Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.4 LAccepted-AOC VILLAGE DUMERKHA KALAN POST OFFICE DUMERKHA KALAN TEHSIL UCHANA DISTRICT JIND 126115 HARYANA | DUMERKHA KALAN | JIND | HARYANA | 126115 | 1 | Accepted-AOC AOC | |
| 2 | 2₹22.1 L+₹57,524 (2.68%)Rejected-Finance PLOT NO 172 22 GALI NO 09 GANDHI NAGAR GURGAON 122001 | GURGAON | GURUGRAM | HARYANA | 122001 | 2 | Rejected-Finance 2 |
Tender Value
₹21.1 L
EMD Value
₹42,210
Closing Date
28 Oct 2024, 12:00 pmClosed
PARVEEN KUMAR
Municipal Corporation Gurgaon
Repairing and Servicing of Transformer and shifting of Street Light poles in Various locations in Zone 3 and 4 under limit of Municipal Corporation Gurugram.
2024_HRY_405718_1
2024166378A8 F9C4 498E A46F 8DDE5DDD7BC7285ULB
Open Tender
Civil Works
Works
400 days
Gurugram
Repairing and Servicing of Transformer and shifting of Street Light poles in Various locations in Zone 3 and 4 under limit of Municipal Corporation Gurugram.
2 documents required · 2 mandatory
₹1,000
Yes
₹42,210
Yes
4 Nov 2024
21 Oct 2024
28 Oct 2024
21 Oct 2024
28 Oct 2024
21 Oct 2024
Amount
Repairing and Servicing of Transformer and shifting of Street Light poles in Various locations in Zone 3 and 4 under limit of Municipal Corporation Gurugram.
Dehydration and filtration of dirty transformer oil for transformer with dehydration filter machine.
Bushing of required size and design to be used on the primary side of the transformer.
S/E of XLPE (E)11 KV LT 240 Sq. mm 3 Core PVC aluminum conductor un-armoured cable ISI mark laid in existing pipe /trenches/surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. Make- Polycab, Havells, RR, Grandly
Supply and topping of 200 KVA and 315 KVA transformer Silicone Transformer Oil - High Dielectric Strength Fluid in conservator tank and including replacement of dirty silica gel in transformers.
Bushings of required size /design to be used on the secondary side of the transformer
Oil Drain valve, Filter valve and Dial type thermometer of appropriate design with max. Temp. Indicator complete with re-setting device and alarm contractor for transformer 100,63 KVA etc. with complete all respect.
Oil Drain valve, Filter valve and Dial type thermometer of appropriate design with max. Temp. Indicator complete with re-setting device and alarm contractor for transformer 100, 63 KVA etc. with complete all respect.
Gas cutting of lit of sealed type transformer of required specification and size as per design of the transformer with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work
HT tapex type cable boxes of required specification and size as per design of the transformer.
Loading and unloading of transformer at both side, hiring of crane, and transportation charges to and fro, Supervision and commissioning charges.
Repairing of 11 kv high tension CT and PT meter panel with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work.
S/E of XLPE (E)11 KV HT 95sqmm 3 core aluminum PVC conductor armoured cable ISI mark laid in existing pipe /trenches/surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. Make- Polycab, Havells, RR, Grandly
Tapping connections, insulation on tap leads, brazing by silver brazing rod, dressing of tap leads with insulation paper, Star/ Star connection by new EC grade Copper on HV and LV side.
S/E of stay set with 6’-0” long M.S. round rod of 16mm dia elbow and required size of the two angel iron of (50mmx50mmx6mm) each in length complete with all accessories as per satisfaction of Engineer-in-charge.
S/E of stay wire 7/8 SWG as per the satisfaction of Engineer-in-Charge
S/E of 11 KV gang operated switch confirming to ISI with latest amendments including suitable size of copper plate erection of the same on the existing ‘H’ pole including cost of 6No. KVGI pins insulator and 6No. 11 KV pin RD fuses with halt of 3 Nos channel of size 75mmx40mmx6mm fixed with suitable size of MS clamps nuts and bolts i/c painting with two coats of approved paint and one coat of red oxide make Power Tech/Jai Shree entire satisfaction of Engineer-in-charge.
S/E of 11 KV Droop out switch confirming to ISI with latest amendments including suitable size of copper plate erection of the same on the existing ‘H’ pole including cost of 6No. KVGI pins insulator and 6No. 11 KV pin RD fuses with halt of 3 Nos channel of size 75mmx40mmx6mm fixed with suitable size of MS clamps nuts and bolts i/c painting with two coats of approved paint and one coat of red oxide make Power Tech/Jai Shree entire satisfaction of Engineer-in-charge.
S/E of pin insulator confirming to ISS 781/1971 make Jai Shree / Goyal as per entire satisfaction of Engineer-in-charge
Supply and erection of prestressed cement concrete pole as per IS : 1678-1960. 9 m long 105 mm x 115 mm at top and 105 mm x 315 mm at bottom with working load of 200 Kg. buried 1.8 m in ground.
S/E of U/G cable loose in existing pipe or trenches complete with necessary connections Make:- Havell’s, Polycab, RR Kabel, KEI, Plaza 120 Sq mm 3.5 core cable unarmoured (For conne
S/E of XLPE cable 50 Sqmm 3 core HT Cable laid over head complete as per entire satisfaction of the Engineer-In-charge.
S/E of HT metering Cubical panel with CT-PT with all labour and materical to complete as per entire satisfaction of the Engineer-In-charge...
Painting charge after short blasting from inside and outside of the transformer 315KVA tank having hot oil resistant paint including radiator tubes and conservative tanks and other accessories with suitable primer and two coats of paint on transformer before cleaning of tank with complete all respect.
Magnetic type oil level gage with low level alarm contact complete as per original design of the transformer.
Repair and testing including over hauling of 11kv LT Coil and LT Rod 200 KVA Transformer replacement of its defective coil/rod.
Transformer 315KVA tank repairing charge for electrical welding complete all respect.
Transformer 200 KVA tank repairing charge for electrical welding complete all respect.
Buy back of old dismantle material (HT and LT coil, Rod, CT and PT, Old HT/LT cable, bushing, valve, gasket etc) with complete all respect...
Painting charge after short blasting from inside and outside of the transformer200KVA tank having hot oil resistant paint including radiator tubes and conservative tanks and other accessories with suitable primer and two coats of paint on transformer before cleaning of tank with complete all respect.
Repair and testing including over hauling of 11kv HT Coil and HT Rod for 315 KVA Transformer replacement of its defective coil/rod.
Repair and testing including over hauling of 11kv HT Coil and HT Rod 200 KVA Transformer replacement of its defective coil/rod.
Repair and testing including over hauling of 11kv LT Coil and LT Rod 315 KVA Transformer replacement of its defective coil/rod.
Bidder Name
Amount
Fortune Enterprises (GSTN-06AQAPK5263F3Z1) BID ID -1158798
DHEERAJ ENTERPRISES (GSTN-06AAKFD3784C1ZI) BID ID -1158835
Fortune Enterprises (BID ID -1158798)
Fortune Enterprises (BID ID -1158798)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .