Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.3 LAdmitted-Finance 19 LAKE TEMPLE ROAD KOLKATA 700029 | KOLKATA | WEST BENGAL | 700029 | ₹36.3 L | L1 | Admitted-Finance |
| 2 | L2₹39.8 LAdmitted-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹39.8 L | L2 | Admitted-Finance |
| 3 | L3₹40.0 LAdmitted-Finance 4TH FLOOR VOLTAS HOUSE A BLOCK DR BABASAHEB AMBEDKAR ROAD CHINCHPOKLI MUMBAI MAHARASHTRA 400033 | MUMBAI | MAHARASHTRA | 400033 | ₹40.0 L | L3 | Admitted-Finance |
| 4 | L4₹64.3 LAdmitted-Finance | ₹64.3 L | L4 | Admitted-Finance |
| 5 | Rejected-Technical PLOT NO 53 B INDUSTRIAL AREA NO 1 A B ROAD DEWAS MADHYA PRADESH 455001 UDYAM MP 16 0001781 23AAECM4586A1ZR R M MII STATUS AS VERIFIED | DEWAS | MADHYA PRADESH | 455001 | - | - | Rejected-Technical nonsubmission of requisite documents. |
| Sl No | Description | Qty | Unit | BLUE STAR LIMITED L2 | VOLTAS LIMITED L3 | TRANSTECH L4 | Shinryo Suvidha Engineers India Pvt. Ltd. L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | FRP INDUCED DRAFT COOLING TOWER
SITC of FRP Induced draft Counter Flow Cooling Tower suitable for 2000 USGPM water Air-conditioning Plant having following heat rejection capacity with FRP
water basin, PVC fillings with integral louvers, ladder and drift eliminators complete with hot water basin either
filled with spray nozzles or having self rotating sprinklers, statically and dynamically balanced axial flow type fan- direct driven or driven through reduction gear box with three phase, 415 ± 10%
volts, 50 Hz. TEFC induction motor, suction screen, make up-quick fill arrangement, overflow and drain connections with necessary valves.
i) Cooling Towe Inlet Temp: 36.0 Deg C
ii) Cooling Tower Outlet Temp: 32.0 Deg C
iii) water circulating capacity: 2000 USGPM
Make: PAHARPUR/BELL/ADAVANCE | 3 | Nos | 11,61,527 ₹34,84,581 | 11,58,327 ₹34,74,981 | 19,27,589 ₹57,82,767 | 10,67,246 ₹32,01,738 |
| 2.00Supply and laying of MS 'C' Class Chilled water pipe | |||||||
| 2.10 | 250 mm dia pipe | 30 | Mtrs | 5,145 ₹1,54,350 | 5,365 ₹1,60,950 | 5,517 ₹1,65,510 | 4,800 ₹1,44,000 |
| 2.20 | 100 mm dia pipe | 30 | Mtrs | 1,864 ₹55,920 | 1,864 ₹55,920 | 1,916 ₹57,480 | 1,686 ₹50,580 |
| 3.00Supply, installation, testing and commissioning of following sizes of Valves & Temperature Gauge | |||||||
| 3.10 | Butterfly Valve (250mm Dia) | 6 | Nos | 25,742 ₹1,54,452 | 21,671 ₹1,30,026 | 22,280 ₹1,33,680 | 18,681 ₹1,12,086 |
| 3.20 | Butterfly Valve (100mm Dia) | 12 | Nos | 6,714 ₹80,568 | 5,745 ₹68,940 | 5,906 ₹70,872 | 4,940 ₹59,280 |
| 4.00 | Dismantling work of Existing Cooling Tower and shifting within the premises. | 3 | Nos | 18,308 ₹54,924 | 35,243 ₹1,05,729 | 72,466 ₹2,17,398 | 21,402 ₹64,206 |
| 5.00Note: 1.The existing cooling tower sump area dimension is (14900mmx 5850mm). Prospective bidders may kindly visit the site prior to design given on the above data and quote. 2) All the above rates should be quoted inclusive of all taxes & duties, District charges and LWC as applicable. 3) The Agency must procure the materials from the manufacture/OEM or their authorised sales Channel so that the standard warranty/support of the manufacturerer/OEM becomes applicable to the product to be delivered and installed by them. Documents that authenticate such procurement from the manufacturer/OEM or from their authorised sales Channel and standard warranty/support should be sent from the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work/submission of bill. If any refubrished materials are supplied and installed, penal action will be taken as per existing rule. Before execution of the work the prospective bider has to submit layout drawing as per design of OEM dully approved by the OEM. 4) Total is rounded off to the nearest rupees. | |||||||
Tender Value
Refer Docs
EMD Value
₹99,750
Closing Date
16 Jan 2026, 12:00 pmClosed
The Executive Engineer, Kolkata Electrical Div
The Executive Engineer Kolkata Electrical Division P.W.Dte. Block I (1st Floor) Writers Buildings, Kolkata 700001
SITC of induced draft cooling Towers 3nos for replacement old and partially damaged existing system at Netaji Indoor Stadium.
2025_WBPWD_979436_1
WBPWD/EE-KED/eNIQ-50Q/25-26
Open Tender
ELECTRICAL WORKS ORG
30 days
Netaji indoor Stadium
Please refer Tender documents.
5 documents required · 5 mandatory
₹99,750
O/O The Executive Engineer Kolkata Electrical Divi
9 Feb 2026
24 Dec 2025
19 Jan 2026
24 Dec 2025
16 Jan 2026
6 Jan 2026
5 Jan 2026
FRP INDUCED DRAFT COOLING TOWER SITC of FRP Induced draft Counter Flow Cooling Tower suitable for 2000 USGPM water Air-conditioning Plant having following heat rejection capacity with FRP water basin, PVC fillings with integral louvers, ladder and drift eliminators complete with hot water basin either filled with spray nozzles or having self rotating sprinklers, statically and dynamically balanced axial flow type fan- direct driven or driven through reduction gear box with three phase, 415 ± 10% volts, 50 Hz. TEFC induction motor, suction screen, make up-quick fill arrangement, overflow and drain connections with necessary valves. i) Cooling Towe Inlet Temp: 36.0 Deg C ii) Cooling Tower Outlet Temp: 32.0 Deg C iii) water circulating capacity: 2000 USGPM Make: PAHARPUR/BELL/ADAVANCE
Supply and laying of MS 'C' Class Chilled water pipe
250 mm dia pipe
100 mm dia pipe
Supply, installation, testing and commissioning of following sizes of Valves & Temperature Gauge
Butterfly Valve (250mm Dia)
Butterfly Valve (100mm Dia)
Dismantling work of Existing Cooling Tower and shifting within the premises.
Note: 1.The existing cooling tower sump area dimension is (14900mmx 5850mm). Prospective bidders may kindly visit the site prior to design given on the above data and quote. 2) All the above rates should be quoted inclusive of all taxes & duties, District charges and LWC as applicable. 3) The Agency must procure the materials from the manufacture/OEM or their authorised sales Channel so that the standard warranty/support of the manufacturerer/OEM becomes applicable to the product to be delivered and installed by them. Documents that authenticate such procurement from the manufacturer/OEM or from their authorised sales Channel and standard warranty/support should be sent from the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work/submission of bill. If any refubrished materials are supplied and installed, penal action will be taken as per existing rule. Before execution of the work the prospective bider has to submit layout drawing as per design of OEM dully approved by the OEM. 4) Total is rounded off to the nearest rupees.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.33 MB
2911.pdf
Tender Documents • 0.54 MB
BOQ_2387326.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid