9.147E.1 Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 2.50 sqm upto 4.00 sqm.)
Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. 9.147F.4 Three track three panels sliding door with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm)
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.
Providing and fixing glazing in fire resistant door shutters, fixed panels& partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet(zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 60 minutes of fire resistance both integrity & radiation control (EW60) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
Providing and fixing fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing accessories in all colours with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete: Ventilator curves
Providing and fitting RUBBER FLOORING IN GYM AREA
Providing and fittingWHITE PEBBLES FOR LANDSCAPE AREA
Construction of Grade IV QUARTER Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m 2.8.1 All kinds of soil.
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre).
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (each layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after everyfour layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer -in-charge, including compacting each layer by rolling/ ramming and watering, all complete as per drawing and direction of Engineer -in - charge.
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) including dewatering if necessary, and curing etc. complete.
1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) including dewatering if necessary, and curing etc. complete. c) 100mm thick
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size,well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (a) 50mm thick
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (5.1.2) 1:1: (1 cement : 1 coarse sand (zone-III): 2 graded stone aggregate 20 mm nominal size) M25 grade concrete
Reinforced cement concrete work in beams, suspended floors,column, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1:2 (1 cement : 1 coarse sand(zone-III) : 2 graded stone aggregate 20 mm nominal size). M25 grade concrete
Add for plaster drip course/ groove in plastered surface or moulding toR.C.C. projections.
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Providing form work of 19mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Columns, Pillars, Piers, Abutments, Posts and Struts
Lintels, beams, plinth beams, girders, bressumers and cantilevers (a) For depth not exceeding 1.0M.
Suspended floors, roofs, landings, balconies and access platform (a) Floors etc. upto 200mm in thickness.
Stairs, (excluding landings) except spiral-staircases
Providing form work of 19mm thick Plywood board and removal of the same in edges of slabs and breaks in floors and walls etc. of in-situ reinforced concrete works upto first floor level. (a) Thickness not exceeding 200mm.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above and below plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (d). In proportion 1:6.(1 cement:6 sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level Cement mortar 1:6 (1 cement : 6 coarse sand
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate TILES WORKS CERAMIC GLAZED TILES A) ON FLOOR
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm
12 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. 13.1.1 1:4 (1 cement: 4 fine sand)
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side 13.2.1 1:4 (1 cement: 4 fine sand)
20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick) 13.3.1 1:4 (1 cement: 4 fine sand)
White washing with lime to give an even shade : 13.37.1 New work (three or more coats)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 13.48A.1 New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Kiln seasoned and chemically treated hollock wood
Providing and fixing factory made laminated veneer lumber glazed shutter conforming to IS: 14616 and TADS 15:2001 (Part B), using 4 mm thick float glass panes for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, all as per directions of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 30 mm thick shutters
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300mm x 16mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250mm x 10mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper
Installation of Electrical Works in IB BUILDING Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc Group C
Wiring for group controlled (looped) light point/fan int/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. CIRCUIT / SUBMAIN WIRING 2x1.5 sq mm + 1x1.5 sq mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. CIRCUIT / SUBMAIN WIRING 2x2.5 sq mm + 1x2.5 sq mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. CIRCUIT / SUBMAIN WIRING 4x2.5 sq mm + 2x2.5 sq mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. CIRCUIT / SUBMAIN WIRING 2x6 sq mm + 1x6 sq mm earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. CIRCUIT / SUBMAIN WIRING 2x10 sq. mm + 1x6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. CIRCUIT / SUBMAIN WIRING 2x16 sq. mm + 1x6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. CIRCUIT / SUBMAIN WIRING 4x6 sq mm + 2x6 sq mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. CIRCUIT / SUBMAIN WIRING 4x10 sq mm + 2x6 sq mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. CIRCUIT / SUBMAIN WIRING 4x16 sq mm + 2x6 sq mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV anteena Socket Outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Bell push
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm) - For TV outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm) - For Socket outlet.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 Way, Double Door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 Way, Double Door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 6 Way (4+18), Double Door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 8 Way (4+24), Double Door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C series Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc,as required. Single pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C series Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc,as required. Single pole and neutral
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C series Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc,as required. Triple pole and neutral
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amp
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amp
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amp
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amp
Supplying and fixing of following rating double pole (Single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a current sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required. 25 Amp
Supplying and fixing of following rating double pole (Single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a current sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required. 40 Amp
Supplying and fixing of following rating double pole (Single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a current sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required. 63 Amp
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm dia
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm dia
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm dia
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supply, erection, testing and commissioning of following sizes of splitter of aluminium die cast body in suitable size of G.I. Box. 8 way
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single corecable etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting/ LED fittings of all types, complete with all accessories and tube/lamp/ LED etc. directly on ceiling/ wall/ false ceiling with GI Chain included for fixing wherever required, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet (near equipment point) and 25 A modular SP MCB, “C” curve (at accessible point) including connections, painting etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supply & Laying of following sizes of 1.1KV grade multistranded copper conductor FRLS insulated wire including termination complete as required in existing cable tray. 1C x 16 sq.mm PVC Insulated cu wire including end termination. ( for UPS)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 120 mm dia (OD-120 mm & ID-103 mm nominal)
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
Supply of 2W LED Step light with electronic high efficiency electronic driver as complete as required (Philips Make, Cat no-30974) or equivalent.
Supply of 12 watt LED Wall Brakect Light.with electronic high efficiency electronic driver as complete as required (Philips Make, Cat no-32032/11) or equivalent.
Supply of 9 / 10 watt LED Recess Down Light.with electronic high efficiency electronic driver as complete as required (Philips Make, Cat no-DN 392B LED10S-6500 PSU WH) or equivalent.
Supply & Installation, Testing & Commissioning of LED STRIP Light (Approved Make- Philips Cat No: LS170S LED12 827 IP20 L5000) or equivalent
Supply of 9/10 watt Ceiling SURFACE MOUNTED Spot with electronic high efficiency as complete as required. (Philips Make, 53090/31/P0 | /48/P0) or equivalent.
Supply of Regalia Machine pressed clear glass G9, 12x42 Watt LED chandelier light (Philips Make, 581853) or equivalent.
Supply of Mushroom Clear curving glass mushroom strip G9, 6x42 Watt LED chandelier light (Philips Make, 581862) or equivalent.
Supply of following sizes of heavy duty exhaust fan for single phase 230 volt, 50HZ AC supply complete with motor, blades, frame, bracket, louver/ shutter etc as required. (HavellS Make, Cat No - Ventil Air - DX White or equivalent). 250 mm Exhaust Fan (1500 RPM).
Supply of following sizes of ceiling fan complete with double ball bearing, motor, blades, downrod, canopy, capacitor etc. suitable for operation on 230 volt, 50 Hz, A.C. supply complete as required. (Havells Make, Cat No-Efficiencia Neo (BLDC 26 W) or equivalent.) 1200 mm Ceiling Fan
Supply of following sizes of wall fan complete with double ball bearing, motor, blades, capacitor etc. suitable for operation on 230 volt, 50 Hz, A.C. supply complete as required. (Havells Make, Cat No-swanky or equivalent.) 400 mm wall Fan
Supply, Installation, Testing & commissioning of outdoor based Bollard fixture for landscape lighting solution. The fixture should have aluminium extrusion housing with PC Cover. The fixture should give a minimum system lumen output of 340 lumens and maximum system wattage of 10 Watt. The fixture shall have a CRI of minimum 75 CCT of 4000K. The fixture shall be designed for a system life of 25,000 hours @L80B10. Ingress Protection of IP65 and Mechanical Impact Resistance Rating of IK >=10.The fixture driver should have an operating voltage range of 220-240 V, Ambient temperature range -20 to +40 °C PF >0.9 , and SDCM<5. the luminire should give two color temperature of 4000K. . (Make: Philips Cat No.-BCP151/LED150/NW DXH=180X800 or similar equivalents)
Supply, Installation, Testing & commissioning of LED based Street light, housing made up of Pressure Die Cast Housing LM 6 Alloy/ Anti Dust Exposed Lens,sturdiness and embossed brand name/logo name of manufacturer. The fixture should have a minimum system efficacy of 115 lumen/Watt and a minimum system lumen output of 5300 lumens and maximum system wattage of 45 Watts.The fixture shall have a CRI of minimum 70. The fixture shall be designed for a system life of 50,000 hours @70% lumen maintenance. Ingress Protection of IP66 (lamp and gear Compartment) and Mechanical Impact Resistance Rating of IK08.The fixture driver should have an operating voltage range of 140-270 V, inbuilt surge protection of >=4KV(additionally 10KV external also available), PF >0.95 , and SDCM<5. The driver should be BIS approved, fully potted and encapsulated with 440V Stress Voltage protection for 8 Hrs. High Cut off : 325V(+/- 15V) and Auto Restart function should also be available within the fixture..The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. (Make: Philips Cat No.-BRP052 LED 036 CW HP SLA FG S1 PSU GR or similar equivalents)
Supply, Installation, Testing & commissioning of 4.5m Hight MS Poles, PU painted, including base plate & 600mm arm length, polyurethane paint (Color as approved), single arm.
Supply, Installation, Testing & commissioning of planter spike light in max 8W LED with minimum 550lm and efficacy of more than 65lm/W; die cast aluminium housing; optics with medium beam of 20/45 degree, CCT 3000K; CRI>80; Input voltage of 100-240V; 50/60 Hz rated frequency; should be IP65 rated or higher; SDCM<5 or less. IP65; IK08 rated protection or higher. should have saltprotectioon of at least 165 hrs with lifespan of 15k hrs@L70B50. Luminaire should be NABL/ BIS certified. (Make: Philips BGP150 or similar equivalents)
Supply & Installation, Testing & Commissioning of LED Post Top Light Reliable and aesthetic designed IP65 post top lantern with symmetric light distribution and limited upward light component. (Approved Make- Philips Cat No: BGP161 LED2500/NW PSU 220-240V 7043 IN) or equivalent
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 run of cable
Supply, Installation, Testing & Commissioning of Cat 6, 24 Port Patch Panel. (Approved Make-Dlink/Legrand)
Supply, Installation, Testing & Commissioning of CAT6 Patch Cord 6 feet for rack and user end termination -2 Mtr (Approved Make-Dlink/Legrand)
Supply, Installation, Testing & Commissioning of Cat 6 patch cord 3 feet for rack and user end termination - 1Mtr (Approved Make-Dlink/Legrand)
Supply, Installation, Testing, Commissioning of Cat 6, Information Outlet (I/O) including G.I. Box and modular cover plate. (Approved Make-Dlink/Legrand)
Supply , Installtion , Testing and comissioning of 27 U wall mount rack with fans , 2 cable managers, satationary shelf , 2 Nos of hardware pkts as per technical specification.
Supply, Installation, Testing & Commissioning of 24 port 10/100/1000Mbps, 4SFP module, L-2 Switch, POE. (Approved Make-Dlink/Legrand)
Supplying Installation, Testing and Commissioning of Server Based EPABX Fully Computerized IP System, Multi slot 19: U Rack Mountable 2U Rack Presently Configuration as Below: CO Line 01 Nos. PRI(30 Channel) 01 Nos. Extension 01 Nos. Digital Extension Circuits 01 Nos. Analog Extension 30 Nos (Approved Make-Matrix/Alcatel)
Supply and installation of wire manager suitable for mounted on 19 inch rack.
Supply Installation, Testing and Commissioning of Digital Key Phone Programmable Display: 240x64 Pixels Graphical LCD with Backlit Polyphonic Ringtone, Full Duplex Speaker Phone, Hold, Conference, Redial, Transfer, Message Wait Lamp. (Approved Make- Matrix /Beetel).
Supply, Installation, Testing & Commissioning of 6 Core OM4 Multimode Fiber Cable as per technical specification.
Supply, Installation, Testing & Commissioning of wifi Access point as complete as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 run of cable
Supplying, installation, testing & commissioning of 2MP Fixed Dome Network Camera High quality image 1/2.8" CMOS sensor 1920*1080)@30/25fps; 720P (1280*720)@30/25fps Ultra 265, H.265, H.264 Smart IR, up to 30m (98ft) IR distance Day/night, Adjustment angle Rotate: 0° ~ 360°, DWDR, Privacy Mask Up to 4 areas, White Balance Auto/Outdoor/Fine Tune/ Sodium Lamp/Locked/Auto2, Digital noise reduction 2D/3D DNR, Flip Normal/Vertical/Horizontal/180°, HLC Supported BLC Supported, Network 10/100M Base-TX Ethernet, CE: EN 60950-1 UL: UL60950-1 FCC: FCC Part 15. (Approved Make- Honeywell / Tyco / Uniview)
Supplying, installation, testing & commissioning of 2MP HD IR VF Bullet Network Camera, 1/2.7", 2.0 megapixel, progressive scan, CMOS, Lens 2.8 ~ 12mm, AF automatic focusing and motorized zoom lens, DORI Distance, Lens 12(mm) 180Detect (m) 72Observe (m) 36Recognize (m) 18Identify (m), Adjustment angle Rotate: 0° ~ 360°, IR Range Up to 50m (164ft) IR range, Day/Night IR-cut filter with auto switch (ICR), Privacy Mask Up to 4 areas,White Balance Auto/Outdoor/Fine Tune/Sodium Lamp/Locked/Auto2, HLC Supported, BLC Supported,Edge Storage Micro SD, up to 128GB, Network 10/100M Base-TX Ethernet, Built-in Mic Supported, Material metal , Ingress Protection, IP67, Certifications, CE: EN 60950-1 UL: UL60950-1 FCC: FCC Part 15. (Approved Make- Honeywell / Tyco / Uniview)
Supply, installation, testing and commissioning of Professional NVR with 24 -- 64 CH video input as required for Camera mentioned above.Third-party network cameras supported, H.264 Compression - recording, Hard Disk of minimum 2 TB as required for viewing @ 25 Frames per second and one megapixel resolution (Real Time). HDD quota and group management, multiple SATA interfaces, USB 2.0 , Recording on Motion, Scheduled, HTTP Networkable, backup by USB/DVDWR, 3rd ONVIF Video management & recording software, complete as per tender specifications and as required
Supply, installation, testing and commissioning of of 6 TB HDD all accessories complete as required.
Supply ,installation, testing and commissioning of networking switch with 12 ports managed, 10/100/1000 GB Layer 2 / 3 switches to support all cameras , with Fibre port and Fibre module complete as required
Supply, installation, testing & commissioning with 27U rack for switch Mounting with Fan and power Strip, PDU, Hardware Mounting Kit
Supply, Installation, Testing and Commissioning of Ultra HD 43" LED Smart TV . Approved (Makes: Panasonic, Sony, Samsung.)
Supply, Installation, Testing & Commissioing of 15 KVA UPS in paralleling mode at 0.99 input power factor with SNMP card, compatible for BMS connectivity on backnet/MODBUS, Inbuilt Isolation transformer as per specification given in the document with following broad features. THD(i) shall be less than 3% in the entire loading range. UPS shall carry design output at 40 deg. Shall have soft start and hold of for incoming supply. Invertor capability to supply 150% load for 5 sec. Three Phase Input and Three Phase Output. (Input - 340V - 470V, Three Phase, 4 wire. / Output - 400-415 Volt, Three Phase, 4 Wire.) Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells. Battery shall be external type with rack and suitable for 15 minute backup on 100% load. Suitable size of copper cable between UPS and battery bank shall be provided UPS described as above
Design, manufacture, supply, installation, testing and commissioning of 200 KVA, 11 KV /0.415 KV, 3 phase, 4.5 % impedance, 50 Hz delta/star-11 connected, outdoor type, copper wound transformer, oil immersed ONAN cooled, complete with all fittings such as oil conservator, silica gel breather, thermometer, explosion vent with off Load Tap changing arrangement on HV side with Tapping for variations of high voltage from (+) 5% to (-) 10% in steps of 2.5% each, bi-directional roller, diagrams & rating plate, Oil temperature indicator, & Winding temperature indicator, weather proof Marshalling Box, lifting lugs, first filling of oil, weather proof H.T/L.T cable box etc. complete as per specification. All relays, contacts & CT terminals to be wired upto marshalling box. The Transformer losses should confirm to IS - 1180 Part-1 (2014) with energy efficiency level 2 [0.78 KW at 50% load & 2.23 KW at 100% load shall not exceeds by 5.0% (@ 11 KV) of the maximum total loss values.
Supply, Installation, testing and Commissioning of Silent type Diesel Generating Set at 0.8 PF, 415 Volts, 50 cycles per second, 1500 rpm, 3 phase, suitable for parallel operation / PLC based synchronization, 0.85 load factor including circuit breaker for isolation, sound proof acoustic and weather proof enclosure, residential type silencer (as per CPCB norms-2) fabricated out of CRCA sheet of 14 / 16 SWG thickness with 9 tank pretreated before powder coating with ventillation system complete in all respects comprising of the following. Diesel Engine - Diesel Engine suitable for driving alternator of above rating, compression ignition, 4 stroke cycle, Radiator cooled, turbo charged, battery starting, 1500 RPM, suitable for above output of alternator at 40oC, 50% RH & at 210 M MSL and confirming to BS 5514, BS 649, IS 10000, capable of taking 10% overloading for one hour after 12 hrs of prime continuous loading, complete with all the accessories i.e. tachometer with hour meter, flexible coupling with guard, crank case of steel, crank shaft, conncting rods, electronic governing system, dynamically balanced flywheel, air intake manifold, Air cleaner, anti vibration pads, starter motor, including all other accessories required to complete the system. Instrument Panel - Engine mounted Instrument Panel fitted with and having digital display for followings : Start stop switch with key Water temperature indication Lubrication oil pressure indication. Lubrication oil temperature indication. Battery charging indication RPM indication Over speed indication Low Lube oil trip indication Engine hours indication Alternator - Synchronous Alternator of above capacity at 0.8 PF, 3 phase, 415 volts, 50 cycles, 4 wire, 1500 RPM, suitable for operation at 40 deg C, 50% RH & at 210 meter above MSL, capable of taking 10% overlioading for one hour after 12 hrs of prime continuous loading, brushless, self excited, self regulated through AVR, continuous duty confirming to IS 4722, BS 2613 suitable for tropical conditions, class H insulation, including terminal box suitable for cable termination as required. Base Frame - Both the engine and alternator shall be mounted on suitable base frame made of MS channel which shall be installed on cement concrete foundation and vibration isolating arrangement as per recommendations of manufacturer. Inbuilt Fuel tank of standard capacity complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, fuel transfer system for automatic fuel refilling system with pump, piping, valves, level indicators etc. complete. Daily service Fuel tank of 990 liters capacity fabricated out of 2 mm thick MS sheet complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, provision for fuel transfer system, level indicators and all standard accessories etc. as required. Exhaust Silencer - Exhaust manifold with residential silencer. The D G set should be supplied with required hardware for external PLC based auto synchronization, auto load sharing, auto load management system. Starting system - 24 Volt DC starting system comprising of starter motors : voltage regulator and arrangement for initial excitation complete with 24 Volts suitable nos. lead acid type batteries of suitable AH. Ventillation System - Arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per standard specifications. 100 KVA
Supply, Fixing, testing and Commissioning of Exhaust gas piping system of Class `B' MS pipe as per IS:1239 for upto 150 mm dia and for 200 mm dia & above MS pipe as per IS:3589 with welded joints, cut to required lengths with necessary bends, fittings, flanges, painting over primer coat, with rock wool insulation of minimum 75 mm thick of 150 Kg per cu M density on all sides of exhaust pipe, with chicken mesh wrapping and 26 SWG aluminium sheet cladding complete as required. The aluminum foil should be tightly cladded to insulation surface of pipe. The aluminum cladding shall be locked with sheet metal screws with other sections of aluminium foil. The measurement shall be done on the basis of centre line. (Stack height should be in accordance with emission regulations of CPCB, which will go well above the top most terrace) The exhaust piping system should be suitable for upto 550oC temperature, the surface temperature of exhaust pipe shall not exceed more than 60oC. (The rates are exclusive of support structure) (Note - Final size of exhaust pipe will be confirmed by the DG vendor after calculating the actual back pressure and submit the same to client / consultant for approval) 100 mm dia (wall thickness - 4.5 mm)
Supply & fabrication of D G exhaust pipe supports by M.S angle iron of size not less than 100 x 50 mm x 6/8 mm duly grouted in the wall through minimum 8 mm thick plate and with suitable MS angle / channel iron structure. The entire MS support structure should be painted by 2 coats of anti corrosive paint over primer coat of approved shade and make. The design of support to be duly approved by the Structural Consultant / Architect before fabrication and installation.
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, installation, testing & commissioning of 14 SWG CRCA sheet steel fabricated cubical type Main L.T. Panel with AMF, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 52, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. FRLS copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623 . The panel feeders shall be suitable for terminating suitable nos. 3.5 / 4 core armoured aluminium cable or Aluminium Bus Duct The item must stasify all approved specifications as per the sanctioned estimate.
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, installation, testing & commissioning of 14 SWG CRCA sheet steel fabricated cubical type 75 KVAR A P F C Panel consisting of 5 / 10 / 25 KVAR (at 415 Volts rated voltage of bank shall be 440 Volts) capacitor units in tier formation, housed in an integrated cubicle type automatic switching ON and OFF control panel, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 52, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623 . The item must stasify all approved specifications as per the sanctioned estimate.
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 3C x 185 Sqmm, 11KV XLPE
Supplying of 11 KV grade aluminium conductor, cross linked polyethylene (XLPE) insulated individual core screened, flat steel/strip armoured PVC sheathed cable complete as required. 3C x 185 Sqmm, 11 KV XLPE
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm
Supply of following sizes of 1.1KV grade Copper conductor XLPE insulated and FRLS PVC sheathed armoured control cable including termination conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant). 4 core, 2.5 sq.mm.
Supply of following sizes of 1.1KV grade Copper conductor XLPE insulated and FRLS PVC sheathed armoured control cable including termination conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant). 10 core, 2.5 sq.mm.
Supply of following sizes of 1.1KV grade Copper conductor XLPE insulated and FRLS PVC sheathed armoured control cable including termination conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant). 12 core, 2.5 sq.mm.
Supplying & Placing of First aid box as approved by St.John Ambulance Brigade /Indian Red Cross society conforming to IS : 2217 - 1963 etc as reqd.
Supplying & Installation of Shock treatment chart duly mounted on a wooden frame with glass on, as required in 2 languages (Hindi & English) etc. as reqd
Supplying and Laying of Rubber mat 1000 mm. Wide to withstand 1.1 KV dielectric strength as per latest IS 15652-2006 etc. as reqd.
Supplying and Laying of Rubber mat 1000 mm. Wide to withstand 11 KV dielectric strength as per latest IS 15652-2006 etc. as reqd.
Supply of following sizes of 1.1KV grade aluminium conductor XLPE insulated and FRLS PVC sheathed armoured cable conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant). 3½ core, 240 sq.mm.
Supply of following sizes of 1.1KV grade aluminium conductor XLPE insulated and FRLS PVC sheathed armoured cable conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant). 3½ core, 70 sq.mm.
Supply of following sizes of 1.1KV grade aluminium conductor XLPE insulated and FRLS PVC sheathed armoured cable conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant). 3½ core, 50 sq.mm.
Supply of following sizes of 1.1KV grade aluminium conductor XLPE insulated and FRLS PVC sheathed armoured cable conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant). 3½ core, 35 sq.mm
Supply of following sizes of 1.1KV grade aluminium conductor XLPE insulated and FRLS PVC sheathed armoured cable conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant). 4 core, 16 sq.mm
Supply of following sizes of 1.1KV grade aluminium conductor XLPE insulated and FRLS PVC sheathed armoured cable conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant). 4 core, 10 sq.mm
Supply of following sizes of 1.1KV grade aluminium conductor XLPE insulated and FRLS PVC sheathed armoured cable conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant). 4 core, 6 sq.mm
Supply of following sizes of 1.1KV grade aluminium conductor XLPE insulated and FRLS PVC sheathed armoured cable conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant). 2 core, 16 sq.mm
Supply of following sizes of 1.1KV grade aluminium conductor XLPE insulated and FRLS PVC sheathed armoured cable conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant). 2 core, 6 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with cable tie)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required Above 35 sq. mm and upto 95 sq. mm (clamped with cable tie)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required Above 95 sq. mm and upto 185 sq. mm (clamped with cable tie)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required Above 185 sq. mm and upto 400 sq. mm (clamped with cable tie)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 6 sq. mm (19mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 16 sq. mm (22mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm) (The Termination including 4 x 6 sq. mm cable)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm (32mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 50 sq. mm (35mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 70 sq. mm (38mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 240 sq. mm (62mm)
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm wide x 50 mm depth x 1.6 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm wide x 50 mm depth x 1.6 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm wide x 50 mm depth x 1.6 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm wide x 50 mm depth x 1.6 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm wide x 50 mm depth x 1.6 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm wide x 50 mm depth x 1.6 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. 150 mm wide x 50 mm depth x 1.6 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. 300 mm wide x 50 mm depth x 1.6 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm wide x 50 mm depth x 1.6 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm wide x 50 mm depth x 1.6 mm thickness.
Supply, Installation, Testing & Commissioning of DLP Solid state(Laser Phosphor) Projection system with ultra short throw lens maximum throw ratio 0.25 UST having 5000 Lumens, 3D available, 1920 x 1200 Resolution,1800:1 Contrast Ratio, illumination Life 20000 hours, Inputs: HDMI, HDBaseT should be complete with Mounting arramgement for projector etc complete as required. (Approved makes: Christie / Sony / NEC). (For conference Room)
Supply, Installation, Testing & Commissioning of motorised screen size 120"with mounting and arrangement etc complete as required. Approved makes: Custom (For conference Room)
Supply, Installation, Testing & Commissioning ofof 1-chip DLP LASER Phosphor Multimedia Projection system having, 9500 Lumens 20000 hours lamp life, 1920 x 1200 WUXGA Native Resolution, Inbuilt blending and warping with automatic caliberation software, 3D ready, 1200000:1 Contrast Ratio, inputs: HDBaseT,HDMI2.0, DVI-D, Active 3D, Motorised zoom and focus, alongwith maximum 0.65-0.75 lens & projector Mounting arramgement for projector etc complete as required. (Approved makes: Christie / NEC / Sony) (For Multipurpose Hall)
Supply, Installation, Testing & Commissioning of of screen size 250"with mounting and arrangement etc complete as required. Approved makes: Custom (For Multipurpose Hall)
LIFT : 8 Passenger,1,5 m/sec, travel height G+5
ELECTRICAL ESTIMATE - IV GRADE QUARTER: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. CIRCUIT / SUBMAIN WIRING 2x1.5 sq mm + 1x1.5 sq mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. CIRCUIT / SUBMAIN WIRING 2x2.5 sq mm + 1x2.5 sq mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. CIRCUIT / SUBMAIN WIRING. 4x2.5 sq mm + 2x2.5 sq mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. CIRCUIT / SUBMAIN WIRING. 2x10 sq. mm + 1x6 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV anteena Socket Outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Bell push
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm) - For TV outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm) - For Socket outlet.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 Way, Double Door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C series Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc,as required. Single pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amp
Supplying and fixing of following rating double pole (Single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a current sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required. 40 Amp
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm dia
Supply, erection, testing and commissioning of following sizes of splitter of aluminium die cast body in suitable size of G.I. Box. 8 way
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single corecable etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting/ LED fittings of all types, complete with all accessories and tube/lamp/ LED etc. directly on ceiling/ wall/ false ceiling with GI Chain included for fixing wherever required, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supply of 12 watt LED Wall Brakect Light.with electronic high efficiency electronic driver as complete as required (Philips Make, Cat no-32032/11) or equivalent.
Supply of following sizes of heavy duty exhaust fan for single phase 230 volt, 50HZ AC supply complete with motor, blades, frame, bracket, louver/ shutter etc as required. (HavellS Make, Cat No - Ventil Air - DX White or equivalent). 250 mm Exhaust Fan (1500 RPM).
Supply of following sizes of ceiling fan complete with double ball bearing, motor, blades, downrod, canopy, capacitor etc. suitable for operation on 230 volt, 50 Hz, A.C. supply complete as required. (Havells Make, Cat No-Efficiencia Neo (BLDC 26 W) or equivalent.) 1200 mm Ceiling Fan
ESTIMATED COST OF PLUMBING WORK GUEST HOUSE ONLY: Providing and fixing white vitreous china extended wall mounted water closet of size 350 X 545 X 380mm of approved shape including providing and fixing of concealed cistern with duel flush fitting (2.0/4.0 lts. per flushing), including sheet cover, and cistern fittings, nut bolt gasket,chair etc complete. ( MAKE-1: JAQUAR, MODEL NO. WALL MOUNTED WC : FLS-WHT-5953 & CISTERN & FACE PLATE : JCS-WHT-2400SG & JCP-CHR-152415 OR EQUIVALENT.)
Supplying , fitting and fixing vitreous white glazed earthen ware I.W.C of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I 'p' trap 15 liters C.I.pull and let go flushing cistren of names or other I.S.S. equivalent make , complete with all fitting , C.I.or C.C. brackets 32mm alkathene/P.V.C telescopic flush , pipe about 2 M long with one brass coupling and clamps GI ,chain and pull including supplying and fixing a pair of vitreous white glazed earthenware ware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less thane 50grms. 15mm P.V.C. connection pipe 450 mm. long and the exposed pipe and cistern with two coats of approved paint over a coats of red oxide primer etc. all complete as per specification and direction of E/I. (A) 580 mm. long (b) With 12.5 lit. low level C.I. Cistem
Providing and fixing white vitreous china Oval shaped wash basin for top/under counter mounting with 15 mm C.P. brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls whereever required. ( MAKE-1: JAQUAR, MODEL NO. WASH BASIN : FSS-WHT-29601 & BASIN MIXER : FLR-CHR-5001BG & WASTE COUPLING : ALD-CHR-705 OR EQUIVALENT.) White Vitreous China Oval shaped Wash basin size 545 x 545 x 180mm with 15mm CP Brass single hole basin mixer with flow rate 2.5 litre per minute at 3 bar .
Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board 510x1040 mm bowl depth 250 mm
Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink without drain board 610x510 mm bowl depth 200 mm
Providing and fixing hand shower (Health faucet) with 1.2mtr long with 8mm dia Easy Flex Tube with wall hook and flow restrictor with flow rate 6 litre per minute at 3 bar in chrome finish and wall hook. ( MAKE-1: JAQUAR, MODEL NO. HEALTH FAUCET : ALD-CHR-573GA OR EQUIVALENT.)
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. ( MAKE-1: JAQUAR, MODEL NO. BOTTLE TRAP : ALD-CHR-769L300X190 OR EQUIVALENT.) Wall mounted WC Pan-01 no. with built in Jet of Make -1: Jaquar, Model No. VGSWHT81751P Concealed Cistern Cistern-01 no. of Cera CAT no. Make - 1: Jaquar, Model No. VGSWHT81201 Soft Close Seat Cover -01 no of Make 1: Jaquar Make Seat Cover of VGSWHT81751P Wall hung Wash Basin -01 no of Make 1: Jaquar Model No. CNSWHT801 Spatula Single lever Make 1: Jaquar, Model No. FLRCHR5033B Wall mounted Grab bar 600 mm long - 2 nos of Make 1: Jaquar, Model No. WACWHTBR0600 Wall mounted Hinged hand rail 750 x 100-01 no Make 1: Jaquar, Model No. WACWHTBG0800 Bottle Trap Make 1: Jaquar, Model No. ALDCHR769L300X190 Waste Coupling Make 1: Jaquar, Model No. ALDCHR705 Stainless soap dish Make 1: Jaquar, Model No. AECESS1131 Tissue paper holder Make 1: Jaquar, Model No. ACNCHR1151N
Providing & fixing PVC waste pipe for sink including PVC waste fitting Complete Flexible Pipe 40mm Dia
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing & fixing toilet paper holder C.P. brass
Providing and fixing soil waste and vent pipes 100 mm dia. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing soil waste and vent pipes 75 mm dia. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing M.S. holder-bat clamps of approved design to sand cast iron/ centrifugally cast iron(spun) pipes embedded in and including cement concrete blocks 10x 10 x 10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls, etc. For 100mm dia pipe
Providing and fixing M.S. holder-bat clamps of approved design to sand cast iron/ centrifugally cast iron(spun) pipes embedded in and including cement concrete blocks 10x 10 x 10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls, etc. For 75mm dia pipe
Providing and fixing bend of required degree with access door insertion rubber washer 3mm thick, bolts and nuts complete Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 100 mm dia
75 mm dia Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing plain bend of required degree: 100 mm dia Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
75 mm dia Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing double equal plain junction of required degree. 100 x 100 x 100 x 100mm Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing single equal plain junction of required degree. 100 x 100 x 100mm Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
75x75x75 mm Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing single unequal plain junction of required degree : 100x100x75 mm Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing terminal guard 100 mm Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe 100 mm SS 304 grade coupling with EPDM rubber gasket
Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe 75 mm SS 304 grade coupling with EPDM rubber gasket
Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipe of diameter: 100mm
Providing and fixing trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent, arm complete, including cost of cutting and making good the walls and floors. 100mm inlet and 100mm outlet Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing M.S. holder bat clamp of approved design to sand cast iron/ cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5 mm flat of specified shape, projecting 75 mm outside the wall surface and fixed on wall with 4nos, 6mm dia expansion hold fasteners, including drilling necessary holes in brick wall/ CC/RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30 mm x1.6 mm galvanised M.S. flats of specified shape and of total length 420 mm and shall be fixed with M.S. nuts, bolts, & washers of size 25x6 mm, one bolts on each side of the pipe. Total bracket length 580 mm of approved shape and design (for single 100 mm dia pipe)
Total bracket length 810 mm of approved shape and design (for two 100 mm dia pipes)
Total bracket length 1040 mm of approved shape and design (for three 100 mm dia pipes)
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing, fixing, jointing, testing and commissioning PVC (Class III) of pressure rating 6.0 kg/sqcm Rain water downtake pipe conforming to IS:4985 cut to required lengths including all necessary fittings and specials. Fixing at wall/ceiling level supported by galvanized steel clamps & hangers etc. as required for proper seismic loading as per the calculations. Making proper connection with cement solvent joint as per BIS / manufacturer. Cutting chases/holes in floors / walls / slab. (All Down take RWP & balcony Drain pipe only). 75 mm diameter pipe
Providing, fixing, jointing, testing and commissioning PVC (Class III) of pressure rating 6.0 kg/sqcm Rain water downtake pipe conforming to IS:4985 cut to required lengths including all necessary fittings and specials. Fixing at wall/ceiling level supported by galvanized steel clamps & hangers etc. as required for proper seismic loading as per the calculations. Making proper connection with cement solvent joint as per BIS / manufacturer. Cutting chases/holes in floors / walls / slab. (All Down take RWP & balcony Drain pipe only).110 mm diameter pipe
Providing & fixing Nickel Chromium Plated liquid soap container/dispenser with metallic bottle of approved brand & make 112 mm distance from wall of standard shape with bracket (Nickel chromium plating should pass Salt Spray Test for 200 hours) of the same materials with snap fittings of approved quality and colour, complete as per direction of Engineer in Charge. ( MAKE-1 : JAQUAR, MODEL NO. - ACN-CHR-1137N OR EQUIVALENT.
Providing, Fixing of CP brass Towel Ring with CP brass wall brackets and providing & fixing CP brass screws complete as required. ( MAKE-1: JAQUAR, MODEL NO. TOWEL RING : ACN-CHR-1121N OR EQUIVALENT.)
Providing, Fixing of CP brass Towel Rack 600mm long without hanger with 3 hooks and CP brass screws complete as required. ( MAKE-1: JAQUAR, MODEL NO. TOWEL RACK : ACN-CHR-1181FHN OR EQUIVALENT.)
Providing & fixing soap dish holder of approved design. ( MAKE-1: JAQUAR, MODEL NO. SOAP DISH : ACN-CHR-1131N OR EQUIVALENT.)
Providing and fixing CP brass single lever low flow wall mounted Sink mixer with 15 mm CP brass single lever swivel spout with waste complete with flow rate 2.5 litre per minute at 3 bar including cutting and making good the walls where required. ( MAKE-1: JAQUAR, MODEL NO. SINK MIXER : FLR-CHR-5163GD OR EQUIVALENT.)
Providing and fixing liner floor drain 900mm lanth Make (Kohler 97739T-NA)
Providing , Fixing of CP Brass 450mm long Shower Arm with wall flange and pressure adjustable Overhead Shower with rubit cleaning system with flow rate 6 litre per minute at 3 bar complete with all accessories as required and making good the walls wherever required. ( MAKE-1: JAQUAR, MODEL NO. SHOWER ARM : SHA-CHR-479L450 & OVERHEAD SHOWER : OHS-CHR-1759GA OR EQUIVALENT.)
Providing and fixing automatic sensor faucet for cold and Hot water, for wash basin complete in all respect including basin mounted auto tap, with infrared sensors with solenoid valves for cold water with electronic circuit and necessary accessories including cutting and making good the walls and floors as per requirement. Make: (Kohler 24270IN-ND-CP), (Jaquar SNR-CHR-51021)
Providing and fixing C.P concealed four way diverter with thermostatic mixer with shut off valve and diverter, including cutting and making good the walls, wherever required. (Make:- Jaquar - Four way diverterKUB-35421, Thermostatic mixer 35671 or Equilent)
Providing,Fixing wall mounted Double Coat hook on door complete. ( MAKE-1: JAQUAR, MODEL NO. COAT HOOK : AKP-CHR-35761P OR EQUIVALENT.)
Providing & fixing wall mounted 300mm Long SS Grab Bar including cutting & making good the walls. ( MAKE-1: JAQUAR, MODEL NO. GRAB BAR : AKP-CHR-35701PS OR EQUIVALENT.)
Providing and fixing CP brass 2 Way Bib cock with wall flange with flow restrictor with flow rate 2.5 litre per minute at 3 bar. ( MAKE-1: JAQUAR, MODEL NO. 2 WAY BIB COCK : FLR-CHR-5041NG OR EQUIVALENT.)
Providibng and fixing straight type Macfit single body push fit type WC pan connector with factory supplied spring loaded seal guard of McAlpine, UK with integral single mould sealing fins made of flexible EVA body, including bush/adaptor for use with C.I. Pipe as supplied with the pan connector.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing complete as required. (MAKE-ModiGuard Sparkle Mirror )
Providing & fixing 100mm x 50mm G.I. waste with reducing elbow & nipple cutting chases, the floor / slab, repairs complete as required and connection to GI / CI waste pipe.
Providing and fixing cast brass Floor cleanout plug with suitable insert keys for opening in brass cap, male threaded joint/reducer with G.I. socket caulked to Pipe/fittings of CI pipe including cost of lead joints etc. complete in all respect. 100 mm dia
Providing and fixing GI inlet fitting with maximum 3 inlets 32,40 or 50 mm size fabricated from 100 dia GI pipes and sockets,fixed to C.I. trap with Drip Seal joint and set in cement concrete as per standard drawing complete as directed by Engineer-incharge.
Providing and fixing SS Grating of 125 mm dia of approved quality and colour complete as per direction of engineer in charge. Circular Type 125 mm nominal dia with 25 mm waste hole
Providing, Installing & fixing storage type water heater of approved shade with copper container, glasswool insulation,stove enamelled M.S jacket, thermostatically controlled inner heater with pilot neon lamps, 15mm inlet stop cock valve, on inlet connection, 15mm dia C.P flexible connection pipe in inlet & outlet suitable for working pressure of 8 kg/sqcm complete as required. Capacity 25 litres size 448X448X345mm ( MAKE-1: JAQUAR, MODEL NO. GEYSER : ELENA OR EQUIVALENT.)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work, including cutting chases and making good the walls etc. 15 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work, including cutting chases and making good the walls etc. 25 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work, including cutting chases and making good the walls etc. 32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on Wall. 15 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on Wall. 20 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on Wall. 25 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on Wall. 32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on Wall. 40 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on Wall. 50 mm nominal outer dia Pipes
Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall. 15 mm nominal bore
Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall. 20 mm nominal bore
Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall. 25 mm nominal bore
Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall. 32 mm nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External Work. 25mm nominal nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External Work. 32mm nominal nominal bore
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete. 50 to 80 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S (non modular) bricks of class designation 7.5
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 15mm diameter pipe
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 20mm diameter pipe
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 25mm diameter pipe
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 32mm diameter pipe
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. 25mm diameter pipe
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. 32mm diameter pipe
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 25mm diameter pipe
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. 32mm diameter pipe
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 15 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 20 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 25 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 32 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing C.P. brass Short body bib cock of approved quality conforming to IS:8931 with flow rate 2.5 litre per minute at 3 bar: (MAKE-1: JAQUAR, MODEL NO. SHORT BODY BIB COCK : FLR-CHR-5037NG OR EQUIVALENT.) 15mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms with flow rate 2.5 litre per minute at 3 bar. (MAKE-1: JAQUAR, MODEL NO. LONG BODY BIB COCK : FLR-CHR-5047NG OR EQUIVALENT.) 15mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixture and geyser points of approved quality confirming to IS: 8931. (MAKE-1: JAQUAR, MODEL NO. ANGLE VALVE : AQT-CHR-3057 OR EQUIVALENT.)
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 50 mm dia
Providing and laying S&S C.I. Standard specials such as tees, bends, collars tapers and caps etc, suitable for flanged jointing as per IS : 1538 : Up to 300 mm dia
Providing & fixing CI `Y' Strainer (screwed/ flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flange/ unions nuts, bolts and washers complete as required. 32mm nominal bore
Providing & fixing CI `Y' Strainer (screwed/ flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flange/ unions nuts, bolts and washers complete as required. 40mm nominal bore
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 150 mm diameter S.W. pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 150 mm diameter S.W. pipe / RCC pipe
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 180 x 150mm size P-type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : (For Sewer & Storm Line) 150 mm dia. R.C.C. pipe
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensiions total weight of cover and frame to be not less than 38 Kg. ( weight of cover 23 Kg. and weight of frame 15 Kg.), with FPS bricks with class designation 7.5 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes: Size 90 x 80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality HD - 20 Circular shape 560 mm internal diameter
Excavating trenches of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,depth upto 1.5m including getting out the excavated soil,& then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposing of surplus excavated soil as directed, within lead of 50m. All kinds of soil Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia
Excavating trenches of required width for pipes, cables, etc including excavation for sockets,depth upto 1.5 m, including getting out the excavated matterials, returning the soil as requred in layers not exceeding 20 cm in depth including consolidating each deposited layers by by ramming, watering,etc. and stacking serviceable material for measurements and disposal of unserviceable matterial for measurement and disposal of unserviceable matterial as directed within a lead of 50m: Ordinary rock Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Hard rock (requiring blasting) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Earth Work in excavation by mechanical means (Hydraulic / excavator ) manual means over area (exceeding 30 cm in depth ,1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed as engineer incharge. Ordinary Rock
Earth Work in excavation by mechanical means (Hydraulic / excavator ) manual means over area (exceeding 30 cm in depth ,1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed as engineer incharge. Hard Rock(requiring blasting)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : "1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size).
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. All types of soil 400 mm dia.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer –in-charge. 200 mm nominal size dia.
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia.
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap/shoe or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia
Butterfly valve (manual) with C.I body SS disc nitrile sheet & O ring & PN 16 Pressure rating as specified. 80 mm dia.
Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 16 rating as specified. 80 mm dia.
Providing and fixing 80mm dia GI pipes to IS:1239 heavy class with fittings.
Supply, Lowering, installation & testing of KSB make submersible pumping set with 10 HP motor 18 stage pump suitable for maximum capacity of 20 m3 hr. at 100 mtr. Head respectively. With Three Phase.
Providing & fixing cable 6 sq.mm. From submersible pump to panel board.
Providing & fixing Panel Board for submersible pump fitted with DOL starter ammeter, voltmeter single phase preventer standard/indo/cop make MCB of off switch push bottom duly wired and made out of 16/18 SWG sheet.
HVAC ESTIMATE - IB BUILDING : SUB HEAD-VII AIR CONDITIONING SYSTEM: Supply, Installation, testing and commissioning of air cooled modular type air-conditioning system complete with indoor and outdoor units, individual remote controller , interconnected refrigerant piping ,full charge of refrigerant gas & oil, control cabling etc.as per detail given in specifications and having following items: Refrigerant to be used shall be - R - 410 A. Modular type Air Conditioning units suitable to operate at 415 ± 10 % volt, 50 Hz, 3 phase AC supply and suitable for cooling application compressor by Hermetically sealed scroll/Twin Rotary type with stepless modulation complete with special acryl precoated heat exchanger, low noise condenser fan , auto check function for connection error in display panel, auto address setting as per specifications. The COP at AHRI conditions shall not be less than 3.8 . The units shall be complete with necessary mounting frames and capacity as mentioned below and as per specification. The cost should include the following : Nitrogen pressure testing for refrigerant pipe leakages & flushing during installation & after commissioning between IDU & ODU with flare nuts. Refrigerant gas & oil charging as per OEM standard. Necessary corrosive treatment of copper coil of the ODU with Aluminum hydroxide, 25 microns thickness or equivalent coating as per manufacturer standard to protect from corrosion, sulfur and other chemical contaminants present in the air. The coating should be done in the presence of OEM representative. The coating shall be carried-out by the authorized applicator of coating manufacturer.Note : The ODU provided with cowl duct for exhaust air should have minimum 5 mm ESP. GI wire mesh (minimum 16 SWG thickness) type bird screen with framing at the Mouth of exhaust air Cowl duct of Outdoor Units.ODU Units Mounted on MS Frame/Masonry Pedestal with required anti-vibration mounting. Make- Daikin, Carrier, Toshiba, Hitachi 4.0 TR 1600 CFM) Ductable Split Unit 5.5 TR 2200 CFM) Ductable Split Unit
8.5 TR (3400 CFM) Ductable Split Unit 11.0 TR (4400 CFM) Ductable Split Unit
Supply, Installation, testing & commissioning of Split type 5-star/Inverter cassette air conditioning unit, each comprising of outdoor unit and modular type cassette indoor unit.Outdoor condensing unit shall comprise of single/ multiple , rotary / scroll compressor & air cooled condenser with fan & motor. Evaporating unit shall consist of a blower section with dynamically balanced cenrtifugal blower driven by induction motor, multirowsdeep copper cooling coil with aluminium fins, thermostatic expansion valve, sequential controller etc. The evaporating unit shall be equipped with synthetic fibre filter s, insulated drain pan, safety controls, thermostat, suitable for refrigerant CFC free R 410A all complete in a unit. The enclosure shall be factory painted to a smooth finish. The quoted price shall be inclusive of vibration isolator pads/ vibration isolators and associated electrical cabling & earthing between indoor & outdoor units and MS duly painted base frame. The units shall be suitable for 230 v+ - 10 %, 50 Hz supply & complete with electrical controls & panels. Make- Daikin, Mitsubishi Heavy duty, Toshiba, Carriier 1.5 TR (600 CFM)
Supply, Installation, testing & commissioning of Split type 5-star/Inverter cassette air conditioning unit, each comprising of outdoor unit and modular type cassette indoor unit.Outdoor condensing unit shall comprise of single/ multiple , rotary / scroll compressor & air cooled condenser with fan & motor. Evaporating unit shall consist of a blower section with dynamically balanced cenrtifugal blower driven by induction motor, multirowsdeep copper cooling coil with aluminium fins, thermostatic expansion valve, sequential controller etc. The evaporating unit shall be equipped with synthetic fibre filter s, insulated drain pan, safety controls, thermostat, suitable for refrigerant CFC free R 410A all complete in a unit. The enclosure shall be factory painted to a smooth finish. The quoted price shall be inclusive of vibration isolator pads/ vibration isolators and associated electrical cabling & earthing between indoor & outdoor units and MS duly painted base frame. The units shall be suitable for 230 v+ - 10 %, 50 Hz supply & complete with electrical controls & panels. Make- Daikin, Mitsubishi Heavy duty, Toshiba, Carriier 2.0 TR (800 CFM)
Supply, Installation, testing & commissioning of Split type 5-star/Inverter cassette air conditioning unit, each comprising of outdoor unit and modular type cassette indoor unit.Outdoor condensing unit shall comprise of single/ multiple , rotary / scroll compressor & air cooled condenser with fan & motor. Evaporating unit shall consist of a blower section with dynamically balanced cenrtifugal blower driven by induction motor, multirowsdeep copper cooling coil with aluminium fins, thermostatic expansion valve, sequential controller etc. The evaporating unit shall be equipped with synthetic fibre filter s, insulated drain pan, safety controls, thermostat, suitable for refrigerant CFC free R 410A all complete in a unit. The enclosure shall be factory painted to a smooth finish. The quoted price shall be inclusive of vibration isolator pads/ vibration isolators and associated electrical cabling & earthing between indoor & outdoor units and MS duly painted base frame. The units shall be suitable for 230 v+ - 10 %, 50 Hz supply & complete with electrical controls & panels. Make- Daikin, Mitsubishi Heavy duty, Toshiba, Carriier 2.5 TR (1000 CFM)
Supply, Installation, testing & commissioning of Split type 5-star/Inverter cassette air conditioning unit, each comprising of outdoor unit and modular type cassette indoor unit.Outdoor condensing unit shall comprise of single/ multiple , rotary / scroll compressor & air cooled condenser with fan & motor. Evaporating unit shall consist of a blower section with dynamically balanced cenrtifugal blower driven by induction motor, multirowsdeep copper cooling coil with aluminium fins, thermostatic expansion valve, sequential controller etc. The evaporating unit shall be equipped with synthetic fibre filter s, insulated drain pan, safety controls, thermostat, suitable for refrigerant CFC free R 410A all complete in a unit. The enclosure shall be factory painted to a smooth finish. The quoted price shall be inclusive of vibration isolator pads/ vibration isolators and associated electrical cabling & earthing between indoor & outdoor units and MS duly painted base frame. The units shall be suitable for 230 v+ - 10 %, 50 Hz supply & complete with electrical controls & panels. Make- Daikin, Mitsubishi Heavy duty, Toshiba, Carriier 3.0 TR (1200 CFM)
Supply, Installation, testing & commissioning of Air Cooled Invertor Split type wall mounted 5 Star Air conditioners with evaporating unit comprising of cooling coil, blower with motor and condensing unit comprising hermetically sealed scroll compressor, condenser coil, and propeller fan. Unit shall be complete with controls, interconnecting copper refrigerant piping with insulation, drain pipes and electrical cabling etc. between evaporative and condensing unit, refrigerant gas and oil and complete as per specifications. The unit shall be suitable for operating on 240 volt, 1 phase, 50 Hz AC supply with five star energy rating. The units shall be suitable for chorded remote operation. The refrigerant piping & cabling shall run in PVC sleeve Steel supporting structure for outdoor units suitable for wall mounting / floor mounting. The enclosure shall be factory painted to a smooth finish. The quoted price shall be inclusive of vibration isolator pads/ vibration isolators and associated electrical cabling & earthing between indoor & outdoor units and MS duly painted base frame. The units shall be suitable for 230 v+ - 10 %, 50 Hz supply & complete with electrical controls & panels. Make- Daikin, Mitsubishi Heavy duty, Toshiba, Hitachi, O General, Carrier Capacity : 1.3 TR (450 CFM)
Supply, Installation, testing & commissioning of Air Cooled Invertor Split type wall mounted 5 Star Air conditioners with evaporating unit comprising of cooling coil, blower with motor and condensing unit comprising hermetically sealed scroll compressor, condenser coil, and propeller fan. Unit shall be complete with controls, interconnecting copper refrigerant piping with insulation, drain pipes and electrical cabling etc. between evaporative and condensing unit, refrigerant gas and oil and complete as per specifications. The unit shall be suitable for operating on 240 volt, 1 phase, 50 Hz AC supply with five star energy rating. The units shall be suitable for chorded remote operation. The refrigerant piping & cabling shall run in PVC sleeve Steel supporting structure for outdoor units suitable for wall mounting / floor mounting. The enclosure shall be factory painted to a smooth finish. The quoted price shall be inclusive of vibration isolator pads/ vibration isolators and associated electrical cabling & earthing between indoor & outdoor units and MS duly painted base frame. The units shall be suitable for 230 v+ - 10 %, 50 Hz supply & complete with electrical controls & panels. Make- Daikin, Mitsubishi Heavy duty, Toshiba, Hitachi, O General, Carrier Capacity : 1.5 TR (525 CFM)
Supply, Installation, testing & commissioning of Air Cooled Invertor Split type wall mounted 5 Star Air conditioners with evaporating unit comprising of cooling coil, blower with motor and condensing unit comprising hermetically sealed scroll compressor, condenser coil, and propeller fan. Unit shall be complete with controls, interconnecting copper refrigerant piping with insulation, drain pipes and electrical cabling etc. between evaporative and condensing unit, refrigerant gas and oil and complete as per specifications. The unit shall be suitable for operating on 240 volt, 1 phase, 50 Hz AC supply with five star energy rating. The units shall be suitable for chorded remote operation. The refrigerant piping & cabling shall run in PVC sleeve Steel supporting structure for outdoor units suitable for wall mounting / floor mounting. The enclosure shall be factory painted to a smooth finish. The quoted price shall be inclusive of vibration isolator pads/ vibration isolators and associated electrical cabling & earthing between indoor & outdoor units and MS duly painted base frame. The units shall be suitable for 230 v+ - 10 %, 50 Hz supply & complete with electrical controls & panels. Make- Daikin, Mitsubishi Heavy duty, Toshiba, Hitachi, O General, Carrier Capacity : 2.0 TR (650 CFM)
Supply, Installation, testing & commissioning of Air Cooled Invertor Split type wall mounted 5 Star Air conditioners with evaporating unit comprising of cooling coil, blower with motor and condensing unit comprising hermetically sealed scroll compressor, condenser coil, and propeller fan. Unit shall be complete with controls, interconnecting copper refrigerant piping with insulation, drain pipes and electrical cabling etc. between evaporative and condensing unit, refrigerant gas and oil and complete as per specifications. The unit shall be suitable for operating on 240 volt, 1 phase, 50 Hz AC supply with five star energy rating. The units shall be suitable for chorded remote operation. The refrigerant piping & cabling shall run in PVC sleeve Steel supporting structure for outdoor units suitable for wall mounting / floor mounting. The enclosure shall be factory painted to a smooth finish. The quoted price shall be inclusive of vibration isolator pads/ vibration isolators and associated electrical cabling & earthing between indoor & outdoor units and MS duly painted base frame. The units shall be suitable for 230 v+ - 10 %, 50 Hz supply & complete with electrical controls & panels. Make- Daikin, Mitsubishi Heavy duty, Toshiba, Hitachi, O General, Carrier Sequential Timer (For Server, UPS & ATM Room)
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : Make- Rajco,Mandev tubes, Mehta 6.4 mm Outer dia (OD) Soft Drawn with Tube Thickness-1.2mm (insulation: 19 mm)
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 9.5 mm Outer dia (OD) Soft Drawn with Tube Thickness-1.2mm (insulation: 19 mm)
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 12.7 mm Outer dia (OD) Soft Drawn with Tube Thickness-1.2mm (insulation: 19 mm)
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 15.9 mm Outer dia (OD) Soft Drawn with Tube Thickness-1.2mm (insulation: 19 mm)
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 19.1 mm Outer dia (OD) Hard Drawn with Tube Thickness-1.2mm (insulation: 19 mm)
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 22.2 mm Outer dia (OD) Hard Drawn with Tube Thickness-1.2mm (insulation: 19 mm)
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 25.4 mm Outer dia (OD) Hard Drawn with Tube Thickness-1.2mm (insulation: 19 mm)
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 28.6 mm Outer dia (OD) Hard Drawn with Tube Thickness-1.2mm (insulation: 19 mm)
Supply,installation,testing and commissioning of UPVC drain piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell expanded polythene. Make- Astro, Supreme, Appollo pipe, Astral 25 mm ID
Supply,installation,testing and commissioning of UPVC drain piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell expanded polythene. Make- Astro, Supreme, Appollo pipe, Astral. 32 mm ID
Supply,installation,testing and commissioning of UPVC drain piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell expanded polythene. Make- Astro, Supreme, Appollo pipe, Astral. 40 mm ID
Supplying, installing, testing and commissioning of control cum transmission wiring of 2 core x 1.5 sqmm copper FRLSH, XLPE insulated cable in suitable GI conduits accessories between indoor and outdoor units. Necessary securing of conduit shall be made by contractor. After completion of work wall and floor shall be repaired and brought to its original finish. The rate will also include cost of laying of GI conduit between indoor and outdoor units. 2C x 1.5 Sq mm (Unarmoured)
Supply. Installation, testing and commissioning of factory fabricated GSS Sheet metal ducts with flanges, inbuilt sealant, gasket, supports, vanes, dampers, links, levers and quadrants etc. as per specifications and drawings. Duct shall be furnish at site in "L" shape or box shape from factory. The rates shall include all materials of the duct and labour for suspension and supporting arrangement for plenums, ducts, complete with fire retardant flexible connection as required and as per specifications. Make- Tata, Jindal, Essar, Sail 0.63 MM (24 Gauge )
Supply. Installation, testing and commissioning of factory fabricated GSS Sheet metal ducts with flanges, inbuilt sealant, gasket, supports, vanes, dampers, links, levers and quadrants etc. as per specifications and drawings. Duct shall be furnish at site in "L" shape or box shape from factory. The rates shall include all materials of the duct and labour for suspension and supporting arrangement for plenums, ducts, complete with fire retardant flexible connection as required and as per specifications. Make- Tata, Jindal, Essar, Sail 0.80 MM (22 Gauge )
Supply. Installation, testing and commissioning of insulation on the surface of the duct with duly laminated aluminum foil of mat finish closed cell nitrile rubber (Class 'O' ) with suitable adhesive, as per specifications and drawings. The Joints shall be sealed with 50mm wide and 3 mm thick self adhesive nitrile rubber tape Insulation. The rates shall include all materials of the insulation and labour works with adhesive, complete as required and specifications. Make- Paramount, Supreme, Aeroflex, K-flex, O-Flex 19 mm
Supply. Installation, testing and commissioning of insulation on the surface of the duct with duly laminated aluminum foil of mat finish closed cell nitrile rubber (Class 'O' ) with suitable adhesive, as per specifications and drawings. The Joints shall be sealed with 50mm wide and 3 mm thick self adhesive nitrile rubber tape Insulation. The rates shall include all materials of the insulation and labour works with adhesive, complete as required and specifications. Make- Paramount, Supreme, Aeroflex, K-flex, O-Flex 25 mm
Supply. Installation, testing and commissioning of G.I construction Duct/ Volume control Dampers for Controlling the Airflow in Ducts with neoprene rubber gaskets,nuts, Bolts, Screws Linkages, Flanges etc. as per specification.
Supply. Installation, testing and commissioning of powder coated extruded aluminum sections grills as per specification.
Supply. Installation, testing and commissioning of powder coated extruded aluminum section grills with dampers for supply air terminal for air-conditioning as per specification.
Supply. Installation, testing and commissioning of powder coated extruded aluminum square diffusers with antismudge ring and removable core. Supply air with dampers
Return air without damper
Supply. Installation, testing and commissioning of thermal flexible aluminum duct of following sizes duly supported at regular interval as per site requirement & spefications. 200 mm
Supply. Installation, testing and commissioning of slot diffusers with/without damper as specified below and as per specification. 3-Slot Diffuser
Supply. Installation, testing and commissioning of slot diffusers with/without damper as specified below and as per specification. 2-Slot Diffuser
Supply. Installation, testing and commissioning of powder coated extruded aluminum Linear Grille. 150 mm
Supply. Installation, testing and commissioning of exhaust air/fresh air louvers of powder coated extruded aluminum construction with bird screen, minimum 80 mm deep.
Providing and Fixing Underdeck Insulation with 50 mm thick with closed cell Nitrile Rubber with prelaminated Aluminum foil on one side having a low stable k value of 0.035 k.cal/hr.m at 10.C and minimum density of 40-55 ± 3 kg/cum.The R-value should be as per ECBC Code. 50 mm
REPAIR WORK CIVIL: Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.1 1.00 mm thick with zinc coating not less than 275 gm/m²
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.12.4.1 0.80 mm thick with zinc coating not less than 275 gm/m²
13.91 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing walls with water proofing cement paint of required shade : 13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) 9.1.3 Kiln seasoned and chemically treated hollock wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will Butt hinges and necessary screws shall be paid separately)separately, all complete as per direction of Engineer-in-charge. Butt hinges and necessary screws shall be paid separately) 9.5.1.1 35 mm thick shutters
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 14.5.1 Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)
13.48.2 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
Providing and fixing Polyethelene-Aluminium-Polyethelene PE-AL- PE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes testing of joints complete as per direction of the Engineer-in-charge. i) 20mm
Providing and fixing Polyethelene-Aluminium-Polyethelene PE-AL- PE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes testing of joints complete as per direction of the Engineer-in-charge. ii)32 mm
Providing and fixing Polyethelene-Aluminium-Polyethelene PE-AL- PE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes testing of joints complete as per direction of the Engineer-in-charge. v) 40 mm
Providing and fixing Polyethelene-Aluminium-Polyethelene PE-AL- PE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes testing of joints complete as per direction of the Engineer-in-charge. v) 50 mm
12.56 Providing and laying roof insulation with 40 mm thick impervious sprayed, closed cell free Rigid Polyurethane foam over deck insulation conforming to IS - 12432 Pt. III (density of foam being 40-45 kg/ cum), over a coat of polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene sheet over PUF spray and providing a wearing course of 40 mm thick cement screed 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) in chequered rough finish, in panels of 2.5 m x 2.5 m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, all complete as per direction of Engineer-in-Charge.
Precoated galvanised steel barge board (upto 300mm )
14.33 Providing and fixing bright finished brass flush bolts with necessary brass screws etc. complete b) Tower Bolt iv) 150mm
Providing and fixing bright finished brass flush bolts with necessary brass screws etc. complete g) M.S Butt Hinge i)100mm
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.4.3 Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 11.41.2 Size of Tile 600x600 mm
8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
15.12 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 15.12.2 Of area beyond 3 sq. metres (ii) Area of door/window above 3.00 m2
12.58 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.58.1 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing
ESTIMATE FOR INTERIOR (NON SOR ITEMS) OF IB BUILDING: KING SIZE BED IN IB BUILDING Supply and installation of king size wood bed as per approved drawing & design / specification. Overall Size: Length - 84inch Width - 76inch Height - 43inchMake: Woodsworth, Model: Abbey solid wood king size bed in honey oak finish
KING SIZE MATTRESS IN IB BUILDING: Supply and installation of king size orthopedic or dual comfort mattress as per approved drawing and design specification Mattress (78*72*6inch) / (1.98m*1.83m*15.2cm)Make: Wakefit Model: Wakefit Orthopedic Memory Foam Mattress
PILLOWS IN IB BUILDING: Pillow - supply and installation of Micro Fibre pillows as per approved drawing and design/ specification. Pillow Model: Micro Polyester Pillow White Micro Polyester Fibre Pillows in White Colour by Living Essence 680 mm X 460 mm
KING SIZE BEDSHEET IN IB BUILDING: Supply and installation of cotton or poly cotton king size bedsheet as per approved drawing and design/ specification Make: PizunaModel: Dobby Stripe Collection Cotton 200 TC Double Bedsheetsize 2280mm x 2750mm
PILLOW COVER IN IB BUILDING: Pillow cover - supply and installation of cotton or poly cotton pillow cover as per approved drawing and design/ specification size, AmazonBasics 100% Cotton 400TC Pillow Covers - King, Set of 2,Stone Grey (20 x 40 inches or 51 x102 cm)
HEADBOARD IN IB BUILDING: Head Board - supply and installation of customized engineered wood and fabric headboard for king size bed as per approved drawing and design/ specification size 4125mm x 1200mm
KING SIZE COMFORTER IN IB BUILDING: Supply and installation of king size micro fibre comforter as per approved drawing and design/ specification. Make: Zeba Model: Multicolor 100% Cotton 150 GSM AC Room Double Bed Quilt and 2 Pillow ShamFabric Material: 100% CottonLength:108 x Width:90 Inches, Sham : 17x27InchesWeight: 3 KgColour: MulticolourGSM: 150
SIDE TABLE IN IB BUILDING: Supply and placement of Bedside table as per approved drawing and design/ specification Make: Orange tree Model: Dali Bedside Table in Natural Finish, H 19.7 x W 22.8 x D 15.7 (All Dimensions are in inches)
SIDE TABLE IN IB BUILDING: Supply and placement of Bedside table as per approved drawing and design/ specification Make: Orange Tree Model: Toshi bedside table in natural finish Height: 18.9inch Width: 18.9inch Depth: 13.8inch
STUDY TABLE IN IB BUILDINGSupply and installation of wooden study table as approved drawing and design/ specification Size: H30 x W24 x D55 Make: Bohemiana Model: Warlick solid wood desk table in rustic teak finish
STUDY CHAIR IN IB BUILDING: Supply and installation of Study Chair as per approved drawing and design/ specification.Make: Pace seating Model: Pacer dining chair in brown finish Height: 31in Width: 22in Depth: 18in
CREDENZA/TV UNIT IN IB BUILDING: Supply and installation of wood TV unit of overall size Height- 18in Depth- 16in Width-59in as per approved drawing and design/ specification. Make: Orange Tree Model: Throne tv console in natural finish
3 DOOR WARDROBE IN IB BUILDING: Supply and installation of customized engineered wood 3 door wardrobe with PU finish as per approved drawing and design/ specification
4 DOOR WARDROBE IN IB BUILDING: Supply and installation of customized engineered wood 4 door wardrobe with PU finish as per approved drawing and design/ specification
ARTWORK IN IB BUILDING: Supply and installation of artwork as per approved drawing and design/ specification 1372 mm X 762 mm Make: 999storeModel: Multicolour MDF Printed Colorful Abstract Multi Frame Painting
ARMCHAIR IN IB BUILDING: Supply and installation of wooden chair with cushioned seat as per approved drawing and design/ specification. H33.5 x W36.8 x D34.4 Make: Godrej Interio Model: Flight 1 seater sofa in dark grey colour
3 SEATER SOFA IN IB BUILDING: Supply and installation of sectional sofa with cushioned seat as per approved drawing and design/ specification. 33H x 84W x 36D Make: Jordyblue Model:Rekford 3 seater sofa in beige colour
BALCONY CHAIR IN IB BUILDING: Supply and installation of balcony armchair 27in x 21in x 33in as per approved drawing and design/ specificationMake: BohemianaModel: Elio Jute Cafe Chair (Set Of 2) In White & Natural Finish H 28 x W 27.3 x D 22.3 (All Dimensions in Inches)
SIDE TABLE IN IB BUILDING BALCONY: Supply and installation of side table H18 x W15 x D15 as per approved drawing and design/ specifications.Make:The Urban storeModel: Solid wood end table in walnut and white finish
TOILET MIRROR IN IB BUILDING: Supply and installation of decorative toilet mirror as per approved drawing and design/ specificationMake: Elegant Art and FramesModel: Wooden Square Wall Mirror in Brown colour
TOWEL HOLDER IN IB BUILDING: Supply and installation of powder coated metal towal holder 600 mm long as per approved drawing and design/ specificationMake: JaquarModel: Continental
DECORATIVE POT IN IB BUILDING: Supply and installation of decorative pot as per approved drawing and design/specification.Make: Yuccabe ItaliaModel: White Polymer Square PlanterDimensions: Length: 13, Width: 13, Height: 30 InchesWeight: 2 Kgs
DECORATIVE LIGHT IN IB BUILDING: Supply and installation of decorative pendant light as per approved drawing and design/ specificationMake: LogamModel:Effie gold iron Pendant LightDimensions:16 Inches(L) x 16Inches (B) x 10 Inches(H)
WALLPAPER IN IB BUILDING: Supply and installation of customized wallpaper cladding 140sqm as per approved drawing and design / specification
STAND LAMP IN IB BUILDING: Supply and installation of decorative Standing lamp as per approved design and drawing/specification. Make: Bohemiana Model: Cesky Beige Fabric Shade Tripod Floor Lamp with Brown Base
WASHROOM VANITY IN IB BUILDING: Supply and installation of customized engineered wood washroom vanity with PU finish and stone top as per approved drawing and design / specification
3 SEATER SOFA IN IB BUILDING: Supply and installation of 3 seater fabric sofa H 32 x W 78 x D 32; Seating Height-17(all dimensions in inches)Weight26 KG Warranty 12 Months' WarrantyAssembly Carpenter Assembly Primary Material Fabric Seating Height 17 ColourGreyModel: Mid-century classic 3 seater sofa in grey colourMake: Dreamzz Furniture
ARMCHAIR IN IB BUILDING: Supply and installation of wooden Armchair sofa with fabric cushioned seat as per approved drawing and design/ specification Make: Dreamzz FurnitureModel: Carolina lounge chair in grey colourProduct Dimensions:35x35x34inch
CENTER TABLE IN IB BUILDING: Supply and installation of wood Center Table of 22D x 42W x 16H as per approved drawing and design/ specification. Make: BohemianaModel: Torino solid wood coffee table in rustic teak finish
SIDE TABLE IN IB BUILDING: Supply and installation of engineered wood Center Table of 18.3D x 18.3W x 16H as per approved drawing and design/ specification. Make: Orange TreeModel: Throne end table (set of 2) in natural finish
SOFA CUSHION IN IB BUILDING: Supply and installation of micro fibre sofa cushion as per approved drawing and design/ specification Make: My gift boothModel: White Polypropylene Microfiber Filled 20X20 Inches Cushion Insert
SOFA CUSHION COVER IN IB BUILDING: Supply and installation of cotton or poly cotton cushion cover as per approved drawing and design/ specification Red 100% Cotton Geometric 20x20 Inches Cushion Cover BrandPluchi
6 SEATER DINING TABLE IN IB BUILDING: Supply and installation of wood 6 seater dining table.Table : H 30 x W 59 x D 35; Chair : H 35 x W 18 x D 18.7; Bench : H 18 x W 48 x D 18(all dimensions in inches) as per approved drawing and design/ specificationMake: WoodsworthModel:Stigen Solid Wood 6 Seater Dining Set with Bench in Provincial Teak Finish
KING SIZE BED IN IB BUILDING SINGLE ROOMS: Supply and installation of king size wood bed as per approved drawing & design / specification. Overall Size:H 43 x W 75 x D 82 (All Dimension Are In Inches)Make: Durian, Model: Olivia King Size Bed In Dark Oak Finish
RECEPTION DESK IN IB BUILDING: Supply and installation of customized engineered wood reception desk with PU Finish as per approved drawing and design / specification
EXECUTIVE CHAIR IN IB BUILDING: Supply and installation of Ergonomic chair for lumbar support with 360° swivel base, metal frame, cushioned seat, seat height adjustment and tilt mechanism as per approved drawing and design/ specificationMake: Star IndiaModel: All steel sleek design high back ergonomic chair in black colourDimensions: H 42 x W 23 x D 24; Seating Height: 18 (All Dimensions in Inches)Weight: 14 KG
FILE CABINET IN IB BUILDING: Supply and installation of customized engineered wood 2 door file cabinet with PU finish as per approved drawing and design/ specification
OFFICE DESK IN IB BUILDING: Supply and installation of customized engineered wood office executive desk with PU Finish as per approved drawing and design / specification
CONFERENCE TABLE IN IB BUILDING: Supply and installation of customized engineered wood and metal 3m long table with PU Finish as per approved drawing and design / specification
CONFERENCE CHAIR IN IB BUILDING: Supply and installation of metal / wooden chair with cushioned seat in Conference as per approved drawing and design/ specification Make: Trevi furnitureModel: Comet chair black and grey finishDimensions: H 38 x W 20 x D 19; Seating Height-25(all dimensions in inches)Weight: 12 KG
6 SEATER DINING TABLE IN IB BUILDING: Supply and installation of wood 6 seater dining table 29.5in x 70.8in x 39.3in as per approved drawing and design/ specificationMake: CasacraftModel: Arabia - Haruka 6 Seater Dining Table Set
4 SEATER OUTDOOR DINING TABLE IN IB BUILDING: Supply and installation of 4 seater Table : H 30 x W 28.7 x D 28.7; Chair : H 31 x W 16.2 x D 20.2; Seating Height - 17(all dimensions in inches) as per approved drawing and design/ specificationMake: BohemianaModel: Mexico patio set
BALCONY ARMCHAIR IN IB BUILDING:Supply and installation of balcony armchair H 39.4 x W 43.3 x D 37.4; Seating Height 19.7 (All dimensions in inches) as per approved drawing and design/ specificationMake: @homeModel: Plush patio chair in brown colour
Providing and fitting modular kitchen in IB building: Supply and installation of modular KBottle Pullout Unit 300 mm (Normal close) Valentia Red 1 2 Thali Unit 600 mm Valentia Red 1 3 Plain Shelf Unit 900 mm Valentia Red 1 4 Plain Shelf Unit 600 mm Valentia Red 1 5 Grocery Unit 600 mm Valentia Red 1 6 Utensil Unit 600 mm Valentia Red 1 7 Utensil Unit 900 mm Valentia Red 1 8 Top Plain Shelf Unit 800 mm Shell White 1 9 Top Plain Shelf Unit 600 mm Shell White 1 10 Top Plain Shelf Unit 1000 mm Shell White 1 11 Top Plain Shelf Unit 500 mm Shell White 1 12 Utensil Unit 800 mm Valentia Red 1 13 Hinged Unit below Sink 600 mm Valentia Red 1 14 Hinged Unit below Sink 1000 mm Valentia Red 1 15 Plain Shelf Unit 500 mm Valentia Red 1 16 Top Plain Shelf Unit 800 mm Shell White 1 17 Top Plain Shelf Unit 800 mm Shell White 1 18 Top Plain Shelf Unit 900 mm Shell White 1 19 90mm Filler Valentia Red 1 20 Plain Shelf Unit 600 mm Valentia Red 1 21 Top Plain Shelf Unit 600 mm Shell White 1 22 Top Plain Shelf Unit 800 mm Shell White 1 23 Top Plain Shelf Unit 900 mm Shell White 1 24 Multi Utility Unit 450 mm Valentia Red 1 25 Plain Shelf Unit 800 mm Valentia Red 1 26 Top Plain Shelf Unit 600 mm Shell White 1 27 30mm Filler Valentia Red 1 28 Plain Shelf Unit 500 mm Valentia Red 1 29 Cooking Unit 900 mm Valentia Red 1 30 Bottle Pullout Unit 300 mm (Normal close) Valentia Red 1 31 Corner Plain Shelf Unit 1000 mm Valentia Red 1 32 Plain Shelf Unit 600 mm Valentia Red 1 33 Plain Shelf Unit 800 mm Valentia Red 1 34 SKIRTING (REHAU) SYSTEM-100mm BRUSHED ALUMINIUM 11 35 BRUSHED ALUM. SKIRTING 100mm HARDWARE PACKET FOR KITCHEN CABINETS 1 36 Legs 100 mm 56 37 HANDLE RECTA 128 mm PITCH 60 38 Hardware packet for Kitchen 5
TOILET MIRROR IN QUARTERS: Supply and installation of decorative toilet mirror as per approved drawing and design/ specification MaterialMetal Dimensions Length: 2 inches, Width: 32 inches, Height: 32 inches Weight 4 Kg Colour GoldMake: CraftterModel: Abstract wall mirror in golden colour
Survey & Soil Test
Tribeni Constructions Limited
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.11 MB
SBD_SOPD_G_21_22_Bokakhat_IB.pdf
Tender Documents • 3.88 MB
FOB.pdf
Additional Documents • 0.15 MB
BOQ_42139.xls
BOQ • 0.73 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .