Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.6 LAccepted-Finance DOOR NO 43 2 BESIDES VIZAG DEFENCE ACADEMY 104 AREA KAPPARADA VISAKHAPATNAM 530013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | L1 | Accepted-Finance OK | |
| 2 | L2₹21.8 L+₹1.2 L (5.93%)Accepted-Finance 1 6 620 CHAITANYAPURI INDRA NAGAR DILSUKHNAGAR HYDERABAD TELANGANA 500060 UDYAM TS 09 0007870 37AAEPO0535A1Z8 B 36AAEPO0535A1ZA R MSME STATUS AS VERIFIED | RANGA REDDY | TELANGANA | 500060 | L2 | Accepted-Finance OK |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
3 Jul 2023, 6:00 pmClosed
GE (UTILITY) SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
REPAIR AND MAINTENANCE OF DG SETS, AMF PANELS, APFC PANEL AND CONNECTED ALLIED WORKS UNDER AGE E/M NO 1 OF GE (U) SECUNDERABAD
2023_MES_600397_1
GE (U)/SEC/TOKEN/15 OF 2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SECUNDERABAD
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (UTILITY) SECUNDERABAD
₹60,000
Yes
1 Aug 2023
2 Jun 2023
10 Jul 2023
2 Jun 2023
3 Jul 2023
16 Jun 2023
Amount
M&L for Maintenance of DG set and carrying out ‘B’ check and replacement of ‘B’ check kit filters such as Oil filter, by pass filter, fuel filter,CR element and CR plates complete with ‘O’ rings and draining of Engine oil and topping up with the new engine oil complete testing all as specified and directed by the Engineer-in-Charge for the following capacity DG sets:- Note :- (i) Engine oil shall be measured and paid separately (ii) Labour & transportation shall be arranged by contractor,quoted rate deemed to be inclusive in the unit rate. Make: KIRLOSKER/ CUMMINS /GREAVES/ GREAVES COTTON/ASIATIC/ RUSTON (a) up to 35 KVA DG Set
125 KVA DG Set
200 KVA to 250 KVA DG Set
Attending the breakdown of any capacity/make DG Sets, AMF Panels, by Technician & helper for checking all components and rectify the fault and give report to concern JE complete all as directed by Engineer-in-charge. Note :- Spare Parts for rectify the fault is measured and paid seperately.
M&L for Renewal/ repairs of unserviceable automatic voltage regulator (AVR) upto 125 KVA DG set including all spares, testing all as specified and directed by Engineer-in-Charge. Make:- As per OEM approved make.
M&L for Renewal/ repairs of unserviceable automatic voltage regulator (AVR) above 125KVA and upto 250 KVA DG set including all spares, testing all as specified and directed by Engineer-in-Charge. Make:- As per OEM approved make.
M&L for Dismantling of exhaust pipe of the DG set by unscrewing nuts and bolts and taking down the pipe with muffler removing the burnt out asbestos rope and well wrapping with new aluminium metal cladding with glass wool including cleaning the silencer, and fixing the same in its original position complete all as directed by Engineer- in- Charge for the following capacity DG Sets. (a) up to 125KVA
Above 125 KVA to 250 KVA DG set.
M&L for Disconnecting all electrical connections from the unserviceable self starter of any make/ capacity model 24 volts and taking down the self starter and transporting to civil workshop for carrying out repairs, complete overhauling the system including replacing the unserviceable parts like bearings, carbon brushes, clutch plates etc & assembling including after repair refixing the self starter in its original position,making all connection as per DG Set OEM recomendation, testing and commissioning complete all as directed by Engineer-in-charge. Note:- Supply only Armature coil, field coil shall be measured and paid separately under relevant items of this Schedule.
Supply only Armature coil for self starter of any make, any capacity and any model 24 Volts including testing complete all as directed by Engineer-in-charge
Rewinding of field coil for self starter of 24 volts with fine enamelled copper conductor of same gauge with 'F' class insullation, size twins and weight with necessary insulating materials, guage of conductor suitablef any make, any capacity and any model complete all as directed by Engineer-in-charge.
M&L for Disconnecting all electrical connections from the unserviceable self starter of any make/ capacity model 12 volts and taking down the self starter and transporting to civil workshop for carrying out repairs, complete overhauling the system including replacing the unserviceable parts like bearings, carbon brushes, clutch plates etc & assembling including after repair refixing the self starter in its original position,making all connection as per DG Set OEM recomendation, testing and commissioning complete all as directed by Engineer-in-charge. Note:- Supply only Armature coil, field coil shall be measured and paid separately under relevant items of this Schedule.
Supply only Armature coil for self starter of any make, any capacity and any model 12 Volts, 180/200 AH complete all as directed by Engineer-in-charge
Rewinding of field coil for self starter of 12 volts with fine enamelled copper conductor of same gauge with 'F' class insullation, size twins and weight with necessary insulating materials, guage of conductor suitablef any make, any capacity and any model complete all as directed by Engineer-in-charge.
M&L for Disconnecting the oil cooler of capacity up to 125 KVA DG set of any make/ model from the existing locations duly removing of all mechanical connections and taking down the same for complete servicing opening the parts and cleaning thoroughly by using suitable cleaning material and acid and reassembling and refixing in its original position, testing and commissioning complete all as directed by Engineer-in-charge
M&L for Disconnecting the oil cooler of capacity above 125kVA to 250KVA DG set of any make/ model from the existing locations duly removing of all mechanical connections and taking down the same for complete servicing opening the parts and cleaning thoroughly by using suitable cleaning material and acid and reassembling and refixing in its original position, testing and commissioning complete all as directed by Engineer-in-charge
M&L for Renewal/ replacement of existing unserviceable air cleaning element inner and outer with necessary ‘O’ rings for the DG sets of following capacities as that of existing make and model complete all as directed by Engineer-in-charge. Make :OEM recomended (a) Upto 125 KVA DG Set
Above 125 KVA and up to 250 KVA DG Set
M&L for Disconnecting all the incoming and outgoing rubber hoses and draining out the water from the choked radiator assembly of the existing make and model and various capacities of DG sets and taking down the radiator assembly by unscrewing all mechanical/electrical connections from the existing mounting, transporting the same to civil workshop for carrying out servicing, opening the top and bottom covers of radiator assembly cleaning thoroughly the chocked pipe of the radiator by using chemical detergent, lime caustic soda, cotton etc., cleaning of all the deposited sediments in the pipes/tubes including arresting of leakage by means of soldering, brazing and transporting back to site and refixing the same in its original position with suitable size nuts, bolts and washers and Anti vibrating mounting(AVM) pads as required as per OEM recomendation etc., for the following DG sets all as specified and directed by Engineer-in-Charge: (a) Upto 125 KVA DG Set
Above 125 KVA and up to 250 KVA DG Set
M&L for Renewal of battery cable leads of copper conductor and with brass lugs terminal, for the 12V, 150/180 /200 AH batteries to self stater as that of existing size and length complete all as directed by Engineer-in-charge. Make : HAVELLS/POLYCAB/KEI/FINOLEX or equivalent as approved by GE.
S&F Automatic cut off type Battery Charger suitable for 12 V, up to 10 Amp Battery complete all as directed by Engineer-in-charge. Make SMPS/ Phonix
S&F Automatic cut off type Battery Charger suitable for 24 V, up to 10 Amp Battery complete all as directed by Engineer-in-charge. Make SMPS/ Phonix
M&L for Renewal/replacement of 'V' belts for the following capacity DG sets as per existing size and model complete all as directed by Engineer-in-charge. Make :FENNER/DUNLOP/PENTAGON/SHRIRAM or equivalent as approved by GE. (a) Upto 125 KVA DG Set
Above 125 KVA and up to 250 KVA DG Set
M&L for Renewal/replacement of fan belts for the following capacity DG sets as per existing size and model complete all as directed by Engineer-in-charge. Make : :FENNER/DUNLOP/PENTAGON/SHRIRAM or equivalent as approved by GE. (a) Upto 125 KVA DG Set
Above 125 KVA and up to 250 KVA DG Set
M&L for Renewal/replacement of Dynamo belts for the following capacity DG sets as per existing size and model complete all as directed by Engineer-in-charge. Make : :FENNER/DUNLOP/PENTAGON/SHRIRAM or equivalent as approved by GE. (a) Upto 125 KVA DG Set
Above 125 KVA and up to 250 KVA DG Set
M&L disconnecting & removing the unservicable DC wiring from DG set of any type/any make/any model/any capacity and rewiring with the same with suitable new copper wire to existing guage wire by providing flexible pipe including making all electrical connections as per OEM recomendation for satisfactory completion of job & checking of electrical/electronic spares working condtion and testing etc complete all as specified and directed. Note: The rate quoted deemed to be inclusive of new copper wire cost in the unit rate.
M&L for replacement of existing unserviceable water temperature gauge with new water temperature gauge for the DG set of any description inclduing making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engineer-in-charge. Make: MICHELIN/VOROLY/PSA/ DANFOSS or equivalent as approved by GE.
M&L for replaceemnt of existing unserviceable lubricant oil temperature gauge with new lubricant oil temperature gauge for the DG set of any capacity inclduing making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engineer-in-charge. Make: MICHELIN/VOROLY/PSA/ DANFOSS or equivalent as approved by GE.
M&L for replacement of existing unserviceable oil pressure gauge with new oil pressure gauge for the DG SET of any capacity inclduing making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engineer-in-charge. Make: MICHELIN/VOROLY/PSA/ DANFOSS or equivalent as approved by GE.
M&L for replacement of unserviceable solenoid switch with new solenoid switch 12volts for DG set of any make and any capacity inclduing making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engineer-in-charge. Make :- OEM recomended
M&L for replacement of unserviceable solenoid switch with new solenoid switch 24volts for DG set of any make and any capacity inclduing making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engineer-in-charge. Make : MICHELIN/VOROLY/PSA/ DANFOSS or equivalent as approved by GE.
S&F in repairs the following spare parts for any type/make of DG sets, as and when required by the department complete all as specified and directed. Make for item No 28 to 28.10:- OEM recommended
Starting/Ignition - key/button
Volt Meter 0-500V
S.D Valve assembly
Oil safety control
Water safety control
Water separator bowl 3247715
Radiator Metal Pipes
Supply and filling the new engine oil 20W/40 for toping up upto the required level complete all as directed by Engineer-in-charge. Make :- CASTROL/ INDIAN OIL/ SERVO
Supply and filling the new engine oil 15W/40 for toping up upto the required level complete all as directed by Engineer-in-charge. Make :- CASTROL/ INDIAN OIL/ SERVO
S&F in replacement of Line Voltage Monitors (LVMS) of existing make to DG set of 30 KVA to 250 KVA capacity listed parameters including testing complete all as specified and as directed. Make :- OEM recommended
Drain out the fuel from the fuel tank of DG set of capacity 400 Ltrs and above and keeping it in separate container safely, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank and welding/ brazing including one coat of synthetic enamel paint, refixing the tank in its original position, replacing the drain plug and PVC pipe, calibrating the fuel tank, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements complete all as directed by Engineer-in-charge.
Description all as per item No. 32 above but upto 250 Ltrs complete all as directed by Engineer-in-charge.
M&L for Removing of defective engine oil control pressure switch supply & fix new engine oil control pressure switch suitable for above 30 KVA to 250 KVA DG set complete all as directed by Engineer-in-charge. Make as per OEM Recommendation.
M&L disconnecting & removing the unservicable AC wiring from AMF panel of DG set of any type/any make/any model/any capacity and rewiring with the same with suitable new copper wire to existing guage wire by providing flexible pipe including making all electrical connections as per OEM recomendation for satisfactory completion of job & replacement of electrical/electronic spares and testing etc complete all as specified and directed. Note: (i) The rate quoted deemed to be inclusive of new copper wire cost in the unit rate. (ii) Electrical/Electrnoc spares shall be measured & paid separately under relevant items.
Supply only following spare parts :- Push buttons.
AMF Panel Hooter Make : L&T/SIEMENS/ABB/C&S or equivalent as approved by GE.
Earth fault relay. Make: OEM recommended
Over load relay. Make : L&T/SIEMENS/ABB/C&S or equivalent as approved by GE.
Over/Under voltage relay. Make : L&T/SIEMENS/ABB/C&S or equivalent as approved by GE.
Auxilary relays 12v/6Amps Make : L&T/SIEMENS/ABB/C&S or equivalent as approved by GE.
Single phase preventer, Make:minilec/GIC
Auxiliary Relays 24Volts / 6A Make : L&T/SIEMENS/ABB/C&S or equivalent as approved by GE.
PLC based AMF relay unit Make: OEM recommended
Low lube oil safety switch Make: OEM recommended
Booster Relay 24Volts / 10A Make: OEM recommended
Coolant temparature sensor Make: OEM recomeded
M&L for Removing the defective charging dynamo of capacity 24 Volt DC any make, model, any capacity and opening it, by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling lubricating of the rewinding the damaged winding of field coils with super enameled copper wire suitable to same existing size/guage & reconnecting the same, refixing back, in original position including making all necessary electrical/mechanical connections testing and commissioning complete all as directed by Engineer-in-charge.
M&L for Removing the defective charging dynamo of capacity 12 Volt DC any make, model, any capacity and opening it, by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling lubricating of the rewinding the damaged winding of field coils with super enameled copper wire suitable to same existing size/guage & reconnecting the same, refixing back, in original position including making all necessary electrical/mechanical connections testing and commissioning complete all as directed by Engineer-in-charge.
M&L for replacement of unserviceable spares for water manifold and Radiator spares above 30 and upto 125 KVA DG set for the following spares:- (a) Radiator rubber hoses.
Clamp for hump hose.
Hose clamps.
Hump hose.
M&L for replacement of unserviceable spares for water manifold and Radiator spares above 125 kVA and upto 250KVA DG set for the following spares:- (a) Radiator rubber hoses.
Clamp for hump hose.
Hose clamps.
Hump hose.
M&L for Inhibitor corrosion (coolant additive concentrate) required for top up (TVS Make) complete all as directed by Engineer-in-charge.
Supply and topping up of distilled water suitable for lead acid batteries of 12 volts complete all as directed by Engineer-in-charge.
S&F battery brass terminal and jelly complete all as specified and directed.
M&L for Renewal/Replacement of unserviceable batteries with maintenance free batteries of 180 AH, 12V including connecting to DG set complete all as directed by Engineer-in-charge. Make:- EXIDE or equivalent as appoved by GE.
M&L for Disconnecting all connection & remove the PT pump from engine and transport to OEM authorised service center and Calibration of PT pump for maximum efficiency by OEM Authorised Service center & replacement of PT Pump kit, gear gasket, etc in its original position by making all necessary connections complete whichever required under AGE E/M-I(U) AOR for smooth functioning of fllowing DG Set capacities complete all as directed by Engineer-in-charge (a) DG Set capacity above 30 KVA to 125 KVA
DG Set capacity above 125KVA to 250KVA
M&L for remove the fuel injection pump from the engine transport to an authorized service centre for service, calibration and to adjust by replacing the following un serviceable worn-out spares with new appropriate make minor spares and bringing and fixing to the engine and tune up for maximum efficiency all as specified and as directed for DG set capacity above 30 KVA and upto 125 KVA :- Note: Major spares required will be measured and paid seperately.
Supply only orfice for above above above 30 KVA and upto 125 KVA capacity DG set
Supply only Barrel and Plunger for above 30 KVA and upto 125 KVA capacity DG set
Supply only FIP Bearing for above 30 KVA and upto 125KVA capacity DG set
M&L for remove the fuel injection pump from the engine transport to an authorized service centre for service, calibration and to adjust by replacing the following unservicable worn-out spares with new appropriate make minor spares and bringing and fixing to the engine and tune up for maximum efficiency all as specified and as directed for DG set capacity above 125 KVA and upto 250KVA :- Note: Major spares required will be measured and paid seperately.
Supply only orfice for above 125 KVA and upto 250 KVA capacity DG set
Supply only Barrel and Plunger for 125 KVA and upto 250KVA capacity DG set
Supply only FIP Bearing for above 125 KVA and upto 250KVA capacity DG set
Supply and fix self starter Motor, 24 volts, Make LUCAS or its equivalent make approved by OEM of DG Set suitable for existing DG set above 82.5 KVA to 250 KVA including making all necessary electrical/mechanical connection as per recomendation of OEM of DG Set & dismantling/taking out old unserviceable self starter Motor from existing position complete all as directed by Engineer-in-charge
Supply and fix self starter Motor, 12 volts, Make LUCAS or its equivalent make approved OEM of DG Set suitable for existing DG set capacity up to 82.5 KVA including making all necessary electrical/mechanical connection as per recomendation of OEM of DG Set & dismantling/taking out old unserviceable self starter Motor from existing position complete all as directed by Engineer-in-charge
S&F Flexible Bellow suitable for up to 125 KVA Gen Set. Make as per OEM
S&F Flexible Bellow suitable for above 125KVA and up to 250 KVA Gen Set. Make as per OEM
M&L for Servicing of DG Set panel's indoor/outdoor type of any make/model/capacity, checking of switching ON/OFF & tripping system, Spring charge Motor working system,checking of all electrical mechanical components of AMF panel and Setting the same for proper working of Breaker, testing of operation manually and auto mode complete all as directed by Engineer-in-charge. Note:-All the mechanical parts are thoroughly cleaned by suitable cleaning agent & moving parts are properly lubricated
Supply and fix Coil of Power contactor of having capacity 400 Amps 4 pole 2NO +2NC complete all as specified and directed. Make:- L&T Cat part No. CS94195 or equivalent from HPL/Schneider as approved by GE.
Supply and fix Power contactor of having capacity 275 Amps 4 pole 2NO +2NC complete all as specified and directed. Make:- C&S Cat part No LC1 FDP1854AE or equivalent from HPL/Schneider as approved by GE.
Supply and fix Power contactor of having capacity 400 Amps 4 pole 2NO +2NC complete all as specified and directed. Make:- C&S Cat part No LC1 FDP3304AE or equivalent from HPL/Schneider as approved by GE.
Supply and fix Power contactor of having capacity MCX 43 400 Amps 4 pole 2NO +2NC complete all as specified and directed. Make:- L&T Cat part No. CS97025 or equivalent from HPL/Schneider as approved by GE.
Supply and fix Power contactor of having capacity MCX 33 200 Amps 4 pole 2NO +2NC complete all as specified and directed. Make:- L&T Cat part No. CS97021 or equivalent from HPL/Schneider as approved by GE.
MCCB 400 Amps, 4 pole, 415 Volts with rapturing capacity 50 KA adjustable magnetic and thermal settings. Make : - L&T Cat Part No. CM94103OOR1OG or equivalent from Havells/ C&G as approved by GE.
Supply,install, test, commissioning & run the DG set's Fly-wheel Ring of Fly-wheel Assembly of existing model,size suitable to DG Set of capacity up to 125 KVA including taking down old Unserviceable complete all as directed by Engineer-in-Charge.
Supply,install, test, commissioning & run the DG set's Fly-wheel Ring of Fly-wheel Assembly of existing model,size suitable to existing DG Set of capacity above 125kVA up to 250 KVA including taking down old Unserviceable complete all as directed by Engineer-in-Charge.
Disconnect the Radiator and kept aside safely and taking down the old unserviceable water pump from the existing engine of DG set any make/model, capacity up to 125 KVA supply and fixing of new water pump & kit,reassembling the same and refixing the pump to the engine of DG set, refixing Radiator and testing, including making all Electrical/mechanical connections,commissioning as per OEM recomendation complete all as directed by Engineer-in-charge.
Disconnect the Radiator and kept aside safely and taking down the old unserviceable water pump from the existing engine of DG set any make/model, capacity above 125KVA and up to 250 KVA supply and fixing of new water pump & kit,reassembling the same and refixing the pump to the engine of DG set, refixing Radiator and testing, including making all Electrical/mechanical connections,commissioning as per OEM recomendation complete all as directed by Engineer-in-charge.
Supply, Fix & test run the DG set after replacing Diesel feeder Pump of existing model,size suitable to DG Set of capacity 35 KVA to 250 KVA including taking down old unserviceable complete all as directed by Engineer-in-Charge.
M&L for disconnecting all electrical & mechanical connections,Dismantle the Engine (make KIRLOSKER/ CUMMINS /GREAVES/ GREAVES COTTON/ASIATIC/ RUSTON) from 35KVA to 250 KVA DG set capacities located at various location under AGE E/M-I(U) and transported to OEM Authorised service center for complete overhauling, replacing the following unservicable worn-out spares with new appropriate make minor spares & major spares (minor spares- up to Rs 2500/Each), after assembling the spares the Engine again shfted to original existing place and reassembled to alternator& radiator,AMF panel/Electrical panel board of DG set complete testing, commissioning all as per OEM recomendation and as directed by Engineer-in-charge. Note: -(i) Major Spare parts shall be measured and paid separately. (ii) The quoted rate deemed to be inclusive of Manpower, Crane charges for transporting engine to workshop and back after repairs
Gear fuel Pump
Total Gaskets Set
Core & cooler set
Shaft rocker arm
Oil seal
Ball Bearings set
Main Bearings set(STD)
Material and labour for repairs to Alternator of following DG Set, transporting the same to the OEM authorised service center/work shop and carrying out the repairs such as taking out the burnt out winding and rewinding the alternator with copper wire of same guage turns and weight, checking of commentator, brushes complete and refixing the same in its existing position after transporting back to the site and connecting up electric connections with suitable lugs complete and testing all as specified and directed. Note: Copper winding material will be measured and paid seperately under relevant Item
Upto 125 KVA capacity
Above 125 KVA and upto 250 KVA Capacity.
Supply only High conductivity copper conductor winding material including necessary insulation material as requred for complete all as specified and directed by Engineer-in-Chrage
Supply & lay heavy duty PVC insulated multi stranded Copper Conductor 4 core of size 2.5 Sqmm, 230 volts, 50 HZ complete all as specified and directed.
M&L taking down defective Turbo Charger Assembly duly disconnecting the mechanical and electrical connections from DG Set, opening and thoroughly checking to carry out repairs complete to the Turbo Charger Kit and spares as required at site including any mechanical and reassembling and refixing the turbo charger assembly to its original position and reconnecting the same for the following capacities including testing complete all as specified and directed.
DG Set of capacity upto 125 KVA
DG Set of capacity above 125 KVA and up to 250 KVA
M&L for calibration of water pump complete, overhauling, replacing of gaskets, nuts, washers etc and reassembling the same and refixing the pump to the engine and testing including taking down the old unservicable water pump of any capacity of DG set from the engine and taking it out side work to workshop, complete all as specified and directed:-
DG Set of capacity upto 125 KVA KVA
DG Set of capacity above 125 KVA and up to 250 KVA
M & L for dismantling & disconnecting all connection of the cylinder heads from diesel engine and sent to OEM authorised Service center for calibration and repairs by replacing the spares such as Valves, Value Guides, Valves seats and repairs kit and re-assembling to its original position with necessary Engine cylinder head gasket and O rings for the following capacities including testing complete all as specified and directed:-
DG Set of capacity upto 125 KVA
DG Set of capacity above 125 KVA and up to 250 KVA
M & L for maintenence free safe earthing electrode (SEE) designed pipe in pipe technology, set of 3 Nos earth pit duly inter connected with copper earth strip 25 mm x 3 mm, each earth pit having outer pipe of size 76.3mm dia and inner pipe of size 42.4 mm dia, each GI pipe have 2 mtr long duly zinc and alloy coated having zinc coating (80-100) microns to whole length of pipe and alloy coating 250-300 micron to upper 300mm length of pipe, inside filled with crystal conductive compound (CCC) having anti corrosive and conductive properties to provide annular space of earth electrode and external black fill compound two bag of 25 kg mixed with soil all arround the earth pipe for retaining moisture, reduce the soil resistivity and dissipation of fault current, connected to earthing test point including excavation, earth work, PCC pit, RCC cover 50 mm thick, lifting rod 8mm dia, GI protection pipe 40 mm dia light grade for protection of inter connecting earthing strip from mechanical protection and testing on completion, complete all as specified and directed.
Supply and fixing Copper Strip 20 x 3.15 mm with saddles and fixing screws etc for roof conductors and down conductors above ground to interconnect the earth pit to equipment room Note: (a) Copper sockets and connector bolts nuts washers and drilling holes shall deemed to be included in the unit rate quoteed. (b) Excavation and earth work where ever required shall be carried out in this item only (c) On testing after completion of earthing earth restiance shall be less than 1 Ohm complete all as specified and directed by Engineer -in - charge
Supply & lay Galvanised Iron tubing 40mm bore, light grade in protection of cable at road crossing/hard standing/pole protection fixed with MS clamps of size 40 X 4 mm, nut bolts and washer as per site requirement including taking down old unserviceable pipes complete all as specified and directed.
M&L preparation of old painted surfaces of the DG Sets of 35 KVA to 125 KVA capacity including degreasing and spray painting the DG sets with one coat of synthetic enamel paint of approved colour and writing SM/MES No including painting on concrete surfaces of foundations with black paint complete all as specified and directed.
M&L preparation of old painted surfaces of the DG Sets of the above 125 KVA and up to 250 KVA capacity including degreasing and spray painting the DG sets with one coat of synthetic enamel paint of approved colour and writing SM/MES No including painting on concrete surfaces of foundations with black paint complete all as specified and directed.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area laid in trenches / duct or fixed to wall / passing through pipe on pole with suitable size cable glands, crimping type cable lugs for stranded aluminum conductor of following sizes complete all as specified and directed :-
4 Core X 25 Sqmm
3.5 Core X 95 Sqmm
3.5 Core X 120 Sqmm
3.5 Core X 240Sqmm
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in hard / dense soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushion after punning down shall be measured for payment.
Supply and Lay reinforced precast concrete cable cover LV, Type I,flat, size 250x150x40 mm complete all as specified and directed.
M&L cutting of road/hard standing upto a size not exceeding 20 cm in width and not exceeding 60 cm in depth for laying of LT UG cable/protection pipe line making good the disturbed portion so as to match existing finishing with PCC 1:2:4 type B1/cement mortar in CM (1:2) complete all as specified and directed
M&L for double sided Glow sign board of size as directed by Engineer-in-Charge showing location/details of power house/ tech area and writing of letters (block, roman, italic) on flex sheets and the sides of perimeter covered with PGI Sheet 24 SWG, properly overlapped or mounted on MS iron 35x35x5 mm 'H' frame with cross brasing including fixing of LED 4 feet 18 W inside of the each board with required point wiring with suitable size of stranded copper conductor, PVC insulated FR cables complete all as specified and directed
M&L for preparation of old painted surfaces for outdoor/indoor Amf panel/LT Panel of any size with applying two coat of synthetic enamelled grey paint after removing all dust & rust and paint shall confirm to IS 2032 complete all as specified .
S&F in replacement of microprocessor based control unit suitable to DG set of any capacity with all listed parameters as per recomendation including testing complete all as specified and directed. Make : KIRLOSKAR/LUMINUS/GREAVES/ ASHOK LEYLAND or equivalent as approved by GE.
S &F Door hinges of any capacity of DG Sets as suitable for existing one as specified and directed. Make KIRLOSKAR/LUMINUS/GREAVES/ ASHOK LEYLAND or equivalent as approved by GE.
S &F Door lock of any capacity of DG Sets as suitable for existing one as specified and directed. Make KIRLOSKAR/LUMINUS/GREAVES/ ASHOK LEYLAND or equivalent as approved by GE.
Supply only cotton waste for cleaning for DG Set and surrounding area complete all as specfied and directed. Make : KIRLOSKAR/LUMINUS/GREAVES/ ASHOK LEYLAND or equivalent as approved by GE.
Repair/maintenance, excluding major spares but including regualr maintenance of the Automatic Power factor correction panel capacity up to 100 KVARs and up 8 stages installed at various locations at CDM area including carrying out complete maintenance/repairs as required of all the sub systems viz. based control panels, feeder pillar, APFC relay, Power capacitor bank, Power contactors, Control wiring, Monitoring CT, MCBs/MCCBs for isolation (with all the accessoires) any breakdown maintenance and replacement of unserviceable parts, refixing of old serviceable parts/new parts if any project completion and trouble shooting responsibility also lies with contractor including following provisions complete all as specified and directed. Notes:- (i) Rate quoted by tenderer is deemed to be inclusive of checking of system fortnightly, repavement of defective control wiring, small part such as Push button, lugs any auxilary contatct,auto selctor switch etc and necessary servicing repair by expert technician and register will be maintaned for the same. (ii) The scope of work includes the labour charges required for removing, repairing, refixing, carrying out electrical termination, capacitors bank, APFC relay, power contactor, contol CT, MCBs/MCCB and fixing/installing/testing and commissioning the complete system. (iii) capacitors bank, APFC relay, power contactor, control CT, MCBs/MCCB shall be measured and paid seperatly
Supply only power factor correction capacitor, 5 KVAR, heavy duty 440 volts 50 Hz complete including taking down old unserviceable capacitor complete all as specified and directed. Make : L&T or equivalent in HPL/Standard/Havells / Schneider as approved by GE.
All as per item No 88 here in before but 10 KVAR Capacitor Bank
All as per item No 88 here-in-before but 20 KVAR Capacitor Bank
S&F APFC relay etaCON M series with auto-set function 7 stage APFC relay Make:- L&T/ HPL/HAVELLS
DPS sales and services india
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .