Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹25.9 L+₹93,260 (3.74%)Admitted-Finance PART III GANESH MURTHI NAGAR CAPT PRAKASH PETHE MARG CUFF PARADE ROAD COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Admitted-Finance | |
| 3 | L3₹26.7 L+₹1.8 L (7.04%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹28.4 L+₹3.5 L (14.1%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹28.6 L+₹3.7 L (14.7%)Admitted-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S Sneha Enterprises L3 | chowdeshwariconstructionco L6 | ANAND REFRIGERATION L5 | P LAXMI AND CO. L2 | GNANI BUILDERS L8 | D K Engineers and contractors L7 | SRI AYYAPPA ENTERPRISES L1 | SRI GANESH ENTERPRISES L10 | Raghu M Contractor L9 | MATA GUJRI CONSTRUCTION CO. L11 | RAHUL CONSTRUCTION L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | S&F for GI tubing 15 mm dia medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors including taking down existing complete all as specified & directed.. | 55 | RM | 290 ₹15,950 | 250 ₹13,750 | 175 ₹9,625 Lowest | 350 ₹19,250 | 350 ₹19,250 | 325 ₹17,875 | 175 ₹9,625 Lowest | 225 ₹12,375 | 200 ₹11,000 | 175 ₹9,625 Lowest | 420 ₹23,100 |
| 2.00 | S&F for GI tubing 20 mm dia medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors including taking down existing complete all as specified & directed. | 40 | RM | 380 ₹15,200 | 350 ₹14,000 | 275 ₹11,000 Lowest | 400 ₹16,000 | 460 ₹18,400 | 395 ₹15,800 | 275 ₹11,000 Lowest | 310 ₹12,400 | 300 ₹12,000 | 290 ₹11,600 | 465 ₹18,600 |
| 3.00 | S&F for GI tubing 25 mm dia medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors including taking down existing complete all as specified & directed. | 20 | RM | 430 ₹8,600 | 435 ₹8,700 | 340 ₹6,800 Lowest | 500 ₹10,000 | 600 ₹12,000 | 451 ₹9,020 | 350 ₹7,000 | 390 ₹7,800 | 400 ₹8,000 | 410 ₹8,200 | 555 ₹11,100 |
| 4.00 | Supplying and laying of CPVC pipes 20mm Outer dia, SDR 11 & Plain CPVC SDR 11 fittings on wall, ceiling and in floors including taking down existing complete all as specified & directed. | 25 | RM | 330 ₹8,250 | 250 ₹6,250 | 240 ₹6,000 | 300 ₹7,500 | 300 ₹7,500 | 421 ₹10,525 | 200 ₹5,000 Lowest | 275 ₹6,875 | 250 ₹6,250 | 260 ₹6,500 | 330 ₹8,250 |
| 5.00 | Supplying and laying of CPVC pipes 25mm Outer dia, SDR 11 & Plain CPVC SDR 11 fittings on wall, ceiling and in floors including taking down existing complete all as specified & directed. | 15 | RM | 410 ₹6,150 | 350 ₹5,250 | 325 ₹4,875 | 400 ₹6,000 | 380 ₹5,700 | 521 ₹7,815 | 275 ₹4,125 Lowest | 375 ₹5,625 | 350 ₹5,250 | 350 ₹5,250 | 375 ₹5,625 |
| 6.00 | S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in floors includinguding flat iron clamp for proper fixing including taking down of existing pipe complete all as specified & directed. | 80 | RM | 510 ₹40,800 | 450 ₹36,000 | 400 ₹32,000 | 450 ₹36,000 | 450 ₹36,000 | 551 ₹44,080 | 350 ₹28,000 Lowest | 400 ₹32,000 | 450 ₹36,000 | 475 ₹38,000 | 600 ₹48,000 |
| 7.00 | S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in floors includinguding flat iron clamp for proper fixing including taking down of existing pipe complete all as specified & directed. | 40 | RM | 340 ₹13,600 | 325 ₹13,000 | 310 ₹12,400 | 400 ₹16,000 | 380 ₹15,200 | 451 ₹18,040 | 275 ₹11,000 Lowest | 350 ₹14,000 | 300 ₹12,000 | 375 ₹15,000 | 555 ₹22,200 |
| 8.00 | S&F in repairs PVC (SWR) bends 110mm dia complete all as specified & directed. | 10 | Each | 280 ₹2,800 | 200 ₹2,000 Lowest | 400 ₹4,000 | 400 ₹4,000 | 300 ₹3,000 | 365 ₹3,650 | 300 ₹3,000 | 425 ₹4,250 | 400 ₹4,000 | 450 ₹4,500 | 600 ₹6,000 |
| 9.00 | S&F in repair PVC (SWR) bends 75mm dia complete all as specified & directed. | 8 | Each | 250 ₹2,000 | 180 ₹1,440 Lowest | 300 ₹2,400 | 350 ₹2,800 | 200 ₹1,600 | 325 ₹2,600 | 250 ₹2,000 | 350 ₹2,800 | 300 ₹2,400 | 400 ₹3,200 | 555 ₹4,440 |
| 10.00 | S&F in repair PVC (SWR) floor trap, 75mm dia outlet, plain with grating includinguding jointing with solvent cement complete all as directed. | 5 | Each | 380 ₹1,900 | 350 ₹1,750 | 400 ₹2,000 | 1,000 ₹5,000 | 250 ₹1,250 | 450 ₹2,250 | 400 ₹2,000 | 350 ₹1,750 | 400 ₹2,000 | 375 ₹1,875 | 240 ₹1,200 Lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
30 Oct 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
REPAIR TO INTERNAL WATER SUPPLY AND CONNECTED WORKS IN TECH AREA AT AF STN YELAHANKA
2026_MES_793099_1
8626/E8
Open Tender
Civil Works
Item Rate
120 days
GE (AF) Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹60,000
Yes
6 Nov 2026
9 Oct 2026
6 Nov 2026
9 Oct 2026
30 Oct 2026
23 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S&F for GI tubing 15 mm dia medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors including taking down existing complete all as specified & directed.. | 55 | RM | - | - |
| 2 | S&F for GI tubing 20 mm dia medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors including taking down existing complete all as specified & directed. | 40 | RM | - | - |
| 3 | S&F for GI tubing 25 mm dia medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors including taking down existing complete all as specified & directed. | 20 | RM | - | - |
| 4 | Supplying and laying of CPVC pipes 20mm Outer dia, SDR 11 & Plain CPVC SDR 11 fittings on wall, ceiling and in floors including taking down existing complete all as specified & directed. | 25 | RM | - | - |
| 5 | Supplying and laying of CPVC pipes 25mm Outer dia, SDR 11 & Plain CPVC SDR 11 fittings on wall, ceiling and in floors including taking down existing complete all as specified & directed. | 15 | RM | - | - |
| 6 | S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in floors includinguding flat iron clamp for proper fixing including taking down of existing pipe complete all as specified & directed. | 80 | RM | - | - |
| 7 | S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in floors includinguding flat iron clamp for proper fixing including taking down of existing pipe complete all as specified & directed. | 40 | RM | - | - |
| 8 | S&F in repairs PVC (SWR) bends 110mm dia complete all as specified & directed. | 10 | Each | - | - |
| 9 | S&F in repair PVC (SWR) bends 75mm dia complete all as specified & directed. | 8 | Each | - | - |
| 10 | S&F in repair PVC (SWR) floor trap, 75mm dia outlet, plain with grating includinguding jointing with solvent cement complete all as directed. | 5 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
Binder1.pdf
Tender Documents • 0.92 MB
BOQ_889383.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .