Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹11.9 LAdmitted-Finance | -17.99% | ₹11.9 L | L1 | Admitted-Finance |
| 2 | L2₹12.0 L+₹3,488.91 (0.29%)Admitted-Finance | -17.75% | ₹12.0 L+₹3,488.91 (0.29%) | L2 | Admitted-Finance |
| 3 | L3₹12.9 L+₹93,328.39 (7.83%)Admitted-Finance | -11.57% | ₹12.9 L+₹93,328.39 (7.83%) | L3 | Admitted-Finance |
Tender Value
₹14.5 L
EMD Value
₹29,080
Closing Date
1 Jun 2026, 6:00 pmClosed
EXEN PHED DIVISION KHETRI
EXEN PHED DIVISION KHETRI
Construction and Commissioning of 200 KL Capacity GLSR and Demolishing of old damaged GLSR at Village Sefraguwar of Rural Sub Division Khetri, Division Khetri
2026_PHCJA_561069_1
NIB09/2026-27
Open Tender
Civil Works - Water Works
Percentage
60 days
KHETRI
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
EXEN PHED DIVISION
₹29,080
Yes
30 Jun 2026
20 May 2026
2 Jun 2026
20 May 2026
1 Jun 2026
20 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Construction of RCC Dome type Ground Level Service Reservoir (GLSR) of following capacity as per the Scope of work and Technical specifications, consisting of the following main activities: - | - | - | - | - |
| 2 | a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction.
b) Excavation in all types of soil, PCC below foundation & all RCC Work.
c) All the GLSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.
d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall giving.
e) Successful hydro test and water tightness test as per I.S. code.
f) Providing and applying three coats of anti-carbonation paint on the roof Slab.
g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.
h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from top bottom Slab inside container. Providing and fixing water level indicator (Float type). | - | - | - | - |
| 3 | i) Providing and fixing MS ladder from ground to top slab with safety cage.
j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.
k) Providing and fixing of 150mm wide water bar for the construction joints in the container.
l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipe of the reservoir.
m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. | - | - | - | - |
| 4 | Rates for RCC GROUND LEVEL SERVICE RESERVOIR SEISMIC ZONE-II & III and SBC18T/sqm | - | - | - | - |
| 5 | 200 KL capacity | 2,00,000 | Litre | 5.33 | ₹10,66,000 |
| 6 | Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. | - | - | - | - |
| 7 | 100 mm | 25 | Mtr | 1,914.41 | ₹47,860.25 |
| 8 | 200 mm | 10 | Mtr | 3,601.69 | ₹36,016.9 |
| 9 | Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work)
Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. | - | - | - | - |
| 10 | 100 mm | 50 | RMT | 1,240.68 | ₹62,034 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.52 MB
Tendernotice_2.pdf
PDF • 3.57 MB
BOQ_998593.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .