| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.5 LAccepted-AOC FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L1 | Accepted-AOC LOWEST QUOTED BIDDER | |
| 2 | L2₹50.8 L+₹4.3 L (9.19%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
Tender Value
₹52 L
EMD Value
₹1.0 L
Closing Date
7 Sept 2022, 6:00 pmClosed
CWE AF SECUNDERABAD
CWE AF SECUNDERABAD BOWENPALLY POST SECUNDERABAD 500011
PROVISION OF SUN SHELTERS WITH INTEGRATED FLOOD LIGHTS AND HIGH MAST FLOOD LIGHT FOR MT YARD AT AFA HYDERABAD
2022_MES_542979_1
86682/E8
Open Tender
Civil Works
Item Rate
180 days
GE AFA HYDERABAD
AS PER NIT
9 documents required · 9 mandatory
₹1,000
GE AFA HYDERABAD
₹1.0 L
Yes
12 Sept 2022
3 Aug 2022
9 Sept 2022
3 Aug 2022
7 Sept 2022
24 Aug 2022
3 Aug 2022 - 20 Aug 2022
Amount
SCHEDULE 'A' PART -I (B/R PORTION) :- Excavating in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and not exc 1.5 mtr in depth and getting out in hard / dense Soil complete all as specified and as directed.
M& L for Plain Cement concrete 1:4:8 type D-2 mix (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for RCC M-25 mix (using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for RCC M-25 mix (using 20 mm graded stone aggregate) as in columns, pillers, piers, posts and struts complete all as specified and as directed.
M&L for RCC M-25 mix (using 20 mm graded stone aggregate) as in beams,cantilevers, bressummers, lintels over 1.5 mtr span complete all as specified and as directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter including fairfinished surfaces complete all as specified and as directed.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed.
M&L for Mild Steel TMT bars 10 mm dia and over cut to length bent to shape required including crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
M&L for Mild Steel TMT bars 6 mm to 8 mm dia cut to length bent to shape required including crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
M& L for Pre-cast cement concrete block masonry type C1 (1:3:6) using 20 mm graded stone aggregate with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, as in lining the edges of interlocking tiles complete all as specified and as directed.
M & L for Rendering 10 mm thick on fair faces of brick work or concrete wall surfaces in CM 1:4 finished even & smooth without using extra cement complete all as specified and as directed.
M&L for applying two coats of cement based paint on walls including reparation of new plastered surfaces over a coat of primer complete all as specified and as directed.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M& L for 100 mm thick Plain Cement concrete Type D- 2 mix PCC 1:4:8 (using 40 mm graded Aggregate) as in sub base flooring complete all as specified and as directed.
M&L 100 mm thick plain Cement concrete type B-1 mix , 1:2:4 (using 20 mm graded aggregate) as in floor finish etc concrete complete all as specified and as directed.
M&L for forming Contraction (Dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound Grade 'A' complete all as specified and as directed.
S&F Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates etc, conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
S&F steel work in tubular trusses including special shaped washer etc, complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade ST-240 complete all as specified and as directed.
S&F Plates (Plain or chequered) channels, square cut or notched (ordinary and countersunk) forming holes, with riveted, bolted or welded attatchment, conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut n exc 5 cm long dia of neck 11 to 15 mm.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 30 cm long dia of neck exc 12 n exc 20 mm complete all as specified and as directed.
S&F Pre painted galvalume aluminium zinc coating GI based corrugated sheet 0.5 mm thick of an colour having tensile strength of 550Mpa as in roof covering / cladding to wall with self tapping screws complete all as specified and as directed.
S&F Self supported roofing pre-painted colour coated Galvalume corrugated steel sheet 0.9 mm thick as in trussless roof covering sheet comes in cold roll coils of width 0.914 mtr using requisite tools / plant for moulding sheet as well as errecting machine at site including necessary fittings / fixtures and sealing the joints all as per manufacturer instructions complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated soil not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed.
M&L for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe 290 Gde E-165 complete all as specified and as directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, 110 mm dia as rain water take down pipes complete all as specified and as directed.
M&L for Preparation of new steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
S&F Pre painted galvalume aluminium zinc coating GI based plain sheet 0.5 mm thick of an colour having tensile strength of 550Mpa as in roof gutters with self tapping screws etc complete all as specified and as directed.
SCHEDULE 'A' PART (E/M) PORTION :- Design,fabrication supply, installation testing and commissioning of HIGH Mast of 16 Mtr made up of average thickness 70 micron suitable for holding 9 lantern symmetrically fitted along with control gear The mast shall be in two sections made out of BSEN 10025 suitable to withstand wind 47 m / sec, the top section of 150mm dia and 3mm minimum thickness and bottom section 410 mm dia and and 4 mm minimum thickness with stress slip fit joints with overlap of 1.5 times the insertion of larger dia and base plate of minimum 610 mm dia and minimum thickness of sheet 20mm thick, minimum length and dia of foundation bolt and No of foundation bolts, including foundation of earthwork in any type of soil, foundation concrete of PCC 1:4:8, type D- 2 mix using 40 mm graded stone aggregate and RCC M-30 (Design mix) using 20 mm graded stone aggregate all shall be as per design of OEM. including 5 Core 2.5 sqmm flexble cable for necessary connection complete all as specified and as directed for following accessories :-
(a) Supply, Installation, Testing & commissioning of outdoor type panel floor mounted (with bolts and nuts) panel size 0.45 mtr X 0.30 mtr X 0.20 Mtr and made out of 3.15 mm thick CRCA MS sheet with front side openable . All door should have neaprene rubber gasket and locking arrangements. The cabinet shall be painted both internally and externally with powder coated paint (shade : RAL 7032 SIEMENS GREY). The cabinet shall be dust and vermin proof with degree of protection IP 54. The cabinet shall be comprising with the following accessories:-
IN COMING :- (i) Four pole MCCB, 63 Amps with breaking capacity of 10 KA having adustable thermal and fixed magnetic release.
(ii) Aluminium bus bars for 3-phase & nuetral of current carying capacity up to 150 Amps dully mounted on FRP/DMC insulators and necessary drilling for connections and duly covered with heat shrinkable PVC sleeves of standard colour code.
OUTGOING :- (i) MCB TPN 40 A 10 KA -01 No
(ii) Contractor-01 Nos
(iii) Digital Ammeter, Volt Meter-01 Set
(iv) 200 W LED Flood Light, Make :- LUKER Cat No:LFL200 the driver of the fixture -09 Nos or eqquivalent approved make.
(v) LED Aviation Light single dome LED type Make: Bajaj / or equivalent approved make ; 02 Nos
Supply and Fixing LED Flood Light 1 x 50 W with integral driver with heat resistant well glass complete all as specifed and as directed. Cat Part No- LUCKER LFL50 / Bajaj / CG
Supply and lay LT UG cable, XLPE insulated armoured, heavy duty aluminium conductor multistranded, 1100 volts grade, of 16 Sqmm , 4.0 core cross sectional area laid in trenches / fixing on walls / poles or passing through GI pipe including connecting up with suitable lugs, nuts and bolts wherever required and testing complete all as specified and as directed.
Supply and lay LT UG cable, XLPE insulated armoured, heavy duty aluminium conductor multistranded, 1100volts grade, of 10 Sqmm , 2.0 core cross sectional area laid in trenches / fixing on walls / poles or passing through GI pipe including connecting up with suaitable lugs, nuts and bolts wherever required and testing complete all as specified and as directed.
Supply and fixing Metal flush box 6 module for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover including all accessories and necessary work for fixing like welding screws, clamps etc. on iron channel /angle / wall surface etc including painting the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Supply & fixing Switch piano, flush type single pole, one way 5 Amp complete all as specified and as directed.
M&L for earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised earth strip 32X6 mm dia connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI earth Strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel, wire gauge, 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of Schedule Part-I complete all as specified and as directed.
Supply, Installation, Testing & commissioning of outdoor type Panel Board platform mounted (with bolts and nuts) panel size 1.0 mtr x0.9 mtr x 0.2 mtr and made out of 3.15 mm thick CRCA MS sheet with front side openable . All door should have neaprene rubber gasket and locking arrangements. The cabinet shall be painted both internally and externally with powder coated paint (Shade : RAL 7032 SIEMENS GREY). The cabinet shall be dust and vermin proof with degree of protection IP 54 The cabinet shall be comprising with the following accessories:-
IN COMING (a) Four pole MCCB, 63 Amps with breaking capacity of 16KA having adustable thermal and fixed magnetic release. (b) Aluminium bus bars for 3-phase & nuetral of current carying capacity up to 200Amps dully mounted on FRP/DMC insulators and necessary drilling for connections and duly covered with heat shrinkable PVC sleeves of standard colour code, (c) Digital Time Switch ASTRO -01 Nos OUTGOING (a) MCB TP 63 A 10 KA -02 Nos, (b) MCB SPN 32 A 10 KA - 02 Nos (c) Digital Ammeter & Voltmeter - One Set
S&F of MCB DB SPN 8 way with copper bus bar & neutral link double door type to be fixed in the wall including connections complete all as specified and as directed.
S&F MCB SPN 6 to 32A, 10KA rupturing capacity complete all as specified and as directed.
S&F MCB SP 6 to 32 A 10 KA rupturing capacity complete all as specified and as directed.
M&L for sub main wiring complete as specified with 1100 volts grade 4.0 Sq.mm. (nominal area) single core FRLS Grade PVC insulated unsheathed cable multi-stranded copper conductor drawn through and rigid non-metallic PVC conduite suitable size with all necessary fittings, surface in walls / roof / floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete all as specified and directed. Note :- (I) Three runs of wire and one run of conduit with necessary accessories will be measured as one unit length. (II) The wiring shall be done strictly by AS PER IS CODE.
Excavation in trenches not exc 1.50 mtr wide and not exc 1.5 mtr depth and getting out in soft / loose soil complete all as specified and as directed .
M&L for road cutting not exc 1.50 mtr wide and not exc 1.5 mtr depth and getting out in road cutting (bitumen road) / PCC hard standing etc complete all as specified and as directed .
M&L for Plain cement concrete 1:2:4 type B-1 mix using 20 mm graded aggregate for filling in road cutting / hardstanding including necessary form work with fair finished surface complete all as specified and as directed .
Supply and filling river sand to the full width of trenches for protection of cables including spreading and punning down including watering consolidation complete all as specified and as directed .
Supplying and laying bricks common burnt clay building bricks, sub-class ‘B’ designation 75 laid in trenches across the trench over the cable as cable protection complete all as specified and as directed .
M & L for Boring of holes under road, pavement, hard standing by using trenchless technology , using ultra sounding technique and necessary machine and inserting GI pipe of 100 mm. complete all as specified and as directed . Note :- Pipe will be measured and paid separately under relevant item of Schedule 'A'.
M&L for Tubes, 'light grade' galvanised 100 mm dia, with all fittings and fixed complete to walls and ceilings or laid in floors / trenches / pole etc complete all as specified and as directed.
M&L for Tubes, 'light grade' galvanised 40 mm dia, with all fittings such as socket, elbow,bend etc and fixed complete to walls and ceilings or laid in floors / trenches / poles etc complete all as specified and as directed.
POWER CONSTRUCTION COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .