| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1171.6 CrAccepted-AOC | ₹1171.6 Cr Quoted ₹117.6 Cr | L1 | Accepted-AOC l1 |
| 2 | L2₹120.9 CrRejected-Finance | ₹120.9 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹132.3 CrRejected-Finance PLOT NO 137 2ND FLOOR AVTAR ENCLAVE PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | ₹132.3 Cr | L3 | Rejected-Finance L3 |
| 4 | L4₹150.3 CrRejected-Finance | ₹150.3 Cr | L4 | Rejected-Finance L4 |
Tender Value
Refer Docs
EMD Value
₹2.1 Cr
Closing Date
2 Jun 2021, 5:00 pmClosed
Executive Engineer VII
Executive Engineer VII
Construction of MCG Office Building, Sector 14 Vyapar Sadan, Municipal Corporation, Gurugram
2021_HRY_171565_1
EE/VII/2021/05/00015
Open Tender
Civil Works - Buildings
720 days
Construction of MCG Office Building, Sector 14 Vya
Please refer Tender documents.
4 documents required · 4 mandatory
₹50,000
Yes
₹2.1 Cr
Yes
4 Oct 2021
12 May 2021
3 Jun 2021
12 May 2021
2 Jun 2021
12 May 2021
Amount
N.S. Item
Extra for royalty of earth (including the cost of mining fees
Providing and stacking on Site including transportaion loading, unloading and placing one time on site Granite Stone of all shades as approved by Engineer in charge, 15 to 18mm thick.
Extra for vaccum dewatering process in flooring in pavements for dewatering, floating & troweling with the help of power trowelling floater of concrete floor as directed & specified using necessary steel form work with M.S. Channels Rate includes forming construction & Construction joints 4 mm to 6 mm wide by cutting the floor upto 20 %(1/5th) depth of thickness of the concrete depth using mechanical saw up to full depth of cutting . The rate includes providing and filling the joints with epoxy compound as specidied by engineer in charge
Providing and Fixing Wooden floor of 8mm thick with uniclic technology, of panel sizes 190x1200mm, with usage class method EN 13329 with value 21-22-23/31-32, and minimum waranty of 5 years from installation, wear resistance ≥ 4000 cycles, wear class AC4, Impact resistance - IC2, Scratch resistance- ≥ 5N, Thickness swelling- ≤ 12%, Locking strength (ISO 24334)- Fl0,2 long side ≥ 1 kN/m,Fs0,2 short side ≥ 2 kN/m, Surface soundness- ≥ 1.50, Resistance to staining EN 438- Class 5, General appearance EN 13329 Height differences- ≤ 0,10 mm Opening between joints - ≤ 0,10 mm Cupping in the length- concave ≤ 0,50%, Cupping in the width- concave ≤ 0,15%, Dimensional variations after changes in relative humidity- ≤ 0,9 mm, Light fastness EN ISO 105 B02- Class 8, Impact sound reduction- ΔLw ≈ 18 dB, GRIHA complaint INSTALLATION complete with underlay layers of 3mm As per satisfaction of Engineer- in-charge.
Providing & Fixing Vitrified Tiles 1000 x 1000 mm or 800x 1200 or 800 x 1600 of approved make in flooring laid in any pattern as specified over base of 20 mm thick cement coarse sand morter 1:3 and joint will be 4 mm wide instead of zero joint by using spacers to ensure uniformity of joint duly filled with epoxy grout minimum depth upto the thickness of tile of reputed make such as pidilite (T-13 Roff), Mapaie, Laticrete, Ardex Endura as approved by Engineer-in-charge. Note:- Tile shall be of premium quality (first quality) of reputed manufacturer like: RAK, NITCO, KAJARIA, JOHNSONS, (Double charged tiles/ PGVT of approved make as per GRIHA certified tiles shall be used as approved by Engineer in charge. (NS).
Providing & Fixing Vitrified Tiles 800 x 1200 mm or 800 x 1600 mm of approved make skirting/dados, pillars, wall facing, laid in any pattern as specified over base of 20 mm thick cement coarse sand morter 1:3 and joint will be 4 mm wide instead of zero joint by using spacers to ensure uniformity of joint duly filled with epoxy grout minimum depth upto the thickness of tile of reputed make such as pidilite(T-13 Roff), Mapaie, Laticrete, Ardex Endura as approved by Engineer-in-charge. Note:- Tile shall be of premium quality (first quality) of reputed manufacturer like: RAK, NITCO, KAJARIA, SOMANI, JOHNSONS, ORIENTBELL, SIMPOLO. (Double charged / PGVT tiles shall be used as approved by Engineer in charge. (NS).
Providing and laying 80mm Thk ISI marked interlocking grass paver blocks confirming to IS 15658:2006/ IRC SP63-2004 of all shapes and colours in design mix cement M-40 over a bed of 30cm thick fine sand complete in all respects.
Providing and fixing chicken mesh/MURGA JALI at jointing including fixing JALI with Nails prior to plaster on walls with hardware
Providing and fixing toilets cubicle modules of partitions made up of 12 mm th Phenolic resin HPL panel as per drawing as per size 1950 mm x 1000mm x 1500 mm in middle units and 1950 mm x 1500 x 1500 as end units with doors and hardware in Stainless steel , complete in all respects
Providing and fixing 1200 mm high and 600 mm wide PVC /Metal letters with lighting,power supply etc as per details and design with suitable hardware to anchor the same on subsurface (NS)
Design supply fabrication installation position tubular space frame structure for entrance to with stand a wind pressure as per IS codes using members and node connectors providing and fabricating space frame member (SPME/SPPM) of different types of membe (N.S)
Supplying and fixing 12 mm thick multiwall polycarbonate sheet roof cladding at all levels as per pattern for skylight roof cladding and specials with necessary aluminium extrausions with EPDM gasket, cutting fabricating erection at all levels with painting (N.S)
Supplying and fixing, installing and commissioning Automatic Boom Barriers for efficient security at exit and entry points with electrical control panels and sensors for auto access controls thru push button and manual operation in case of power failure ; Boom length 6.0 m , torque 600 Nm of make Godrej or equivalent , complete in all respects
Extra for using Ecosense Enhance Marine blue 6mm th SH 38/37 tempered glass of make AIS or equivalent as per approval of architect
Providing & Fixing Shafts for services, ventilation consisting of MS frame of 40x40x6mm MS angel finished with 19mm prefinished fiber board etc. as per desigen complete. (N.S)
Providing & fixing Glass fiber reinforced concrete (GRC) lattice screen of thikness for 40mm or as per manufactuarer blocks complete fixed at site. (N.S)
Providing and Fixing Channeled Woodworks perforated panels of width 128mm, thickness of 18mm and length 2440 mm or as required by the Architect/ acoustic consultant, made of a high density particle board substrate with a laminated facing as per the approved shade/ species & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern 13/3 (12.8% perforation rate) . The panels shall provide a minimum sag resistance of RH90 and a fire rating 0.85 NRC. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. Installation of Woodwork perforated panels on GI Channels of section 50mm x 50mm on 40 X 40 X 5mm GI angle Supports Fixed to solid wall having 50 mm air gap. GI panels fixed horizontally at spacing of 600mm center to centre and screwed aluminum extruded keel for channeled wood works with 50mm thick thermal banded polyester non-woven wadding Mikron fiber of 1000 gm/sqm. The mikron fiber to be held in position with chicken wire mesh. The final color of the material and design horizontal orvertical to be approved by the consultant and the architect both to ensure the final looks of the installation is as per the design intended for, contractor to take a final sign off before start of work . The panels shall be mounted on special aluminum splines using clips. All Makes and models of all items/samples should be approved by the consultant prior to the installation.
Providing and fixing in position PVC flexible waste pipe of 32mm dia for wash basin complete in all respect (as approved by Engineer-in-Charge). - COD 17.28.2.1
Providing and fixing High Temparature Polyproplene (HT-Pro).Polypropylene (PP), produced according to EN 1451-1and ISO 7671:2003 respectively, resistant to hot water upto 95 degree Celcius (Continuous) and 98 degree Celcius (Short periods) with pH between 2 & 12, permanent low inflammability as per EN 4102-2 with fire classification B2. Smoke Development Category Q1, Drip Formation Category TR1. push-fit type, Halogen and Calcium free, having Notch impact resistance (at -10°c / kJ/m²) as per DIN 53453, Ring stiffness SN4 4.0KN/m2 as per ISO 9969, 14366 at a flow water tightness as per EN 1451-1 minimum of 0.5 bar for 15 minutes, density of pipe = 0.90-1.05 gms/cm3, elongation = 0.09mm/m0K and E modulus 2300-3000 as per ISO 178, along with factory fitted EPDM lip ring. (Make - HULIOT/WAVIN/REHAU ) for 160 MM
For 110 mm Pipe
For 75 mm Pipe
Providing and fixing High Temparature Polyproplene (HT-Pro).Polypropylene (PP), produced according to EN 1451-1and ISO 7671:2003 respectively, resistant to hot water upto 95 degree Celcius (Continuous) and 98 degree Celcius (Short periods) with pH between 2 & 12, permanent low inflammability as per EN 4102-2 with fire classification B2. Smoke Development Category Q1, Drip Formation Category TR1. push-fit type, Halogen and Calcium free, having Notch impact resistance (at -10°c / kJ/m²) as per DIN 53453, Ring stiffness SN4 4.0KN/m2 as per ISO 9969, 14366 at a flow water tightness as per EN 1451-1 minimum of 0.5 bar for 15 minutes, density of pipe = 0.90-1.05 gms/cm3, elongation = 0.09mm/m0K and E modulus 2300-3000 as per ISO 178, along with factory fitted EPDM lip ring. (Make - HULIOT/WAVIN/REHAU ) for 50 MM
For 40 mmPipe
Providing and fixing PP 110mm P Trap with minimum 50mm water seal with rubber seal on inlet to push fit hopper for indirect waste connections (Make - HULIOT/WAVIN/REHAU ) 110 mm inlet and 110 mm outlet
Providing and fixing floor drain (Nahani Trap) with 75mm outlet and 100 mm inlet .(Make - HULIOT/WAVIN/REHAU ) With 63 mm i/d outlet. ( 110 x 75 x 40)
Providing, fixing, testing and commissioning of pipe inlet fittings fabricated with Polyproplene Pipe with maximum 3 inlets 40, 50 & 75 mm OD size Polyproplene pipe, fixed to 'P' traps including Dripseal/Pipe seal/solvent /rubber ring joint complete .(Make - HULIOT/WAVIN/REHAU )
Providing and fixing end cap (door piece) of pp for cleaning. (Make - HULIOT/WAVIN/REHAU )
Providing and fixing Vent cowl for all vertical soil and waste stack including jointing with pipes complete. (Make - HULIOT/WAVIN/REHAU ) with 110 DN
Providing and fixing of C.P brass central hole sink mixture complete in all respects of approved make as approved by the Engineer-in-Charge.
Providing and fixing CPVC pipes having theMetreal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge.. - Exposed on wall , COD - 18.7 15 mm internal diameter COD 18.7.1
20 mm internal diameter COD 18.7.2
25 mm internal diameter COD 18.7.3
32 mm internal diameter COD 18.7.4
40 mm internal diameter COD 18.7.5
50 mm internal diameter COD 18.7.6
Providing and fixing CPVC pipes having theMetreal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the wall same including testing of joints complete as per the direction of engineer inchargel : COD 18.8 15 mm internal diameter COD 18.8.1
20 mm internal diameter COD 18.8.2
Painting GI pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality COD DSR 18.40 25 mm dia, nominal bore COD 18.40.3
32 mm dia, nominal bore
40 mm dia, nominal bore
50 mm dia, nominal bore
65 mm dia, nominal bore
80mm nominal bore
100mm nominal bore
Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc. (internal work) 25 mm dia, nominal bore COD 18.10.3
32 mm dia, nominal bore COD 18.10.4
40 mm dia, nominal bore COD 18.10.5
50 mm dia, nominal bore COD 18.10.6
65 mm dia, nominal bore COD 18.12.7
80mm nominal bore COD 18.12.8
100mm nominal bore ELECT. DSR 2018 / 14.13.3
150mm nominal bore ELECT. DSR 2018 / 14.13.4
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) (of approved make and ISI marked): 25 mm nominal bore COD 18.17.1
32 mm nominal bore COD 18.17.2
50 mm nominal bore COD 18.17.4
65 mm nominal bore COD 18.17.4
80 mm nominal bore COD 18.17.4
Providing and fixing brass ball valve with SS 304 Stem and ball, teflon seat complete (PN-16). 20 mm internal diameter of pipeline
25 mm internal diameter of pipeline
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of pproved shape including providing & fixing white vitreous low noise Concealed cistern with delayed filling valve without frame with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc omplete. DSR 17.78
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in- charge. DSR 17.16A
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge..(sink & urinal) DSR 17.22A
Providing and fixing white color vitreous China flat back, under counter wash basin with R.S. or CI bracket and 32 mm dia outlet, with 32 mm dia C.P. bottle trap with brass C.P. wall cap and extension pieces, 15 mm dia C.P. brass angle stop cock with 10mm dia C.P. brass connection pipe etc. CP brass chain, CP wall flange, rubber adopter for waste connection complete, CP brass chain CP waste and CP pipe to wall with CP wall flange and rubber adopter for waste connection complete, with pedestal of matching model below wash basin, including cutting and making good the walls wherever required. Make: Hindware, Model: Magna, Cat no. 10095
Supply, installation, testing and commissioning vitreous china flat back large urinal with concealed wall hangers, fully automatic photoelectric cell operated No-touch urinal flushing system (Battery/electrical operated vandal proof- twin flush (pre & post use) operation), flush mounted sensors complete in all respects in fully operational conditions, C.P. brass flush pipe with C.P. clamps and screws, C.P. flange with spreader, 32 mm C.P. cast brass bottle trap and pipe to wall with wall flange complete including cutting and making good the walls and floors where required. [Make Euronics-Kinox-KUF) or Equivalent
Providing and fixing uplasticised PVC connection pipe with brass unions DSR 18.21.2.1 45 cm length 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality confoMetreing to IS 8931 a) 15 mm nominal bore. DSR 18.53.1 15 mm nominal bore
Providing and fixing CP Brass shower rose with 15 or 20 mm inlet DSR 18.22.2 15 mm nominal bore
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge . DSR 17.22B 15 mm nominal bore
Providing and Fixing of wash basin mixer with cartridge with hot water limiter ; manual closing action should Comprises: mounting accessories for single-hole installation and with technical data. [Make - Hindware, Model Cat No F730001] 15 mm nominal bore
Providing and fixingF.R.P. MH Cover with frame 600 mm dia dimensions for basement sump and over head tank (Make - PROLONG/THERMODRAIN/V2V )
Providing and fixing F.R.P. Grating. With "L" angal 636 x 1006 x 30 mm ( Load Bearing capable 5.0 T, suitable for Basement drain Area ) (Make - PROLONG/THERMODRAIN/V2V ) - Drain Cover
BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified. ELECT. DSR 2018 16.11.1 65 nominal bore
80 nominal bore
100 nominal bore
150 nominal bore
NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified. ELECT. DSR 2018 16.11.2 150 nominal bore
100 nominal bore
80 nominal bore
Providing & Fixing G.I. Pipes complete with G.I.Fittings including trenching and refilling etc. (external work) (External Irrigation Water Supply works). 25 mm dia nominal bore
50 mm dia nominal bore
65 mm dia nominal bore
80 mm dia nominal bore
Providing and filling sand of grading zone V or coarse grade alround the CPVC/GI pipes in external work. 25 mm nominal outer dia.
50 mm dia nominal bore
65 mm dia nominal bore
80 mm dia nominal bore
Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) 25mm dia, nominal bore
50 mm dia nominal bore
65 mm dia nominal bore
80 mm dia nominal bore
Constructing masonry chamber 30x30x50 cm,inside with 75 class designation brick work in cement mortar 1:4 (1 cement:4 coarce sand) for stop cock complete with C.I. surface box 100x100x75mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size) necessary excavation foundation concret 1:5:10 (1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortor 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design.
Providing & fixing of Garden hydrant outlet consisting 1 No. 20mm dia. Ball valve, Bib cock (Brass) for connecting rubber hose, pipes & fittings including brick masonary chamber 300x300x500mm. Bib Cock - 20mm
Ball Valve - 20mm
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer –in-charge.
Boring/drilling bore well of required dia for asing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from ifferent strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. All types of soil 300 mm dia.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer –in-charge. 150 mm nominal size dia.
Supplying, filling, spreading & leveling gravels of size range 4.6 mm to 4.8 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality L D- 2.5 Rectangular shape 600x450mm internal dimensions
Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete.
Providing and fixing High Temparature Polyproplene (HT-Pro).Polypropylene (PP), produced according to EN 1451-1and ISO 7671:2003 respectively, resistant to hot water upto 95 degree Celcius (Continuous) and 98 degree Celcius (Short periods) with pH between 2 & 12, permanent low inflammability as per EN 4102-2 with fire classification B2. Smoke Development Category Q1, Drip Formation Category TR1. push-fit type, Halogen and Calcium free, having Notch impact resistance (at -10°c / kJ/m²) as per DIN 53453, Ring stiffness SN4 4.0KN/m2 as per ISO 9969, 14366 at a flow water tightness as per EN 1451-1 minimum of 0.5 bar for 15 minutes, density of pipe = 0.90-1.05 gms/cm3, elongation = 0.09mm/m0K and E modulus 2300-3000 as per ISO 178, along with factory fitted EPDM lip ring. (Make - HULIOT/WAVIN/REHAU ) 160 mm OD UPVC Pipe
Providing, fixing, commissioing and testing package vertical raw water pumps, comprising of Electrical Driven inline pumping with all accessories, Pumps shall be with C.I. Base, S.S 304, impeller, shaft, mechanical seal, S.S. Shaft directly coupled to motor suitable for operation on 400/440 volts, 3 phase 2900 RPM. TEFC electronic motor mounted on a common channel baseplate 150mm dia pressure gauge, GM isolation cock and cement concrete foundation with plaster with dunlop cushy foot mountings with all accessories such as NRVs, valves, pressure guage bourden type, common suction and delivery header, bellows on sucton and delivery side complete in all repsects. Raw Water Treatment Feed Pump set
Pumps shall be suitable for 415 ± 10% volts 3 phase 50 Hz A.C supply & shall be having the following requirement complete with foundation and associated civil works. Suction & Delivery Header - SS 304 Control Valve On suction and Delivery - Ball Valve Only (No Butterfly Valve Accepted). Flow Prevention - Only Check Valve Suction & delivery header including all pipes, suction & delivery sides valves, NRV, Pressure gauges & accessories complete. Flow Rate : 3.5 LPS (1 working + 1 stand by) Head : 35 M Min. Motor HP : 3.5 H.P. (Each) Treated Water Pump set
Providing, fixing, commissioing and testing package vertical treated water transfer pumps, comprising of Electrical Driven inline pumping with all accessories, Pumps shall be with C.I. Base, S.S 304, impeller, shaft, mechanical seal, S.S. Shaft directly coupled to motor suitable for operation on 400/440 volts, 3 phase 2900 RPM. TEFC electronic motor mounted on a common channel baseplate 150mm dia pressure gauge, GM isolation cock and cement concrete foundation with plaster with dunlop cushy foot mountings with all accessories such as NRVs, valves, pressure guage bourden type, common suction and delivery header, bellows on sucton and delivery side complete in all repsects. Pumps shall be suitable for 415 ± 10% volts 3 phase 50 Hz A.C supply & shall be having the following requirement complete with foundation and associated civil works. Suction & Delivery Header - SS 304 Control Valve On suction and Delivery - Ball Valve Only (No Butterfly Valve Accepted). Flow Prevention - Only Check Valve Suction & delivery header including all pipes, suction & delivery sides valves, NRV, Pressure gauges & accessories complete. Flow Rate : 3.5 LPS (1 working + 1 stand by) Head : 70.0 M Min. Motor HP : 6.5 H.P. (Each) Water Booster Pumpset (Treated Water Supply) - Roof Level
Supplying & supervision of testing & commissioning of Booster Pumpset (Hydropneumatic systems) as described below Supplying & supervision of testing & commissioning of package vertical Hydropneumatic system, comprising of 2.0 nos. (1 duty + 1 stand by) Electrical Driven inline pumping sets each of 2.0 LPS to a head to 25 meter with all accessories, Pumps shall be with C.I. Base, S.S 304, impeller, shaft, mechanical seal, S.S. Shaft directly coupled to motor suitable for operation on 400/440 volts, 3 phase 2900 RPM. TEFC electronic motor mounted on a common channel baseplate 150mm dia pressure gauge, GM isolation cock and cement concrete foundation with plaster with dunlop cushy foot mountings with all accessories such as NRVs, valves, pressure switch, common suction and delivery header, bellows on sucton and delivery side complete in all repsects. Pump mounted or wall mounted microprocessor based controller, Electronic control panel with frequency inverter, logic controller relays, pressure sensor, pressure sensor transmitter, electrical wiring, cabling from panel to pumps, level controller, two lined LCD display, diodes to indicate pump ready, pump running and fault capable to communicate with toher RS 485 interface. with Power box equipped with fuses or isolators or circuit breakers as required. complete with all accessories as per manufacturer specifications. Suction & Delivery Header - SS 304 Control Valve On suction and Delivery - Ball Valve Only (No Butterfly Valve Accepted). Flow Prevention - Only Check Valve One Number Variable frequency Drive Impeller : Stainless Steel Shaft : Stainless Steel RPM : 2900. Mover : Electric Motor HP - As required. Necessary foundation with bolts Ball valve on suction & delivery NRV on delivery Dust & veMetrein proof cubicle type motor control centre fabricated from powder coated 16 SWG MS sheet suitable to automatic working of above mentioned pumps.
Sump Pumps : Supply & Installation, testing and commissioning of centrifugal non clogging submersible sump pumps for plant room drainage. Pump capable capable of handling 25 mm dia soft solids. Motor suitable for 415 + 10% volts, 3 phase, 50 Hz AC Power supply. Pumps shall be suitable for automatic/manual operation (Overall depth of sump – 1.5 M). Submersible sump pump shall be provided with dry running protection. Inclusive of supporting arrangement for stationary type. Two nos. of pump installed in one sump pit 1 working & 1 standby with automatic/manual opration as requireds. Waste Water Drainage Sump Pump Flow rate : 4.0 LPS Head : 10 Mtrs.
Supply & Installation, testing and commissioning of centrifugal non clogging submersible sump pumps for plant room drainage. Pump capable capable of handling 25 mm dia soft solids. Motor suitable for 415 + 10% volts, 3 phase, 50 Hz AC Power supply. Pumps shall be suitable for automatic/manual operation (Overall depth of sump – 1.5 M). Submersible sump pump shall be provided with dry running protection. Inclusive of supporting arrangement for stationary type. Min. Motor HP : 1.5 (Each)
WATER TREATMENT PLANT : Supply & installation, testing & commissioning of sand filter having FRP pressure vessel suitable for test pressure of 7 Kg. / cm2 including valves for back-wash arrangement complete with initial charge of media to remove the total suspended particles from the water. Capacity : 3.5 LPS Working Pressure : (5 ± 2.5)MWC
Supplying, storing, handling, installation, testing & commissioning of Activated Carbon Filter having FRP pressure vessel suitable for test pressure of 7 Kg./cm2 including valves for back-wash arrangement complete with initial charge of media to remove the total suspended particles from the water. Capacity : 3.5 LPS Working Pressure : (5 ± 2.5)MWC
Supplying, storing, handling, installation, testing & commissioning of water softening system having FRP pressure vessel suitable for test pressure of 7 Kg/cm2 including dished end, ion- exchange resin, Frontal piping, C.I. diaphragm type valve, brine injection assembly for regeneration of softener, brine measuring cum salt water tank, inter connected flexible polypropylene MS Rubber lined (MSRL) piping, valves including provision of bye-pass arrangement complete with inside and outside painting etc. as required. Receiving, storing, handling and fixing of PVC/HDPE/FRP tank for Brine solution along with Hydraulic Injector with control valve and piping for brine injection. Capacity : 3.5 LPS Working Pressure : (5 ± 2.5)MWC
Supplying and fixing of PVC/HDPE/FRP tank including electrical operated metering/dosing pump for dosing of alum/sodium hypo-chlorite solutions in pipeline (all contacting parts shall be of stainless steel). Capacity - 0-12 LPH
Supplying & fixing of float based visual flow meter (Rotameter) suitable for water flow rate of 18000 litres per hour in the input line of water softener including matching flanges, nuts, bolts and 3 mm thick rubber insertions/gaskets complete. to assess the water flow rate in water softener.
CUBICAL PANEL BOARD - PLUMBING PH Detailed as per DNIT mentioned
POWER & CONTROL CABLING : Supplying and Earthing with GI earth plate 600mm x 600 mm x 6mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc, with coke and salt ) as required.
Supplying and laying 25 mm x 5 mm. G.I. strip in 40 mm dia. G.I. Pipe from earth electrode, as required.
Providing & fixing 25mm x 5mm G.I. strip on surface or in recess for connections etc. as required.
Providing and Fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing alongwith existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying, fabricating and installing following size of perforated M.S. cable trays, including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenders and including paint 100 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Laying and fixing of One number PVC Insulated and PVC Sheathed/XLPE power cable of 1.1 kV grade of size not exceeding 25 sqmm on surface as required.
Laying and fixing of One number PVC Insulated and PVC Sheathed/XLPE power cable of 1.1 kV grade of size exceeding 25 sqmm but not exceeding 120 sqmm on surface as required.
Supplying of all materials and making terminations of 1.1 KV grade aluminium multicore cables of the following sizes. The work includes cable glanding using brass plated double compression glands, sizing the core leads, removing insulation, fixing suitable crimping type copper lugs/ thimbles by using hydraulic crimping tools with correct size of the dies, shaping the leads and neatly connecting the same to the equipment terminals. 3.5 Core 120 sq. mm. Armoured Aluminium cable.
3.5 Core 35 sq. mm. Armoured Aluminium cable.
Control Cabling ( PVC insulated and PVC sheathed, armoured, Copper Conductor of 1.1 KV grade on existing cable trays). 5C x 1.5 Sq. mm
SBR Based Plant Semi-Automatic System Details are mentioned as per DNIT
2 Nos.Stainless Steel Suitable Sized Manually operated Bar Screen made of SS in RCC screen channel as per following specifications mentioned in DNIT
Supply, installation, testing & commissioning of Submersible pumps with suitable solid handling capacity with CI casing & CI impeller complete with all accessories, motor of required capacity. The pumps shall be complete with Delivery header with, pressure gauge on delivery line with isolation level controller (with wiring) to control the level of Sump automatically. Pumps shall have following duty mentioned as pe DNIT
Piping and Accessories ; Providing and fixing all interconnecting exposed plant piping of required MOC as MS/GI/PVC/CPVC/UPVC and isolation control valves for making the piping arrangement complete within the battery limits.
Aeration System- Biological Treatment : Supply, installation, testing & commissioning of SBR Package, automatic system with Diffused aeration system comprises of Air Blowers (1W+1S) of required capacity, Silicon air diffusers and air grid in UPVC. Decanter shall be installed in reactor tank for decanted water extraction. Inlet of sewage water decantation and aeration shall be automatic and PLC controlled with the help of automatic valves or by equipment arrangement. All tanks shall be controlled by two stage level controller for high and low level feedback details are mentioned in DNIT
Supply, installation, testing & commissioning of SBR Package, automatic system with Diffused aeration system comprises of Air Blowers (1W+1S) of required capacity, Silicon air diffusers and air grid in UPVC. Decanter shall be installed in reactor tank for decanted water extraction. Inlet of sewage water decantation and aeration shall be automatic and PLC controlled with the help of automatic valves or by equipment arrangement. All tanks shall be controlled by two stage level controller for high and low level feedback.
Tertiary Treatment : Supplying, installing, testing, commissioning of Centrifugal Horizontal Filter feed pumps along with pressure gauge with isolation cock, Isolation valve, NRV on delivery line. Isolation valve, strainer at suction. The pump shall be suitable for 415±10% volts 3 phase AC supply details are mentioned in DNIT
Supplying, Installation, testing and commissioning of Chlorine dosing system comprising of Sintex Tank with inlet/ outlet connection, piping and valves alongwith metering pump for dosing as per DNIT
Supplying, installation, testing & commissioning of MSEP/FRP vessel filter with frontal piping and Valves with all the required accessories. Filter shall include media, standard fittings like pressure gauges, sampling cock, rinse drain as per DNIT
Activated Carbon Filter as per DNIT
Sludge Dewatering System : Supply, installation, testing & commissioning of Sludge transfer pumps for transfering sludge to sludge holding tank complete with all the accessories, motor of required capacity. The pumps shall be complete with Base frame, Delivery header with pressure gauge on delivery line AS PER dnit
Supply, installation, testing & commissioning of Sludge Feed pumps for feeding sludge to sludge Bag System complete with all the accessories, motor of required capacity. The pumps shall be complete with Base frame, Delivery header with pressure gauge on delivery line as per DNIT
Supplying, installing, testing, commissioning of Filter Press of Suitable size with all required accessories to complete the system
Providing & fixing on line full bore type Magnetic flow meter with preamplifier & microprocessor based electronic flow meter mounted in plumbing plant room electrical control panel with the following features. Monitoring the total flow, Flow rate, etc. Including electrical wiring from preamplifier to microprocessor based flow meter. Complete with all type of Plumbing & Electrical connections, accessories, wiring, conduits & supports complete with all respect. The signal from read out shall be 4-20 m.amps to be received as BAS.
a) Suitable for flow rate of sewage feed pump to SBR tank for 130 KLD STP
Flushing Water Supply Pumps : Providing, fixing, commissioing and testing package vertical Irrigation water pumps, comprising of Electrical Driven inline pumping with all accessories, Pumps shall be with C.I. Base, S.S 304, impeller, shaft, mechanical seal, S.S. Shaft directly coupled to motor suitable for operation on 400/440 volts, 3 phase 2900 RPM. TEFC electronic motor mounted on a common channel baseplate 150mm dia pressure gauge, GM isolation cock and cement concrete foundation with plaster with dunlop cushy foot mountings with all accessories such as NRVs, valves, pressure guage bourden type, common suction and delivery header, bellows on sucton and delivery side complete in all repsects.
Irrigation water Transfer Pump set : Providing, fixing, commissioing and testing package vertical Irrigation water pumps, comprising of Electrical Driven inline pumping with all accessories, Pumps shall be with C.I. Base, S.S 304, impeller, shaft, mechanical seal, S.S. Shaft directly coupled to motor suitable for operation on 400/440 volts, 3 phase 2900 RPM. TEFC electronic motor mounted on a common channel baseplate 150mm dia pressure gauge, GM isolation cock and cement concrete foundation with plaster with dunlop cushy foot mountings with all accessories such as NRVs, valves, pressure guage bourden type, common suction and delivery header, bellows on sucton and delivery side complete in all repsects.
WASTE TO ENERGY CONVERTOR: Supplying, installing, testing and commissioning of Bio Urja, waste to biogas convertor, as per vendor's own design and drawing as per detailed specifications and scope of work given. 100 KG Capacity
SUB HEAD - I : POINT WIRING : Supplying and drawing following pair 0.5 mmdia FRLPVC insulated annealed copper conductor,unarmored telephone cable in the existing surface / recessed steel / PVC conduit as required 1 Pair
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface / recessed steel / PVC conduit as required.
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Telephone socket outlet
TV antenna socket outlet
RJ-45LAN socket with shutter
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and Fixing following sizes / modules , GI box along with modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (75 mm X 75 mm) For Data, Telephone and TV
3 Module (100 mm X 75 mm) For Data, Telephone and TV
4 Module (125 mm X 75 mm) For Data, Telephone and TV
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 20/25A modular socket outlet and 20/25A modular SP MCB,"C" cruve including connection etc. as required
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Supplying and drawing of UTP 4 Pair Cat 6 LAN Cable in the existing surface / recessed Steel / PVC conduit as required.
1 run of cable
2 run of cable
3 run of cable
Providing and laying 1.6 MM thick G.I. factory fabricated raceways of the following sizes including providing removable 3mm thick G.I. Cover knock out holes and fixing accessories with arrangement for earthing at ends complete as required including floor supports, bends, junction box etc complete as required.
50 mm wide x 25 mm deep raceway
100 mm wide x 40 mm deep raceway
200 mm wide x 40 mm deep raceway
300 mm wide x 40 mm deep raceway
Supplying, Installation, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10A, for mounting height up to 2.8 meter and for 5 meter diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.
Supplying, Installation, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor with day light dimming (lighting levelshall be regulated as per availability of natural day light in an area along with occupancy detection.) having high preformance, regulating programmable type, suitable for connected load upto 10A, for mounting height up to 2.8 meter and for 5 meter diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.
Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars/Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.
1 output per phase and suitable for single phase supply
2 output per phase and suitable for single phase supply
2 output (1output per phase) and suitable for three phase supply
SUB HEAD - II : INTERNAL LIGHT
Supply, Installation, testing and commissioning of surface & recessed mounting type Led light fixture, LED of 1 to 3 W each assembled on single MCPCB, having color temperature 5700 to 6500K & having 50000 burning hrs life with minimum @ L70, system lumen output should be minimum with efficacy> 80lm/W. LED driver, PF 0.95 & THD <20%. The colour rendering index of LED light should be more than 70. Housing made of CRCA with glare free diffused polycarbonate cover. Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved Lab. Manufacturer manadatory i/c connection wire, testing etc. to complete the job. 2 Yrs Guarantee certificate from manufacturer.
SITC of Recess mounted 6W LED downlighter will give nominal system lumen output of 660lm and a system efficacy of 110lm/W. The luminare should have beam angle of 120Deg with a color temperature of 5700K and CRI>80, with L 70 , 50000hrs. The luminaire shall meet IP20 rating with THD < 10% , High PF >0.95,IK 05 and housing made of casted AL with PS diffuser for better light distribution and the diffuser helps to stabilise UV and prevent from yellowing and the luminaire has the features of Input Voltage : AC220-240V, 50/60Hz, Voltage operating range : 100-300V having High, Operating temperature : 0 Deg to 45 Deg,.Driver shall be non itegral isolated.
Supply of Recess mounted 9W LED downlighter will give nominal system lumen output of 990lm and a system efficacy of 110lm/W. The luminare should have beam angle of 120Deg with a color temperature of 5700K and CRI>80, with L 70 , 50000hrs. The luminaire shall meet IP20 rating with THD < 10% , High PF >0.95,IK 05 and housing made of casted AL with PS diffuser for better light distribution and the diffuser helps to stabilise UV and prevent from yellowing and the luminaire has the features of Input Voltage : AC220- 240V, 50/60Hz, Voltage operating range : 100-300V having High, Operating temperature : 0 Deg to 45 Deg,.Driver shall be non itegral isolated.
SITC of Recess mounted 12W LED downlighter will give nominal system lumen output of 1320lm and a system efficacy of 110lm/W. The luminare should have beam angle of 120Deg with a color temperature of 5700K and CRI>80, with L 70 , 50000hrs. The luminaire shall meet IP20 rating with THD < 10% , High PF >0.95,IK 05 and housing made of casted AL with PS diffuser for better light distribution and the diffuser helps to stabilise UV and prevent from yellowing and the luminaire has the features of Input Voltage : AC220- 240V, 50/60Hz, Voltage operating range : 100-300V having High, Operating temperature : 0 Deg to 45 Deg,.Driver shall be non itegral isolated.
SITC of surface mounted 15W LED downlighter will give nominal system lumen output of 1140lm and a system efficacy of 75lm/W. The luminare should have beam angle of 120Deg with a color temperature of 6000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% , High PF >0.9,IK 05 and housing made of die cast Al with PS diffuser for better light distribution and the diffuser helps to stabilise UV and prevent from yellowing and the luminaire has the features of Input Voltage : AC220-240V, 50/60Hz, Voltage operating range : 100-275V having High, Operating temperature : 0 Deg to 45 Deg,.Driver shall be integral isolated.
SITC of Recess mounted 15W LED downlighter will give nominal system lumen output of 1650lm and a system efficacy of 110lm/W. The luminare should have beam angle of 120Deg with a color temperature of 5700K and CRI>80, with L 70 , 50000hrs. The luminaire shall meet IP20 rating with THD < 10% , High PF >0.95,IK 05 and housing made of casted AL with PS diffuser for better light distribution and the diffuser helps to stabilise UV and prevent from yellowing and the luminaire has the features of Input Voltage : AC220- 240V, 50/60Hz, Voltage operating range : 100-300V having High, Operating temperature : 0 Deg to 45 Deg,.Driver shall be non itegral isolated.
SITC of Recess mounted 20W LED downlighter will give nominal system lumen output of 2200lm and a system efficacy of 110lm/W. The luminare should have beam angle of 120Deg with a color temperature of 5700K and CRI>80, with L 70 , 50000hrs. The luminaire shall meet IP20 rating with THD < 10% , High PF >0.95,IK 05 and housing made of casted AL with PS diffuser for better light distribution and the diffuser helps to stabilise UV and prevent from yellowing and the luminaire has the features of Input Voltage : AC220- 240V, 50/60Hz, Voltage operating range : 100-300V having High, Operating temperature : 0 Deg to 45 Deg,.Driver shall be non itegral isolated.
SITC of 20W LED Batten will give nominal system lumen output of 2400lm and a minimum system efficacy of 120lm/W. The luminare should have beam angle of 120 Deg with a color temperature of 5700K ,CRI>80. The luminaire shall meet IP20 having CRCA housing powder coated and high efficient polycarbonate diffuser for better light distribution. The luminaire has the features of Input Voltage : 240V, 50/60Hz,p.f>0.95,THD<10% , with High Surge Protection : 4KV, Operating temperature : -10Deg to 45Deg ,IK05,Driver shall be integral and isolated.
SITC of 40W LED Batten will give nominal system lumen output of 4600lm and a minimum system efficacy of 115lm/W. The luminare should have beam angle of 120 Deg with a color temperature of 5700K ,CRI>80. The luminaire shall meet IP20 having CRCA housing powder coated and high efficient polycarbonate diffuser for better light distribution. The luminaire has the features of Input Voltage : 240V, 50/60Hz,p.f>0.95,THD<10% , with High Surge Protection : 4KV, Operating temperature : -10Deg to 45Deg ,IK05,Driver shall be integral and isolated.
SITC of 35W LED suspended linear will give nominal system lumen output of 3500lm and a minimum system efficacy of 100lm/W. The luminare should have beam angle of 120 Deg with a color temperature of 6000K ,CRI>80. The luminaire shall meet IP20 having extruded Al housing including die-cast Al end cap. BWF diffuser with push fit technology.The luminaire have integrated energy efficent isolated driver The luminaire has the features of Input Voltage : AC220-240V, 50/60Hz, Voltage operating range : 100-300V with High Surge Protection : 4KV, Operating temperature : 0Deg to 45Deg
SITC of recess mounted square 2X2 36W LED luminarie will give nominal system lumen output of 3600 lm and a system efficacy of 100lm/W.The luminaire shall have a rated system life of 50,000BH @ L70. The luminare should have beam angle of 120 Deg with a color temperature of 5700K and CRI>80. The luminaire shall meet IP20 rating with High PF >0.95 and THD<10% . The luminaire housing should made of CRCA powder coated finish, high efficienct anti glare PMMA diffuser for better light distribution. The luminaire have separate energy efficent isolated driver and the luminaire has the features of Input Voltage : AC220-240V, 50/60Hz, Voltage operating range : 100-300V with surge protection 2.5KV ; Operating Temperature : 0 Deg to 45 Deg
Supply of recess mounted square 2X2 20W LED luminarie will give nominal system lumen output of 2500 lm and a system efficacy of 125lm/W.The luminaire shall have a rated system life of 50,000BH @ L70. The luminare should have beam angle of 120 Deg with a color temperature of 5700K and CRI>80. The luminaire shall meet IP20 rating with High PF >0.95 and THD<10% . The luminaire housing should made of CRCA powder coated finish, high efficienct anti glare PMMA diffuser for better light distribution. The luminaire have separate energy efficent isolated driver and the luminaire has the features of Input Voltage : AC220-240V, 50/60Hz, Voltage operating range : 100-300V with surge protection 2.5KV ; Operating Temperature : 0 Deg to 45 Deg
12W bracket light
SITC of 10W LED Bulkhead will give nominal system lumen output of 850lm and a minimum system efficacy of 85lm/W. The luminare should have beam angle of 120 Deg with a color temperature of 6500K ,CRI>80. The luminaire shall meet IP65 with polycarbonate housing and high efficient polycarbonate diffuser for better light distribution. The luminaire has the features of Input Voltage : 240V, 50/60Hz,p.f>0.9,THD<10% , Operating Voltage 140-275with High Surge Protection : 4KV, Operating temperature : -10Deg to 45Deg ,IK05,Driver shall be integral and isolated.
SITC of 10W LED ultraslim polycarbonate decorative LED batten with inbuilt heat sink,anti glare polycarbonate diffuser with energy efficient electronic driver.The luminare should have beam angle of 120 Deg with a color temperature of 6500K . The luminaire has the features of Input Voltage :220- 240V,CRI >80 50/60Hz,p.f>0.9, Operating Voltage 90-305 .
Psupply and fixing of Ceiling Fan 1200 mm Dia. , BEE three star rated as per ECBC 2017 Compliance of approved make and designed by Engineer in charge.
SITC of 2 x 20 watt wall / surface mounted emergency light fixture (Auditorium)
Supply of Recess mounted 40 W COB LED downlighter will give nominal system lumen output of 4200lm and a system efficacy of 105lm/W. The luminare should have beam angle of 60Deg with a color temperature of 6500K and CRI>80, with L 70 , 50000hrs. The luminaire shall meet IP20 rating with THD < 10% , High PF >0.9, and housing made of Die casted AL with PC diffuser for better light distribution and the diffuser helps to stabilise UV and prevent from yellowing and the luminaire has the features of Input Voltage : AC220-240V, 50/60Hz, Voltage operating range : 90-305V having High, Operating temperature : -10 Deg to 45 Deg,
1 x 150 watt maintenance light fixture (Auditorium)
Fire Exit Signage with specs as per NBC 2016
SUB HEAD - III : DISTRIBUTION BOARD : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way (4+18 ),double door
10 way (4+30 ),double door
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing Cable End Box (Loose wire box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415V, on surface / recess, complete with testing and commissioning etc. as required.
6 way Double door TPN MCB DB
8 way Double door TPN MCB DB
10 way Double door TPN MCB DB
12 way Double door TPN MCB DB
Supplying and fixing Cable End Box (Loose wire box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240V, on surface / recess, complete with testing and commissioning etc. as required.
8 way Double door SPN MCB DB
12 way Double door SPN MCB DB
SUB HEAD - IV : RISING MAIN : Supplying, installing on wall, testing and commissioning of following capacity Air Insulated Compact Type Rising Mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply with enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos. aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints & expansion joints, fire barrier at each floor, provision of tapping at every meter, continuous earthing with 2 Nos. aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.
500 A 35KA SC for 1 sec
800 A 50KA SC for 1 sec
Supplying, installation, testing & commisioning of following capacity End Feed Unit for the existing Air Insulated CompactType bus trunking/ rising mains for use on 3 phase 4 wire 415V, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with provision of MCCB/ ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required
500 A 35KA SC for 1 sec
800 A 50KA SC for 1 sec
Supplying, installation, testing & commisioning of following capacity Plug In/ tap off box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB (but without MCCB) complete etc. as required
100A, 25kA, TP MCCB
125A, 25kA, TP MCCB
Providing and fixing following rating and breaking capcity and pole MCCB with thermomagnetic & microprocessor based release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc as required. (for VTPN DB/MDB & Tap of box)
100A, 25kA, 4P MCCB
125A, 25kA, 4P MCCB
500 A 35KA 4P MCCB for End Feed Unit
800 A 50KA 4P ACB for End Feed Unit
SUB HEAD - V Addressable Fire Alarm: Supply, Installation, Testing & Commissioning ofof Micro processor based 3 no of 4 loop panel with optional redunadant network module ,each loop shall have the capability of connecting 255 detectors & devices.The fire alarm control panel shall have built in degarde mode function.The panel should have inbuilt TCP/IP communication for Panel Program and Remote monitoring option through LAN or WAN communication.The panel shall be able to give location of all fire and more Fire /fault and Isolation conditions of addressable units via the address codes.The panel shall have the capacity of storing upto 3000 events.Further, the panel must be able to automatically switch ON /OFF respective control module when ever any alarm is triggered. The panel shall have a 320 x 240 dots monochrome LCD display with resolution and analog output.The Panel Should have protection category of IP30. Also the panel should have the option to operate in manned and unmanned mode. The panel shall have a built in power supply and battery charger along with maintenance free 28AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required.and as per specifications Panel shall be capable of
12 Loop Panel
Graphical User Interface
Supply, Installation, Testing & Commissioning of of Active Repeater Panel to be integrated with Fire Alarm Control Panel,larger LCD or LED display with resistive touch screen or function keys and automatic back-light dimming and the status of any Fire/Fault of Integrated Fire Alarm Panels, Panel should compliant with EN54.
Supply, Installation, Testing & Commissioning of Intelligent Analog Addressable Photoelectric Type Smoke Detector for Above and below ceiling and integral response indicator with 360 degree viewing angle. Detector shall communicate 4 danger levels for differentiated alarm activation and high tolerance to dust,dirt, temperature fluctuations and air currents. Detector should have unquie address for communication and assigned through panel with Mounting Base as required with the protection category of IP40. Detector shall comply with EN 54/ Vds, CE certified .
Supply, Installation, Testing & Commissioning of Intelligent Analog Supply of Intelligent Analog Addressable Heat Detector (Static + ROR) and integral indicator with 360 degree viewing angle. Detector shall communicate 4 danger levels for differentiated alarm activation. Detector should have unquie address for communication and assigned through panel with mounting base as required with the protection category of IP51 and duly approved by EN 54/Vds/CE certified .
Supply, Installation, Testing & Commissioning of Response Indicator with matching screws complete with GI Junction box, Cable lugs at cable end and ferruling.
Supply, Installation, Testing & Commissioning of addressable short-circuit isolator Base for all types of detectors , fast connector terminals for easy installation of any cable type One External Indicator (LED) can be connected to the base, Cable entry from top or side. Duly approved with to EN54- 17/VdS/ CE certified.
Supply, Installation, Testing & Commissioning of Addressable Relay Module with Address Switch and all mounting accessories complete as required.Shall be complete with Pilot Relay for Tripping of Third Party Equipment, suitable for switching 5A/15A current through the Relay contacts , MS Powder coated Junction Box and mouting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
Supply, Installation, Testing & Commissioning of Addressable Manual Call Station(Break Glass Type) with Adddress Switch and all mounting accessories , complete with MS Powder coated Junction Box for and mouting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling. UL Listed
Supply, Installation, Testing & Commissioning of Addressable Control /Relay Module with Address Switch and all mounting accessories, complete with MS Powder coated Junction Box and mouting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
Supply, Installation, Testing & Commissioning of Ceiling / Wall Mounted Muli-Candela Strobe cum Hooter with all required accessories for mounting complete as required.
Supply, Installation, Testing & Commissioning of Optical Beam Smoke Detector with Allows for 2 Detectors per System Controller. Range 5 to 100 metres, Allows for 2 Detectors per System Controller.Each Detector configurable from 8m to 100m. Separate Fire and Fault relays per Detector. Integral LASER alignment. Auto-Align Fast Automatic Beam Alignment. Building Movement and Contamination Compensation Low Level System Controller Tested and approved according to EN54 & VdS approval.
SITC of addressable Monitor Module with built in isolator for monitoring inputs for flow switch or gas release in electrical panels or server rooms as applicable and as per specifications. Complete as required. Module shall comply with EN 54/ Vds, CE certified
SITC of addressable Multipurpose I/O with built in isolator for control AHU,Fire Damper, Starter panel, Fire Curtains etc. Complete as required. Module shall comply with EN 54/ Vds, CE certified
Supply, Installation, Testing & Commissioning of Power Supply Unit - 240VAC to 24VDC - 6Amps. Power Supply shall be UL Listed with Necessary Battery Backup suitable for total Strobe cum hooter connection complete with all accessories as required.
Supply and Laying of following sizes of PVC sheathed Copper conductor armoured cable of 1.1 KV grade on surface including saddle, clamps, termination etc. complete as required.
2C X 1.5 Sq mm 2core 1.5 Sqmm Fire survival Armoured Cable
2C X 2.5 Sq mm FRLS Ar. Copper Cable
Supply and laying of 25mm ISI Marked PVC Conduit.
SUB HEAD - VI PA System: Supply, Installation, testing and commissioning of 8 Zone Digital Voice Evacuation Controller with built in 500W Class-D amplifier and compliant with the standards of BS EN54-32 & EN60849. The System should be capable to EVAC, paging, PA and BGM and it shall have SD card memory for the recording of EVAC and Alert message. The System should Support Class AB Speaker line with Speaker line supervision. 100V Line speaker output with seperate zone volume control. Seperate indicators for status, Priority level, Two combo inputs for mic/line, 8 line inputs and one rec output., the system shall have fireman microphone and Should be able to Integrate with fire alarm System. and zone capacity up to 120 Zones by cascaded 14 unit’s routers.
Supply, Installation, testing and commissioning of 8 Zone Digital Voice Evacuation Router with the Capacity of 500W Class - D Amplifier. Suitable to Connect 8 Nos of Loudspeaker lines. Compliant to EN54 and Should be able to Integrate with fire alarm System..
Supply, Installation, testing and commissioning of 500W RMS four Channel Class-D Digital Power Amplifier with Switch power technology for power electricity saving. Amplifier shall have Following Features: 120W RMS per Channel, Amplifier Output 100V, Short Circuit, Power, Tempreature, Overload Protection, Auto Cooling Fans. THD <0.1%, Frequency Response 20Hz - 20kHz, AC & DC Fuse, SNR >80dB.
6W Recessed Ceiling / Wall mounted speakers with following features:- Speaker Drive 4", Complete Aluminium grille and Metal baffle, line matching transformer 100/70V line. Variable wattage tappings of 6 / 3 / 1.5, Effective frequency range 90-18kHz (BS6840), SPL@1m/1W=90dB, 180 deg dispertion, snap on spring mounting, Peak SPL 97dB complete with necessary mounting hardware & accesories. with backbox for true ceiling.
Supply, Installation, testing and commissioning of Blu ray DVD Player.
Supplying, laying and fixing of following size of FRLS PVC Insulated copper conductor, single core cable in the existing surface / recessed steel / PVC Conduit as required.
2 x 1.5 SQ mm Speaker cable Suitable for Music and Audio Signal
SITC of cat6 cable
SITC of 19-inch Equipment Rack with standardized frame or enclosure for mounting multiple PA controllers, CD player, FM sources, Amplifiers etc modules. Size 42U. Make: Heinrich/Valrack / President
Providing and Fixing of RED / Green Led lit laser double sided Acrylic Exit Fire Signage of size 350mm x220mm (Normal Size) Signage With Reflector , Uniformly Placed Extra Super Bright Led Having Power Consumption Less than 2 watt give an even illumination , mounted with suitable powder coated ms box with 6 hours maintained free backup , extension lead as per site requirement suitable for working on 230+/-20% 50Hz AC Supply and arrangment step down 6/12Volt DC marking connection , testing and commissioning etc as req
Providing and Fixing of RED / Green Led lit laser Single sided Acrylic Exit Fire Signage of size 350mm x220mm (Normal Size) Signage With Reflector , Uniformly Placed Extra Super Bright Led Having Power Consumption Less than 2 watt give an even illumination , mounted with suitable powder coated ms box with 6 hours maintained free backup , extension lead as per site requirement suitable for working on 230+/-20% 50Hz AC Supply and arrangment step down 6/12Volt DC marking connection, testing and commissioning etc as req.
SUB HEAD - VII EARTHING & LIGHTNING PROTECTION : Supply and Installation 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submainReceiving ,fixing and drawing wiring/ cable as required.
Supply and Installation earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
Supply and Installation earth bus of 50 mm X 5 mm GI strip on surface for connections etc. as required.
AIR TERMINATION SYSTEM: Supply, installation, testing and commissioning of 8mm Aluminium Solid Round Conductor for building terrace as a air terminal to meet the requirements of IS/IEC 62305 and IEC 62561-2.
Supply, installation, testing and commissioning of Roof conductor holder for parapet- Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance to meet the requirements of IS/IEC - 62305
Supply, installation, testing and commissioning of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. the requirements of IS/IEC 62305.
Supply, installation, testing and commissioning of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 16mm rod tapered to 10 mm aluminium rod : Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IS/IEC 62305) 4Mtr Airterminal: semi-hard (E- AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. the requirement of IS/IEC - 62305.
Supply, installation, testing and commissioning of Accessories : System consist of Fang Fix with base and clamp, on the top air terminal is erected. Fang fix clamp made of SS, lightning tested for 100 KA 10/350 micro sec waveform. 16 KG stone of 365 mm diameter, high level of stability. Quick and easy mounting of interception rod using anchors.
Supply, installation, testing and commissioning of 16 KG stone of 365 mm diameter, high level of stability. Quick and easy mounting of interception rod using anchors.Concrete, frost-resistant, can be stacked.
Supply, installation, testing and commissioning of Fang Fix Junior system - Inclusive of Al intrception rod of 1.5Mtr length(10mm dia ) , Quick mounting of the interception rod in the base using plug technology .
Supply, installation, testing and commissioning of of cross universal connector: For T and cross connection, to route vertical down conductor /mesh formation made of hot dipped galvanised iron with necessary screws etc as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts . the requirements of IS/IEC 62305.
Supply, installation, testing and commissioning of Expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. the requirements of IS/IEC 62305.
Supply, installation, testing and commissioning of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 62305)(2nos/expansion piece ). the requirements of IS/IEC 62305.
Supply, installation, testing and commissioning ofof Bridging cable: From flexible CU cable of 16mm2 with black colur coating, chlorinated India rubber mixture .Exclusively used for indoor & outdoor application to make continuity at terminals.
Supply, installation, testing and commissioning of Clamping shoe: Suitable to connect 8mm conductor ,quick installation with hexagonal bolts, 11mm dia attaching hole and shall be of Hot dip galvanised .
DOWN CONDUCTOR SYSTEM : Supply, installation, testing and commissioning of 8mm Aluminium Solid Round Conductor for building terrace as a air terminal to meet the requirements of IS/IEC 62305 and IEC 62561-2.
Supply, installation, testing and commissioning of Roof conductor holder for parapet- Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance to meet the requirement of IS/IEC - 62305.
Supply, installation, testing and commissioning of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip to meets the requirement of IS/IEC 62305.Tested for Electrical , Mechanical and chemical as per IEC 62561.
Supply of Lightning counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, Complies with IEC/EN 62561-6.
Supply, installation, testing and commissioning of Magnetic card with holder: To record lightning pulse with intensity.
EARTHING SYSTEM: Supply, installation, testing and commissioning of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor shall be of Hot Dipped & Cross sectional area of 90mm square According to DIN EN 50164-2 (VDE 0185 part 202) Meets the requirement of VDE0185/305(IS-IEC 62305) Zinc coating: 500 g/m square (Approx :70 micron coating) Should be tested and used exclusively for lightning protection earthing system and ring equipotential bonding.
Supply, installation, testing and commissioning of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate.
Supply, installation, testing and commissioning of flat conductor holder suitable for FL 30. Installed with 2 hexagonal bolts.
Supply, installation, testing and commissioning of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric.
Supply, installation, testing and commissioning of UL Listed & CPRI Tested maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 .
Supply, installation, testing and commissioning of Universal clamp made of SS to connect rod with flat conductor.
Supply, installation, testing and commissioning of Earth conductivity enhancing compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested.
Supply, installation, testing and commissioning of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system .
SUB HEAD - VIII UPS System : Supply, Installation, Testing and Commissioning of (3 phase-3 wire INPUT & 3 phase 4 wire OUTPUT) Online UPS system suitable for input and output parameters. The UPS shall have inbuilt Isolation Transformer. UPS operated in PRS Mode. Parallel Kit required. The UPS shall be provided in powder coated fan cooled enclosure painted in color. The UPS shall be suitable for normal, emergency, recharge, by-pass and maintenance mode through isolation transformer. The UPS shall have a microprocessor based display and control panel. UPS shall have own batteries with 15 minute battery back-up including MS Rack. as per DNIT
30KVA UPS
100 KVA UPS
SUB HEAD - IX CCTV SYSTEM, ACCESS CONTROL: Supply, installation, testing & commissioning of Indoor Fix Lens HD IR Dome camera with minimum specifications 1/2.7” 2Megapixel CMOS, 1080P resolution, 3.6mm Lens Lens, Output: AHD/CVBS View ,TDN (IR-Cut), AGC, 15-30m IR distance,Minimum illumination: 0 Lux (IR on) , 12VDC complete with wall mount bracket.
Supply, installation, testing & commissioning of Indoor Verifocal Lens HD IR Dome camera with minimum specifications 1/2.7” 2Megapixel CMOS, 1080P resolution, 3.6mm Lens Lens, Output: AHD/CVBS View ,TDN (IR-Cut), AGC, 15-30m IR distance,Minimum illumination: 0 Lux (IR on) , 12VDC complete with wall mount bracket.
Supply, installation, testing & commissioning of Varifocal lens HD IR Bullet Camera with minimum specifications 1/2.7” 2Megapixel CMOS, 1080P resolution, 3.6mm Lens Lens, Output: AHD/CVBS View ,TDN (IR-Cut), AGC, 15-30m IR distance,Minimum illumination: 0 Lux (IR on) , 12VDC complete with wall mount bracket.
Supply, installation, testing & commissioning of 30X optical zoom full HD IR PTZ Camera with minimum specifications 1/2.7” 2Megapixel CMOS, 1080P resolution, 3.6mm Lens Lens, Output: AHD/CVBS View ,TDN (IR-Cut), AGC, 15-150m IR distance,Minimum illumination: 0 Lux (IR on) , 12VDC complete with wall mount bracket.
Supply, installation, testing & commissioning of 64 Channel HD NVR , 1080P high resolution live view , Standard H.264 compression , Playback of upto 4 channel simultaneously , Multiple recording options: manual, schedule, motion detection , HDMI and VGA output simultaneously upto 1080P resolution, 1/2 SATA HDD interface: maximum ,6 TB storage capacity , CE, FCC certification
Supply Installation of 6 TB HDD complete with all accessories as required Approved Make : Seagate/WD
SITC of Central Management Software for Regional Control Room & Main Control Room
Supply & Fixing of 24 Port PoE Fast Ethernet WebSmart Switch, including 2 Gigabit BASE-T , 2 Gigabit Combo and 2 SFP Port BASE-T/SFP Network Switch Make-Netgear/Dlink/Cisco
Supplying Installation testing and Commissioning of Small Form Factor Pluggable 1 Gigabit Ethernet (SFP+) SR Optics
Supply, installation, testing & commissioning of 55" Full HD LED Display complete with all accessories as required.
Supply & Laying of cat 6 04 twisted Pairs cable with proper colour coding 10 / 100 Ethernet, 155 Mbps ATM, 1000 Mbps IEEE 802.3ab Ethernet, and proposed Cat 6 Gigabit Ethernet TIA/EIA 568-B.1 , IEEE 802.3ab,24 SWG .
Wiring of FRLS PVC insulated copper conductor, single core cable in surface / recessed 1.6mm thick GI Conduit as required.
2 x 1.5 sq. mm FRLS wire
ACCESS CONTROL SYSTEM : Supply, Installation, testing and commissioning of Surface mounted Networkable multiprocessor controlled. 4 reader controller capable of controlling multiple readers (IN/OUT) alongwith TCP/IP connectivity complete as per specifications. Control panel housed in MS Powder Coated Cabinet with Tamper Switch, Complete with power supply unit for Controllers & Magnetic Locks as per specification
Supply, installation, testing and commissioning of Access Control Application Software for 128 Reader Capacity, and 4000 Card Holder Capacity, Basic GUI , TA Module with Alarm Module, T+ Module, 2-Nos Client Work Stations,Module for using SQL DB , -MULTI Site Module.
Supply, installation, testing and commissioning of UL Listed Smart Card Reader fwith compatible support of weigand output, 13.56 MHz technology platform and complies with the ISO 15693 / 14443A standard for contact less smart card technology. Card reader must be configurable to read encrypted ISO14443A sectors using standard or custom read keys for Sign OUT Terminal. should be compatible with HID format cards. Encryption,All RF data transmission between the card and reader should be encrypted using a secure algorithm. Industry-standard encryption techniques and advanced key management systems should be used to avoid the risk of compromised data or duplicated cards. The reader should have audio transducer to provide various tone sequences to signify access granted, access denied, power up and diagnostics. Visually impaired cardholders can easily distinguish between access granted and access denied. High-intensity light bar should provide a clear visual status indication in red, green or amber, even in bright sunlight.
Supply, testing and commissioning of iClass Smart card
Supply, installation, testing and commissioning of Single Leaf Electro Magnetic Lock of Suitable Capacity(Min 600 lbs).
Supply, installation, testing and commissioning of Double Leaf Electro Magnetic Lock of Suitable Capacity(Min 1200 lbs).
Supply and Fixing of ''U'' Bracket with Accessories.
Supply and Fixing of ''L'' Bracket with Accessories.
Supply, Fixing and Laying of 8 Core multi strand, copper, unarmoured Cable (between the every readers & the access controllers).
Supply, Fixing and Laying of 2 Core x 1.5 Sq mm, multi strand, copper, unarmoured cable (between the controller and EM Lock/Request to exit button).
SUB HEAD - X ACTIVE AND PASSIVE PART FOR DATA & VOICE SYSTEM : Supplying, fixing, testing and commissioning of following patch cord including connections, ferruling etc. as required.
Cat 6 Patch Cord 1m -Blue for both end for data & voice
Supplying, installation, termination, testing & commissioning of following items including connection, numbering, painting etc. as required. Cat 6 24 Port Patch Panel - Loaded
Supplying, installation, terminations, Testing and commissioning of following server instruments as per technical specification including MS box having Glass door with locking facility at the front with ventilation fans, suitable arrangement for connection etc. as required. 42U Rack with Key Board Trey, Mounting Hardware, Cable Manager.
Supplying and fixing in position the following sizes of powder coated MS housing for telephone tag block with hinged & lockable door including supply & fixing of tag block made out from self extinguishing polystrene material, corrosion resistant, highly resistant to shock, strudy and maintenance free KRONE type telephone tag block complete as required. 10 Pair Krone Tag Block
40 Pair Krone Tag Block
100 Pair Krone Tag Block
Supplying, fixing, testing and commissioning of 500 pair telephone MDF consisting of tagblocks in groups of 10pair krone, disconnector type, complete withmetal enclosure powder coated, krone tag block mountingarrangement, telephone distribution chart and locking arrangement (for EPABX).
Supply, Laying, testing and commissioning of the following multi core 0.60 mm annealed tinned copper conductor PVC insulated and PVC sheathed and overall PVC sheathed armoured telephone cables complete with termination, joints etc complete with all accessories as required.
10 pair armoured riser cable
20 pair armoured riser cable
50 pair armoured riser cable
SUB HEAD - XI AV SYSTEM ( AUDITORIUM) : SOUND REINFORCEMENET SYSTEM SITC of hanging line array loudspeaker of 5” 2-way compact line array speaker system that permits both constant directivity control over a wide frequency range and changes in directivity. The Loudspeaker should have Max power output at 600W. , so different dispersion angle is easily directed. Sensitivity (1 W, 1 m) 96 dB (60゜ mode), 97 dB (45゜ mode), 98 dB (30゜ mode), 99 dB (15゜ mode), Frequency Response 70 Hz - 20 kHz (-10 dB) (60%%d mode), Directivity Angle Horizontal: 100゜ (2 kHz or more) Vertical: 60゜ (800 Hz or more).
Supply Installation Testing & Commissioning of 15" Two-Way System in a Trapezoidal Enclosure; 600W @ 8 ohm Continues Power Frequency 45Hz to 20KHz sensitivity 100dB
Supply Installation Testing & Commissioning of compact Professional 12" Audio and 2-way Loudspeaker in a Trapezoidal Enclosure; which was developed to be permanently installed for sound reinforcement in halls, theaters, concert venues and auditoriums 450W @ 8 ohm Continues, Cover Range (H)80° (V)60° and Power Frequency 40Hz to 20KHz sensitivity 101dB/1W/1M.
Supply Installation Testing & Commissioning of Array Frame for Suspending up to 6 Enclosures with 10:1 Design Factor. Includes 4 x Quick Release Pins, 2 x Shackles, 2 x Drop Levers. (For Speaker Installation)
Side Wall Speaker Mounting Braket
Supply Installation Testing & Commissioning of 2 x 18" Bass reflex Subwoofer system with 1000 watt or better Frequency response 25-200HZ long term power handling, 220 Megnatism with dual 18" LF driver,
Supply Installation Testing & Commissioning of compact Professional 12" Audio and 2-way Loudspeaker in a Trapezoidal Enclosure; which was developed to be permanently installed for sound reinforcement in halls, theaters, concert venues and auditoriums 450W @ 8 ohm Continues, Cover Range (H)80° (V)60° and Power Frequency 40Hz to 20KHz sensitivity 101dB/1W/1M.
Supply Installation Testing & Commissioning of 6"+1.5" Coaxial Ceiling speaker with ABS cover, 40W, 100V, cutout 185mm, ABS baffle & back cover, metal grille. The Speaker shall have following Feature: Max SPL > 102 dB, Frequency Response 90-20kHZ. The Speaker shall have Multiple tapping
Supply Installation Testing & Commissioning of Power amplifier, Dual channel 1600 + 1600 Watts RMS @ 8 ohms,Sterio power THD<0.1%, S/N Ratio 112dB Front-to-rear air ow, temperature controlled speed, Short circuit,open circuit,direct voltage,high temperature, radiofrequency, ultralow frequency, current peak limitery input connector 3-pin XLR, electronically balanced (Loc: Projector Room)
Supply Installation Testing & Commissioning of 500W RMS dual Channel Class-D Digital Power Amplifier with Switch power technology for power electricity saving. Amplifier shall have Following Features: 240W RMS per Channel, Amplifier Output 100V, Short Circuit, Power, Tempreature, Overload Protection, Auto Cooling Fans. THD <0.1%, Frequency Response 20Hz - 20kHz, AC & DC Fuse, SNR >80dB. (For Ceiling speakers) Loc: Projector room
Supply Installation Testing & Commissioning of 24 channels Mixing console with Mono Input 16 Channel, Stereo Input 4 group, Mono Insertion Channel 16 Channel, Phantom power 48V, Frequency Response 20Hz - 20kHz, Channel Crosstalk less than 90dB, S/N Ratio 83 dB, Gain difference between Channel less than 2 dB, Distortion degree less than 0.02%, 21 Kind of DSP Effects.
Supply Installation Testing & Commissioning of 8-channel Phantom Power Microphone/Line input, 8- channel circuit Output; Loudspeaker Management System Frequency Response 20Hz ~ 20KHz, THD <0.003%, Channel Seperation >92dB,Seperate Mute Control each channel,CMRR>80dB, 8 independent parametric EQ, adjustable gain range up to 20dB, With, RS232 and internet to connect PC,High-speed processing DSP Chip, the new generation of AFC algorithm to eliminate the feedback faster and make system more stable.Application includes Auto Mixer (Limiter threshold and Gain), Routing, Audio Processing and special signal extension Processing.
Supply Installation Testing & Commissioning of 50cm gooseneck cardioid Microphone, table top type polar pattern super heart-shape sensitivity -35dB frequency 60-14Khz output impedance <200Ohm operating Voltage DC9V(At podium)
Supply Installation Testing & Commissioning of Dynamic Vocal Microphone with cardioid polar pattern, frequency response 70Hz - 20kHz (@ 1 cm: 20Hz - 18kHz), THD 147/156 dB,Impedence <=600 ohms (Stage performance)
Supply Installation Testing & Commissioning of Floor Box for Connecting Mic ( 2 XLR Connector ).
Supply, Installation,Testing & Commissioning of handheld Wireless Mic system set with two transmitters dynamic microphone, Frequency Response 40Hz-15,000 Hz, Surge mode PLL Phase lock, Dynamic Range >90dB, THD < 0.5%, S/N ratio > 90dB, Carrier frequency range 720 - 830 MHz, Power Consumption < 85mA.
Microphone Tripod stand with Long Arms of Aluminium
Supply Installation Testing & Commissioning of Proffessional DVD player make Philips or equivalent
Supply Installation Testing & Commissioning of Wiring for Speaker 2x1.5sqmm sheilded cable system including miscellaneous connectors in PVC conduits.
Supply Installation Testing & Commissioning of 19" Rack Mount 24U Enclosure for Installing all sound reinforcement System and Video Project System
Supply and fixing 2C x 1.5 Sq.mm sheilded Microphone cable
VIDEO PROJECTION SYSTEM WORK IN AUDITORIUM: Supply Installation Testing & Commissioning of Projection System with DLP Technology, with native resolution of 1920 x 1200, 10000 lumens (Center) , 16:10 aspect ratio, light source - laser phosphor contrast ratio 10000:1, Uniformity - 90% or better, Power Consumption should not be more than 800W in normal mode, along with accessories make Panasonic , NEC, Barco
Supply Installation Testing & Commissioning of Long/Short Throw Projection Lens, complete as per Projector and as required.
Supply Installation Testing & Commissioning White Cyclorama Make - Draper/Dalite/Liberty
Supply Installation Testing & Commissioning of 4 In 2 Out VGA Switcher Make - Extron/Kramer or equivalent
Supply Installation Testing & Commissioning of VGA Cable for system in PVC conduits
Supply Installation Testing & Commissioning of Coaxial cable for system in PVC Conduit
Presentation Point on Stage
VIDEO PROJECTION SYSTEM WORK IN AUDITORIUM: SITC of 86" 4K professional display with 500 nits or more, 1000:1 or more contrast, Viewing Angle: 178 deg (H)/178 deg(V), 3 x HDMI, 1 x DVI/DP input, Controls: RS 232/Ethernet, DP Outx1 with inbuilt Signage software etc complete with installation along with suitable wall mount etc. as required.
Supply, Installation,Testing & Commissioning of Intelligent conference system .it can support 60 units delegate and chairman microphone, it could be extended to support 200 units microphone by adding more Extension power supply unit , suitable for government, restaurants, conference rooms, training and education, the board of directors of the company meeting room with Frequency response 100 Hz - 16000 Hz, Input Voltage 18V, Limit Switch and Free speech Mode.
Supply, Installation,Testing & Commissioning of Intelligent conference system, Table top boundry layer Chairman microphone unit , speaking button and LED for the indication, With president priority key; Chairman microphone should having highest priority and should be able to terminate all microphone. Frequency Response 40-16KHz, Sensitivity -42dB±2dB,Reference sound-receiving distance 20-120cm.
Supply, Installation,Testing & Commissioning of Intelligent conference system, Table top boundry layer delegate microphone unit, speaking button, LED for the indication and with Frequency Response 40Hz - 16KHz, Sensitivity -42dB±2dB,Reference sound-receiving distance 20-120cm.
SITC of 5"+1.5" Coaxial Ceiling speaker with ABS cover, 30W, 100V, cutout 210 mm, ABS baffle & back cover, metal grille. The Speaker shall have following Feature: Max SPL > 105 dB, Frequency Response 90-20kHZ.
SITC of 250W RMS Double Channel Class-D Digital Power Amplifier with Switch power technology for power electricity saving. Amplifier shall have Following Features: 250W RMS per Channel, Amplifier Output 100V, Short Circuit, Power, Tempreature, Overload Protection, Auto Cooling Fans. THD <0.1%, Frequency Response 20Hz - 20kHz, AC & DC Fuse, SNR >80dB.
SITC of 120W RMS Double Channel Class-D Digital Power Amplifier with Switch power technology for power electricity saving. Amplifier shall have Following Features: 120W RMS per Channel, Amplifier Output 100V, Short Circuit, Power, Tempreature, Overload Protection, Auto Cooling Fans. THD <0.1%, Frequency Response 20Hz - 20kHz, AC & DC Fuse, SNR >80dB.
SITC of 8-channel Phantom Power Microphone/Line input, 8- channel circuit Output; Loudspeaker Management System Frequency Response 20Hz ~ 20KHz, THD <0.003%, Channel Seperation >92dB,Seperate Mute Control each channel,CMRR>80dB, 8 independent parametric EQ, adjustable gain range up to 20dB, With, RS232 and internet to connect PC,High-speed processing DSP Chip, the new generation of AFC algorithm to eliminate the feedback faster and make system more stable.Application includes Auto Mixer (Limiter threshold and Gain), Routing, Audio Processing and special signal extension Processing.
SITC Of Digital feedback Suppressor with Dual-channel input, Each Channel has 12 auto- search feedback points. The Feedback Suppressor should be following features- Super-fast Automatic feedback control, detection time 0.4s @ 1KHz, The Potentiometer LED indicates the input signal power, Places filters with 0.5 HZ resolution, Provides more gain before feedback (6~9dB typical), Notch gain Max -48db, THD- ≤0.0025% @+4dBu /1KH z, SNR- ≥100dB (A).
SITC of handheld Wireless Mic system set with two transmitters dynamic microphone, Frequency Response 40Hz-18,000 Hz, Dynamic Range >98dB, THD < 0.5%, S/N ratio > 98dB, Carrier frequency range VHF 200MHz~270MHz, Sensitivity- -47±3dB@1KHz.
SITC of lappel Wireless Mic system set with two transmitters dynamic microphone, Frequency Response 40Hz-18,000 Hz, Dynamic Range >98dB, THD < 0.5%, S/N ratio > 98dB, Carrier frequency range VHF 200MHz~270MHz, Sensitivity- -47±3dB@1KHz.
SITC of 2 Core 1.5 Sq MM Speaker Cables. Flexible Copper Conductor of cross section 1.5 Sq. mm / 2.5 Sq. mm insulated, PVC sheathed control Cable as per IS 694.
SITC of 50cm gooseneck cardioid Microphone, table top type polar pattern super heart-shape sensitivity -35dB frequency 60-14Khz output impedance <200Ohm operating Voltage DC9V.
Supply, Installation,Testing & Commissioning of Intellectual control digital Podium system, microphone should be bendable. Digital Podium should have folowings features- Power- 220V/50~60Hz, Frequency Response- 100Hz~16, 000Hz, S/N ratio >45dB, Consumed Power- 100W and Loss of True- >0.5% (at AUX x 1W).
Supply Installation Testing & Commissioning of 16 channels Mixing console with Mono Input 8 Channel, Stereo Input 4 group, Mono Insertion Channel 8 Channel, Phantom power +48V, Frequency Response 20Hz - 20kHz, Channel Crosstalk less than 90dB, S/N Ratio 83 dB, Gain difference between Channel less than 2 dB, Distortion degree less than 0.02%.
Supply, Installation,Testing & Commissioning of Integrated Controller One RS- 232/422/485 COM port with hardware and software handshaking Two RS- 232 COM ports with software handshaking only 8 IR/serial, 8 relay, and 8 Versiport I/O ports Native BACnet®/IP support,Backwards compatible to run existing SIMPL programs Full Unicode (multi-language) support Increased network throughput and security,Secure access though Active Directory integration or standalone account management Hardware level security using 802.1x authentication,JITC certified model available for use in secure network environments,IIS v.6.0 Web Server,IPv6 ready,Front panel USB computer console port,1-space rack-mountable SDRAM: 512 MB,Flash: 4 GB,Memory Card: supports SD™ and SDHC™ cards up to 32 GB,External Storage: support USB mass storage devices up to 1 TB.
Supply, Installation,Testing & Commissioning of iPad,Apple iOS 8; 9.7-Inch Retina Display; 2048x1536 Resolution A8X Chip with 64-bit Architecture; M8 Motion Coprocessor Wi-Fi (802.11a/b/g/n/ac); 32 GB Capacity 8 MP iSight Camera; FaceTime HD Camera Up to 10 Hours of Battery Life
SITC of Cable Manager with 1 no. multiregion AC Power socket, , Black anodised/brushed aluminium finish,Tilt up lid with pass through holes for 1 HDMI, with audio, 1x LAN complete with CE, UL certification complete etc. as required.
Supply, Installation, Testing & Commissioning of 16x16 HDMI Matrix switcher .
Supply, Installation, Testing & Commissioning of 8x8 HDMI Matrix switcher .
Supply, Installation, testing and commissioning of required cable of HDMI, VGA, Audio, power, speaker, Microphone and conenctors as per site requirement etc complete required.
19" Rack for the mounting of Equipment as per approved OEM - 24U.
SUB HEAD - XIII SOLAR PV PLANTSupply, installation, testing & commissioning of Photovoltic solar system with solar photo voltic module (350Wp+/-2%), Module mounting structure foer meeting windload requirements , shop draeings and its vetting from reputed institution like NIT or equivalent , Array junction box, main junction box, solar Cu cables, power conditioning unit with invertor, Dc and AC distribution board, earthing kit, and all accessories as required to the complete satisfaction of Engineer in charge and taking permissions from HAREDA for net metering as per DNIT
SUB HEAD - I : HT PANELSupplying, installation, testing and commissioning of Indoor type floor mounted matel clad, 11KV VCB Panel made up of 2.5 mm thick CRCA Sheet with 4Nos. VCB,s (1 Incoming + 2 outgoings) totally enclosed and fully interlocked horizental isolation, draw out type breaker as per IS 13118, as amended up to date and as per additional specifications, having capacities as mentioned below, single break trip free mechanism, manually charged and manullay closing breaker suitable for use on 11KV, 3-Phase, 50 Hz A.C. supply with short circuit fault level of 350 MVA, complete with self contained fully interlocked, rack out mechanism, air insulated but encapsulated copper bus bar of 630 Amp, capacity , breaker featured with mechanical ON/OF indicator with hand trip device, spring release coil shunt trip coil and auxiliary switch of 4 NO + 4 NC and equipped with following switchgear and accessories i/c connections suitable for 3C x 240 Sq. mm, XLPE 11 KV grade cable (cable entry from bottom), end terminations with heat shrinkable jointing material etc. as required other details shall be as per Technical Specification & SLD. (Extra NO & NC shall be provided through multiplication relay OR through auxiliary contactor). details mentioned as per DNIT
SUB HEAD - II : DRY TYPE TRANSFORMER & HT CABLES : Supply,Installation,Testing and Commissioning of 1250 kva,DRY TYPE DISTRIBUTION (CRT) 11 KV /0. 433 KV Rating 3 phase, Double Wound with copper Winding. (As per ECBC 2017, IS : 11171 -1985 & IS : 2026/77), impedence 5%, Tapping Range Tappings +5% to –15% in steps of 1.25% shall be provided at line end of HV winding. Changing of taps shall be carried out by means ON Load tap changing, Insulation class : class F ,Temperature rise by Resistance : 90 deg.c , Ambient Temperature 50 deg.c, Dyn 11 vector group,Enclosure will manufactured from 14 SWG CRCA sheet. Enclosure Protection Class IP-23 with Siemens Grey paint, RAL-7032 and Other Standard Accessories as Required Including Followings : (including door interlocking ) including UL Listed Linear pneumatic heat Detection Tube with all necessary fittings & supports. Master Control Unit for controlling each system, complete with pressure switches, buzzers and electronic hooters, including all necessary accessories + electrical wiring to make each entire system functional. 45 Kg capacity CO2, IHP Valve Assembly with automatic valve, push in connector for tube,45 Kg CO2 gas & mounting bracket. details mentioned in DNIT
LT Switchgear IN ENCLOSURE433V LT switchgear with 2000A Tinned Copper busbars. Interconnection between Transformer and LT Switchgear shall be using Tinned Copper Busbar. Suitable for 05 nos- 3.5 c-300 sqmm XLPE AA Cable
1 No.Incomer :2000A, TPN, 50KA Electrically Draw Out type Air Circuit Breaker with Micro Processor Based protection release for O/L,S/C & E/F Protection in enclosure
2 No.25kVAR capacitor fixed type for compensation
HT Cables :-: Supply of following sizes of 11kV grade multicore aluminium conductor XLPE armoured power cable as per IS: 7098 ammended upto date as per the following size.
3C x 240 (E) Sq. mm
HT CABLE LAYING : Laying of one number PVC insulated and PVC sheatehd / XLPE power cable of 11 KV grade of following size in the existing masonry open duct / cable trench as required.
3C x 240 Sq. mm
HT Cables End Terminations :- : Supply and making Indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11KV grade as required.
3C x 240 Sq. mm
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 3 C x 150 Sq.mm
SUB HEAD III : MAIN LT PANEL AND DISTRIBUTION PANEL'SThe rates for the distribution boards from the Breakers and instruments shall also include the following :
MAIN LT PANEL : Supplying, Installation, Testing & Commissioning of cubical type LT. panel for 415V, 3 Phase, 50 Hz., 4 wire system, sheet steel clad, dust and vermin proof cubical and Indoor type floor mounted, free standing extendible type Main LT Panel compartmentalized design and fabricated out of 2 mm CRCA sheet steel complete with Aluminium Bus bars, Electrical interlocks as per the various status of all the equipments indicated on the drawings. Providing & Fixing of base plate / channel, P/F the following Switchgears, complete with earth Bus bar throughout the length of the panel, terminal arrangement for Cables incomings / Outgoings from Top / Bottom as per drawings and as approved by consultant / Engineer incharge, The incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement, detachable gland plates, adequate size cable alley, Sign writing, Painting, Earthing, Numbering, Danger plate etc. complete as required as per specifications and drawing attached.
Bus Couplers: 2000 A & 400 A 415V (Ics=Icu 50 & 35 KA for 1 second), 4 Pole, Electrical draw out type manually and Motorized ACB & MCCB with inbuilt micro processor based, Electrically interlock with ON / OFF indicating lamps and frame earthing contact, confirming to IS : 13947/3, 1993 as amended upto date complete in all respects as mentioned in specifications / drawing as required:-
Interlocking:
Electrical and Mechanical Interlocking through advance contacts / contactors in MCCB/ACB's (Incomers & Bus couplers) should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section as per single line diagram enclosed.
Bus bar:
2 Sets of 2000 Amp. TPN 50kA & 1 Set of 400 A TPN 35KA aluminum bus bars of suitable length. Bus bar shall be insulated by heat shrinkable sleeves and clip on shrounds for joints.
Outgoings : (Section-1)
Following rated 415V, ACB / MCCB's shall be microprocessor based with adjustable over current, short circuit and earth fault with time delay and instantaneous protection, all indication, front operating handle & door interlock etc. complete in all respects as mentioned in specifications and as required. For each outgoing:
1600A, 4P, MDO ACB with 50KA breaking capacity - 1Nos.
1000A, 4P, EDO ACB with 50KA breaking capacity - 2Nos.
800A, 4P, EDO ACB with 50KA breaking capacity - 1Nos.
630A, 4P, MCCB with 50KA breaking capacity - 2Nos.
500A, 4P, MCCB with 35KA breaking capacity - 2Nos.
260A, 4P, MCCB with 35KA breaking capacity - 3Nos.
Outgoings : (Section-2)
1600A, 4P, MDO ACB with 50KA breaking capacity - 1Nos.
1250A, 4P, EDO ACB with 50KA breaking capacity - 2Nos.
800A, 4P, EDO ACB with 50KA breaking capacity - 1Nos.
630A, 4P, MCCB with 50KA breaking capacity - 3Nos.
260A, 4P, MCCB with 35KA breaking capacity - 2Nos.
160A, 4P, MCCB with 25KA breaking capacity - 2Nos.
Outgoings : (Section-3)
260A, 4P, MCCB with 35KA breaking capacity - 2Nos.
125A, 4P, MCCB with 25KA breaking capacity - 2Nos.
100A, 4P, MCCB with 25KA breaking capacity - 2Nos.
63A, 4P, MCCB with 16KA breaking capacity - 3Nos.
Main LT Panel Described as above.
APFC Panel -1 & 2
Supplying, Installation, testing & Commissioning of Automatic Capacitor Control Panel with 625 KVAr capacitors comprising of (1 x 5 KVAr + 1 x 10 KVAr + 2 x 15 KVAr + 2 x 25 KVAr + 2 x 40 KVAr+ 4 x 50 KVAr + 3 x 100 KVAr) unit in a bank formation to achieve Automatic operation. The Panel shall be fabricated out of 2 mm thick sheet steel, dust & vermin proof and channel iron frame work of cubicle construction suitable at 415 volts, 3 phase, 50 HZ AC supply including interconnection, wiring, painting, earthing, labeling and providing danger plates etc. as per specifications
Incomer :-
1 No. 1600 Amps TPN MDO 50kA ACB with static release for overload & short circuit protection with fault indication on the release
Bas bar :
1 set of 1600 Amps TP strips AL. conductor bus bar and links.(BPTM type Heat-shrinkable busbar insulation)
One set of (3 Nos.) LED type RYB phase indicating lamps with 2 A SP MCBs for protection.
Power factor meter with Automatic P.F.C.R. & CT for unbalanced load - 1 Set.
Outgoings.
1 nos 20 amp TP 10 KA MCCB for 5 KVAr
1 nos 25 amp TP 10 KA MCCB for 10 KVAr
2 nos 32 amp TP 10 KA MCCB for 15 KVAr
2 no 63 amp TP 16 KA MCCB for 25 KVAr
2 no 100 amp TP 25 KA MCCB for 40 KVAr
4no 125 amp TP 25 KA MCCB for 50 KVAr
3 no 200 amp TP 35 KA MCCB for 100 KVAr
Capacitor Duty Contactor
1 no MO C X 5 ,with 1NO+1NC Auxilary contacts ,3 ph,400 V ,50Hz for 5 kVAR Rating
1 no MO C X 10 ,with 1NO+1NC Auxilary contacts ,3 ph,400 V ,50Hz for 10 kVAR Rating
2 no MO C X 15 ,with 1NO+1NC Auxilary contacts ,3 ph,400 V ,50Hz for 15 kVAR Rating
2 no MO C X 25 ,with 1NO +1NC Auxilary contacts ,3 ph,400 V ,50Hz for 25 kVAR Rating
2 no MO C X 40 ,with 1NO+1NC Auxilary contacts ,3 ph,400 V ,50Hz for 40 kVAR Rating
4 no MO C X 50 ,with 1NO+1NC Auxilary contacts ,3 ph,400 V ,50Hz for 50 kVAR Rating
3 no MO C X 100 ,with 1NO+1NC Auxilary contacts ,3 ph,400 V ,50Hz for 100 kVAR Rating
Detuned Harmonic Filters
1 nos. 5 KVAR, 415 V, MPP supper heavy duty type capacitor bank with 14% detuned reactor
1 nos. 10 KVAR, 415 V, MPP supper heavy duty type capacitor bank with 14% detuned reactor
2 nos. 15 KVAR, 415 V, MPP supper heavy duty type capacitor bank with 14% detuned reactor
2 nos. 25 KVAR, 415 V, MPP supper heavy duty type capacitor bank with 14% detuned reactor
2 nos. 40 KVAR, 415 V, MPP supper heavy duty type capacitor bank with 14% detuned reactor
4 nos. 50 KVAR, 415 V, MPP supper heavy duty type capacitor bank with 14% detuned reactor
3 nos. 100 KVAR, 415 V, MPP supper heavy duty type capacitor bank with 14% detuned reactor
Miscellaneous items
4nos door switch
4 nos illumination lights with 6 A,10kA MCB
ILLUMINATION LED WITH HOLDER & DOOR SWITCH
4 nos 6" dia exhaust fan with thermostate & suitable canopy
Internal illumination in Cable alleys with Door operated switch.
APFC Panel Described as above.
SUB PANELS
Fabrication supply, installing,testing & commission and connecting with main LT Panel of indoor type dust and vermin proof hinged and lockable doors at back side made out of 14 SWG CRCA MS Sheet including painting and complete with interconnections, Top entry, cable glands,removable gland plate, plugs, bonding to earth with 2 independent earth connections having 2 nos 25x6mm GI strip at bottom of panel as earth bus ,the construction of panel shall be compartmentalised, very compact, easy in maintenance .provision of ventilation shall be through axial flow fans system Legend plate of suitable size of showing panel no. and name of panel for outgoing feeder and as per the following and as per drawing.
AUDITORIUM WING LIGHT & POWER PANEL
INCOMER :-
1 No. 260 Amps 4P MCCB 35kA with overload & short circuit protection with fault indication on the release
Coloured (Red, Yellow, Blue) phase indicating lamp - 1 set
Digital flush type class-1.0 accuracy multifunction meter showing V, A, PF, KWH etc. with 3 Nos. current transformers of 260/5A ratio, 15 VA Class-1.0 metering. - 1 set
BUS BSR :
1 set of 300 Amps TPN strips AL. conductor bus bar and links.(BPTM type Heat-shrinkable busbar insulation)
OUTGOINGS :
40A, 4P, MCB with 10KA breaking capacity - 9Nos.
63A, 4P, MCB with 10KA breaking capacity - 9Nos.
100A, 4P, MCCB with 25KA breaking capacity - 1Nos.
Light & Power Panel Described as above.
LIFT PANEL
INCOMER :-
1 No. 260 Amps 4P MCCB 35kA with overload & short circuit protection with fault indication on the release
Coloured (Red, Yellow, Blue) phase indicating lamp - 1 set
Digital flush type class-1.0 accuracy multifunction meter showing V, A, PF, KWH etc. with 3 Nos. current transformers of 260/5A ratio, 15 VA Class-1.0 metering. - 1 set
BUS BSR :
1 set of 300 Amps TPN strips AL. conductor bus bar and links.(BPTM type Heat-shrinkable busbar insulation)
OUTGOINGS :
40A, 4P, MCB with 10KA breaking capacity - 3Nos.
63A, 4P, MCB with 10KA breaking capacity - 12Nos.
Lift Panel Described as above.
AUDITORIUM WING UPS PANEL
INCOMER :-
1 No. 100 Amps 4P MCCB 25kA with overload & short circuit protection with fault indication on the release
Coloured (Red, Yellow, Blue) phase indicating lamp - 1 set
Digital flush type class-1.0 accuracy multifunction meter showing V, A, PF, KWH etc. with 3 Nos. current transformers of 100/5A ratio, 15 VA Class-1.0 metering. - 1 set
BUS BSR :
1 set of 160 Amps TPN strips AL. conductor bus bar and links.(BPTM type Heat-shrinkable busbar insulation)
OUTGOINGS :
25A, DP, MCB with 10KA breaking capacity - 4Nos.
32A, DP, MCB with 10KA breaking capacity - 2Nos.
40A, 4P, MCB with 10KA breaking capacity - 2Nos.
63A, 4P, MCB with 10KA breaking capacity - 5Nos.
Audi wing UPS Panel Described as above.
UPS PANEL FOR BUILDING
INCOMER :-
2 No. 260 Amps 4P MCCB 35kA with overload & short circuit protection with fault indication on the release
Coloured (Red, Yellow, Blue) phase indicating lamp - 1 set
Digital flush type class-1.0 accuracy multifunction meter showing V, A, PF, KWH etc. with 3 Nos. current transformers of 260/5A ratio, 15 VA Class-1.0 metering. - 1 set
BUS COUPLER
260 A 4P MCCB 10KA with ON, OFF Indications.
Interlocking:
Electrical and Mechanical Interlocking through advance contacts / contactors in MCCB/ACB's (Incomers & Bus couplers) should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section as per single line diagram enclosed.
BUS BAR :
2 set of 300 Amps TPN strips AL. conductor bus bar and links.(BPTM type Heat-shrinkable busbar insulation)
OUTGOINGS :
Section-1
40A, DP, MCB with 10KA breaking capacity - 2Nos.
100A, 4P, MCCB with 25KA breaking capacity - 5Nos.
125A, 4P, MCCB with 25KA breaking capacity - 1Nos.
Section-1
40A, DP, MCB with 10KA breaking capacity - 2Nos.
100A, 4P, MCCB with 25KA breaking capacity - 3Nos.
125A, 4P, MCCB with 25KA breaking capacity - 3Nos.
UPS Panel Described as above.
VENTILATION PANEL
INCOMER :-
1 No. 500 Amps 4P MCCB 35kA with overload & short circuit protection with fault indication on the release
Coloured (Red, Yellow, Blue) phase indicating lamp - 1 set
Digital flush type class-1.0 accuracy multifunction meter showing V, A, PF, KWH etc. with 3 Nos. current transformers of 500/5A ratio, 15 VA Class-1.0 metering. - 1 set
BUS BSR :
1 set of 630 Amps TPN strips AL. conductor bus bar and links.(BPTM type Heat-shrinkable busbar insulation)
OUTGOINGS :
63A, TPN, MPCB with 10KA breaking capacity - 14Nos.
40A, TPN, MPCB with 10KA breaking capacity - 4Nos.
20A, TPN, MPCB with 10KA breaking capacity - 2Nos.
16A, TPN, MPCB with 10KA breaking capacity - 2Nos.
Ventilation panel Described as above.
SMOKE EXTRACTION PANEL
INCOMER :-
1 No. 1250 Amps 4P EDO ACB 50kA with microprocessor based realese overload & short circuit protection with fault indication on the release
Coloured (Red, Yellow, Blue) phase indicating lamp - 1 set
Digital flush type class-1.0 accuracy multifunction meter showing V, A, PF, KWH etc. with 3 Nos. current transformers of 1250/5A ratio, 15 VA Class-1.0 metering. - 1 set
BUS BSR :
1 set of 1600 Amps TPN strips AL. conductor bus bar and links.(BPTM type Heat- shrinkable busbar insulation)
OUTGOINGS :
300A, 4P, MCCB with 50KA breaking capacity - 2Nos.
63A, TPN, MPCB with 10KA breaking capacity - 29Nos.
40A, TPN, MPCB with 10KA breaking capacity - 9Nos.
Smoke Extraction Panel Described as above.
LIFT WELL PRESSURIZATION PANEL
INCOMER :-
1 No. 300 Amps 4P MCCB 35kA with overload & short circuit protection with fault indication on the release
Coloured (Red, Yellow, Blue) phase indicating lamp - 1 set
Digital flush type class-1.0 accuracy multifunction meter showing V, A, PF, KWH etc. with 3 Nos. current transformers of 300/5A ratio, 15 VA Class-1.0 metering. - 1 set
BUS BSR :
1 set of 320 Amps TPN strips AL. conductor bus bar and links.(BPTM type Heat-shrinkable busbar insulation)
OUTGOINGS :
40A, TPN, MPCB with 10KA breaking capacity - 25Nos.
32A, TPN, MPCB with 10KA breaking capacity - 2Nos.
Lift Well pressurization panel Described as above.
PLUMBING PANEL
INCOMER :-
1 No. 160 Amps 4P MCCB 25kA with overload & short circuit protection with fault indication on the release
Coloured (Red, Yellow, Blue) phase indicating lamp - 1 set
Digital flush type class-1.0 accuracy multifunction meter showing V, A, PF, KWH etc. with 3 Nos. current transformers of 160/5A ratio, 15 VA Class-1.0 metering. - 1 set
BUS BSR :
1 set of 200 Amps TPN strips AL. conductor bus bar and links.(BPTM type Heat-shrinkable busbar insulation)
OUTGOINGS :
125A, 4P, MCCB with 25KA breaking capacity - 2Nos.
63A, TPN, MCCB with 16KA breaking capacity - 2Nos.
32A, TPN, MCB with 10KA breaking capacity - 3Nos.
25A, TPN, MCB with 10KA breaking capacity - 5Nos.
16A, TPN, MCB with 10KA breaking capacity - 3Nos.
Plumbing panel Described as above.
STP PANEL
INCOMER :-
1 No. 125 Amps 4P MCCB 25kA with overload & short circuit protection with fault indication on the release
Coloured (Red, Yellow, Blue) phase indicating lamp - 1 set
Digital flush type class-1.0 accuracy multifunction meter showing V, A, PF, KWH etc. with 3 Nos. current transformers of 125/5A ratio, 15 VA Class-1.0 metering. - 1 set
BUS BSR :
1 set of 160 Amps TPN strips AL. conductor bus bar and links.(BPTM type Heat-shrinkable busbar insulation)
OUTGOINGS :
63A, TPN, MCCB with 16KA breaking capacity - 2Nos.
32A, TPN, MCB with 10KA breaking capacity - 9Nos.
25A, TPN, MCB with 10KA breaking capacity - 5Nos.
16A, TPN, MCB with 10KA breaking capacity - 3Nos.
STP panel Described as above.
FIRE FIGHTING PANRL
INCOMER :-
1 No. 630 Amps 4P MCCB 50kA with overload & short circuit protection with fault indication on the release
Coloured (Red, Yellow, Blue) phase indicating lamp - 1 set
Digital flush type class-1.0 accuracy multifunction meter showing V, A, PF, KWH etc. with 3 Nos. current transformers of 630/5A ratio, 15 VA Class-1.0 metering. - 1 set
BUS BSR :
1 set of 800 Amps TPN strips AL. conductor bus bar and links.(BPTM type Heat-shrinkable busbar insulation)
OUTGOINGS :
500 A, 4P, MCCB with 50KA breaking capacity - 2Nos.
125A, TPN, MCCB with 25KA breaking capacity - 2Nos.
63A, TPN, MCCB with 16KA breaking capacity - 2Nos.
16A, TPN, MCB with 10KA breaking capacity - 2Nos.
Fire Fighting panel Described as above.
EXTERNAL LIGHT PANEL
Design, Manufacture, Supply, Installation, Testing and Commissioning of Panel Fabricated out of 16 SWG CRCA sheet steel, IP 54, wall / floor mounting type with rain canopy The sheet steel shall undergo minimum 7 tank treatment followed by finishing powder coating of min 60 micron thickness. the board includes 415 /240 V electrolitic Aluminium Bus Bar, removable gland plates, cable glands, including connection with outgoing feeders complete in all respect, Panel Should Have Double Earthing Provision Which Connected to the Nearest Earth Grid.
INCOMER:
BUS BAR
TPN Aluminium bus bar with heat Shrink Sleeve rated for 160A.
OUTGOING
15 nos 32A DP MCB ON indication lamps with 9 nos astronimical time swtich for automaitc switching of landscape light fixtures at sun set and sun rise or twillight ( auto on/ auto off and auto mode)with manual override faiclity with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site.
2 nos 40A DP MCB (GUARD ROOM)
2 nos 63A 4P MCB (SPARE)
2 nos 40A DP MCB (SPARE)
Other items such as
1 Set of control wiring
1 Set of designation plates
All Items complete as above
TOTAL
SUB HEAD - IV : LT CABLE AND ACCESSORIES
L.T. CABLE
Supplying of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required
4Cx4 sq.mm
2Cx6 sq.mm
4Cx6 sq.mm
4Cx10 sq.mm
4Cx16 sq.mm
4Cx25 sq.mm
3.5Cx35 sq.mm
3.5Cx50 sq.mm
3.5Cx70 sq.mm
3.5Cx95 sq.mm
3.5Cx120 sq.mm
3.5Cx150 sq.mm
3.5Cx185 sq.mm
3.5Cx240 sq.mm
3.5Cx300 sq.mm
1Cx35 sq.mm CU
1Cx185 sq.mm CU.
Supply and Laying of heavy duty copper armored cables 1.1 KV grade including necessary support clamps at ceiling level and connection legs,glands etc complete in all respects.
Control cable 10 core 2.5 Sq.mm
Control cable 12 core 2.5 Sq.mm
LT CABLE LAYING
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying and of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in existing RCC/HUME/METAL pipe as required
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
LT CABLE JOINTING & END TERMINATION
Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required.
4Cx4 sq. mm (25mm)
2Cx6 sq. mm (28mm)
4Cx6 sq. mm (28mm)
4 X 10 sq. mm (25mm)
4 X 16 sq. mm (28mm)
4 X 25 sq. mm (28mm)
3½ X 35 sq. mm (32mm)
3½ X 50 sq. mm (35mm)
3½ X 70 sq. mm (38mm)
3½ X 95 sq. mm (45mm)
3½ X 120 sq. mm (45mm)
3½ X 150 sq. mm (50mm)
3½ X 185 sq. mm (57mm)
3½ X 240 sq. mm (62mm)
3½ X 300 sq. mm (70mm)
1Cx35 sq.mm
1Cx185 sq.mm
TOTAL
SUB HEAD - V : CABLE TRAY & SEFTY EQUIPMENTS
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. (Cable Tray Bends as per Requirement)
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 1.6 mm thickness
600 mm width X 75 mm depth X 2.0 mm thickness
750 mm width X 75 mm depth X 2.0 mm thickness
900 mm width X 75 mm depth X 2.0 mm thickness
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single Red colour on front side as required.
Supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required.
SITC of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board with supply of all material labour T & P etc for proper completion of work. (Approx front area = 1.20 sq M)
SITC of First aid box as approved by Indian red cross conforming to IS : 2217.
SITC of CO2 Fire Extinguishers 4.5 kg capacity complete in all respect ISI : 15683 marked
SITC of ABC FIRE EXTINGUISHER 4 KG capacity complete in all respect ISI : 15683 marked
SITC of Fire Bucket stand made of M S angle suitable for and with 4 Nos Fire Buckets of 9.5 Ltrs capacity
SITC of of rubber gloves of 11 KV grade as per IS : 4770.
SITC of ANTI SKID RUBBER MAT 1 mtr x 2 mtr. 3mm thick ISI - 15652 marked
TOTAL
SUB HEAD VI : DG SETs
SITC of “Silent Type” following KVA Sound Attenuated DG Set comprising of engine coupled to 415V, following KVA alternator mounted on a common Base Frame along with other accessories i.e. Engine Control Panel Auto/Manual (Mounted on Engine), Fuel tank, Batteries with leads i/c AMF Panel etc. as reqd. complete. The DG Set should be supplied with cable end box to accommodate suitable size and no. of cable on alternator complete as reqd. The canopy should be designed in such a way so that the Noise level can be restricted to 75 db level at a distance of 1 meter away from the DG Set.
Diesel Engine:
Diesel engine 4 stroke, water cooled, electric start, of suitable BHP at 1500 RPM suitable for following KVA output of alternator at 40 Degree C, 50%RH & at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories.
Engine mounted Instrument Panel (Auto/Manual) fitted with and having digital display for following:
(i) Start-stop switch with key
(ii) Water temperature indication
(iii) Lubrication oil pressure indication
(iv) Lubrication oil temperature indication
(v) Battery charging indication
(vi) RPM indication
(vii) Over speed indication
(viii) Low lub. Oil trip pressure indication
(ix) Engine Hours indication
Alternator :
Synchronous alternator rated at following KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self- regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class-F/H insulation.including controller PC 3.3
Base Frame & Foundation FOR Engine and Alternator:
Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.
Base Frame & Foundation For Daily Service Fuel Tank:
Daily service fuel tank of 990 liters capacity fabricated out of 3mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.
Exhaust System:
Dry exhaust manifold with hospital exhaust silencer and catalytic convertor.
Starting System:
24v DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (25 plates, 180 Amp / as per OEM.- Hour capacity lead acid type) as required as per specifications.
Acoustic and weather proof enclosure
Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per specifications.
Supplying and fixing exhaust gas piping of suitable dia. welded black MS, B Class pipe conforming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral wool/Rockwool,50 mm thick wiremesh & aluminum cladding etc., as required as per specifications
200 KVADG Set
1250 KVADG Set
TOTAL
SUB HEAD VII : SUPPLY OF EXTERNAL LIGHTING SYSTEM
Supplying and fixing integral post top lantern with 40 watt LED fitting comprises of copper dust finish cast aluminium spigot and spun aluminium canopy fixed with opal polycarbonate, pipe arrangement for vertical mounting, open construction driver and accessories are wired up to terminal block. LED of 1 to 3 W each assembled on single MCPCB, having color temp 6500K & having 50000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy>80lm/W. LED driver PF 0.95 & surge protection 2KV.The colour rendering index of LED light should be more than 70. Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer manadatory. i/c connection wire, testing etc. to complete the job. 2 Yrs Guarantee certificate from manufacturer.
Supply , Installation, Testing & Commissioning of 13 W LED Mono ground recessed upligthing luminaire with Die-cast aluminium,tempered transparent glass cover, power consumption of 13W with lumen output of 700. The Luminaire body uses high pressure die- casting aluminium. The cover uses stainless steel while the buried barrel uses high-quality corrosion resistant nylon . Luminaire has a choice of architectural uplighting optics with options of beam angles of 10, 25,40, 60 degrees with dynamic 16 million color combinatonscolors. The diffuser use thickened toughened glass, having an advantages in impact resistance and abrasion. the diffuser and light cover is at the same level. Luminaire should have IP67 and Impact Resistance of IK 10, THD should be less than 10, Inbuilt BIS approved driver. Luminaire should be capable of operating at line voltage of 230V AC. Excellent design in heat radiation performance, So that the temperature of the cover is low, which is safe and provide good protection. High strength toughened glass, can withstand a weight of 2500KG and glass surface temperature limits below 40°C. Dimensions-diameter 186 height-116mm. Havells ENGROSS MINI 13W Mono. To be supported with Product test reports - LM79, Is 10322/IEC 60598 and for LEDs - LM80, RoHS and Photo Biological Safety certificate.
Supplying, fixing & testing of approved make of integral type bollard cyclindrical shape housing cast aluminium dome shape top cover fixed with cylindrical shape poly carbonate cover having base plate with holes for direct mounting complete with all accessories and control gear box (with 1x 9watt LED lamp) including preparatoion of foundation including fixing with connection and all required material as require
Supply, Installation, Testing and Commissioning of 45 Watt Solar Street Light luminaire with inbuilt SCC made IP66 & with MPPT (Maximum Power Point Tracking) which provides about 25% more charging efficiency by utilizing maximum energy harvested by solar PV modules. System should designed to withstand highly corrosive atmosphere and heavy wind loads. The modules are certified for industry standards IEC61215, IEC61730 (safety class 1 & 11), IEC61701 along with 6 Mtr. octagonal pole with 200 (100x2) AH lead acid battery & 240 (120x2) Wp solar panel Total lumen output should not less than 6300 lumen Complete with all Accessories & Control Gears etc.
Supply, Installation, Testing & Commissioning of LED Step Light, fixture should be: IP 66and IK 07 made up Pressure die-cast aluminium housing for sturdiness, excellent corrosion resistant and efficient thermal management grey finish and Clear poly carbonate cover Length (L) 196mm, Width (W) 129mm, Height (H) 85mm, with Operating temperature: - 10°C to +45°C. wide and symmetrical light distribution with system wattage of 7W, with system Efficacy of 25 lm/w or more, system lumens > 180 lms ,Powered by an integral isolated led driver with insulated sleeve and Power factor > 0.90, CRI > 70, CCT 3000K (ANSI Tolerance),THD(%) < 15, LED chip of Nichia, Osram, Cree make, LED Lamp Efficacy > 100 Lm/W with Average life L70B50 @ 35000 hourss, Interal Driver SPD of 2.5kV. The product should be BIS approved with R number mentioned on product label. Havells make RADIANTNEOFT07WLED830SASYMBOPC.
Supply , Installation, Testing & Commissioning of 9W LED spike light with lumens > 800 lms, Power factor > 0.95, CRI > 80 with IP66 and IK07 Gray pure polyester powder coated ,Pressure die-cast aluminum housing for efficient thermal management, sturdiness & excellent corrosion resistance & High quality toughened glass in clear finish for uniform light distribution. The housing provides IP66 protection for high reliability in outdoor applications. High efficiency long life COB LED mounted on MCPCB of fixture. Lumen efficacy of LED >140 lm/W. . with aluminum heat sink for effective thermal management with Operating temperature: -10°C to +45°C. Havells LYCUSSPS9WLED730PSYMBOTG. The product should be BIS approved with R number mentioned on product label.
Supply , Installation, Testing & Commissioning of 25W LED Up-Down Facade light with lumens > 800 lms, Power factor > 0.95, CRI > 80 with IP66 and IK07 Gray pure polyester powder coated ,Pressure die-cast aluminum housing for efficient thermal management, sturdiness & excellent corrosion resistance & High quality toughened glass in clear finish for uniform light distribution. The housing provides IP66 protection for high reliability in outdoor applications. High efficiency long life COB LED mounted on MCPCB of fixture. Lumen efficacy of LED >140 lm/W. . with aluminum heat sink for effective thermal management with Operating temperature: -10°C to +45°C. Havells LYCUSSPS9WLED730PSYMBOTG. The product should be BIS approved with R number mentioned on product label.
Supply, Installation, Testing and Commissioning of 202x238x111 (KVPC) Polycarbonate thermoplastics enclosure - junction box with I.P - 65 Protection with cable hinged cover of approved design complete having gasket of internally embedded & made of polyeutherene & should be weather proof, rust proof, dust proof, water proof - box shall be tested as per IEC - 60670-2/60670-22. the box shall have self threaded holes & provision for mounting din rail. with 2 Nos cable gland including supplying & fixing crimping 2 nos lugs & 1 nos 32A connector 6 way for looping the incoming & outgoing cables and also connection of the street light one 6A SP MCB Including Connection of 2x6 sqmm Cable etc as Required
Supplying of 8 mtr long hot dip Galvanized octagonal Pole with top of the pole 70 mm dia (A/F) and bottom of the pole 135 mm dia (A/F) made out of 3mm sheet with MS base plate of size 225mm (NS) x 225mm (NS) x 16mm (NS) on precast RCC foundation complete with suitable size opening inside the pole with flush weather proof door with locking facility preferably with LN key having proper arrangement with Accommodating of 1 Nos. 6 Amp.,10 KA MCB & neutral link 4 way connector suitable for 25 Sqmm cable complete with electrically safe including inside cable termination with thimbles i/c wiring from pole box to fitting with 3x1.5 sq.mm. FRLS PVC insulated copper conductor wire, earth connection, din channel, earth stud and other accessories pertaining to this pole (But without street light fitting) etc as reqd.including providing & laying in position suitable RCC foundation as required for 6 mtr. octagonal hot dip Galvanized Pole as per Manufacturers drawing with 1:1.5:3 concrete (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) including excavation of all kind of earth such as all type of soil/soft rock or hard rock etc. as per existing site condition i/c providing, cutting, bending and placing reinforcement & J type foundation bolts , anchor plate and templates in position as per manufacturer Standard and Providing PVC Pipe for Cable Entry and Exits Including Disposal of Surplus Malba / Softrock / Hardrock Stone etc.as Required.
Supplying of Following sizes 1100 volt grade XLPE insulated PVC sheathed aluminium conductor armoured cables as per specification in existing laid in ground including cost of digging upto required depth, 150 mm sand all around the cable, brick protection and back filling, clamped to wall with suitable clamps including saddles fixing bolts, connection testing and commissioning as Required.
4x6 sqmm
Supplying, Drawing, Connecting and Testing of Following Size of PVC Insulated FRLS Copper Conductor (as per IS : 694) flexible Multicore Wire in the existing poles and bracket from cable termination connector / MCB to the fitting i/c providing suitable connectors
3 core 2.5 sq.mm (for 8Mtr Poles + POST TOP+ BOLLARD)
RCC Hume pipes
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required
300 mm dia
250 mm dia
100 mm dia
Manholes
Preparing the man holes of followign sizes for 11 kv & LT cables as per the route provided in the drawing and as per the site conditions in guidance of the site incharge at sit
800 x 800 x 800 size
1200 x 1200 x 1200 mm size
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required
120 mm dia (OD-120 mm & ID-103 mm nominal)
160 mm dia (OD-160 mm & ID-135 mm nominal)
200 mm dia (OD-200 mm & ID-175 mm nominal)
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required
Above 4.5 meter and upto 8.5 meter
Supply, Installation , Testing, Commissioning and Handling over of 13 Passenger Elevator
(Not less than 884 kg) of approved Reputed brands (Otis/ Schindler/ Kone/ Mitsubishi)
Energy efficient,Gearless elevator, machineroom less ,with speed of 1 m/ sec. in the existing lift shaft as per specification of tender document complete in all respects.
as per Satisfaction of Engineer-in-charge including obtaining
permission from concerned Govt regulatory/ authority with following specs
IS: 4666. 1968 for electric passenger lifts and shall further
Comply to IS : 1860:1960, IS: 63831,1971, IS: 732: 1963
and Bombay lift act 1943 amended up to date.
Traction steel Hoist ropes / Belt Drive as per relevant ISI code.
Operation : Microprocessor based simplex / duplex collective full collective
Drive : Variable voltage variable frequency (V3F) with Regenerative Drive
Doors Automatic Centre / side opening Door panel of Stainless Steel in Hairline finish, Automatic rescue operations with infra red sensors Machine
: Gearless Machine to be placed directly above Hostway
including the cost of machine room and pit as per manufacturer specs
The guide rails should be steel dually toughened and ground
section to ensure position tract and smooth runing of the
elevator. Guide rails.
Design of car body Constructed out of Stainless Steel Hairline finish Car and
Car Doors with Stainless Steel handrail. And Poly vinyl tile flooring
Car light to be LED tube light fitting to have daylight effect inside the
Car cabin. Fan/blower in the car as per manufacturing enriched design.
Floor position indicator at all floors along with direction of
travel indicator.
Power supply shall be provided as under:
A. 415 volts, 3 phase, 4 wires 50 Hz
B 230V, Single Phase, 50 Hz for lighting.
C. All electric cables, controls switchgears should be
stricty as per ISI.
Signals : (A) Luminous hall buttons at all floors.
(B) Digital hall position indicators at all floors.
(C) Car operating panel with luminous floor buttons
(D) Digital car position & Direction indicator.
(E) AC/ DC VF Door Drive.
(F) Emergency light & emergency alarm through inverter
(Rechargeable batteries).
Spring buffers or as per suppliers design
Defect Liability : 3 years from date of handling over of lifts as per details
mentioned in terms & conditions attached herewith.
The lift suppliers include Cost of
1 Scaffolding inside the hoist way for erection
2 Cutting of walls with repair
Including all of bolts members indicator and button
boxes etc. in position.
3 Sill angles, fascia plates, machine
Beams and rolled steel section with bearing plates for
support of the nmachine if required.
4 Door frames.
5. Pit Ladder
Car safety and Governor to control excessive descending speed.
Counter balance to promote smooth and economic operation.
Terminal and final limits.
Terminal buffer.
Controller to control starting speed of elevator motor and supply brake automatically in case of
application of any of the safety device or power failure.
Steel glides for the car and counter weight.
The elevator should be equipped with the over speed governor safety system.
Inspection unit shall be provided at the top of car.
Rechargeable battery based Emergency light & alarm.
Fireman's Switch
Door open & Door close button
Full Height Infrared Curtain
Auto On/Off for car light and fan
inclusive of Cost of voltage stablizer (if required) and SMF Batteries.
inclusive of GST tax,excise duty, Freight, etc.
Insurance transit and up to handling over of lift.
No of stoppage 13, total height 59.55 m from Basement 3 to 9 th floor and terrace
No of stoppage 14 total height 63.75 m from Basement 3 to 10 th floor and terrace
No of stoppage 7 total height 25.95 m from Basement 3 to 10 th floor and terrace
HVAC SYSTEM
EQUIPMENT
OUTDOOR UNITS (HEAT PUMP TYPE)
Supplying, installing, testing and commissioning of aircooled variable refrigerant volume / Flow modular type airconditioning system with R410a refrigerant. The PCB Chamber of outdoor unit should be refrigerant cooled suitable for 415±10% 3 Phase, 50 cycles. The unit shall consist of indoor and out door units with individual controller as per detail given in specifications and having following items : (These items are to be given in Indian rupees with custom duites, inland frt,clearance etc on Site basis)
Modular type outdoor units equipped with highly efficient 100% inverter type hermitically sealed scroll compressors, minimum two comprossors for and above 14 HP modules, with special precoated heat exchanger, low noise condenser fan housed in compact housing duly powder coated and manufacturer of compressor and outdoor unit should be same. The Unit should have automatic refrigerant charge function. The static pressure of the outdoor unit shall be more then 78 Pa to avoid hot air recirculation. The unit shall be able to operate upto to 49°C in cooling mode.The unit shall also have feature to automatically modulate the evaporative temperature between 6 deg C to 11 deg C with respect to load for better comfort and energy efficiency etc complete as reqd. The units should have free phase technology for countinued operation. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping .The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 of following capacitites:
Cost of R 410 A Gas should be inclusive
The outdoor unit should include all loading, unloading, transportation, power cabling/wiring from near the indoor and outdoor units respectively.
Outdoor Units-Heat Pump , Fully Gas Charged and Aluminum fins within the ODU (condensing) unit shall be coated with polysiloxane based coating.
The Vendor should considere the deration on ODU election as per Greater Noida Ambient conditions
50 HP Outdoor unit VRV/VRF Zone-01,03,
48 HP Outdoor unit VRV/VRF Zone-02,08
54 HP Outdoor unit VRV/VRF Zone-04,09
52 HP Outdoor unit VRV/VRF Zone-05
38 HP Outdoor unit VRV/VRF Zone-06,16,19
36 HP Outdoor unit VRV/VRF Zone-07,11,12
40 HP Outdoor unit VRV/VRF Zone-10
34 HP Outdoor unit VRV/VRF Zone-13,14
42 HP Outdoor unit VRV/VRF Zone-15
44 HP Outdoor unit VRV/VRF Zone-17,18,20
INDOOR UNITS
Supply, installation, testing and commissioning of following Wall Mounted /Cassette type units with panel and inbuilt drain pump/slim Ceiling Mounted duct type/Ceiling Mounted Built in type/Ceiling Mounted Ductable type units VRF Air Conditioners with cordless/corded remote controller.Fully Factory assembled,wired and tested Indoor Units as per specifications ans as required to make the system complete. Aluminum fins within the IDU (evaporator unit) shall be coated with polysiloxane based coating, The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System.
Ceiling Mounted HSP Ductable Unit
525-560 CFM / 1.25-1.30 TR
565-635 CFM / 1.5-1.60 TR
650-740 CFM / 1.7-2.0 TR
875-883 CFM / 2.5-2.60 TR
1130 -1150 CFM / 3.0-3.40 TR
1200-1377 CFM / 3.95-4.0 TR
Ceiling Mounted MSP Ductable Unit
310-320 CFM / 0.80 TR
400-425 CFM / 1.00-1.02 TR
Accessories
SITC of Expansion Kit Required for the above AHU to make the system complete
SITC of Control Kit Required for the above AHU to make the system complete
REMOTE CONTROLLERS
Supply, installation, tesing and commissioning of Imported Remote controllers (Corded) for operation of ductable indoor units and AHU's.
Supply, installation, tesing and commissioning of Imported Remote controllers (Cordless/Corded) for operation of Hiwall/Cassette/ Ceiling Concealed indoor units.
Touch screen controller for indoor units controller - VRV
Supply, installation, testing and commissioning of touch screen controller (Which is controlled 110 nos. indoor units in terms of ON/Off Status, temp. Status, Fan Speed, ODU On/Off Status etc.) with all accessories and controls.
Supply, installation, testing and commissioning of touch screen controller (Which is controlled 20 nos. indoor units in terms of ON/Off Status, temp. Status, Fan Speed, ODU On/Off Status etc.) with all accessories and controls.
PDI With Anergy Meter
Supply, installation, testing and commissioning of PDI (Power Distribution Indicator) with digital anergy meter Centralized Controller (Which can control 1 PDI per 1 ODU Set) units in terms of accumalted total power/current consumption of each indoor units, Power Failure, Data back up etc.) with all accessories , wiring and controls. Its connectable to PC based central controller(BMS).
REFNUTS / Y-JOINTS
Supply, installation, tesing and commissioning of Imported fittings Y-joints insulated, distributer and headers for all Indoor units at both the ends floors layout as per layout drawings.All interconnecting joints, Y Joints with polysiloxane based coating
REFRIGERANT PIPING
Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with (13/ 19mm thick) cross linked closed cell Oxide Acetate Foam tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with hangers and All interconnecting Copper piping, joints, U bends with polysiloxane based coating shall run in cable tray. (Note: Ref. Piping Length may be review as per site routing)
06.35 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation
09.52 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation
12.70 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation
15.88 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation
19.05 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation
22.22 mm with 19 mm thick cross linked closed cell Oxide Acetate Foam insulation
28.58 mm with 19 mm thick cross linked closed cell Oxide Acetate Foam insulation
34.92 mm with 19 mm thick cross linked closed cell Oxide Acetate Foam insulation
41.30 mm with 19 mm thick cross linked closed cell Oxide Acetate Foam insulation
TRANSMISSION & CONTROL WIRING
Supply, installation, testing, termination and commissioning of control cum transimission wiring (should be shielded cable in PVC Pipe) of 2C x 1.5 Sqmm Cu between indoor unit and out door unit and indoor units and its remote controller.
2C x 1.5 Sqmm Cu Cable or as per Manufacturer OEM
Perforated GI Tray with hangers & supports for copper piping (250 mm wide)
Refrigerant-410a
Supply , charging & Leackage testing of refrigerant -410a in additional copper piping circuit.
AIR HANDLERS (With One Coil System)
Supply, installation testing and commissioning of factory built floor/Ceiling mounted chilled water Double skin type horizintal/vertical air handling units made of 40mm ±2mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layerand 0.8mm inside layer with polyurethene foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required , min. 2 bend GSS/PVC eliminators, DX cooling coil section with aluminium finned copper tubes ( tube thickness not less than 0.5 mm ) DX cooling coil of 6 row deep, filter section with 50 mm thick metal viscous filter /washable synthetic type air prefilters, AHU Blower Direct driven with VFD , squirel cage induction motor (Plug fan with VFD) package with TEFC drive motor of efficiency class IE3 suitable for 415±10% V, 50Hz, 3 phase AC supply suitably designed for variable frequency drive applications, drain connections , stainless steel (18G) drain pahall be suitable for wall mount & capable of following features: (As per 350 sqm covered area) for Basement ventilation.ious ranges.xternal disconnect, external harmonic filters, additional external EMC Filters to comply with IEC61800: 3 (unrestricted distributi
Supply , installation testing and commissioning of Double skin floor mounted Horizontal/vertical Dx Coil (One coil) AHUs wherever required as per the mentioned in AHU schedule. (All AHU Should Be BMS/VFD Compitable)
Double Skin Ceiling Mounted Horizontal AHU With thermal break profile ,one inch nano wave lofted synthatic media Filter & ESP/EAC filter . The dust holding capacity of PM 10 shall be 190 grams and 150 grams for the 0.3 Micron .Two Pipe System (One Coils) ; 6-RD Dx Cooling Coil ,40 mmwg S.P. with three Phase Motor
2000 CFM/5.0 TR
2500 CFM/4.0 to 6.0 TR
3000 CFM/5.5 to 6.5 TR
3500 CFM/6.5 to 8.5 TR
4000 CFM/9.0 TR
4500 CFM/9.0 to 11.0 TR
5000 CFM/9.5 to 11.0 TR
Double Skin Floor Mounted Horizontal AHU With thermal break profile ,one inch nano wave lofted synthatic media Filter & ESP/EAC filter . The dust holding capacity of PM 10 shall be 190 grams and 150 grams for the 0.3 Micron .Two Pipe System (One Coils) ; 6-RD DX Cooling Coil ,50-55 mmwg S.P. with three Phase Motor
9000 CFM/21.0 TR
21000 CFM/65 TR
Floor Mounted Horizontal Air Handling Units With Exh. Blower and Enthalpy Recovery Wheel (FM AHU)
All AHU Should Be included Supply/Return/Fresh Air Damper & Thermal Break Profile and with three phase motor suitable for BMS Compitable
Double Skin Floor Mounted Horizontal/Vertical TFA With thermal break profile ,one inch nano wave lofted synthatic media Filter ESP/EAC & Fine filter. The dust holding capacity of PM 10 shall be 190 grams and 150 grams for the 0.3 Micron .Two Pipe System (One Coils) ; 8-RD DX Cooling Coil , 80 mmwg S.P. of Supply Air Fan and 60 mm wg SP of Exh. fan,Enthalpy Recovery Wheel , ,Mixing box and with three Phase Motor
16500 CFM Supply Fan/13500 CFM Exh. Fan/60 TR for TFA
Spcl. Note : If any AHU/TFA at terrace lvl. Than that will be with weather proof canopy so it should be cross check with dwgs. and at site accordingly pricing quoate .
CONDENSATE DRAIN PIPE
Supplying, fixing,testing and commissioning of following PVC pipes for condensate drain duly insulated with kinny foam & vapour barrier duly secured with adhesive tape as per specification ,cut to required length and installed with
65mm dia
50mm dia
40mm dia
30mm dia
25 mm dia
Propeller fan
Supply,installation,testing and commissioning of Certified Propeller fan of the following capacity of approved make and specification. Fan shall be supplied with aluminum gravity louver & bird screen and Speed Regulator.
150 mm dia propeller fan, with single phase motor
300 mm dia propeller fan, with single phase motor
450 mm dia propeller fan , with single phase motor
Inline fan
Supply, installation, testing and commissioning of Certified Circular/Rectangular swing type Inline fan with fiire retardent Canvas connection Speed Regulator of the following capacity of approved make and specification.
550-800 CFM, 10-12 mm SP WG with Single phase motor
850-1000 CFM, 12-15 mm SP WG with Single phase motor
1050-1300 CFM, 12-15 mm SP WG with Single phase motor
Tube Axial Flow fans
SITC of Long case Tube axial flow fans, as per specifications and approved makes suitable for three phase operation at 1450 RPM respectively Normal/Smoke case.
SITC of AMCA Certified (For Air and Sound Performance) tube axial flow fan of different capacity as mentioned below in standard M.S.contruction. Entire fan model & AMCA Seal shall apear in techncial submittal of fan. All the fans are synthetic enamelled panited/hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet. The electric motor coupler shall be squirrel cage induction motor (IE-3 type) confirming to IS - 325-IP - 55 with class `F' insulation. Fan efficiency should not be less than 70 %, noise level should not be more than 85 db @ 3 m distance when measured in hemisperical reverberant room conditions. Fans should be as per specification and drawings. (As per Vent. Fan Schedule ) (Pressurization Fans with St. Press. of 40 mmWG)
8000 CFM (For Stairwell/Liftwell/lobby Pressurization)
16000CFM (For Make Up Air)
13500-14500 CFM (For Stairwell/Lift well/lobby Pressurization)
37500CFM (For Make Up Air)
23500 CFM (For Stairwell/Lift well/lobby Pressurization)
34000-35500 CFM , 30 mmwg SP (For Make Up air Basements)
6000CFM (For Make Up Air)
SITC of AMCA Certified (For Air and Sound Performance) tube axial flow fan of different capacity as mentioned below in standard M.S.contruction. Entire fan model & AMCA Seal shall apear in techncial submittal of fan. All the fans are synthetic enamelled panited/hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet. The electric motor coupler shall be squirrel cage induction motor (IE-2 type) confirming to IS - 325-IP - 55 with class `H' insulation. Motor shall be of high temperature resistance "Class H Smoke Spill" 250° C for 2 hrs. Fan shall be EN 12101-3 Certified & CE/UL Listed for high temprature. Fan efficiency should not be less than 70 %, noise level should not be more than 80 db @ 3 m distance when measured in hemisperical reverberant room conditions for Normal mode Fans and noise level should not be more than 85 db @ 3 m distance when measured in hemisperical reverberant room conditions for Emergency mode Fans. Fans should be as per specification and drawings (As per Vent. Fan Schedule ).
6000 CFM, 30 mmwg SP For Normal & Smoke extract
37500 CFM, 30 mmwg SP For Normal & Smoke extract
30500 CFM, 30 mmwg SP For Normal & Smoke extract
34500-35500 CFM, 30 mmwg SP For Normal & Smoke extract
16000 CFM, 30 mmwg SP For Smoke extract
18000 CFM, 30 mmwg SP For Smoke extract
36000 CFM, 30 mmwg SP For Smoke extract
45000 CFM, 30 mmwg SP For Smoke extract
Evaporative air cooler(Air Washer)
Supply , Install, test and commission double skin Evaporative air washer as per specifications , suitable for the following capacity given below at 75-90% efficiency of evaporative medium. The fan shall be of DIDW centrifugal construction. Packaged Type
Ventilation fan sections of double skin construction as described above and in the specifications DIDW type,motor within the casing.All fans shall have multi speed motors Cost to be inclusive of unit isolator and .25HP-0.5HP water pump. Fan Motor VFD Compitable. AS PER SPEC.
2000 CFM, 3PH, 40 mm WG static pressure,960 rpm, 1.5HP motor with Speed controller for Ceiling/floor mounted
Air Scrubber (DRY Type)
DIDW FAN : Kitchen Exhaust
Supply, installation, testing and commissioning of DIDW Backword curved horizontal floor mounted fan unit comprising of accurately cut scroll & side plates, heavy gauge with all welded construction, sheet steel fabricated impeller, drive with blower pulley, motor pulley, V-belts, squirrel cage motor complete as per specification (fan- motor efficiency exceeding ASHRAE 90.1-2007 Criteria). (The bidder shall submit fan performance curves for all fans).
The item should be all complete in line with relevant standards, technical specifications of the standards and direction of engineer incharge.
2500 CFM / 75 mm WG SP
DRY SCRUBBER : Kitchen Exhaust
Supply, Installation, Testing and Commissioning of Dry Scrubber comprising of extract air intake section, electrostatic precipitation technology, dry type air cleaner to remove odour, smoke and fumes from exhaust air.
Electrostatic section shall be made of 16 gauge galvanised sheet,high bake epoxy powder coated, washable type aluminium mesh filters, stainless steel spiked ionizers to create high voltage DC field, Stainless Steel 316 collector plates which should be alternatively charged positive and negative with large collecting area with 14" deep cell, to work as magnet for charged smoke and oil particles. Average efficiency of 95% and more in single pass as per DOP test method. Electrostatic Precipitator should be able to charge particles from 0.01 micron to 10 microns through solid state power supply. The system should be fitted with interlock switch for safety. The system should allow connection to a fan section to achieve 500 FPM velocity across the air cleaner.
2500 CFM for Kitchen Exh.
Variable speed drives.
Supply of following HVAC dedicated VFDs with IP 55 enclosures with Mains disconnect, complying with the tender specifications and having: 1. built-in dual 5% impedance DC link reactor (harmonic filters) on the positive and negative rails of the DC bus of the VFD. 2. built-in EMC Filters (electromagnetic compatibility filters) for for VFDs for restriction of conducted emissions to comply with IEC61800: 3 (unrestricted distribution):2004 Category C 3, 3. Three-feedback PID controller having capability to simultaneously accept 3 feedback signals from temperature sensors or pressure sensors or CO2 sensors for process optimization and accordingly regulate the speed of the AHUs or pumps. 4. Provision for additional 3 PID controllers to control external devices such as chilled water modulating valve, fresh air damper, etc. thus reducing the number of I/Os in DDC Controllers & improving system reliability. 5. Automatic Energy Optimization / Load dependent flux optimization functionality for maximum energy savings. 6. MODBUS RTU as the communication protocol between BMS & VFDs. 7. VFDs not meeting above requirements shall provide external disconnect, external harmonic filters, additional external EMC Filters to comply with IEC61800: 3 (unrestricted distribution):2004 Category C 1 (50 m), external PLCs / DDCs to achieve 3 Feedback PID Controller functionality and external devices controlling capabilities.
Supply , Install, test and commission Variable Speed Drive package as described above and in specifications suitable for for 11.0 kW motor rating as per the specifications(3 Phase variable frequency output for Normal Vent. fan . These variable speed drives shall get the input from the remote air differential pressure adjuster , as described above in item.
Supply , Install, test and commission Variable Speed Drive package as described above and in specifications suitable for for 7.5 kW motor rating as per the specifications(3 Phase variable frequency output for Normal Vent. fan . These variable speed drives shall get the input from the remote air differential pressure adjuster , as described above in item.
Supply , Install, test and commission Variable Speed Drive package as described above and in specifications suitable for for 2.2-3.7 kW motor rating as per the specifications(3 Phase variable frequency output for Normal Vent. Fan , . These variable speed drives shall get the input from the remote air differential pressure adjuster , as described above in item.
CO SENSOR
Supply, installation, testing and commissioning of CO sensors . The car park ventilation systems shall be controlled by an individual CO-Monitoring system for entire car park located on each level to optimize efficiency. The contactors within the motor control panel shall be controlled by a Carbon Monoxide monitoring panel which shall contain DDCs (Direct Digital Controllers) where the pre-determined switching strategy and logic shall be loaded. The CO monitoring panel shall receive signals from CO sensors located throughout the levels at a spacing of no. more than 1 per 350 m2. The 24Vac power supply for the CO sensors shall be mounted in the same panel. The power supply shall be looped across the CO sensors. The proposed CO sensor shall provide a 0-10 VDC signal for measuring the CO level in the car park area. CO monitoring devices shall be mounted remotely throughout the car parks. The devices shall be mounted in accordance with the manufacturers guidelines but no greater than 1.5 m above FFL. CO Sensor shall be suitable for wall mount & capable of following features: (As per 350 sqm covered area) for Basement ventilation.
Digital display of the CO level : 0 to 200 ppm
Analog output : 4 to 20 mA / 0-10VDC
Low Voltage operation : 24 VAC / VDC
Test Switch : Provides mode for system self test.
Automatic Calibration (Field Calibration Kit)
Over-range indication.
Start-up mode : steps display and output through test ranges.
Solid – Stat sensor : Life expectancy of 7 to 10 years.
Multiple sensors with one power supply.
PHI Cell
Up to 1,200 CFM ,24 VAC, 0.47 amps, 11 watts ,5” probe, 5.5” dia. Plate
1,000 to 6,500 CFM ,24 VAC, 0.6 amps, 14 watts ,9” probe, 5.5” dia. Plate
9,000 to 18,000 CFM , 220 VAC 50/60 Hz , 0.14 amps, 20watts ,14” probe, 5.5” dia. Plate
AIR CURTAIN
Supply,installation testing and commissioning of AIR CURTAIN of following size as per approved make and with Door limit switch/sensor with multi speed regulator .(At ground entrance)
1800 mm long (High flow type)
2100 mm long (High flow type)
TOTAL CARRIED OVER TO SUMMARY (EQUIPMENT)
AIR SIDE WORKS
Site Fabricated Duct - GI duct
Supply,Installation,balancing and commissioning of fabricated at site GSS sheet metal ducts (rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter,vanes, hangers, supports etc.) in accordance with the approved shop drawings and specifications , and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces.
Spcl. Note: All Duct Supprots incl. Supply, Fabrication, installation and testing of Steel Wire Ropes and Hangers, Supports and Modular system – Wire rope Supports (double channel wedge lock, unlocking device should not be integral part of grip for added safety) complete with end fixing. Wire Hangers shall be independently tested by reputed third party testing organization to sustain safe working load for 120min at elevated temperature of 175 deg. C or above. System shall be in accordance with the approved shop drawings and as required by the specifications
0.63mm (24 gauge) GSS
0.8 mm (22 gauge) GSS
1.0mm (20 gauge) GSS
1.25mm (18 gauge) GSS
Factory Fabricated Duct - GI duct
Supply,Installation,balancing and commissioning of factory fabricated GSS sheet metal ducts (rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter,vanes, hangers, supportsetc.) in accordance with the approved shop drawings and specifications , and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces.
Spcl. Note: All Duct Supprots incl. Supply, Fabrication, installation and testing of Steel Wire Ropes and Hangers, Supports and Modular system – Wire rope Supports (double channel wedge lock, unlocking device should not be integral part of grip for added safety) complete with end fixing. Wire Hangers shall be independently tested by reputed third party testing organization to sustain safe working load for 120min at elevated temperature of 175 deg. C or above. System shall be in accordance with the approved shop drawings and as required by the specifications
0.63mm (24 gauge) GSS
0.8 mm (22 gauge) GSS
1.0mm (20 gauge) GSS
1.25mm (18 gauge) GSS
Supply, Fabrication, Installation and testing of Insulated Al. Flexible ducts in accordance with the approved shop floor drawings and specifications and shall also confirm to the BIS specifications.
150 mm Dia.
Grilles/Diffusers
Supplying and fixing of Extruded aluminium supply and return air grilles/diffusers/louvres with dampers, supply air plenum etc. duly powder coated as per specifications and drawings.
Aluminium supply air grilles with damper.
Aluminium return air grilles without damper.
Aluminium supply air square diffuser with damper
Aluminium return/exhaust air square diffuser without damper.
Aluminium return/exhaust air Valve circular/squirell diffuser without damper.
Linear air grilles (150 MM wide)
Aluminium supply air collar damper
Jet Diffusers (315mm Dia.)
AI Volume control dampers for ducts
Fresh Air/Exhaust Air Louvers
Supplying and fixing of extruded aluminium louvres with frame bird screeen , mounting arrangement etc. as per specifications and drawings.
Fresh Air/Exhaust Louvers
MOTORIZED FIRE AND SMOKE DAMPERS
Supplying, fixing, Testing and commissioning of fire dampers in suppy air duct/main branch and return air path as and where required of required size i/c control wiring ,the damper shall be motorized combination fire and smoke
Bare Fire Dampers with 400 mm sleeve
Control panel actuator , including Electrical,spring type actuator,remote indication of the fire damper position.
Interconnecting wiring for the fire alarm system with the AHU and the smoke dampers.
Sealing the openings around the sleeve of the fire dampers with approved fire sealant, as per the recommendations of the manufacturer and specifications.
Supply,Installation,Testing and commissioning of doble layer canvas connection (Fire retardent) as per specification.
Spcl. Note: In Air Distribution Works Smoke extract Duct should be fire rated for 2 hrs. So Vendor give their quoate accordingly.
TOTAL CARRIED TO SUMMARY (AIR SIDE WORKS)
MECHANICAL INSULATION
DUCT LINE ACOUSTIC TREATMENT
Supply and installation of cross linked open cell Oxide Acetate ( Acco Isolate) Foam/Nitrile Rubber Acoustic insulation on ducts having density of 30 to 60 Kg/ M³ ,having K value 0.029 W/m ° K at 0°C Deg temp and temp range of -70°C to +100°C and fire rating Class O as per BS 476 Part 6 from CBRI,Roorkee and CFC/HCFC free as per US EPA 5021 A(2014 ). • Smoke & Toxicity index of material shall be passed as per IMO MSC 307 ( 88 ) 2010 Anexx 1 Pt 2 and as per the approved specifications.
15mm thick Acoustic open cell insulation on one side for Duct acoustic insulation
DUCT LINE THERMAL INSULATION
Supply and installation of cross linked closed cell Oxide Acetate ( Thermo Isolate) Foam/Nitrile Rubber Thermal insulation on ducts having density 0f 30 ±3 Kg/ M³ ,having K value 0.029 W/m ° K at 0°C Deg temp and temp range of -70°C to +100°C and fire rating Class O as per BS 476 Part 6 from CBRI,Roorkee and CFC/HCFC free as per US EPA 5021 A(2014 ). • Smoke & Toxicity index of material shall be passed as per IMO MSC 307 ( 88 ) 2010 Anexx 1 Pt 2 and as per the approved specifications.
25 mm thick insulation with Two layer 7 mile cloths with adhesive on supply/Return/Exh. air duct on exposed area
13 mm thick insulation
9mm thick insulation
EXPOSED ROOF INSULATION
Supply and installation of cross linked closed cell Oxide Acetate ( Thermo Isolate) Foam/Nitrile Rubber Thermal insulation on ducts having density 0f 30 ±3 Kg/ M³ ,having K value 0.029 W/m ° K at 0°C Deg temp and temp range of -70°C to +100°C and fire rating Class O as per BS 476 Part 6 from CBRI,Roorkee and CFC/HCFC free as per US EPA 5021 A(2014 ). • Smoke & Toxicity index of material shall be passed as per IMO MSC 307 ( 88 ) 2010 Anexx 1 Pt 2 and as per the approved specifications.
19mm thick oxide acetate insulation for underceck plain
TOTAL CARRIED TO SUMMARY (Mechanical Insulation works)
ASSOCIATED ELECTRICAL WORKS
The rates for the distribution boards from the Breakers and instruments shall also include the following :
Wiring for light / Fan points with 1.5 sq. mm PVC insulated copper conductor 1100 Volt grade stranded flexible FRLS wires of approved make in 1.6 mm thick 25 mm dia MS conduit including cost of providing & fixing saddles, hangers, supports, cutting chases and filling chases for recessed conduiting, and including the cost of providing and fixing a 6 amp 240 Volt Modular Plate type switches of approved quality, colour, make and design with moulded cover plate in zinc chromate passivated MS box and including the cost of running 1.5 sq. mm PVC insulated copper earth wire for loop earthing etc. complete
TPN ACB’s / MCCB’s shall mean 3 pole ACB’s / MCCB’s with adequate size of neutral link.
All MCB’s shall be of minimum 10 KA breaking capacity and MCCB 's shall be not lessthan 25KA
The breaking capacity of MCCB’s are mentioned panel wise. All MCCB’s shall be with thermal magnetic microprocessor releases as per BOQ and following :
i. MCCB rating upto 250 Amps with thermal magnetic releases.
ii. MCCB above 250 Amps with microprocessor releases.
All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic.
Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993.
i. IP 42 for indoor panels.
ii. IP 55 for ODU panel.
All MCCB’s shall be provided with operating mechanism for door interlock.
All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire.
Providing cable clamps / supports within distribution boards cable alley.
Current density of aluminium shall be 1sq mm for 1.0 Amps for rated current of bus bars.
Model, current capacity location and frame size of switchgear shall be written inside of the panel doors with paint / permanent marker as approved shop drawings / site requirment.
All meter shall be digital type and all starter shall be as per Type-2 Coordination chart
Current Transfomer shall be resin cast.
All Panel Shall be BMS Compitable
Spcl. Note: All Panels, Cable tray,Power Cable etc. Supprots incl. Supply, Fabrication, installation and testing of Steel Wire Ropes and Hangers, Supports and Modular system – Wire rope Supports (double channel wedge lock, unlocking device should not be integral part of grip for added safety) complete with end fixing. Wire Hangers shall be independently tested by reputed third party testing organization to sustain safe working load for 120min at elevated temperature of 175 deg. C or above. System shall be in accordance with the approved shop drawings and as required by the specifications
Floor Mounted Panels with base frame (Min. 75 mm )
Plant/AHU/Fan Panel
Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of following LT panels fabricated out of 14 guage CRCA sheet steel in cubical formationwith reinforecment of suitable size angle iron and channel T iron flats. All steel material used in the construction of panels shall be powder coated. A solid busbar shall be provided at the bottom of the panel with two connecting eyes for termination. The boards shall be suitable for 415 volts, 50 Hz, 3 phase , 4 wire supply system. All the hardware used in the fabrication of the panel shall be galvanized with zinc passivation. The panel shall be compartmentalized to accommodate one feeder in each compartment. A vertcal cable alley of suitable width shall be provided to serve on or two vertical feeder sections. Also the opening between the busbar chamber and the feeder section shall be shrouded with bakelite / hylam sheet with min.3 mm thickness.
The panel drawing shall be approved before taking up the fabrication and compitable BMS if in future required.
In All panel Each starter should have remote control and interlocking facilities including auto manual switch, NO/NC contacts for control and must have auto manual operation suitable to take signal from fire alarm panel for automatic operation of fan in case of fire. All smoke /vent. fan panel the starters shall have suitable facility to operate with fire sensing control modules.
ODU's Panel-MCC-01 (Audi. Terrace)
Same as above item but outdoor Panel with following accessories.
INCOMING:
1 No. 630 amps, 415V TPN MCCB with overcurrent and short circuit releases, all indication, push button etc.
Coloured (Red, Yellow, Blue) phase indicating lamp - 1 set
BUSBAR:
800 Amp. TPN, 35 kA Al. Bus Bar
OUTGOINGS:
80A, TPN ELCB with 100mA - 13 Nos. (Incl. 1No. Spare)
40A, TPN ELCB with 100mA - 01 Nos. (Incl. 1No. Spare)
ODU Panel Described as above/As per Manufacturer ODU Configuration.
ODU's Panel-MCC-02 (Lower Wing Terrace)
Same as above item but outdoor Panel with following accessories.
INCOMING:
1 No. 1000 amps, 415V TPN MCCB with overcurrent and short circuit releases, all indication, push button etc.
Coloured (Red, Yellow, Blue) phase indicating lamp - 1 set
BUSBAR:
1200 Amp. TPN, 35 kA Al. Bus Bar
OUTGOINGS:
80A, TPN ELCB with 100mA - 18 Nos. (Incl. 1No. Spare)
40A, TPN ELCB with 100mA - 12 Nos. (Incl. 1No. Spare)
ODU Panel Described as above/As per Manufacturer ODU Configuration.
ODU's Panel-MCC-03 (Upper Wing Terrace)
Same as above item but outdoor Panel with following accessories.
INCOMING:
1 No. 800 amps, 415V TPN MCCB with overcurrent and short circuit releases, all indication, push button etc.
Coloured (Red, Yellow, Blue) phase indicating lamp - 1 set
BUSBAR:
1000 Amp. TPN, 35 kA Al. Bus Bar
OUTGOINGS:
80A, TPN ELCB with 100mA - 8 Nos. (Incl. 1No. Spare)
40A, TPN ELCB with 100mA - 18 Nos. (Incl. 1No. Spare)
ODU Panel Described as above/As per Manufacturer ODU Configuration.
Ventilation & Smoke Fan Panel
HVAC Fan Panel MCC-01 to 04, 6 to 9,12 (Base-03,Base-02,Base-1)
Incoming
1 no. 63 amp MCCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
100 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves.
Outgoings
1 nos. 20-25 A,TP MPCB (with VSD Space provision in panel , VSD item separate in boq) )
1 nos. 20-25 A,TP MPCB (with Star Delta starter )
Panel as described above and in drawings.
HVAC Fan Panel MCC-05 (Base-03)
Incoming
1 no. 50 amp MCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
80 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves.
Outgoings
1 nos. 6-10 A,TP MPCB (with VSD Space provision in panel , VSD item separate in boq) )
Panel as described above and in drawings.
HVAC Fan Panel MCC-10 (DG Vent. Base-02)
Incoming
1 no. 200 amp MCCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
250 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves.
Outgoings
4 nos. 25-40 A,TP MPCB (with Star Delta starter )
Panel as described above and in drawings.
HVAC Fan Panel MCC-11(Base-01)
Incoming
1 no. 63 amp MCCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
100 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves.
Outgoings
1 nos. 13-18 A,TP MPCB (with VSD Space provision in panel , VSD item separate in boq) )
1 nos. 13-18 A,TP MPCB (with Star Delta starter )
Panel as described above and in drawings.
HVAC Fan Panel MCC-13 (GF)
Incoming
1 no. 32 amp MCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
50 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves.
Outgoings
1 nos. 4-6.3 A,TP MPCB (with DOL starter )
1 nos. 2.5-4 A,TP MPCB (with DOL starter )
Panel as described above and in drawings.
HVAC Fan Panel MCC-14 (1st)
Incoming/Outgoing
1 nos. 13-18 A,TP MPCB (with DOL starter )
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Panel as described above and in drawings.
HVAC Fan Panel MCC-15 (2nd Terrace)
Incoming
1 no. 63 amp MCCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
100 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves.
Outgoings
2 nos. 13-18 A,TP MPCB (with DOL starter )
Panel as described above and in drawings.
HVAC Fan Panel MCC-16 (2nd Terrace)
Incoming
1 no. 80 amp MCCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
100 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves.
Outgoings
2 nos. 25-40 A,TP MPCB (with Star Delta starter )
Panel as described above and in drawings.
HVAC Fan Panel MCC-17 (9th Terrace)
Incoming
1 no. 63 amp MCCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
100 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves.
Outgoings
2 nos. 9-14 A,TP MPCB (with DOL starter )
The base frame shall be 75 mm x 5 mm.
Panel as described above and in drawings.
HVAC Fan Panel MCC-18 (Terrace)
Incoming
1 no. 250 amp MCCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
300 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves.
Outgoings
1 nos. 25-40 A,TP MPCB (with Star Delta starter )
9 nos. 9-14 A,TP MPCB (with DOL starter )
2 nos. 13-18 A,TP MPCB (with DOL starter )
The base frame shall be 75 mm x 5 mm.
Panel as described above and in drawings.
HVAC Fan Panel MCC-19 (Terrace)
Incoming
1 no. 100 amp MCCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
125 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves.
Outgoings
3 nos. 9-14 A,TP MPCB (with DOL starter )
1 nos. 25-40 A,TP MPCB (with Star Delta starter )
The base frame shall be 75 mm x 5 mm.
Panel as described above and in drawings.
Air-conditioning AHU Fan Panel
HVAC AHU Panel MCC-01 (GF)
Incoming/Outgoing
1 nos. 2.5-4 A,TP MPCB (To AHU Blower VSD, VSD With AHU or AHU with VFD Plug fan )
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Panel as described above and in drawings.
HVAC AHU Panel MCC-02 (GF)
Incoming/Outgoing
1 nos. 4-6.3 A,TP MPCB (To AHU Blower VSD, VSD With AHU or AHU with VFD Plug fan )
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Panel as described above and in drawings.
HVAC AHU Panel MCC-03,4 (GF)
Incoming
1 no. 50 amp MCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
80 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves.
Outgoings
5 nos. 2.5-4 A,TP MPCB (To AHU Blower VSD, VSD With AHU or AHU with VFD Plug fan )
The base frame shall be 75 mm x 5 mm.
Panel as described above and in drawings.
HVAC AHU Panel MCC-05,7 (1st)
Incoming
1 no. 32 amp MCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
50 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves.
Outgoings
2 nos. 2.5-4 A,TP MPCB (To AHU Blower VSD, VSD With AHU or AHU with VFD Plug fan )
2 nos. 4-6.3 A,TP MPCB (To AHU Blower VSD, VSD With AHU or AHU with VFD Plug fan )
The base frame shall be 75 mm x 5 mm.
Panel as described above and in drawings.
HVAC AHU Panel MCC-06 (1st)
Incoming
1 no. 20 amp MCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
32 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves.
Outgoings
1 nos. 2.5-4 A,TP MPCB (To AHU Blower VSD, VSD With AHU or AHU with VFD Plug fan )
1 nos. 4-6.3 A,TP MPCB (To AHU Blower VSD, VSD With AHU or AHU with VFD Plug fan )
Panel as described above and in drawings.
HVAC AHU Panel MCC-08,10, 13 to 17 (2nd,3rd,4th,5th)
Incoming
1 no. 20 amp MCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
32 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves.
Outgoings
2 nos. 2.5-4 A,TP MPCB (To AHU Blower VSD, VSD With AHU or AHU with VFD Plug fan )
Panel as described above and in drawings.
HVAC AHU Panel MCC-9,19,21 (2nd,6th,7th)
1 no. 20 amp MCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
32 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves.
Outgoings
2 nos. 4-6.3 A,TP MPCB (To AHU Blower VSD, VSD With AHU or AHU with VFD Plug fan )
Panel as described above and in drawings.
HVAC AHU Panel MCC-11 (2nd Terrace)
1 no. 63 amp MCCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
100 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves.
Outgoings
1 nos. 6-10 A,TP MPCB (To AHU Blower VSD, VSD With AHU or AHU with VFD Plug fan )
1 nos. 20-25 A,TP MPCB (To AHU Blower VSD, VSD With AHU or AHU with VFD Plug fan )
The base frame shall be 75 mm x 5 mm.
Panel as described above and in drawings.
HVAC AHU Panel MCC-12, 18,20,22,23,24 (3rd,6th,7th,8th,9th)
Incoming
1 no. 32 amp MCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
50 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves.
Outgoings
4 nos. 2.5-4 A,TP MPCB (To AHU Blower VSD, VSD With AHU or AHU with VFD Plug fan )
The base frame shall be 75 mm x 5 mm.
Panel as described above and in drawings.
HVAC AHU Panel MCC-25 (10th)
Incoming
1 no. 32 amp MCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
50 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves.
Outgoings
2 nos. 2.5-4 A,TP MPCB (To AHU Blower VSD, VSD With AHU or AHU with VFD Plug fan )
1 nos. 4-6.3 A,TP MPCB (To AHU Blower VSD, VSD With AHU or AHU with VFD Plug fan )
The base frame shall be 75 mm x 5 mm.
Panel as described above and in drawings.
CABLING (POWER )
Power Cabling and Earthing:
Supply, installation, testing & commisioning of Aluminum conductor cables PVC sheathed, armoured cables of 1.1 KV grade with termination glands , identification tags, clamps and saddles etc.
3Cx10 Sqmm
3Cx35 Sqmm
3Cx25 Sqmm
3Cx16 Sqmm
3Cx 06 Sqmm
3Cx04 Sqmm
2Cx04 Sqmm (Cu Conductor)
4Cx06 Sqmm
4Cx04 Sqmm
Control Cabling
Supply, installation, testing & commisioning of Copper conductor , PVC insulated, PVC sheathed armoured cable of 1.1 KV grade (Which is Interconnecting wiring for the fire alarm system with the AHU and the smoke dampers and AHU to Panel).
8C x 1.5 Sqmm
3C x .5 Sqmm
2C x .5 Sqmm
Supplying and making outdoor end termination of cable termination of above cables with Al./copper lugs & flameproof brass compression glands on both the ends with inhibting compound etc. complete as required.
3Cx10 Sqmm
3Cx35 Sqmm
3Cx25 Sqmm
3Cx16 Sqmm
3Cx 06 Sqmm
3Cx04 Sqmm
2Cx04 Sqmm (Cu Conductor)
4Cx06 Sqmm
4Cx04 Sqmm
Supplying and installing following size of perforated Hot dipped G.I. cable trays, G.I. bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with suitable suspenders above in general points complete as required.
100 mm. Width x 50mm. Depth x 1.6mm. Thickness.
150 mm. Width x 50mm. Depth x 1.6mm. Thickness.
225 mm. Width x 50mm. Depth x 1.6mm. Thickness.
300 mm. Width x 50mm. Depth x 1.6mm. Thickness.
450 mm. Width x 50mm. Depth x 1.6mm. Thickness.
Supplying and Laying following size of G.I. strip / G.I. wire on surface or in recess for loop earthing alongwith the existing surface/ recessed conduit/ submain wiring / on cable tray/ on surface including G.I. clamps etc. complete as required.
6 SWG G.I. wire
TOTAL CARRIED TO SUMMARY (HVAC Electrical Works)
BUILDING MANAGEMENT SYSTEM
Spcl. Note: IBMS system will be sepearte as per config.
Central Control Station for BAS System
SITC of Central Work Station Client with Intel i8 processor with minimum 640GB HDD,4 GB RAM, 21" TFT Monitor, DVD Writer,infrared mouse; Work station must have minimum Windows 7 or Windows 10 as Operating System.Windows Licensed software compatible with the BMS platformwith Database,OS with lifetime license.
600 dpi or better A4 size Lazer Printer for printing reports ,Alarms data etc
SOFTWARES / SERVER / ROUTER
SITC of Web Based BMS Software along with Dedicated Server supporting BACNET/MODBUS/LONtalk protocol as specified with all monitoring/control modules including but not limited to full function Report / Trending / Alarm. Software shall have Customizable Graphics and site pecifics graphics/Navigations shall be prepared. Software shall be loaded on Dedicated Server (Not on Client PC). Dedicated Server shall be Linux based to avoid all Windows based Viruses. Dedicated Server shall have minimum 72 Hours of Battery backup
Client Licenses for 5 Client Operator Work Stations
SITC of BTL Approved BACnet Router/ System Core Server for Connecting all DDC Controllers to BMS Software. It shall have Minimum 32 Bit Processor , Minimum 128 MB SDRAM , Minimum 128 MB Compact Flash Memory and 72 Hours of Battery Backup
Integrators for Software Integration with following systems
Supply, Installation, Testing & Commissioning the following equipment for BMS system
Integrators for Aircooled VRV/VRF System (21 Ckt)
Integrators for AHU with Plug Fan (VFDs) (11 Nos.)
Integrators for Fans (10 Nos.)
Integrators for Lighting or Automation system
Integrators for DG
Integrators for HT/LT Panel
Integrators for Lift
Integrators for Solar System
Integrators for Plumbing System
DDC Controllers & Enclosures
SITC of Microprocesser based Stand Alone DDC Controller with required IO Capacity as per IO Summary and housed in IP 55 MS powder coated panel duly internally wired with power supply for Sensors and othe field devices.DDC Controller must be 230 VAC Powered with DIN Rail Mounting and must have provision to add IO Points and Display in Future.
DDC for Air-cooled VRV/VRF System (21 Nos.)
DDC for Floor Mounted Air Handling Units (11 Nos.)
DDC for Automation (Lighting) System (8Nos.)
DDC for Air Washer/Scrubber/fan (1 No.)
DDC for exhaust fan (1 Nos.)
DDC for Pressurization fan (2 Nos.)
DDC for DG System (3 Nos.)
DDC for HT/LT Panel (6 Nos.)
DDC for Lift System (2Nos.)
DDC for PHE System (3 Nos.)
Field Devices
Supply, installation, testing & commissioning of the following Sensors : (Spcl. Note If any item considered in above or HVAC BOQ then that’s not repeated here)
Diff. Pressure Sensors
Water Level Switch
Immersion Temp Sensor
Duct Temp. & Humidity Sensors
Room Temp & RH Sensor
Air DP Switch
Cable, Conduit and Cable Tray
Supply, Installation, Testing & Commissioning of the following cables conduit and cable tray as per the specifications:
2C Twisted Pair x 1.5 Sqmm Communication Cable-Flexible
2C x 1.5 Sq mm unscreened Flexible Cable
4C x 1.5 Sq mm Screened Flexible Cable
6C x 1.5 Sq mm Screened Flexible Cable
8C x 1.5 Sq mm unscreened Flexible Cable
25 mm PVC Conduit for above Cables
200 mm x 50 mm x 2 mm Aluminimum Trunck
100 mm x 20 mm x 2 mm Perforated Cable Tray
FIRE PUMPS - ELECTRICAL
Supply, installation, testing and commissioning of horizontal single stage centrifugal type factory assembled fire pumps suitable for autometic operation at synchoronous speed of 2900 rpm, TEFC conforming to IP-55 & flexible coupling gaurd mounted on a common structural base plate with 150mm dia gun metal pressure gauges with isolation cock and piping, suitable vibration elimination pads of approved design for pump foundation, motor to be suitable for 415 volts, 3 phase 50 cycles AC.
Capacity 2850 LPM at 9.0 Kg/cm2 delivery pressure for Fire Hydrant Network.
Capacity 180 LPM at 9.0 Kg/cm2 (Jockey Pump).
Capacity 2280 LPM at 6.0 Kg/cm2 delivery pressure for Fire Hydrant Network.
FIRE PUMPS - DIESEL
Supply, installation, testing and commissioning of horizontal single stage centrifugal pumping set with CI volute and bronze impeller with mechanical seals directly coupled to automatic Diesel Engine complete with all accessories like self starting by means of Battery powered electric starter motor, Paper Filter type air cleaner, exhaust silencer etc. complete in all respects. The engine & the pump will be mounted on common base plate on anti-vibration mountings.
Capacity 2850 LPM at 9.0 Kg/cm2 delivery pressure for Fire Hydrant & Sprinkler Network.
Exhaust piping
Providing & fixing 150 mm diameter M.S. Class 'C' diesel pump exhaust pipe includings all fittings, like bends, tees etc. clamps / structural steel supports. The pipe shall be provided with 75mm thick fiberglass insulation & covering the insulation with 500 g polythene sheet giving proper overlaps & sealing the joints with suitable adhesive compound. The pipe shall be provided with 24 gauge aluminium sheet cladding
PRESSURE SWITCH
Supplying, installing, testing and commissioning 0 to 12 Kg/ cm2 ON/OFF pressure switch in delivery line of pump along with control wiring for auto starting and auto stopping of hydrant and jockey pumps.
Supply, fabrication (as per code), installation, testing and commissioning of Air vessels 250mm diameter and 1200mm high fabricated from 8mm M.S. plate with accessories inside painting with epoxy paint and outside with enamel.
Providing, fixing, testing & commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 8.8 Kg/cm2 and test pressure 14 Kg/cm2 for :-
150 mm dia
100 mm dia
80 mm dia
Supply, installation, testing, trial run and commissioning of hydrants all complete as required and as approved
Fire Hose Cabinet
Providing and fixing angle iron (40 mm x 40 mm x 5 mm) MS door frame 900x2100 door capable of accommodating fire hose reel, landing valve, hose pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for making 900x600x2100 Recessed type mansoary box (by civil contractor).
Providing and fixing of TAC approved 1.6mm thick M.S. fire hose cabinet (750x600x250mm) made out of 16 gauge M.S. sheet capable of accommodating landing valve, hose pipes, fittings & accessories. The box shall have a front glass door with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) - for external and roof hydrant.
Providing and fixing of 63mm dia single outlet GM landing valve IS marked with suitable size bolts, nuts, washers and gaskets. Landing valve shall be TAC Approved Make.
Providing and fixing of 63mm dia twin outlet GM landing valve IS marked with suitable size bolts, nuts, washers and gaskets. Landing valve shall be TAC Approved Make.
Providing and fixing of First aid hose reel with 25 mm dia, 30 m long rubber hose, ball valve, piping and GM nozzle
Providing and fixing of 63mm reinforced rubber hoses (RRL) with male and female GM coupling, IS marked- 15 m long
Providing and fixing of standard short size GM branch pipe with nozzle of 20mm nomnal bor outlet with instaneous type 63 mm dia coupling complete IS marked & TAC approved.
Fire Axe
Providing and fixing of ss orifice plates in pipelines to reduce pressure from 8 kg. to 3.5 kg/sq.cm.
Providing, installing, testing & commisioning of fire brigade inlet connection (fire department connection) consisting of 4 Nos. 63 mm dia instantaneous inlet arranged on a 50 mm dia header, 1 No. 150 mm diameter Butterfly valve, 1 No. 150mm dia. Non-return valve and wall mounted box of M.S. construction with glass door to house the above mentioned components.
Providing, installing, testing & commisioning of fire brigade draw out connection (fire department connection) with suction pipe MS class 'C' 100 mm dia. & 100 mm dia. foot valve & steel chain including wall mounted box M.S. construction with glass door to house the above mentioned componenets.
TOTAL C/F TO SUMMARY
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
All kinds of soil
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.
Providing and fixing up to floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc. including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 Cement : 3 fine sand) on exposed surfaces complete.
1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
Constructing masonary chamber 90 x 90 x100 cm. inside with 75 class designation brickwork in cement mortar 1:5 ( 1 cement : 5 fine sand) for sluice valve with CI surface box 100 mm top dia. 180 mm bottom dia. And 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1 :5 :10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size and inside plastering with 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design with FPS bricks
Providing and fixing C.I. double acting air valves of approved quality with bolts, nuts, rubber insertions etc. complete ( The tail pieces, tapers etc. if reqd. will be paid separately)
50 mm dia.
Providing & Fixing C.I.sluice valve(with cap) complete with bolts,nuts,rubber insertions etc.(the tail pieces if required will be paid separately)
150 mm dia.pipe
Class II
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.
150 mm dia.
NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as
80 mm dia
100 mm dia
150 mm dia
BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified.
80 mm dia
100 mm dia
150 mm dia
200 mm dia
Providing and fixing in position the industrial type Pressure Gauges with gun metal / brass valves complete as required
TOTAL C/F TO SUMMARY
Providing laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 1239/3589 (all pipes shall be ISI marked and of makes specified in the specifications) including DI FORGED fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including excavation & providing cement concrete blocks as supports and anti- corrosive treatment to burried pipes by wrapping & coating with 4 mm thk. (OR 2 COATS of 4.0mm thick tape) anticorrosion tape along with two coat of black japan primer for under-ground pipe .
150 nominal bore (class C)
100 nominal bore (class C)
Providing, fixing, jointing and testing of (Class-C/Heavy duty) MS Pipe IS:1239 / 3589 marked, with accessories like tees, elbows, flanged joints, reducers, compressed asbestos gaskets, nuts and bolts including using modular pipe support. complete as required for delivery/suction manifold relating to the pumps including painting of two coats of Red Oxide including all civil breakages and making good the same. The rate includes the cost of installing DI threaded fittings UL listed & FM approved for pipe sizes upto 50mm dia and grooved fittings UL listed & FM approved listed for jointing pipe sizes above 50mm dia. No welding is to be done anywhere in the fire fighting system. All work is to be carried out as per the specifications
The support channel should be made up of cold rolled steel of quality DX51 or greater. The Support channel should be pre-galvanised with minimum GSM of 275 and should have universal mounting slot on the front of the rail for accurate positioning of fasteners and system compatible round and long holes on back of the rail the pipe.
The pipe clamps should be split type with EPDM inner rubber lining, FM/UL approved.
Threaded rod should be of 4.8 stregth class and necessary accessories should be of 8.8 strength class.
DI Threaded Fittings for pipe size upto 50mm dia:
Grooved Fittings for pipe sizes above 50mm dia:
250 mm nominal bore (class C)
200 mm nominal bore (class C)
150 mm nominal bore (class C)
100 mm nominal bore (class C)
80 mm nominal bore (class C)
65 mm nominal bore (class C)
50 mm nominal bore (class C)
40 mm nominal bore (class C)
32 mm nominal bore (class C)
25 mm nominal bore (class C)
Supply, installation, testing and commissioning of 150 mm dia Installation Control Valve inclusive of 2 nos 150 mm dia Butterfly Valve, strainer, Alarm Valve with Water Motor Gong, Pressure Gauges, Test Lines with Ball Valves with necessary GI (H) piping with threaded fittings of required sizes complete
Supply, installation, testing and commissioning of 150 mm dia Zonal Control Valve inclusive of 1 nos 150 mm dia butterfly valve, 150mm diam. non return valve, Flow Switch, water pressure gauges & 25 mm dia. Auxillary Drain valve with sight glass with necessary GI (H) piping with threaded fittings of required sizes complete
150 mm dia butterfly valve
150mm diam. non return valve
Flow switches in 150 mm. dia M.S. Pipe
pressure gauges
Pressure gauges in the M.S. Pipe Line including connection etc. as required.
25 mm dia. Auxillary Drain valve
Sight glass
100 mm dia butterfly valve
100mm diam. non return valve
Flow switches in 100 mm. dia M.S. Pipe
pressure gauges
Pressure gauges in the M.S. Pipe Line including connection etc. as required.
25 mm dia. Auxillary Drain valve
Sight glass
Providing, fixing, testing and commissioning of quick response 15 mm dia. gunmetal quartz bulb type sprinkler head to operate at 68 degree centigrade
Side wall type
Pendent /Upright type
Providing and fixing 25 mm dia, 1200mm long flexible stainless steel (SS 304) pipe for making final connection of sprinkler head with sprinkler system piping network including 2 nos. 25mm diameter G.I. connector, G.I. Nipple, Reducer, elbow and threaded jointing complete as per detail.
Supply, installation testing & commissioning Foot Valve lift type as per specifications to the satisfaction of Project-in-charge
TOTAL C/F TO SUMMARY
WATER CURTAIN SYSTEM (NON SCHEDULED ITEMS)
Note: Before commecing work the contractor shall be submit working drawings to the consulting engineer for approval.
Supply, installation, testing and commissioning single interlock delgue valve operated through flow switch including air compressor and panel, soleniod valve, check valve , gate valve, wiring, conduting etc. complete for automatic operation of water curtain in upper and lower basement.
Supply, installation, testing and commissioning high pressure resistance nozzle for water curtain in lower and upper basement area.
Supply, fabrication & laying heavy grade IS marked galvanized steel piping complete with all galvanized fittings, pipe supports, clamps, painting etc. as approved with threaded jointing for Pre -action sprinkler system.
150 mm nominal bore
100 mm nominal bore
25 mm nominal bore
TOTAL C/F TO SUMMARY
Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S. cylindrical body, internal discharge tube, discharge nozzle, suspension bracket, conforming to IS 15683, finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.
Capacity 4.5 kg
Providing and fixing (ABC Dry Chemical Powder ) type Fire Extinguisher of Capacity 6 kg Confirms to IS 15683, bearing ISI mark complete with brass forged squeeze grip type valve fitted with pressure gauge , pressurize with dry Nitrogen gas filled, with discharge nozzle with wall mounting bracket complete with internal charges.
Capacity 6 Kg.
Providing and fixing mechanical foam type Trolley Mounted Fire Extinguisher of bearing to IS:10568/IS13385/IS13386 with dis
Capacity 45 Lit.
Providing and fixing Carbon Dioxide Type Trolley Mounted Fire Extinguisher of as per IS: 2878 with discharge time of 10 to 20 sec/15 to 36sec/20 to 60sec respectively.
22.5 Kg. CO2 Fire Extinguisher
TOTAL C/F TO SUMMARY
Fabricating, supplying, testing and commissioning of electrical control panel of cubicle construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentallised and hinged lockable doors, dust and vermin proof, powder coated approved shade after 7 tank treatment process, cable alley interconnection, having switchgears and accessories mounting and internal wiring, earth terminals, numbering etc., complete in all respects, suitable for operation on 415V, 3 phase 50 Hz., AC supplywith enclosure protection class IP-42as required.
COMMON PANEL IN FIRE PUMP HOUSE.
INCOMER
400 Amps. TP & N SFU with HRC fuses.
Set of 3 phase indicating lamp.
Set of Al. bus bar 200 Amps.
OUTGOING.
Main fire pump and Sprinkler pump
Jockey pump
Diesel Engine Control
Control for Diesel Engine comprising:-
Indication lamp for High / Low Lub. Oil pressure, High Water Temp. and Engine ON indication.
All standard relays and acessories for automatic operation of diesel engine.
DIESEL ENGINE CONTROL
Control for Diesel Engine comprising:-
Indication lamp for High / Low Lub. Oil pressure, High Water Temp. and Engine ON indication.
MAIN FIRE PUMP CONTROL
200 Amps. TP&N SFU with HRC fuses
Set of 3 phase indication lamp.
Suitable HP fully automatic Star / Delta Starter with over load protection, current sensing type single phase preventor complete with all acessories and internal wiring required for automatic operation.
SYSTEM CONTROLLER
Designing, Supply, Installation, Testing and Commissioning of system controller to control operation of Main Electric Fire Pump, Diesel Pump, Pressurisation Pump, Terrace Pump in sequence as per specification consisting of relays, timets, sensors, annunciation window for fault indication, complete as per specification.
TOTAL C/F TO SUMMARY
Supplying and Earthing with GI earth plate 600mm x 600 mm x 6mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc, with charcoal/ coke and salt as required.
Supplying and laying 25 mm x 5 mm. G.I. strip in 40 mm dia. G.I. Pipe from earth electrode, including connection with GI nut, bolt, spring, washer excavation and re-filling etc as required.
Providing & fixing 25mm x 5mm G.I. strip on surface or in recess for connections etc. as required.
Providing and Fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing alongwith existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying, fabricating and installing following size of perforated painted with powder coating M.S. cable trays,with perforation not more than 17.5%, in covenient section, joined with connectors, suspended from the ceiling with MS suspenders including bolts & nuts, painting suspenders etc. as required.
100 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Laying and fixing of One number PVC Insulated and PVC Sheathed/XLPE power cable of 1.1 kV grade of size not exceeding 35 sqmm on surface as required.
Laying and fixing of One number PVC Insulated and PVC Sheathed/XLPE power cable of 1.1 kV grade of folloing size on wall surface as required.
Aboved 35 sq mm and upto 95 sq mm (clamed with 25x3mm MS flat clam)
Supplying of all materials and making terminations of 1.1 KV grade aluminium multicore cables of the following sizes. The work includes cable glanding using brass plated double compression glands, sizing the core leads, removing insulation, fixing suitable crimping type copper lugs/ thimbles by using hydraulic crimping tools with correct size of the dies, shaping the leads and neatly connecting the same to the equipment terminals.
3.5 Core 120 sq. mm. Armoured Aluminium cable.
3.5 Core 35 sq. mm. Armoured Aluminium cable.
3.5 Core 16 sq. mm. Armoured Aluminium cable.
Control Cabling (PVC insulated and PVC sheathed, armoured, Copper Conductor of 1.1 KV grade on existing cable trays).
5C x 1.5 Sq. mm
HORTICULTURE WORKS
Providing/ fixing MS trellis on roof top / terraces as per design of 3.0 m height with complete hardware, fabrication, hoisting and erection , painting with I cst quality enamel paint at all levels
Providing & fixing precast concrete reinforced chair type Benches as per item No.23 approved DNIT (N.S)
Construction of raised planters with black granite ledge and wall cladding (surface area of perimeter face to be measured
Providing Accent lights for plantation includin (skipes), wall recessed lights, in planters, uplighters , refelcetors alongwith wiring , commissionong and necessary hardware
Providing and fixing pavilions with traditional Red Roof Tiles on MS tubular structure and steel posts with CC flooring of size 3.6m x 3.6 m as per plan shape and height 2.7m with pendent LED lights 32 W
Supply and plantation of trees as per description below including diggging ofpits,plantation of plants ,mixing of gobar manure, and DAP mamure, antitermite, refilling, watering, and maintn. For 3-months Complete as per Specification (Plant must be healthy and well grown, height minimum 3.0 m with 20 cm girth (NS)
06 Butea monosperma PALASH Orange flower
07 Callistemon citrinus BOLLE BRUSH Red
08 Cassia fistula AMALTASH Yellow flower
13 Grevillea robusta SILVER OAK
23 Plumeria alba White flower
31Alstonia Scholarisis tree
35 Delonix Regia Gulmohar
Supply and Plantation of Shrubs Height 1 m minimum Supplied in unit packs and plantation in complete, digging,manuring , watering, pruning, dressing with maintenance for 3 months (NS)
01 Allamanda nerifolia BUSH ALLAMANDA
02 Caesalpinia pulcherrima PEACOCK FLOWER
03 Calliandra brevipes PINK POWDEPUFF
05 Cestrum nocturnum NIGHT JASMINE
10 Hibiscus rosa - sinensis CHINA ROSE
11 Ixora sps IXORA / RKMANI
12 Jasminum grandiflorum CHAMELI / JUHI / MALTI
19 Laltana camara LALTANA
20 Laltana montevidensis TRAILING LALTANA
21 Murraya paniculata ORANGE JASMINE
22 Poinsettia pulcherrima POINSETTIA
25 Tecoma stans TECOMA
Supply and planting of Accent trees as per description below including diggging ofpits,plantation of plants ,mixing of gobar manure, and DAP mamure, antitermite, refilling, watering, and maintenance . For 3-months Complete as per Specification (Plant must be healthy and well grown, height minimum 3.6 m or specified as under with 20 cm girth (NS)
Bootle Palm
Fish Tail Palm
Furcaria
Phoenix Palm
Cycus palm 1.5 m high
Traveller palm 1.5 m high
Washingtonia Palm
Ficus benjamin
Ficus panda
Topiary of Univurs
Topiary of Carijuna
Supply of Hedges and Edge Plants (N.S) as per details. Plant must be healthy and well grown, height between 0.8 m to 1.2 m
01Croton 100
03 Clerodedron inerme
04 Tabernae montana 100
06 Bauhinia acuminata 100
07 Murraya ( Kamini ) 120
10 Golden Duranta
Supply and plantation of Ground cover (N.S) as per details, inclusive of watering, pruning, maintaining for 3 months
01 Lantana slowianan
02 Golden Duranta
03 C- Inermi
04 Irisene
05 Verbina
06 Alternenthera
Supply and plantation of Creepers and climbers (N.S) as per details, inclusive of hooks, anchors , support frame reqd if any, watering, pruning, maintaining for 3 months
01 Allamanda blanchetii ALLAMANDA
04 Antigonum leptopus LOVE VINE
06 Bougainvillea sps BOUGAINVILLEA MULTI
07 Ipomoea campanulata SPOTTED HEART
Providing potted plants for indoors in planters with base cover (areca palm, moneyplant, song of india, ferns , palm plants including fibre pots
Providing Seasonal Flower seasonal flowers , Roses, poppy , euphoria and prennials such as sweet peas, Hollyhock, Chrysanthemum , Calendula, Aster, Verbena, Xenia, in flower beds both during winters and summers throughout the year (coverage area 75 % of flowering bed) as per approval of architect/ Engineer in incharge
Bidder Name
Amount
GORA LAL BUILDER AND ENGINEER(GSTN-06AAVPG3228R1Z1)
vasu construction co.(GSTN-06AAQFV6337D1ZX)
KASHYAPI INFRASTRUCTURE PRIVATE LIMITED(GSTN-09AADCK3785A3ZJ)
Shivalaya Construction Co. Pvt. ltd(GSTN-06AACCS2475A2ZQ)
vasu construction co.
Shivalaya Construction Co. Pvt. ltd
KASHYAPI INFRASTRUCTURE PRIVATE LIMITED
Shivalaya Construction Co. Pvt. ltd
GORA LAL BUILDER AND ENGINEER
KASHYAPI INFRASTRUCTURE PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid