| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹23.6 L+₹1.3 L (5.62%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹25.8 L+₹3.4 L (15.1%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹27.4 L+₹5.0 L (22.3%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
1 Oct 2020, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-180003
CERTAIN PETTY REPAIRS TO E/M SERVICES TO VARIOUS BUILDINGS, REPAIR/RENEWAL OF EARTHING SYSTEM OF LIGHTENING CONDUCTOR, ARRESTOR, BLDG AND ALLIED ITEMS AND REPAIR/MAINTENANCE OF ELECTRIC GEYSERS AT SUNJUWAN UNDER GE JAMMU
2020_MES_373925_1
GEJC-38/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AOR of GE Jammu
Class D category b i
8 documents required · 8 mandatory
₹500
GE Jammu
₹56,000
Yes
28 Oct 2020
3 Sept 2020
3 Oct 2020
3 Sept 2020
1 Oct 2020
17 Sept 2020
Amount
Taking down old unsv copper/aluminium point wiring concealed/batten (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden/iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specified and as directed.
Taking down old and unserviceable submain wiring any size of two core and including earth wire complete including batten/conduit and make good the disturbed surface to match the existing surface complete all as specified and as directed by Engineer-in-Charge.
Taking down old and unserviceable distribution board any type including MCBs etc after removing all connection and make good the disturbed surface complete all as specified and as directed by Engineer-in-Charge.
Taking down unserviceable MCCBs, MCBs, SP, SPN, TPN and isolator from the existing DBs complete all as specified and as directed by Engineer-in-Charge.
M&L for point wiring for one light/fan/5 Amps independent socket point/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into existing concealed PVC rigid/steel conduit and into existing CI/pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting swicthes, sockets, fan regulators etc complete all as specified and as directed. Note:- (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof/ceiling PVC conduit shall be provided on surface with proper fixing clips all as specified and as directed by Engr-in-Charge.
All as per Ser Item No 5.00 here-in- above but 5 Amp socket outlet on same board complete all as specified and as directed by Engineer-in-Charge.
All as per Ser Item No 5.00 here-in- above but socket outlet 5 Amps independent board complete all as specified and as directed by Engineer-in-Charge.
All as per Ser Item No 5.00 here-in above but for one 3 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed by Engineer-in-Charge.
M&L for point wiring for one light/fan/5 Amps independent socket point/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid/steel conduit ISI marked terminated into CI/pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Note:- (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof/ceiling PVC conduit shall be provided on surface with proper fixing clips all as specified and as directed by Engr-in-Charge.
All as per Ser Item No 9.00 here-in above but 5 Amp socket outlet on same board complete all as specified and as directed.
All as per Ser Item No 9.00 here-in above but socket outlet 5 Amps independent board complete all as specified and as directed by Engr-in-Charge.
All as per Ser Item No 9.00 here-in above but for one 3 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed.
All as per Ser Item No 9.00 here-in-above but drawn through and including new surface conduit PVC rigid non-metallic conduit 20mm dia for socket outlet 5 amp independent board complete with new pressed steel terminal boxes and hylam sheet cover complete all as specified and as directed.
All as per Ser Item No 9.00 here-in-above but drawn through and including new surface conduit PVC rigid non-metallic conduit 20mm dia for socket outlet 15 amp independent board complete with new pressed steel terminal boxes and hylam sheet cover complete all as specified and as directed.
M&L for replacement distribution board sheet steel phosphatised powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as specified and as directed by Engr-in-Charge.
M&L for replacement distribution board sheet steel phosphatised powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and as directed by Engr-in-Charge.
M&L for replacement distribution board sheet steel phosphatised powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and as directed by Engr-in-Charge.
M&L distribution board double door sheet steel phosphatised powder painted for MCB/DB with copper bus bar and neutral link earthing stud TPN 4 way 415 Volts double door complete all as specified and as directed.
S&F in replacement TP & N vertical load line double door DB with 200 Amps bus bar, 415 Volt sheet metal enclosure suitable for 'G' frame MCCB, 4 way complete all as specified and as directed.
S&F in replacement MCCB 4 pole, 415 Volt fixed thermal and fixed maganatic setting of cap 125 Amps 10 KA complete all as specified and as directed.
S&F in replacement Isolator 4 Pole, TPN 415 Volts, 100 Amps rating with rupturing cap 10 KA 'B' Series, complete all as specified and as directed.
S&F in replacement for MCB TP&N 63 Amps 415 Volts, 'B' series rupturing capcity 10 KA complete all as specified and as directed by Engr-in-Charge.
S&F in replacement for MCB SP 6 to 32 Amps, 240 Volts 'B' Series complete all as specified and as directed.
S&F in replacement for MCB SPN 32 Amps 240 Volts, 'B' series complete all as specified and as directed.
S&F in replacement for MCB SPN 40 Amps 240 Volts, 'B' series complete all as specified and as directed.
S&F in replacement for MCB SPN 63 Amps, 240 Volts, 'B' series complete all as specified and as directed.
S&F in replacement for switch piano, flush type single pole one way 5 Amp, 240 Volts complete all as specified and as directed.
S&F in replacement socket outlet 5 Amp/5 pin flush type complete all as specified and as directed.
S&F in replacement Switch socket outlet combined 5 pin 5 amp flush type, 240 Volts complete all as specified and as directed.
S&F in replacement Switch socket outlet combined 2 in 1, 3 pin 5 amp and 15 amp flush type, 240 Volts complete all as specified and as directed.
S&F socket outlet 15 Amps, 240 Volts, 6 pin flush type complete all as specified and as directed.
S&F for switch piano, flush type single pole one way 15 Amps, 240 Volts complete all as specified and as directed.
S&F for bell push, flush type, single pole, 5 Amp, 240 Volts complete all as specified and as directed.
S&F Ceiling rose 3 terminal surface type complete all as specified and as directed.
S&F in replacement PVC box (gang box) surface mounted heavy duty 3 way complete with socket outlet 2 in 1, 6 pin 5 amp 240 Volt along with switch piano 5 amp complete all as specified and as directed.
S&F in replacement PVC box (gang box) surface mounted heavy duty 3 way complete with socket outlet 2 in 1, 6 pin 15 amp 240 Volt along with switch piano 15 amp complete all as specified and as directed.
M&L in replacement for Lamp holder, insulated body, with back plate suitable for batten fittings complete all as specified and as directed.
M&L in replacement Self ballast LED retrofit Lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K complete all as specified and as directed.
S&F in replacement new generation Energy saving, wall mounted LED Tube Light batten fittings, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver 20 Watt LED 6500K (4' ft long) with LED rod 20 Watt, 230 Volts 50 Hz complete all as specified and as directed.
S&F in replacement new generation Energy saving, wall mounted LED Tube Light batten fittings, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver 14 Watt LED 6500K (2 ft long) with LED rod 14 Watt, 230 Volts 50 Hz complete all as specified and as directed.
S&F in replacement bulk head luminaries IP-65 with opal diffuser 10 watt, 230 Volts LED type complete all as specified and as directed by Engr-in-Charge.
S&F in replacement for replacement of LED street light fitting of cap 25 watt complete all as specified and as directed by Engr-in-Charge.
S&F in replacement recess mounting Energy efficient LED light bottom opening panel duly powder coated CRCA Steel housing IP-65 High quality polycarbonate body and aluminium plate heat sink, high quality diffuser, separate HPF driver suitable ceiling of 2' X 2' complete all as specified and as directed.
S&F in replacement Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S&F in replacement calling bell Ding Dong/buzzer AC 230 Volts, single pole complete all as specified and as directed.
M&L in replacement for Sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 4.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length. Note:- Wiring shall be done in proper colour coding.
M&L in replacement for Sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sqmm for phase and neutral and one run of 2.5 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length. Note:- Wiring shall be done in proper colour coding.
S&F in replacement LED tube rod of cap 18 watt, T8 240 Volts suitable for existing 36 watt fittings complete all as specified and as directed by Engr-in-Charge.
S&F in replacement LED tube rod of cap 18 watt, T5 240 Volts suitable for existing 28 watt fittings complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of SK light fitting with energy efficient LED wall bracket up/down light fitting with B-22 d with clear glass cover with LED lamp 9 watt complete all as specified and as directed.
M&L for fan regulator 1 module stepped type (electronic) for 1200/1400mm sweep AC ceiling fan complete all as specified and as directed by Engr-in-Charge.
M&L for capacitor 2.5 mfd 220 Volts AC 50 Hz complete all as specified and as directed by Engr-in-Charge.
M&L for capacitor 4.0 mfd 220 Volts AC 50 Hz complete all as specified and as directed by Engr-in-Charge.
M&L for single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps 240 Volts complete all as specified and as directed by Engr-in-Charge.
M&L for round sheet heavy duty for fixing on junction boxes/fitting/fixtures as required at site including suitable size machine screws as required complete all as specified and as directed by Engr-in-Charge.
M&L for replacement of unserviceable flexible wire 2 core of size 1.0 Sqmm with PVC insulated multistranded copper conductor twisted flexible wire for working voltage 1100 Volts complete all as specified and as directed by Engr-in-Charge.
M&L for replacement of unserviceable wire of size 1.5 sqmm single core FRLS insulated multistranded copper conductor for working voltage 1100 Volts Sqmm complete all as specified and as directed by Engr-in-Charge.
M&L for replacement of unserviceable wire of size 2.5 sqmm single core FRLS insulated multistranded copper conductor for working voltage 1100 Volts Sqmm complete all as specified and as directed by Engr-in-Charge.
M&L for replacement of unserviceable wire of size 4.0 sqmm single core FRLS insulated multistranded copper conductor for working voltage 1100 Volts Sqmm complete all as specified and as directed by Engr-in-Charge.
M&L for replacement of unserviceable wire of size 6.0 sqmm single core FRLS insulated multistranded copper conductor for working voltage 1100 Volts Sqmm complete all as specified and as directed by Engr-in-Charge.
M&L for PVC non metallic rigid conduit of size 20mm complete all as specified and as directed by Engr-in-Charge.
M&L for replacement Earthing complete with galvanised steel earth plate electrode 60 X 60 X 6.3mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel including GI protection pipes 20mm dia light grade and 15mm dia watering pipe medium grade upto test point, charcoal common salt, PCC 1:2:4 type B-1, Pit, CI cover with Handle, excavation and earth work in any type of soil, returning, filling and removal of surplus soil where directed to a distance n.exc. 50m rest complete all as shown in Electrical plate No 3 connected to earthing test point all as specified and testing on completion.
All as per Ser Item No 62.00 here-in-above but using galvanised iron strip of 32 X 6mm as earthing lead complete all as specified and as directed.
S&F in replacement test point terminal block made out of GI strip 32 X 6mm as per site requirement complete with fixing MS clamp nut bolt complete all as specified and as directed.
M&L for replacement of UNSV aluminium earth strip size 25 X 3mm thick complete with replacement of MS saddle/Clamp, fixing screw etc for roof conductor and down conductor above ground and on wall complete all as specified and as directed.
All as per Ser Item No 65.00 here-in-above but 32 X 6mm buried in ground and fixed on wall complete all as specified and as directed.
S&F in replacement GI tubing light grade complete with fitting and fixed to wall/ceiling floor 40mm dia complete all as specified and as directed.
M&L for replacement of Air termination single pointed aluminium rod 12mm dia and 300mm long complete all as specified and as directed.
Labour for repair to existing UNSV / Loose / Hanging GI or aluminium earth strip fix on and around the RCC reservoir complete with and including MS saddle/clamps, nut, bolt, screw as per site requirement and fix the strip properly with RCC reservoir wall. Note:- Rates are deemed to be including charges for hiring T&P and Life Insurance of person deputed at site.
M&L for replacement of tubing GI medium grade with all fittings laid in floor or trenches including taking out old UNSV pipe of size 15mm dia complete all as specified and as directed.
S&F in replacement Gun metal glove/gate valve 15mm dia internal threaded with iron wheel head confirming to ISI complete all as specified and as directed.
M&L for cutting to existing GI pipe line of any size in position for addition, alteration/for branch connection or insertion of tee complete with including GI fittings for jointing branch connection or insertion of tee complete with including GI fittings for jointing branch connection, threading, earthwork as per site requirement complete all as specified and as directed.
M&L for replacement of Syntex tank double layer 200 Ltr capacity water storage tank complete with float valve complete all as specified and as directed.
Taking down and strip opening to geyser of any make and cap 25/35/50 ltrs including disconnection of all water pipe connection and taking out water inlet/outlet assly, removing glass wool, the inner tank, descaling the assembly and tank, detecting the leakage, welding/brazing the defected part, repacking the glass wool and refixing the same after making it functional including replacement of worn out nuts, bolts, washer etc complete all as specified and as directed. Note:- Cost of material for providing new items shall be measured under relevant items of Sch 'A'.
Supply only water inlet and outlet geyser assembly of existing make as required at site with rubber gasket suitable for geyser of 25/35 ltrs capacity electric driven water storage heater with provn of housing for thermostat assembly, heating element, fixing arrangement nuts, bolts and washers etc complete all as specified and as directed.
Supply only water inlet and outlet assembly of existing make as required at site with rubber gasket suitable for geyser of 50 ltrs capacity electric driven water storage heater with provn of housing for thermostat assembly, heating element, fixing arrangement nuts, bolts and washers etc complete all as specified and as directed.
Supply only thermostat, switch electric water heater storage type of cap 25/50 ltr, 230 Volts of existing make of geyser complete all as specified and as directed.
Supply only heating element with traingular base/round base, single phase, 230 Volt, cap 2 KW of existing make complete all as specified and as directed.
Supply only heating element with traingular/round base, single phase, 230 Volt, cap 1.5 KW of existing make complete all as specified and as directed.
Supply only pressure release valve conforming to relevant IS 15mm bore suitable for fixing with GI pipe/tubing 15mm bore complete all as specified and as directed.
Supply only heavy duty PVC connection (For Hot water) nylon threaded 450mm large (18'') 15mm bore including brass nuts, rubber washers complete on both ends complete all as specified and as directed.
All as per Ser Item No 81.00 here-in-above but for cold water complete all as specified and as directed.
Supply only indicator lamps round/rectangular type 230 Volt AC suitable for geyser of any capacity including providing electric connections complete all as specified and as directed.
Supply only water storage inner tank of stainless steel heavy duty confirms to ISI 25/35 ltrs capacity geyser, with provn for fixing 15mm dia galvanized air release valve complete all as specified and as directed.
Supply only water storage inner tank of stainless steel heavy duty confirms to ISI 50 ltrs capacity geyser, with provn for fixing 15mm dia galvanized air release valve complete all as specified and as directed.
Supply and fixing in replacement MCB SPN 32 Amps 240 Volts, rupturing capacity 10 KA, 'C' series complete all as specified and as directed.
Supply and fixing in replacement plug top 15 Amps 3 pins complete all as specified and as directed.
Material and labour for painting of geyser of cap 25/35/50 ltr complete with superior quality synthetic enamel white paint by spray painting after scrapping old paint and making surface clean complete all as specified and as directed.
Material and labour for replacement Non return valve 15mm dia complete all as specified and as directed.
Material and labour for replacement Split bottom cover (two pieces) suitable for 25 to 50 ltrs Geysers complete with fixing arrangement etc as required at site complete all as specified and as directed.
Material and labour for replacement rubber Gasket heavy duty of water inlet outlet assembly suitable for 25 ltrs capacity Geyser complete all as specified and as directed.
Material and labour for replacement outer shell suitable for 25/35 ltr geyser made out of GI sheet heavy duly confirming to ISI suitable for existing make of geyser complete factory manufactured painted complete all as specified and as directed.
Material and labour for replacement outer shell suitable for 50 ltr geyser made out of GI sheet heavy duly confirming to ISI suitable for existing make of geyser complete factory manufactured painted complete all as specified and as directed.
S&F in replacement glass wool suitable for geysers complete all as specified and as directed.
Repair/Maintenance/Servicing to Solar water heater system having a capacity 100 to 500 LPD complete with descaling/cleaning to flat plate collector plate, solar heater water tanks, toughened solar glass panels, welding/breezing to solar tanks, Repair/rectification of leakage in Inlet/Outlet water tubing GI, checking and repair to electric system, Repair of water make up tank and make the system function cable after repair/servicing and rectification of the fault complete with and including replacement of minor spare parts. Note:- Spares shall be measured and paid separately.
Supply only union medium grade 25 mm dia complete all as specified and as directed.
Supply only union medium grade 20 mm dia complete all as specified and as directed.
Supply only Rubber hose pipe with MS clamp of suitable size complete all as specified and as directed.
Supply only Gun metal gate/glove valve 20mm dia complete all as specified and as directed.
Supply only Rubber gasket of toughened glass complete all as specified and as directed.
Supply only Painting to steel structure base frame complete all as specified and as directed.
Supply only float valve PVC 20mm dia complete all as specified and as directed.
Material and Labour for replacement of Electrical heating element long threaded type, as per existing 3 KW, ISI marked, single phase suitable for solar water heater complete all as specified and as directed.
M&L for replacement of thermostat, long body, ISI marked of solar water heater of cap 100 to 500 LPD complete all as specified and as directed.
M&L for replacement of Solar hot water tank with thermal Insulation suitable for solar water heater of cap 100 LPD complete all as specified and as directed.
M&L for replacement of Solar hot water tank with thermal Insulation suitable for solar water heater of cap 500 LPD complete all as specified and as directed.
ML for replacement of toughened Collector glass of size 1.5M X 1.0 Mtr complete all as specified and as directed confirming to ISI.
M&L for fasteners 80-100 mm long for fixing of geyser of capacity up to 50 ltrs including grouting completed works in wall as per site requirement with the floor complete all as specified and as directed.
S&F in replacement Chromium plated CP Bib cock 15mm dia conforming to ISI complete all as specified and as directed.
M&L for replacement of hot water pipe insulation with glass wool and aluminium cladding 20mm bore including all materials as required and directed by Engineer-in-Charge.
S&F sheet metal enclosure for MCB DB SPN 240 Volts, 2 way single door without bus bar, enclosure made up of CRCA sheet IP-30 including wooden rectangular board of first quality of suitable size for mounting of DB box complete all as specified and as directed by Engr-in-Charge.
M&L in replacement for Sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sqmm for phase and neutral and one run of 2.5 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn in but including non-metallic rigid PVC concealed conduit of 25mm dia fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length. Note:- Wiring shall be done in proper colour coding.
Sarbat Construction Co
M/S Bali Agencies
JINDAL BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .