Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 CrAccepted-AOC C 9 53 IIND FLOOR SECTOR 08 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | ₹3.0 Cr | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹3.0 Cr+₹77,790.44 (0.26%)Rejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹3.0 Cr+₹77,790.44 (0.26%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹3.1 Cr+₹7.2 L (2.38%)Rejected-Finance 15 HOSHIYAR SINGH PARK KIRBY PLACE DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | ₹3.1 Cr+₹7.2 L (2.38%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹3.1 Cr+₹8.1 L (2.66%)Rejected-Finance E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | ₹3.1 Cr+₹8.1 L (2.66%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹3.3 Cr+₹24.1 L (7.94%)Rejected-Finance FARIDABAD | FARIDABAD | HARYANA | 121001 | ₹3.3 Cr+₹24.1 L (7.94%) | L5 | Rejected-Finance Not being lowest |
| Sl No | Description | Qty | Unit | M/S ANIL KUMAR L2 | Third Wave Services Pvt Ltd L10 | M/s. Kansal Construction Co. L8 | imran construction company L6 | Shivom Projects Private limited L3 | L G BUILDERS L1 | M/S SURINDERAS CONSTRUCTION CO. L7 | M/s Innovative Coolings and Constructions L9 | CHOPRA BUILDERS L11 | ASSOCIATED CONSTRUCTION CO. L5 | GIAN ENGINEERS L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubbing down with water etc including remove all debris at 2 KM away from site complete all as specified and directed. | 2,600 | Sqm | 9 ₹23,400 | 20 ₹52,000 | 10 ₹26,000 | 15 ₹39,000 | 5 ₹13,000 Lowest | 10 ₹26,000 | 20 ₹52,000 | 10 ₹26,000 | 25 ₹65,000 | 9 ₹23,400 | 5 ₹13,000 Lowest |
| 2.00 | M&L for 15 mm thick rendering in cement mortar on fair faces of brick work or concrete surfaces, applied in two layers i.e. 1st layer of 10 mm thick rendering in cement mortar (1:6 ) and 2nd (top) layer of 5 mm thick rendering in cement mortar (1:4 ) mixed with WPC finished even and fair etc complete all as specified and directed.
(Note:- WPC shall be measured and paid separately) | 900 | Sqm | 169 ₹1,52,100 | 300 ₹2,70,000 | 200 ₹1,80,000 | 349 ₹3,14,100 | 210 ₹1,89,000 | 200 ₹1,80,000 | 280 ₹2,52,000 | 250 ₹2,25,000 | 385 ₹3,46,500 | 290 ₹2,61,000 | 100 ₹90,000 Lowest |
| 3.00 | M&L for rendering 10 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and fair without using extra cement complete all as specified and directed. | 1,500 | Sqm | 169 ₹2,53,500 | 285 ₹4,27,500 | 200 ₹3,00,000 | 245 ₹3,67,500 | 180 ₹2,70,000 | 200 ₹3,00,000 | 150 ₹2,25,000 | 225 ₹3,37,500 | 320 ₹4,80,000 | 229 ₹3,43,500 | 120 ₹1,80,000 Lowest |
| 4.00 | M&L for rendering 5 mm thick in CM 1:3 on ceiling concrete surfaces finished even and fair without using extra cement complete all as specified and directed. | 200 | Sqm | 169 ₹33,800 | 275 ₹55,000 | 180 ₹36,000 | 300 ₹60,000 | 220 ₹44,000 | 210 ₹42,000 | 150 ₹30,000 | 225 ₹45,000 | 225 ₹45,000 | 190 ₹38,000 | 100 ₹20,000 Lowest |
| 5.00 | M&L for preparation of new plaster surfaces of wall and applying water proof wall putty 1-2 mm thickness over plastered surfaces to prepare the surfaces even and smooth and finishing walls with Two coats @ 1.67 ltr/10 Sqm each acrylic smooth exterior paint of required shade over and including priming coat of exterior primer @ 2.20 Kg/10Sqm complete all as specified and directed. | 900 | Sqm | 99 ₹89,100 | 175 ₹1,57,500 | 70 ₹63,000 | 95 ₹85,500 | 90 ₹81,000 | 18 ₹16,200 Lowest | 50 ₹45,000 | 225 ₹2,02,500 | 100 ₹90,000 | 99 ₹89,100 | 80 ₹72,000 |
| 6.00 | M&L for Preparation of new surfaces (Plastered or un-plastered) of walls and applying two coats of oil bound distemper complete all as specified and directed. | 1,500 | Sqm | 45 ₹67,500 | 60 ₹90,000 | 45 ₹67,500 | 75 ₹1,12,500 | 50 ₹75,000 | 35 ₹52,500 | 30 ₹45,000 Lowest | 55 ₹82,500 | 86 ₹1,29,000 | 49 ₹73,500 | 40 ₹60,000 |
| 7.00 | M&L for Preparation of new surfaces (Plastered or un-plastered) of ceiling and applying two coats of oil bound distemper complete all as specified and directed. | 200 | Sqm | 49 ₹9,800 | 60 ₹12,000 | 45 ₹9,000 | 70 ₹14,000 | 50 ₹10,000 | 40 ₹8,000 | 10 ₹2,000 Lowest | 55 ₹11,000 | 86 ₹17,200 | 39 ₹7,800 | 25 ₹5,000 |
| 8.00 | M&L for complete removal of existing treatment of old decorated plastered or unplastered surfaces of wall by rubbing , brooming down, washing with water etc and applying 1mm thick putty in two layers and two coats of oil bound distemper complete all a specified and directed. | 8,000 | Sqm | 45 ₹3,60,000 | 80 ₹6,40,000 | 40 ₹3,20,000 | 70 ₹5,60,000 | 63 ₹5,04,000 | 15 ₹1,20,000 Lowest | 70 ₹5,60,000 | 90 ₹7,20,000 | 90 ₹7,20,000 | 79 ₹6,32,000 | 45 ₹3,60,000 |
| 9.00 | M&L for preparation of old decorated plastered surfaces of walls, complete removal of existing tretament, by rubbing brooming down, washing with water etc and providing and applying 1-2 mm thickness wall putty over plastered surfaces to prepare the surface even and smooth and finishing wall surfaces by applying Two coats @ 1.67 ltr/10 Sqm each with acrylic smooth exterior paint of required shade over and including priming coat of exterior primer @ 2.20 Kg /10Sqm complete all as specified and directed. | 6,000 | Sqm | 59 ₹3,54,000 Lowest | 175 ₹10,50,000 | 70 ₹4,20,000 | 95 ₹5,70,000 | 81 ₹4,86,000 | 85 ₹5,10,000 | 100 ₹6,00,000 | 200 ₹12,00,000 | 100 ₹6,00,000 | 89 ₹5,34,000 | 90 ₹5,40,000 |
| 10.00 | M&L for dismantling water tanks of capacity exc 250 litres & n. exc 500 litres complete all as specified and directed. | 60 | Each | 115 ₹6,900 | 200 ₹12,000 | 500 ₹30,000 | 100 ₹6,000 | 90 ₹5,400 | 50 ₹3,000 Lowest | 50 ₹3,000 Lowest | 100 ₹6,000 | 500 ₹30,000 | 90 ₹5,400 | 50 ₹3,000 Lowest |
Tender Value
₹4.1 Cr
EMD Value
₹4.9 L
Closing Date
4 Dec 2025, 6:00 pmClosed
HQ Chief Engineer Delhi Zone
HQ Chief Engineer Delhi Zone Delhi Cantt-10
SPL REPAIR TO CERTAIN MD ACCN IN KANDHAR LINE UNDER GE CENTRAL DELHI CANTT-10
2025_MES_738638_1
CEDZ/TOKEN-41 OF 2025
Open Tender
Civil Works
Item Rate
365 days
Delhi Cantt-10
As per NIT
10 documents required · 10 mandatory
₹2,000
GE Central
₹4.9 L
Yes
30 May 2026
6 Nov 2025
9 Dec 2025
6 Nov 2025
4 Dec 2025
27 Nov 2025
6 Nov 2025 - 13 Nov 2025
SCHEDULE 'A' PART-I PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
M&L for 15 mm thick rendering in cement mortar on fair faces of brick work or concrete surfaces, applied in two layers i.e. 1st layer of 10 mm thick rendering in cement mortar (1:6 ) and 2nd (top) layer of 5 mm thick rendering in cement mortar (1:4 ) mixed with WPC finished even and fair etc complete all as specified and directed. (Note:- WPC shall be measured and paid separately)
M&L for complete removal of existing treatment of old decorated plastered or unplastered surfaces of wall by rubbing , brooming down, washing with water etc and applying two coats of oil bond distemper complete all a specified and directed.
M&L for preparation of new plaster surfaces of wall and applying water proof wall putty 1-2 mm thickness over plastered surfaces to prepare the surfaces even and smooth and finishing walls with Two coats @ 1.67 ltr/10 Sqm each acrylic smooth exterior paint of required shade over and including priming coat of exterior primer @ 2.20 Kg/10Sqm complete all as specified and directed.
S&F 15 mm bore tank nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed
S&F 20 mm bore tank nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed
Demolition Bricks (laid flat or on edge) or brick tiles in floors, roof, channels, kerbs, aprons, etc. (each layer) complete all as specified and directed.
Demolition Mud in roofs, any thickness, including plastering and lapping (whether full thickness removed or only a part thereof) complete all as specified and directed.
Removing soil excavated material exc. 1.5Km but n exc 5km and depositing where directed at above the starting point complete all as specified and directed.
M&L for Preparation of new surfaces (Plastered or un-plastered) of walls and applying two coats of oil bound distemper complete all as specified and directed.
M&L for Preparation of new surfaces (Plastered or un-plastered) of ceiling and applying two coats of oil bound distemper complete all as specified and directed.
M&L for preparation of old decorated plastered surfaces of walls, complete removal of existing tretament, by rubbing brooming down, washing with water etc and providing and applying 1-2 mm thickness wall putty over plastered surfaces to prepare the surface even and smooth and finishing wall surfaces by applying Two coats @ 1.67 ltr/10 Sqm each with acrylic smooth exterior paint of required shade over and including priming coat of exterior primer @ 2.20 Kg /10Sqm complete all as specified and directed.
Demolition of brick work built in cement or cement lime mortar of any description including quoins,arches,pillars,etc., complete all as specified and directed
Taking down chowkhat or frame not exceeding 1.5 sqm each with shutter (without taking off shutter from the frame) complete all as specified & directed
Taking down chowkhat or frame exceeding 1.5 Sqm each and not exceeding 4 Sqm each sqm each with shutter (without taking off shutter from the frame) complete all as specified & directed
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 65 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with meter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified & directed. (M.S. hold fast/ lugs or SS dash fasteners shall be measured and paid for separately). Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
M&L for cement concrete 1:2:4 type B1 (using 12.5mm graded stone crushed aggregates) on roof padding, surface finished even and smooth without using extra cement complete all as specified and directed.
S&F Factory Made single extruded WPC (Wood Polymer Composite) Solid door/window/Ceosetory windows & other frames/ chowkat of size 65 x 125 mm comprising of virgin PVC polymer of K value 50-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non-toxic additives (max toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face & 1100 N Edge), min compressive strength of 58N/sqmm and resistance to flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed with MS Holdfast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engr in charge. Note: For WPC solid door/windows frames,minus 5mm tolerance in dimension i.e depth and width of profile dimension on plus side shall be acceptable but no extra payment on this account shall be made.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with meter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
M&L for PCC 1 : 4 : 8 type D2 using 40mm graded stone crushed aggregates as in foundation of manholes, posts etc complete all as specified and directed.
M&L for PCC 1 : 2 : 4 type B1 using 20mm graded stone crushed aggregates as in surfaces channels and drains complete all as specified and directed.
S&F Aluminium window for outer frame 40mmx114mm with 1.3mm thickness ,corner 45 degree cut & aluminum welded center mullion size 40mmx65mm also welded, shutter(02) size 40mmx60mm 1.3 thickness 45degree cut mechanically joint with 6mm alen key bolt clamp , 12mm SS 202 grade round bar at 100mm cc distance in middle 150mm cc distance for safety grill welded at both ends with 6mm ss 202 grade round bar, 5mm clear glass both side EPDM rubber gasket metal body hand lever type single point lock , aluminum kobra hinges 2 nos per shutter , 40x18mm 45 degree cut & welded mosquito net shutter(02) with 0.45mm nominal dia of SS wire mesh,SS 75mm long hinges & pvc magnet,full system powder coating with pure polyster coat of any shade as approved by GE and installing with SS screw roll plug and filled with silcone complete all as specified and directed.
M&L for providing and applying the plaster with single component ready to use repair mortar (SMART CARE REPAIR MORTAR or equivalent) capable of applying 15mm average thickness in single layer and finishing with trowel with a bond coat: SBR polymer or equivalent (@ 10% of cement weight) modified cementious bond coat @ 2.2 kg cement/Sqm of surface area mixed with specified portion of AP SMARTCARE or equivalent complete all as specified and as per manufacturer's instructions.
S&F ventilator outer frame 40mmx40mm with 1.3mm thickness, corner 45 degre cut & aluminum welded center mullion size 40mmx65mm also welded , fixed 5mm frosted glass EPDM rubber gasket with provision for fresh air fan, full system powder coating with pure polister coat of any shade install with SS
screw rol plug pvc & silicone complete all as specified & directed
S&FMCB confirming to ISI/IEC -60898-1 (2002), SP, AC, 240 volts, of 6-32 Amps capacity "B" curve, 10 kA breaking capacity & making connection by using using suitable copper lugs complete all as specified and directed.
S&F stainless steel continuous (Piano) hinges, bright finish, width of flap when open 30mm, complete all as specified & directed.
S&F of stainless steel handles 100 mm size for kitchen cabinet shutters and bed room cub boards complete all as per specified and directed.
S&F brass chromium plated tubular hanger rod 20 mm dia with suitable brackets complete all as specified and directed.
S&F for PVC magnetic door catches of kitchen cabinet and similar work fixed with MS screws complete all as specified & directed
S&F SS butt hinges medium weight 100mm size fixed with SS screws (ISI Marked) complete all as specified & directed
S&F SS barrel tower bolt extruded section 150mm long and fixed with SS Screws (ISI Marked) complete all as specified & directed
S&F 150mm extruded SS handle fabricated type and fixed with SS Screws(ISI Marked) complete all as specified & directed
S&F 300mm extruded section SS sliding door bolt with hasp and staple and fixing bolt and nut (ISI Marked) complete all as specified & directed
S&F for 300 mm MS ordinary rat tail rod pattern spring including roller and roller plate complete fixed on wooden frame or on wall with wooden plugs and set in cement mortar complete all as specified & directed.
Dismantling of wall and ceiling/cupboard board fibre pulp AC boards etc any thickness including cover fillets removing the wiring complete all as specified & directed
M&L for preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed
Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 15mm etc complete all as specified & directed
M&L for providing and applying Smartcare Dampproof or equivalent, a fibre reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having Sun Reflectivity Index (SRI) of 105 on horizontal/vertical surfaces of roof/wall/chajas in multiple coats @2.0 litre/sqm. Primary coat is self-priming coat of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1, damp proof : water) and other coats to be applied undiluted. The coating needs to be reinforced with 40 GSM geotextile, to sandwiched between 2nd & 3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes complete in all respect as per manufacturer's instructions and all as specified & directed.
S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body
Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 20mm etc complete all as specified & directed
S&F Aluminium window Outer frame 40mmx114mm with 1.3mm thickness ,corner 45 degree cut & aluminum welded center mullion size 40mmx65mm also welded, shutter (02) size 40mmx60mm 1.3 thickness 45degree cut mechanically joint with 6mm alen key bolt clamp , 12mm SS 202 grade round bar at 100mm cc distance in middle 150mm cc distance for safety grill welded at both ends with 6mm SS 202 grade round bar, 5mm clear glass both side EPDM rubber gasket metal body hand lever type single point lock , aluminum kobra hinges 2 nos per shutter , 40x18mm 45 degree cut & welded mosquito net shutter(02) with 0.45mm nominal dia of SS wire mesh,SS 75mm long hinges & pvc magnet,full system powder coating with pure polyster coat of any shade as approved by GE and installing with SS screw roll plug and filled with silcone complete all as specified and directed. NOTE:- For installation of windows AC/desert cooler the provn of window glass shutter with wire mesh,grill and necessary fittings and locking arrangement for subject portion will be modified as per ground requirementt during execution as direction of Engg-in-Charge.
threaded star headed counter sunk S.S screws, complete all as specified & directed. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately).
S & F Floor door stopper 150mm size of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified & directed
S&F in repairs Glass Corner Shelf 6mm thick including CP railing radius 250mm complete all as specified and directed by Engineer-in-Charge.
S&F in repairs bib taps 15 mm bore chromium plated brass, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule Make-Jaquar/marc/Kohlar, complete all as specified & directed
S&F in repairs angle valve, fancy type, chromium plated brass, 15mm, complete all as specified & directed
S&F in repair vitreous china wash down water closet EWC white/ ivory/off white (closedpattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flushpipe) complete in all respect complete all as specified & directed
S & F in repair towel rail 600mm long brass chromium plated of 20mm dia (external) and 1mm thickness with gutties embedded in cement mortar 1:3 with MS screws etc complete all as specified and directed.
Demolition of stone slab and tiles of any description or thickness in floor apron etc complete all as specified and directed.
Dismantling of floor of size not exc 1.50 Sqm for IWC and removing out the cinder/concrete from sunken protion, cleaning of RCC surface to remove dust, loose particle with compressed air or any other suitable method depending on site conditons, grinding any sharp edges etc all as specified and directed. (a) Cleaning or RCC surface to remove dust, loose particle etc with compressed air or any other particles or any other suitable techniques on site conditions etc. (b) M&L for a glass fibre reinforced acrylic modified cementitious coating system with base coat of Sika Top & Seal-107 @ 1.50 Kg/Sqm glass fibre reinforcement Sika® Fab-I and top coat with Sika Top® Seal-107 @ 1.50 Kg/Sqm or equivalent of Fosroc or Pidilite. (c) M&L for protection plaster 15mm thick on cement mortar 1:3 admixed with appropriate integral water proofing compound with Sika ® Plastocrete plus as specified. (d) M&L for providing 25mm dia GI pipe spout projecting at least 150mm beyond outer face of wall. (e) M&L for sunken portion filled with 40 mm graded brick bats and finished with 50 mm thick PCC 1:2:4 type B1 all as specified and directed. (f) Cost of the above aspect shall be deemed to be included in the quoted rates of the respective item and nothing extra shall be paid on this account. Note : The work will be executed by authorised manufacturers/applicator.
Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in soft/loose soil complete all as specified and directed
M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors over and including 15mm thick screed bed in cement mortar 1:4 set and jointed in neat cement slurry and pointed in coloured cement. complete all as specified and directed
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc incl brushing neat cement slurry with 3.0kg of cement per sqmtr complete all as specified and directed.
M&L glazed ceramic coloured tiles in vertical surface 600x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed 10mm thick in CM (1:3) complete all as specified & directed.
M&L for Granite (of any type) work, 18-20 mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms with necessary hole for gas pipe where ever required and likes over and including cement mortar bedding of 20 mm thick in CM 1:4 including pointing in white cement using marble dust with admixture of pigment to match including rounded edges with shade of granite complete all as specified and directed.
M&L for machine cut kota stone slab flooring, and (one Pieces) as in tread, riser, landing, 20-25 mm thick over and including cement screed bed 20mm thick in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.
M&L for chipping out spilled and loose concrete cover and derusting steel reinforcement of concrete column, beam, slab, chajjas, parapets and the like as directed up to 25 to 35mm thick roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry including derusting steel wire reinforcement, providing fabric MS wire mesh 75 x 75 x 2mm as reinforcement to concrete surface applying adhesive/admixture over steel mesh and providing 25mm average thickness guniting mix using one part of OPC 53 grade and two part of sand mixed with adhesive/admixture @ pressure of 2.5 to 3.00kg/Sqcm by guiniting machine and surface finished even and fair including necessary padding, shuttering/scaffolding, formwork (guniting work to be carried out up to 10 metre height) complete all as specified and directed Note :- (a) After placing the additional reinforcement all concrete surfaces shall be thoroughly scrubbed with wire brushes, washed with water and allow to dry, apply chemistic polycretes admixture @ 2.25 kg by weight of cement all as per manufacturers instruction. (b) when polymix concreting in taking condition,guiniting is done with polycrete admixture @ 2% by weight of cement all as per manufacturers instructions (polycrete admixture shall be procured from chemical adhesive Pvt Ltd Co or their authorised dealer). (c) Cost of the above aspect shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account.
M&L for removal of plant growth by injection with chemical glyphosphate solution (4 % concentration) @ 20 ml or till refuse by cutting or injection in stem of plants or roots at 30 mm. The area shall then be sprayed with solution 25 ml glyphosphate (4% conc) diluted with 1 ltr of water. All roots of plants shall be removed completely and making good the disturbed surface and painted with cement base or acrylic paint complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in any floor n.exc 15cm thickness ( below or above ground level ) not otherwise specially provided including removal of rubbish out sid
e complex (MOD land), complete all as specified and directed
Use and waste of form work to soffits of suspended slabs such as roof slab, Chajja, platforms and landings etc not exc 200mm thick (horizontal or sloping) for fair finished surfaces of concrete complete all as specified and directed.
M&L for 40 mm thick cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in floor & surfaces finished even and fair using extra cement, complete all as specified and directed
Demolition of reinforced cement concrete in any position complete all as specified and directed
S&F TMT mild steel bars of 10 mm dia and over, cut to length bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to. complete all as specified and as directed.
Demolition and breaking up rain water pipes (CI,AC,PVC etc) set in any cement mortar of any diameter including bends complete all as specified and directed .
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, soil, waste, vent pipe in any length with or without ears ,110mm bore complete all as specified and directed .
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, soil, waste, vent pipe in any length with or without ears 75 mm bore complete all as specified and directed
All as per item no. 84 here in before but on vertical surfaces as in skirting etc over and including 10mm thick screed bed in CM 1:3, set and jointed in white cement with pigment to match all as specified and directed.
S&F in repairs chromium plated soap dish fancy type complete all as specified & directed
S&F for 100 PVC (SWR) bends with door plate & tee complete all as specified and directed.
S&F for 75 mm PVC (SWR) bends with door plate & tee complete all as specified and directed.
S&F for 75 mm bore PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in solvent cement concrete complete all as specified and directed.
S&F in repair 20 mm nominal dia and minimum thickness 1.2mm of SS-304 Grade of Stainless Steel tube for curtain rod including pair of suitable S.S brackets approved by GE including taking down old pelmet boxes with curtain rods complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for parapet railing, balconies, tank staging, metre rooms shaft area any description complete as specified and directed.
S&F for PVC (SWR) bends & tee any radius, 110 mm bore complete all as specified and directed.
S&F rolled sections as in main and cross beams, hip and jack rafters; purlins , pillars, trusses , water tank stage , framed guard bars, barred iron doors, ladders, frame balusters, walk ways, railing and similar work where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed
S&F for PVC (SWR) bends & tee any radius, 75 mm bore complete all as specified and directed.
S&F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge
Supply and fix welded steel wire fabric(MS Jali) fixed to steel members weight n. exc. 4 kg/sqm including welding complete all as specified and directed.
M&L for reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone crushed aggregate) as in roof slabs, slab supported on walls, cooking platform, beams and columns, in floors roofs, landings, balconies, canopies and in chajjas, parapet, shelves and the like complete all as specified and directed.
M&L for removal of plant growth by injection with chemical glyphosphate solution (4 % concentration) @ 20 ml or till refuse by cutting or injection in stem of plants or roots at 30 mm. The area shall then be sprayed with solution 25 ml glyphosphate (4% conc) diluted with 1 ltr of water. All roots of plants shall be removed completely and making good the disturbed surface and painted with cement base or acrylic paint complete all as specified and directed.
Dismentling asbestos cement corrugated or semi corrugated sheets in roof fixed with L hook or cranked bolt complete all as specified and directed
M&L for rendering 15mm thick on top of roof concrete in cement mortar 1:4 with water proofing compound @ 3% by weight of cement to have a smooth surface for laying of water proofing membrane. Note: Water proofing compound will be measured and paid seprately.
S&F in repairs two legged aluminium floor door stopper with rubber shoe 140mm long complerte all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick PCC type D-2 1:4:8 (40mm graded aggreate) as sub-base complete all as specified and directed
S&F for PVC (SWR) door plates , T junction 110 mm bore complete all as specified and directed.
S&F for PVC (SWR) door plates , Y junction 110 mm bore complete all as specified and directed.
M&L for Providing PCC in coping type B-1, 1:2:4 using 12.5mm graded stone aggregate complete all as specified including necessary form work and finishing the exposed surface even and smoth with using extra cement complete all as specified and directed
M&L for broken stone boulders of hard core of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces complete all as specified and directed
ROAD, PATH AND CULVERT
SEWAGE DISPOSAL
Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil complete all as specified and directed
Removing excavated materials to a distance exc 1.50 Km but not exc 5 Km outside defence land and depositing where directed complete all as specified and directed
Demolition of brick work built in cement or cement lime mortar of any description including quoins,arches,pillars,etc., complete all as specified & directed
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stoped ends etc complete all as specified and directed.
S&F DWCPE(SN8) 150mm dia (Internal Dia) pipes, snap fit coupler and rubber ring including testing and laid and properly jointed laid in trenches to a level on concrete bed complete all as specified and directed.
M&L for Brick work with sub class ‘B’ bricks straight or curved on plan, built in cement mortar 1:4 using old size bricks complete all as specified and directed.
M&L for precast factory made manhole cover, area of each cover n.exc 0.60 Sqm, 100mm thick with SFRC concreting including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 100mm internal dia pipe, complete all as specified.
M&L for precast cement concrete 1:2:4 type B-0 (using 12.5mm stone crushed graded aggregate) as in louvers and jallies 25mm thick designed as fort pattern (measured solid) including all moulding but exceeding frame and set in CM1:4 all as per sample shown complete all as specified and directed
Demolition and breaking up drain pipes (glazed stone ware, AC or reinforced concrete),150 mm dia pipe of any description and in any position set and jointed in cement mortar complete all as specified and directed by Engr-in-Charge
INTERNAL ELECTRIFICATION
All as per item no 130 here-in-above but except bricks
Taking down old MCCB , TPN DBs , SPN DBs (incl MCB SPN & SP) & main switch/ enclosure box of any make and type from the site and making good surface complete all as specified and directed.
Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed.
Disconnecting elect connection and taking down of ceiling fan/ Exhaust fan of any make and any height, dismantling blade and removing fan alongwith blade for depositing in MES store yard complete all as specified and directed by Engr- in- Charge.
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
M&L for PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregates in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item water troughs and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
One light /Ceiling fan/exhaust fan point controlled by one switch.
One light point controlled by two, two way switch ( switch to be measured and paid separtely)
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
One bell point controlled by one bell push.
S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer?In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately). Note: MTC and Screw Out Test shall be provided by Contractor
Supply and fixing 30mm thick FACTORY MADE WIRE MESH SOLID WPC DOOR SHUTTER consisting of density 650 kg/cbm manufactured by an ISO-9001-2015 certified company. Door to be panelled with SS mosquito and XTN aluminium mesh for additional strength and safety purpose (confirming as per IS 4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 nos. SS butt hinges size 100mmx25mmx2mm and 32mm long steel screws drilled suitable to pass through other hardwares should be fixed with 19x6mm size steel screws, etc. complete all as specified& directed.” Note: MTC and Screw Out Test shall be provided by Contractor
S&F for glazed Ceramic tiles 9 to 10 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed..
M & L for brick work with Cement Mortar 1:6 using sub class 'B' bricks, old size, straight or curved on plan exceeding 6 m mean radius complete all as specified and directed.
M&L for point wiring complete with 1.5 Sqm single core PVC insulated unsheathed FRLS cable 1100 volts grade (ISI marked) with multi stranded copper conductor drawn through and including non-metallic rigid PVC medium grade conduit of 20 mm nominal dia and conduit accessories (ISI) marked concealed in wall/fixed to roof, ceiling etc and including provn of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS (ISI marked) as earth continuity conductor, fabricated sunken terminal box made out of 1.60 mm thick sheet steel concealed in walls, with modular sheet ISI marked top cover with brass/chromium plated screws and cup washers for housing switches, socket outlets, fan regulators etc, complete all as specified and directed for the following:-
M&L for switch Modular type 6 Amp two way ISI marked complete all as specified and directed. Make : Legrand Cat Part No 2573402/ Schnider Cat No X1002WH/ Wipro Cat No RF 210
All as per item Ser No 142 here-in-before but point wiring with 2.5 sqmm single core FRLS 1100 Volts in New PVC concealed conduit medium grade ISI Marked not less than 20 mm dia in new M S steel terminal boxes modular including one run of using 2.5 sqmm single core FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one 15 A switch socket power point, complete all as specified and directed
M&L for switch Modular type type 16 Amp one way, ISI marked complete all as specified and directed Make : Legrand Cat Part No 573410/ Schnider Cat No X11001WH/ Wipro Cat No RF 130
M&L for switch Modular type 6 Amp one way ISI marked complete all as specified and directed. Make : Legrand Cat Part No 57340
0 / Schnider Cat No X1001WH / Wipro Cat No RF 110
M&L for Modular type socket outlet 2 in 1,5 pin 6/16 Amps, ISI marked complete all as specified and directed. Make : Legrand Cat Part No 573471/ Schnider Cat No X2106WH/ Wipro Cat No R 1332P
M&L for ceiling rose 3 phase PVC polycorbonate,isolated body, complete all as specified and directed
M&L for submain wiring 4 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of suitable dia, medium grade with all conduit accessories and connected to common earth dolly to suitable copper lugs including all cutting/chases etc in walls and making good to the disturbed surfaces to match the existing surfaces. Note:- Three run of single core wire and one run of conduit shall be measured and paid as one unit complete all as specified and directed
M&L for angle Lamp holder with metallic ring, PVC/Polycorbonate type with back plate complete all as specified and directed.
S&F LED bulb 12 watts, 1200 lumens output, 6500K suitable for B-22 base complete all as specified and directed.
All as per item ser No 144 here-in-before but for 02 x 6 Sqmm for phase & neutral and 01 x 6 Sqmm for continuous earth wire concealed/surface
M&L for bell push,modular type, 6 Amp, 1 module ISI marked complete all as specified and directed. Make : Legrand Cat Part No 573413/ Schnider Cat No X1005WH/ equivalent in Wipro
S&F sheet metal enclosure distribution board confirming to IEC - 61439-3, single pole and neutral, AC 240 volts, 12 way witn 100 Amps rated copper bus bar and metal double door with IP-43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete ( Note - MCB & DB shall be of same make)
S&F sheet metal enclosure distribution board confirming to IEC - 61439-3, single pole and neutral, AC 240 volts, 08 way witn 100 Amps rated copper bus bar and metal double door with IP-43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete ( Note - MCB & DB shall be of same make)
S&F in replacement of LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than
Supply and fix in replacement 10 watts bulkhead fitting, IK 09 with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover,including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
1000 lm with life time of 25000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.90, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 140 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥120 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
Supply and fix in replacement LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts with lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.90, THD< 20%, colour temperature - 6500K, surge protection 3KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 140 to 270 Volts AC, temperature range 0 to 50 Degree C, system efficency at luminaire level > 120 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
M&L for bell ding dong AC, 230 volts, single pole complete all as specified and directed.
M&L for in replacement Decorative wall mounting CITY-1 Decorative wall light fixture made up of Polycarbonate,Power Factor > 0.90 voltage range - 140 to 270 Volts AC, temperature range 0 to 50 Degree C, system efficency at luminaire level > 110 Including 12 W retrofit LED BULB (B-22 base). NOTE- one piece of LED bulb 12 watts included with city -1 fitting complete all as specified and directed.
Taking down existing electric meter & refixing the same after completion of job with electric connection by 8 way DB in good way by cleaning and qtr No. marking complete all as specified and directed..
Supply and fixing exhaust fans metal body AC single phase 230/240 V of size 300 mm sweep, Air flow rate > 900cum/min, Bird screen for protection against birds, double ball bearing, metal body with louvre also with louvre for fixing of exhaust fan complete all as specified and directed.
M&L for Modular type socket outlet 2 in 1, 5 pin 6 Amp , ISI marked complete all as specified and directed. Make : Legrand Cat Part No 573424/ /Schnider Cat No X2005WHNS/ Wipro Cat No R 1212
M&L for earthing complete with GI electrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earth plate not less than 1.50 mtr below normal ground level connected to GI wire 4.0 mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze drilled and screwed all as specified including excavation and earth work and disposal of surplus soil incl 15 mm GI tubing light grade and necessary fitting for protection of GI wire incl laying of alternate layer of charcoal dust and common salt PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MS angle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia GI pipe Medium grade for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed. Note:- Galvanised wire and protection light grade GI pipe upto 7.5 mtr, excavation, etc shall be deemed to be in the quoted rates.
S&F modular type sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity, including fixing completly in wall complete all as specified and directed.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.19 MB
uploadtender.rar
Tender Documents • 2.00 MB
BOQ_827078.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .