| 1 | L1₹20.7 LAccepted-AOC MEERA SADAN ROAD NO 3 NEAR WAXPOL FACTORY ANAND BIHAR BOOTY MORE JHARKHAND | JHARKHAND | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹21.3 L+₹47,151.01 (2.26%)Rejected-Finance | L2 | Rejected-Finance Quoted rate more than L1 | |
| 3 | L3₹23.2 L+₹2.3 L (11.1%)Rejected-Finance SANDHYA NIWAS MAGADH COLONY ROAD NO 03 SHERGHATI ROAD PS MAGADH MEDICAL COLLAGE DIST GAYA PIN 823001 BIHAR | GAYA | BIHAR | 823001 | L3 | Rejected-Finance Quoted rate more than L1 | |
| 4 | L4₹23.8 L+₹2.9 L (13.9%)Rejected-Finance HARINAGAR BEHIND MAHESHWARY MARKET PO TATISILWAI DIST RANCHI PIN 835103 | RANCHI | JHARKHAND | 835103 | L4 | Rejected-Finance Quoted rate more than L1 | |
| 5 | L5₹24.1 L+₹3.2 L (15.5%)Rejected-Finance | L5 | Rejected-Finance Quoted rate more than L1 |
| Sl No | Description | Qty | Unit | M/s Kundu Enterprises L7 | M/S SURYA BUILDERS L3 | MR ENTERPRISES L1 | universal enterprises L4 | M/S RITESH YADAV L6 | BHARAT ELECTRICAL & ELECTRICAL WORKS L5 | M/S RAMOTAR SAHU L2 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Complete removal of all existing roof treatment from RCC roof including old hussion felt, tiles etc and preparation of surface with wire brush and cleaning with water complete all as directed. | 490 | Sqm | 30 ₹14,700 | 5 ₹2,450 Lowest | 10 ₹4,900 | 30 ₹14,700 | 20 ₹9,800 | 10 ₹4,900 | 5 ₹2,450 Lowest |
| 2.00 | M&L for 40 mm thick PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate to roof , floor, chajja, RCC shelves etc at water retaning surfaces with WPC and make proper good slope as directed (Note-WPC will be measured and paid seprately) | 20 | Sqm | 300 ₹6,000 | 250 ₹5,000 | 150 ₹3,000 | 210 ₹4,200 | 290 ₹5,800 | 100 ₹2,000 Lowest | 150 ₹3,000 |
| 3.00 | M&L for preparation of concrete roof surfaces and applying 10mm thick plaster in CM 1:4 and finished the surface even and smooth without using extra cement complete all as specified and directed. | 490 | Sqm | 170 ₹83,300 | 130 ₹63,700 | 130 ₹63,700 | 210 ₹1,02,900 | 105 ₹51,450 | 110 ₹53,900 | 100 ₹49,000 Lowest |
| 4.00 | Supply only liquid water proofing compound. ISI Marked | 16.7 | Ltr | 190 ₹3,173 | 250 ₹4,175 | 60 ₹1,002 | 250 ₹4,175 | 80 ₹1,336 | 200 ₹3,340 | 30 ₹501 Lowest |
| 5.00 | M&L for applying a coat of bitumen primer @ 0.3L/sqm on roof surfaces. complte all as specified and directed | 490 | Sqm | 30 ₹14,700 | 50 ₹24,500 | 40 ₹19,600 | 50 ₹24,500 | 20 ₹9,800 Lowest | 20 ₹9,800 Lowest | 50 ₹24,500 |
| 6.00 | M&L for applying 3mm thick APP modified polymeric membrane over the bitumen coat surface weight not less than 3kg/sqm and over lap 100mm and sealed by torch application as per manufacture insteructions complte all as specified and directed | 490 | Sqm | 325 ₹1,59,250 | 300 ₹1,47,000 | 300 ₹1,47,000 | 360 ₹1,76,400 | 335 ₹1,64,150 | 300 ₹1,47,000 | 250 ₹1,22,500 Lowest |
| 7.00 | M&L for applying two coats aluminium paint over bituminous surface of membrane. complte all as specified and directed | 490 | Sqm | 65 ₹31,850 | 50 ₹24,500 | 40 ₹19,600 | 50 ₹24,500 | 30 ₹14,700 Lowest | 60 ₹29,400 | 50 ₹24,500 |
| 8.00 | M &L for providing cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) in lintel upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, stringcourses lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones bed plates,kerbs incl weathering slightly rounded or chemfered angles and throating as directed. | 1.25 | Cum | 5,000 ₹6,250 | 5,000 ₹6,250 | 4,000 ₹5,000 | 6,000 ₹7,500 | 5,500 ₹6,875 | 3,800 ₹4,750 | 2,500 ₹3,125 Lowest |
| 9.00 | Taking down eaves gutters and rain water pipes (any size or patterns) including all fittings,heads,shoes,bends,swan-necks etc complete all as directed by Engr-in-Charge. | 60 | RM | 10 ₹600 | 10 ₹600 | 5 ₹300 Lowest | 15 ₹900 | 10 ₹600 | 10 ₹600 | 5 ₹300 Lowest |
| 10.00 | S&F PVC(SWR) pipe 110 mm dia single socketed in any length with rubber ring joints, fixed to wall with and including stack and clamp complete all as specified and as directed by Engr-in-Charge. | 50 | RM | 260 ₹13,000 Lowest | 350 ₹17,500 | 280 ₹14,000 | 270 ₹13,500 | 280 ₹14,000 | 300 ₹15,000 | 400 ₹20,000 |
Tender Value
₹34.1 L
EMD Value
₹68,160
Closing Date
9 Feb 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE DIPATOLI
GARRISON ENGINEER MILITARY ENGINEER SERVICES DIPATOLI CANTT PO- HOTWAR RANCHI Pin- 834012
SPL REPAIRS TO OTM BLDG NO P-354 (HOT COLD ANCY SEC) OF FD WKSP (EME BN) AT DIPATOLI POCKET UNDER GE DIPATOLI
2026_MES_749100_1
8000/2161/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
DIPATOLI
As per tender documents
6 documents required · 6 mandatory
₹500
GE DIPATOLI
₹68,160
Yes
16 Mar 2026
19 Jan 2026
16 Feb 2026
19 Jan 2026
9 Feb 2026
2 Feb 2026
Complete removal of all existing roof treatment from RCC roof including old hussion felt, tiles etc and preparation of surface with wire brush and cleaning with water complete all as directed.
M&L for 40 mm thick PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate to roof , floor, chajja, RCC shelves etc at water retaning surfaces with WPC and make proper good slope as directed (Note-WPC will be measured and paid seprately)
M&L for preparation of concrete roof surfaces and applying 10mm thick plaster in CM 1:4 and finished the surface even and smooth without using extra cement complete all as specified and directed.
Supply only liquid water proofing compound. ISI Marked
M&L for applying a coat of bitumen primer @ 0.3L/sqm on roof surfaces. complte all as specified and directed
M&L for applying 3mm thick APP modified polymeric membrane over the bitumen coat surface weight not less than 3kg/sqm and over lap 100mm and sealed by torch application as per manufacture insteructions complte all as specified and directed
M&L for applying two coats aluminium paint over bituminous surface of membrane. complte all as specified and directed
M &L for providing cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) in lintel upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, stringcourses lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones bed plates,kerbs incl weathering slightly rounded or chemfered angles and throating as directed.
Taking down eaves gutters and rain water pipes (any size or patterns) including all fittings,heads,shoes,bends,swan-necks etc complete all as directed by Engr-in-Charge.
S&F PVC(SWR) pipe 110 mm dia single socketed in any length with rubber ring joints, fixed to wall with and including stack and clamp complete all as specified and as directed by Engr-in-Charge.
S&F PVC(SWR) bends any radius 110 mm dia complete all as specified and as directed by Engr-in-Charge.
Demolition of brick work or rubbled stone masonry including all qoins arches , pillars etc built in cement mortar. complte all as specified and directed
M &L for brickwork with fly ash modular bricks, strainght or curved on plan exc 6M mean radious radius built in Cement mortar 1:6 complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complte all as specified and directed
M&L for rendering 15 mm thick in cement mortar 1:4 on wall of brick work or concrete surface, finished fair and even all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on wall of brick work or concrete surface, finished fair and even all as specified and directed.
M&L for rendering 5 mm thick in cement mortar 1:3 on ceiling of brick or concrete surface, finished fair and even all as specified and directed.
Material and labour for preparation of OLD plastered surfaces of ceiling and applying three coats of white wash complete all as specified & directed.
Material and labour for preparation of NEW plastered surfaces of ceiling and applying three coats of white wash complete all as specified & directed.
Materials & labour for prepration of NEW plastered surface and finishing the surfaces of wall with wall putty and applying two coat of Oil Bound distemper over one Coat of Cement Primer of, any colour, complete all as specified & directed.
Materials & labour for prepration of OLD plastered surface and finishing the surfaces of wall with wall putty and applying two coat of Oil Bound distemper over one Coat of Cement Primer of, any colour, complete all as specified & directed.
Material & Labour for preparation of new plastered surfaces applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces complete all as specified & directed..
Complete removal and preparation of old plastered surfaces applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces complete all as specified & directed..
M&L for repair and rendering 10mm thick in CM 1 :3 on chajjas, facia, roof projection, column sides, beam bottom and sides including throating after removing cracked plaster and concrete including cleaning of viisible reinforcement and treating with cement slurry also necessary repair to cracked concrete if any with cement concrete 1:2:4 Type B-0 using 12.5mm graded aggregate including necessary scafolding work for double/single storey bldgs all as directed .
M & L for providing cement concrete type B1 1:2:4(20 mm graded stone aggregate) as in lintels upto 1.5m clear span, copings, bed plates (block),cills, steps and other bands, parapet and railing upto 60cm height. complete all as specified.
Taking down Rolling Shutter exc 10 Sqm but n.exc 18.00 Sqm each with shutter without taking of shutter from framed complete incl removing from site
S &F Steel rolling shutters,1.25 mm tk of laths with out ball bearing, as specified including top cover, an choring rod, Guide channel, hasp and staple and one shop coat of primer; erected in position as indi cated, complete: push pull or manual type and incl Safety lever locks mild steel with 4 levers for rolling shutters-2 Nos complete all as specified and directed.
S &F Steel rolling shutters,1.25 mm tk of laths with out ball bearing, as specified including top cover, an choring rod, Guide channel, hasp and staple and one shop coat of primer; erected in position as indi cated, complete: but gear operated type with bevel gear box and crank handle and incl Safety lever locks mild steel with 4 levers for rolling shutters-2 Nos complete all as specified and directed.
S&F of Ball bearing for rolling shutters complete all as specified and directed.
M&L for preparing the new surface of any description not otherwise described over 10 cm width or girth on steel surface and applying 02xcoats of synthetic enamel paint all as specified
Demolition of cement concrete in ground floors and paving exc 15cm thickness(below or above ground level) all as directed.
M&L for 75 mm thick cement concrete1:3:6 type C2,using 40 mm stone aggregate finished even & smooth without using extra cement as in plinth protection etc. complete all as specified & directed.
M&L for 40 mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate), as in floors including finishing cement concrete surface even and smooth without using extra cement complete all as specified & directed.
Supply only glass dividing strips 3mm thick and 38 mm Wide complete all as specified and directed.
M&L forCement concrete work in pavement/hard-standing of flexural strength 40kg/per square centimetre in field using400 kg of cement per cubic metre,thickness of concrete 25 cm or less complete all as specified and directed.
M&L for Forming Construction joint 30mm deep x 10mm wide filled with sealing compound. Grade 'A' complte all as specified and directed
M&L for Forming Contraction (Dummy) joints 65mm deep x 10mm wide,filled with sealing compound grade 'A' complte all as specified and directed
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safecustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. etc complete all as directed.
Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good the disturbed surfaces of walls,floors roofs etc complete all as directed.
Taking down Old/ Unserviceable MCB DBs SPN/TPN/ Main Switches by disconnection of electric connection including old unsv MCCBs,MCBs, isolators etc and making good to distrubed surface complete all as specified and directed.
M&L for point wiring for One light/Fan point controlled by one five amps one way single pole switch complete with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade , drawn through PVC concealed conduit 20/25 mm dia on wall/ceiling ,including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes ,cromium plate screw as suitable size for mounting of switch & scoket including 1.5 sqmm size pvc insulated unsheathed copper conductor to common earth and connecting to earth dolly complete all as specified and directed. Note: The rate quoted is deemed to be included for Penolic sheet (Hylem) and steel terminal box , cutting of hylem sheet for fixing of switch and scoket including cutting chases in wall making good to disturbed surface and matching with existing surfaces.
All as per Ser item No 41 here-in-before but one 3 Pin Socket out let 5 Amps on the same board.
All as per Ser item No 41 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board.
All as per Ser item No 41 here-in-before but point wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly.
S&F Switch modular 1 way 6 Amps single pole complete all as specified & directed.
S&F Switch modular single pole , one way 16 Amps complete all as specified and directed.
S&F Socket modular 2/3 pin combined 6 Amps complete all as specified and directed.
S&F Socket modular 2/3 pin combined 6/16 Amps complete all as specified & directed.
S&F Ceiling rose, 3 terminal PVC/polycarbonate complete all as specified and directed.
S&F modular Fan step regulator 230 Volts single phase 120 watt, 2 module complete all as specified and directed.
M&L for submain complete with 2x4 sqmm, single core, multi stranded copper conductor , PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn in with and including PVC concealed conduit 20/25 mm dia as per site requirement along walls/ceiling etc including 4 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire(Phase red colour,neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs (ii) painting over surface conduit to be done to match with walls/ceiling existing surfaces. (iii) Two run of wire (phase & neutral) and one run of wire (earth conductor) be measured as one length)
Supply and fix MCB DB SPN 8 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed.
Supply and fix MCCB DB VTPN 4 way with metal door suitable for Provision of incommer and out going MCCBs/MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed.
Supply and fix in replacement MCCB 100 Amp 415 volts 16kA 4 pole complete all as specified and directed.
S&F in replacement of MCB SP 6 to 32 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
S&F in replacement of MCB DP 40 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles.
S&F in replacement of isolator DP 63 Amps 'C' Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
S&F in replacement of LED tube light fitting 20 watt 230 Volt decorative ultra slim linear LED Lighting with aluminium housing & integrated electronic driver , including all internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F wall monted fan AC single phase, 230Volts of size 450 mm sweep, WM SSTORM 2 (Metal blade & Base) complete including necessary electric connection complete all as specified and directed.
S & F Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V. 1200 mm sweep, Min air dilivery 210 CFM With service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete including taking down old fan and deposited to store yard as specified and directed. Note:- MES No. shall be written by the contractor on fan and rates shall be deemed to be included in quoted rates
S&F in replacement of building LED security light fitting 25 Watt in aluminium pressure die cast aluminium housing with high power LED as lightning sourse and lens embedded PC Cover having IP 65 protection and impect resistance of IK07 with 10 KV Built in super protection device. luminaire with high power LED as light source including suitable size of GI bracket fixed with two Nos GI clamp nut,bolt,washer etc complete all as specified and directed at site.
Supply, Laying on replacement ,connecting, testing and commissioning of XLPE LT UG cable of size 35 sqmm 3 1/2 core PVC insulated and sheathed armoured heavy duty cable 1100 V grade with alu conductor cable all as specified & directed.
Excavation in trenches in loose/soft soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables, poles/stays and struts etc and getting out including trimming sides and forming bottom surface complete, all as directed.
Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as directed.
Returning & filling in including spearing, leveling watering and well ramming in layers not exc 25cm thick. complete all as directed
Supply and Spread dry river sand for cable cushioning in trenches all as specified and directed. Note : Punned down thickness shall be considered for measurement .
Supply and lay burnt bricks sub class ‘B’ old size laid dry in trenches across the cable protection all as specified and as directed
M &L for GI Earthing complete with GI earth plate electrode 60cm x 60cm x6 mm buried directly in ground verticvally to size of earth pit not less than 0.90x 0.90 x 2.25 mtr below ground level with top edge of the plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised earth strip of size 32 x 6 mm, 7.5 mtr long (Min) by means of brazing nuts, bolts, check nuts, & washers ,testing of completion (drawn in earth strip protection pipe light gade GI of size 40 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSR Part - I filling with charcoal dust , and common salt , including necessary excavation and earth work in any type of soil ,perforated watering pipeof size 15 mm dia,funnel with wire mesh,earth strip protection pipe light grade PCC chamber 1:3:6 type C1 (for even finish on both the faces) and RCC cover 1:2:4 Type B1,450 x450 x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed by EIC Note : (i) 7.5 RM GI earth wire deemed to be included in quoted rates beyond 7.5 RM wire shall be measured and paid separately. (ii) Earth resistance of earth pit should be not more than 02 Ohms on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (iii) Rate quoted by the tenderer is deemed to included salt & Charcoal upto & above 450 mm (Min) top of GI Plate.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
BOQ_838912.xls
BOQ • 0.46 MB
TENDER2161.pdf
Tender Documents • 1.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .