Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC VILL MOKHAWA TEHSIL GUDAMALANI DIST BARMER RAJASTHAN 344031 | GUDAMALANI | BARMER | RAJASTHAN | 344031 | L1 | Accepted-AOC LOWEST REASONABLE BID | |
| 2 | L2₹40.0 L+₹9.7 L (32.1%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹43.1 L+₹12.8 L (42.2%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Eligible bidder as not enlisted in b ii category therefore does not Satisfies the eligibility criteria as per NIT. |
| Sl No | Description | Qty | Unit | M/s SUNIL ENTERPRISES L2 | shree nathji trading corporation L3 | NAGEL ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down old Unsv GO's and supply & install 11 KV air break gang operated triple pole out door type gang operated air break switch mechanically operated, mounted on insulator and steel frame with operating mechanism worked from ground level with 09 Nos insulators outdoor type triple pole suitable for horizontal/vertical installation provided with locking arrangement consisting of MS channel HT post type insulator high pressure heavy tined copper alloy contact assembly suitable for 400 Amps current rating, including air break switch suitable for 11 KV, 400 Amps mounted on 06 Insulators with drop out fuse unit, operating rod 25mm dia GI medium grade pipe complete all as specified and directed by Engr-in-charges. | 6 | Each | 21,500 ₹1,29,000 | 24,000 ₹1,44,000 | 20,000 ₹1,20,000 Lowest |
| 2.00 | Matrial & labour for repair of GO's to smooth operation & alignment of contacts, connect/tighting of HT cable including greasing of moving mechanism, replacement of Male contact/moving contact blade, female contact/fix contact jaw, tinned copper flexible jumper, MS jumper carrier, back connector plate where required, nut-bolts washers etc. of required size and length and testing complete all as specified and directed by Engr-in-charges. | 8 | Each job | 3,000 ₹24,000 | 4,000 ₹32,000 | 2,000 ₹16,000 Lowest |
| 3.00 | Dismantling of ACSR or AAC conductors from overhead PCC/steel pole complete all as specified and directed by Engr-in-charges. | 1 | Qtl | 1,000 ₹1,000 | 450 ₹450 Lowest | 800 ₹800 |
| 4.00 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 m in depth in a hard/dense soil for laying underground cables/ errection of steel tubular poles / stay pit etc complete all as specified and directed by Engr-in-charges. | 216 | Cum | 185 ₹39,960 Lowest | 250 ₹54,000 | 300 ₹64,800 |
| 5.00 | M&L for spreading, levelling in layers n exc. 25 cm thick and ramming of sand cushioning to PVC/ XLPE cables with tibba sand and punning to provide required cover to UG cables complete all as specified and directed by Engr-in-charges.
Note :- For the purpose of payment only punned thickness will be measured. | 41.04 | Cum | 650 ₹26,676 | 700 ₹28,728 | 50 ₹2,052 Lowest |
| 6.00 | Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and directed by Engr-in-charges. | 1,334 | Each | 55 ₹73,370 | 80 ₹1,06,720 | 40 ₹53,360 Lowest |
| 7.00 | Returning, filling in incl spreading,levelling watering and well ramming in layer n exc. 25 cm in soil each layer complete specified and directed by Engr-in-Charge. | 148.5 | Cum | 65 ₹9,652.5 | 80 ₹11,880 | 50 ₹7,425 Lowest |
| 8.00 | Removing excavated surplus material to a distance n.exc 50 m and depostimg where directed at alevel n exc. 1.5 m above the starting point in any type of soil complete all as specified and directed by Engr-in-Charge. | 67.5 | Cum | 65 ₹4,387.5 | 100 ₹6,750 | 50 ₹3,375 Lowest |
| 9.00 | Supply, laying, jointing and testing HT XLPE cable, cross section area 120 Sqmm, 3 core, 11000 V, screened, PVC 'E' grade insulated bedded, galvanised steel (heavy duty ) strip or wire armoured with aluminium conductor, pressure earthed system, conforming to IS 7098 (Part-1 ) 1977 and Part-II of 1985, laid in pipes / ducts / trenches, under floor and roads or fixed to wall etc including taking out old unserviceable cable, any type, complete all as specified and directed by Engr-in-charges. | 400 | RM | 2,101 ₹8,40,400 | 2,150 ₹8,60,000 | 1,600 ₹6,40,000 Lowest |
| 10.00 | Supply, laying and testing electric under ground XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sqmm 3 Core in trenches, ducts, pipe on walls, poles complete all as specified and directed by Engr-in-charges. | 400 | RM | 1,700 ₹6,80,000 | 1,850 ₹7,40,000 | 1,400 ₹5,60,000 Lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
17 Jun 2026, 6:00 pmClosed
CWE ARMY JODHPUR
CWE ARMY MULTAN LINE ARMY AREA JODHPUR-342010
REPAIR / MAINTENANCE TO HT OVERHEAD DISTRIBUTION ON SYSTEM 11KV LINE OF E/M SERVICES, HT VCB/GO/DO OF 11KV AND CONNECTED WORKS AT MIL STN UDAIPUR UNDER AGE (I) UDAIPUR
2026_MES_767866_1
CWE (A) JODH/UDR- OF 2026-27(82627/37/E8)
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
UDAIPUR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
AGE (I) UDAIPUR
₹50,000
Yes
10 Aug 2026
26 May 2026
19 Jun 2026
26 May 2026
17 Jun 2026
10 Jun 2026
26 May 2026 - 9 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down old Unsv GO's and supply & install 11 KV air break gang operated triple pole out door type gang operated air break switch mechanically operated, mounted on insulator and steel frame with operating mechanism worked from ground level with 09 Nos insulators outdoor type triple pole suitable for horizontal/vertical installation provided with locking arrangement consisting of MS channel HT post type insulator high pressure heavy tined copper alloy contact assembly suitable for 400 Amps current rating, including air break switch suitable for 11 KV, 400 Amps mounted on 06 Insulators with drop out fuse unit, operating rod 25mm dia GI medium grade pipe complete all as specified and directed by Engr-in-charges. | 6 | Each | 31,00,000 | ₹1,86,00,000 |
| - | Matrial & labour for repair of GO's to smooth operation & alignment of contacts, connect/tighting of HT cable including greasing of moving mechanism, replacement of Male contact/moving contact blade, female contact/fix contact jaw, tinned copper flexible jumper, MS jumper carrier, back connector plate where required, nut-bolts washers etc. of required size and length and testing complete all as specified and directed by Engr-in-charges. | 8 | Each job | 31,00,000 | ₹2,48,00,000 |
| - | Dismantling of ACSR or AAC conductors from overhead PCC/steel pole complete all as specified and directed by Engr-in-charges. | 1 | Qtl | 31,00,000 | ₹31,00,000 |
| - | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 m in depth in a hard/dense soil for laying underground cables/ errection of steel tubular poles / stay pit etc complete all as specified and directed by Engr-in-charges. | 216 | Cum | 31,00,000 | ₹66,96,00,000 |
| - | M&L for spreading, levelling in layers n exc. 25 cm thick and ramming of sand cushioning to PVC/ XLPE cables with tibba sand and punning to provide required cover to UG cables complete all as specified and directed by Engr-in-charges.
Note :- For the purpose of payment only punned thickness will be measured. | 41.04 | Cum | 31,00,000 | ₹12,72,24,000 |
| - | Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and directed by Engr-in-charges. | 1,334 | Each | 31,00,000 | ₹4,13,54,00,000 |
| - | Returning, filling in incl spreading,levelling watering and well ramming in layer n exc. 25 cm in soil each layer complete specified and directed by Engr-in-Charge. | 148.5 | Cum | 31,00,000 | ₹46,03,50,000 |
| - | Removing excavated surplus material to a distance n.exc 50 m and depostimg where directed at alevel n exc. 1.5 m above the starting point in any type of soil complete all as specified and directed by Engr-in-Charge. | 67.5 | Cum | 31,00,000 | ₹20,92,50,000 |
| - | Supply, laying, jointing and testing HT XLPE cable, cross section area 120 Sqmm, 3 core, 11000 V, screened, PVC 'E' grade insulated bedded, galvanised steel (heavy duty ) strip or wire armoured with aluminium conductor, pressure earthed system, conforming to IS 7098 (Part-1 ) 1977 and Part-II of 1985, laid in pipes / ducts / trenches, under floor and roads or fixed to wall etc including taking out old unserviceable cable, any type, complete all as specified and directed by Engr-in-charges. | 400 | RM | 31,00,000 | ₹1,24,00,00,000 |
| - | Supply, laying and testing electric under ground XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sqmm 3 Core in trenches, ducts, pipe on walls, poles complete all as specified and directed by Engr-in-charges. | 400 | RM | 31,00,000 | ₹1,24,00,00,000 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.63 MB
BOQ_859915.xls
BOQ • 3.08 MB
TENDER37.pdf
Tender Documents • 1.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .