Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
30 Dec 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
office of the S.E., EUDC-II, Sec-18, Noida.
office of the S.E., EUDC-II, Sec-18, Noida.
11 KV MES Feeder Jarjar Conductor Rabbit To Dog 18 KM Replacement , 9 11 Mtr 28 Nos ST Pole Replacement, LT ABC 3x95 Sq mm Cable 1200 Mtr Replacement Tree Cutting
2024_PVVNL_968016_3
E-Tender No. 49/2024-25, EUDC-II Noida
Open Tender
Electrical Works
Item Rate
60 days
office of the S.E., EUDC-II, Sec-18, Noida.
Attached in DOC
2 documents required · 2 mandatory
₹3,540
S.E. EUDC-II, Noida.
₹24,000
2 Jan 2025
3 Dec 2024
30 Dec 2024
3 Dec 2024
30 Dec 2024
3 Dec 2024
Amount
11 KV MES Feeder Jarjar Conductor Rabbit To Dog & Tree Cutting Under S/S Dhoom Manikpur
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 3 to 16
ST POLE 11MTR
PCC POLE 8.5MTR
STONE PAD
11KV XLPE 3X185
11KV O/D KIT
LT AB CABLE 3X120
DOG CONDUCTOR
11KV CROSS ARM
11KV T OFF CHANNEL
11KV PIN INSULATIOR
11KV DISC INSULATOR
EARTHING COMPLETE
STAY SET COMPLETE
GUARDING ANGLE 65X65X6
Errection of above Following material and Supply and errection of the DE-CENTRALISED material for completing the works as per RESPO.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule. Double Pole Structures (a) ST POLE 11MTR
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 'F' bracket 75x10mm, G.I.Nut bolt & washer, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. Single Pole (a) ST POLE 11 MTR AND PCC POLE 8.5MTR
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming. Single Pole and Double Pole (a) ST POLE 11 MTR AND PCC POLE 8.5MTR
FIXING OF PIN INSULATOR WITH PIN, COMPLETE WORK IN ALL RESPECT.
FIXING OF T OFF CHANNEL AS PER SITE REQUIREMENT.
FIXING OF CROSS ARM AS PER SITE REQUIREMENT.
FIXING OF STONE PAD AS PER SITE REQUIREMENT.
FIXING OF 11KV DISC INSULATOR WITH FITTINGS AS PER SITE REQUIREMENT.
FIXING OF GUARDING ANGLES AS PER SITE REQUIREMENT
Supply of 160mm OD PN-4-PE-80 Grade UV Stabilized HDPE Pipe.(PVVNL GTP APPROVED)
Drilling of dia 220 mm in two parallel bores for Double Curcuit by trenchless method by horizontal boring machine at a depth of 1.50 mtrs to 2.50 mtrs. (as requirement at site) below the ground level with complete work in all respect as per RESPO.
Laying of HDPE Pipe PE-80, PN-4, DN-160mm dia by HDD trenchless method for 11KV, 3x185sq.mm XLPE cable as per site requirement. (PVVNL GTP APPROVED HDPE PIPE SHALL BE SUPPLIED WITH INSPECTION.)
Laying and commissiong of 11KV 3x185sqmm XLPE Cable Double Ckt. in HDPE Pipe dia after digging HDD trenchless method boring including complete connections at both ends after providing and crimping of lugs of proper size for completion of work. as per site requirement.
Digging of pits of size 4 mtr x 4 mtr x 1.5 mtr for cable loop and making risers at double pole and re-filling of pits in proper manner with required material at kacha/pakka and hot mix road. (All Work and material in the scope of contractor)
Laying, Sagging, connecting, Re-sagging of overhead 11 KV 3X185 Sq.mm XLPE Cablemaking connection complete at both ends as per site requirement.
Preparation and Fixing of 11 KV Power Cable ends: Making and Fixing of 11 KV XLPE Heat shrinkable outdoor jointing kits suitable for 3x185sqmm XLPE Cable after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs with complete connention in all respect.
Driving of MS earth rod of size 20x2500 mm in earth and jointing through G.I. wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts for pole earthing. Supply Erection, fixing, grouting of stay rod in cement, sand and brick ballast in ration 1:4:8 in Block 600*600*300 mm with binding & nuzzling including providing & fixing of stay insulator complete in all respect with grouting. (All Work and Material in the scope of Contractor)
Laying, spreading, lifting and final sagging of 3 OR 4 phases ACSR Dog conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos OR 04 Nos. Conductor in parallel as per site requirement.
Laying, spreading, lifting and final sagging of AB Cable 3x120sqmm in accordance with Line chart includidng binding and fixing of all accessories as per site requirement.
Fixing, tightening & nozzling of stay set with wire and stay rod with the poles of required tension as per drawing, including providing & fixing of Stay Insulators of 11KV and Stay Clamps and Grouting of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:3:6 cement, sand, 20mm Stone grift) as per drg. Including back filling of soil and proper ramming etc.
PROVIDING AND FIXING OF HOLDING CLAMP AS PER REQUIREMENT.
PROVIDING AND FIXING OF EYE BOLTS AS PER REQUIREMENT.
PROVIDING AND FIXING OF NUT BOLT AND WASHERS AS PER REQUIREMENT
PROVIDING AND FIXING OF PG CLAMP (DOG TO DOG) AS PER REQUIREMENT
PROVIDING AND FIXING OF 11KV F BRACKET AS PER REQUIREMENT
Providing and Fixing of GI Wire 4&8 SWG 1/5mm as per site requirement.
Road Cutting and Road Restoration Charges for the above work.
TREE CHOPPING AND CUTTING IN THE WAY OF LINE BY BOOM BARRIER MACHINE.
Removal and Dismentaling of old and used Conductor from the site and safe carriage of its from the site to any store of PVVNL DISCOM including loading and un-loading both ends.
Removal and Dismentaling of old and Damaged PCC Pole from the site and safe carriage of its from the site to any store of PVVNL DISCOM including loading and un-loading both ends.
Removal and Dismentaling of old and Damaged ST Pole from the site and safe carriage of its from the site to any store of PVVNL DISCOM including loading and un-loading both ends.
Removal and Dismentaling of old and Damaged Cross Arm from the site and safe carriage of its from the site to any store of PVVNL DISCOM including loading and un-loading both ends.
RE-ARRANGEMENT OF DAMAGED CONDUCTOR AT KRISHNA FLOOR MILL
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 52 TO 63
11KV XLPE 3X185
11KV O/D KIT
11KVI/D KIT
11KV TOP CHANNEL
11KV DROPPER CHANNEL
DOG CONDUCTOR
ST POLE 11MTR
11KV PIN INSULATIOR
11KV DISC INSULATOR
11KV CROSS ARM
EARTHING COMPLETE
STAY SET COMPLETE
Errection of above Following material and Supply and errection of the DE-CENTRALISED material for completing the works as per RESPO.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule. Double Pole Structures (a) ST POLE 11MTR
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 'F' bracket 75x10mm, G.I.Nut bolt & washer, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. Single Pole (a) ST POLE 11 MTR AND PCC POLE 8.5MTR
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming. Single Pole and Double Pole (a) ST POLE 11 MTR AND PCC POLE 8.5MTR
FIXING OF PIN INSULATOR WITH PIN, COMPLETE WORK IN ALL RESPECT.
FIXING OF TOP CHANNEL AS PER SITE REQUIREMENT.
FIXING OF DROPPER CHANNEL AS PER SITE REQUIREMENT.
FIXING OF 11KV DISC INSULATOR WITH FITTINGS AS PER SITE REQUIREMENT.
FIXING OF CROSS ARM AS PER SITE REQUIREMENT
Supply of 160mm OD PN-4-PE-80 Grade UV Stabilized HDPE Pipe.(PVVNL GTP APPROVED)
Drilling of dia 220 mm in two parallel bores for Double Curcuit by trenchless method by horizontal boring machine at a depth of 1.50 mtrs to 2.50 mtrs. (as requirement at site) below the ground level with complete work in all respect as per RESPO.
Laying of HDPE Pipe PE-80, PN-4, DN-160mm dia by HDD trenchless method for 11KV, 3x185sq.mm XLPE cable as per site requirement. (PVVNL GTP APPROVED HDPE PIPE SHALL BE SUPPLIED WITH INSPECTION.)
Laying and commissiong of 11KV 3x185sqmm XLPE Cable Double Ckt. in HDPE Pipe dia after digging HDD trenchless method boring including complete connections at both ends after providing and crimping of lugs of proper size for completion of work. as per site requirement.
Digging of pits of size 4 mtr x 4 mtr x 1.5 mtr for cable loop and making risers at double pole and re-filling of pits in proper manner with required material at kacha/pakka and hot mix road. (All Work and material in the scope of contractor)
Laying, Sagging, connecting, Re-sagging of overhead 11 KV 3X185 Sq.mm XLPE Cablemaking connection complete at both ends as per site requirement.
Preparation and Fixing of 11 KV Power Cable ends: Making and Fixing of 11 KV XLPE Heat shrinkable outdoor jointing kits suitable for 3x185sqmm XLPE Cable after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs with complete connention in all respect.
Preparation and Fixing of 11 KV Power Cable ends: Making and Fixing of 11 KV XLPE Heat shrinkable Inddoor jointing kits suitable for 3x185sqmm XLPE Cable after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs with complete connention in all respect.
Driving of MS earth rod of size 20x2500 mm in earth and jointing through G.I. wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts for pole earthing. Supply Erection, fixing, grouting of stay rod in cement, sand and brick ballast in ration 1:4:8 in Block 600*600*300 mm with binding & nuzzling including providing & fixing of stay insulator complete in all respect with grouting. (All Work and Material in the scope of Contractor)
Laying, spreading, lifting and final sagging of 3 OR 4 phases ACSR Dog conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos OR 04 Nos. Conductor in parallel as per site requirement.
Fixing, tightening & nozzling of stay set with wire and stay rod with the poles of required tension as per drawing, including providing & fixing of Stay Insulators of 11KV and Stay Clamps and Grouting of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:3:6 cement, sand, 20mm Stone grift) as per drg. Including back filling of soil and proper ramming etc.
PROVIDING AND FIXING OF HOLDING CLAMP AS PER REQUIREMENT.
PROVIDING AND FIXING OF NUT BOLT AND WASHERS AS PER REQUIREMENT
PROVIDING AND FIXING OF PG CLAMP (DOG TO DOG) AS PER REQUIREMENT
PROVIDING AND FIXING OF ISI MARKED GI PIPE 6" DIA AS PER REQUIREMENT
Providing and Fixing of F BRACKET as per site requirement.
Road Cutting and Road Restoration Charges for the above work.
TREE CHOPPING AND CUTTING IN THE WAY OF LINE BY BOOM BARRIER MACHINE.
Removal and Dismentaling of old and used Conductor from the site and safe carriage of its from the site to any store of PVVNL DISCOM including loading and un-loading both ends.
Removal and Dismentaling of old and Damaged PCC Pole from the site and safe carriage of its from the site to any store of PVVNL DISCOM including loading and un-loading both ends.
Removal and Dismentaling of old and Damaged ST Pole from the site and safe carriage of its from the site to any store of PVVNL DISCOM including loading and un-loading both ends.
Removal and Dismentaling of old and Damaged Cross Arm from the site and safe carriage of its from the site to any store of PVVNL DISCOM including loading and un-loading both ends.
U/G CROSSING FOR 11KV CLAVE CONE MES
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 97 TO 104
11KV XLPE 3X185 cable
ST POLE 11MTR
STONE PAD
11KV DISC INSULATOR
11KV O/D KIT
EARTHING COMPLETE
TOP CHANNEL
DROPPER CHANNEL
Errection of above Following material and Supply and errection of the DE-CENTRALISED material for completing the works as per RESPO.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule. Double Pole Structures (a) ST POLE 11MTR
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 'F' bracket 75x10mm, G.I.Nut bolt & washer, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. Single Pole (a) ST POLE 11 MTR AND PCC POLE 8.5MTR
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming. Single Pole and Double Pole (a) ST POLE 11 MTR AND PCC POLE 8.5MTR
FIXING OF TOP CHANNEL AS PER SITE REQUIREMENT.
FIXING OF DROPPER CHANNEL AS PER SITE REQUIREMENT.
FIXING OF 11KV DISC INSULATOR WITH FITTINGS AS PER SITE REQUIREMENT.
FIXING OF 11KV STONE PAD AS PER SITE REQUIREMENT.
Supply of 160mm OD PN-4-PE-80 Grade UV Stabilized HDPE Pipe.(PVVNL GTP APPROVED)
Drilling of dia 220 mm in two parallel bores for Double Curcuit by trenchless method by horizontal boring machine at a depth of 1.50 mtrs to 2.50 mtrs. (as requirement at site) below the ground level with complete work in all respect as per RESPO.
Laying of HDPE Pipe PE-80, PN-4, DN-160mm dia by HDD trenchless method for 11KV, 3x185sq.mm XLPE cable as per site requirement. (PVVNL GTP APPROVED HDPE PIPE SHALL BE SUPPLIED WITH INSPECTION.)
Laying and commissiong of 11KV 3x185sqmm XLPE Cable Double Ckt. in HDPE Pipe dia after digging HDD trenchless method boring including complete connections at both ends after providing and crimping of lugs of proper size for completion of work. as per site requirement.
Digging of pits of size 4 mtr x 4 mtr x 1.5 mtr for cable loop and making risers at double pole and re-filling of pits in proper manner with required material at kacha/pakka and hot mix road. (All Work and material in the scope of contractor)
Laying, Sagging, connecting, Re-sagging of overhead 11 KV 3X185 Sq.mm XLPE Cable making connection complete at both ends as per site requirement.
Preparation and Fixing of 11 KV Power Cable ends: Making and Fixing of 11 KV XLPE Heat shrinkable outdoor jointing kits suitable for 3x185sqmm XLPE Cable after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs with complete connention in all respect.
Driving of MS earth rod of size 20x2500 mm in earth and jointing through G.I. wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts for pole earthing. Supply Erection, fixing, grouting of stay rod in cement, sand and brick ballast in ration 1:4:8 in Block 600*600*300 mm with binding & nuzzling including providing & fixing of stay insulator complete in all respect with grouting. (All Work and Material in the scope of Contractor)
PROVIDING AND FIXING OF HOLDING CLAMP AS PER REQUIREMENT.
PROVIDING AND FIXING OF ISI MARKED GI PIPE 6" DIA AS PER REQUIREMENT
Road Cutting and Road Restoration Charges for the above work.
TREE CHOPPING AND CUTTING IN THE WAY OF LINE BY BOOM BARRIER MACHINE.
Kunal Electricals (BID ID -4821255)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .