Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.5 LAccepted-AOC | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹46.3 L+₹1.2 L (2.67%)Rejected-Finance SUBHASINI TEA ESTATE HASIMARA PS JAIGOAN DIST ALIPURDUAR WB PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹47.6 L+₹2.5 L (5.52%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹48.7 L+₹3.6 L (7.93%)Rejected-Finance HAMILTONGANJ NETAJI PALLY NEAR ICE FACTORY DISTT ALIPURDUAR WEST BENGAL 735 214 | ALIPURDUAR | WEST BENGAL | 735214 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹49.2 L+₹4.1 L (9.20%)Rejected-Finance SURJANAGAR ALIPURDUAR | ALIPURDUAR | ALIPURDUAR | WEST BENGAL | 736121 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
21 Oct 2024, 6:00 pmClosed
GE (AF) HASIMARA
GE (AF) HASIMARA, PO-HASIMARA, DIST- ALIPURDUAR, PIN-735215
INSTALLATION OF RED BEACON AT STATION RANGE AND SPL REPAIR/REPLACEMENT OF DAMAGED AND UNSERVICEABLE EARTHING FOR ELECTRICAL SAFETY AND CONNECTED ITEMS IN VARIOUS OMQ/SMQ AT AFS HASIMRA
2024_MES_675996_1
C/8811/2024-25/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
GE (AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) HASIMARA
₹92,000
30 Oct 2024
23 Sept 2024
23 Oct 2024
23 Sept 2024
21 Oct 2024
7 Oct 2024
Amount
S&F of LED type integral aviation obstruction light (heavy duty) IP65, double arm alongwith photo cell sensor switch including making arangement for connection into GI pipe of suitable dia and including connecting PVC copper cable 2.5 Sqmm 3 core from junction box to light fitting including making arrangement for fixing of light pole into wall/PCC, complete all as specified and directed. (Make : Kheraj Cat Part No. AVIL-HD-D or equivalent. Model in AGNI/MIMIC.)
S&F sheet metal enclosure for single door MCB DBs, phosphatised powder coated, Single Pole & Neutral (SPN) suitable for 2 way, 240 volts, 240 volts, IP 43 & IK 09 fixed on wall with din rail, neutral and earth bar in proper position all as directed SPN, 2 way IP 43 & IK 09 fixed on wall with din rail, neutral and earth bar in proper position, complete all as specified and directed.
S&F MCB Single Pole & Neutral (SPN) of capacity 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, 'C' series, fixed in proper position, complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 4 core including taking down old unserviceable UG cable of any description, complete all as specified and directed.
Excavation in trenches not exe. 1.5m in width and not exe 1.5m in depth on plan for foundation, laying pipes etc including forming bottom surface to required level and getting out in soft/loose soil, complete all as specified and directed.
Returning filling in incl spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point in any type of soil, complete all as specified and directed.
Supply and laying double walled corrugated (DWC) HDPE duct pipe of 40mm dia conforming to IS, approved colour complete with fittings for cable protection, complete all as specified and directed.
S&F 25mm bore GI tubing (light grade) complete with all fittings and fixture for fixing of aviation obstruction light, complete all as specified and directed.
S&F LED flood light 120 watt outdoor type, IP 65/66 including fixing arrangement as per site requirement including PVC copper cable 2.5 Sqmm 3 core and connecting existing system, complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in gorund (earth pit not less than 2.25 Mtr normal ground level),and top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised means of earth wire 4mm dia with bolts, nuts & check nuts, and washers of galvanised iron protection pipe light grade of 20mm bore and watering pipe GI medium grade of 20mm bore and filled with alternate layer of charcoal and common salt, watering funnel with wire mesh, earth pit chamber and cover CI frame PCC (1:3:6) type C-1 all as shown in electrical plate No-3 of SSR part-I (2009) connected to earthing test point all as specified and indicated, including all earth work excavation, returning filling and disposal of surplus soil and testing on completion, complete all as specified and directed. Notes : (i) Proper earthing pit should be provided with pit cover.
M&L for earthing complete with GI earth plate electrode 60 × 60cm × 6mm thick , buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to existing earth lead strip by means of bolts, nuts, check nuts and washers of brass or HS steel all as shown in electrical plate No. 3 connected to earthing test point and and necessary excavation and earth work PCC (1:3:6) type C-1 as earth pit with pre-cast RCC (1:2:4) type B-1 cover slab size 400 x 400 x 50mm reinforced with 8mm dia TMT bar, 100mm c/c both ways including one handle made of 12mm dia including providing charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode with funnel and 20mm bore galvanized iron watering pipe (light grade) wire mesh, copper lugs, complete in all respect, including galvanised iron earth strip 25 x 4mm, protected by 40mm bore (medium grade) galvanized iron pipe up to earthing test point as directed, incl disposal of spoil to a distance not exc. 50 mtr and necessary testing on completion including dismantling of old unserviceable earthing of any description, complete all as specified and as directed. Note : (i) Proper earthing pit should be provided with pit cover. (ii) GI earth strip beyond 7.5 mtr shall be measured and paid seperately.
M&L for earthing of equipment complete with copper earth plate electrode 60 × 60cm. × 3.15 mm thick , buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to existing earth lead strip by means of bolts, nuts, check nuts and washers of brass or HS steel in any type of soil, connected to earthing test point and and necessary excavation and earth work, PCC (1:2:6) type C-1 as earth pit with pre-cast RCC (1:2:4) type B-1 cover slab size 400 x 400 x 50mm reinforced with 8mm dia TMT bar, 100mm c/c both ways including one handle made of 12mm dia including providing charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode with funnel and 20mm bore galvanized iron watering pipe (light grade) wire mesh, copper lugs, complete in all respect,including Copper earth strip 20 x 3.15mm, protected by 40mm bore (medium grade) galvanized iron pipe up to earthing test point including disposal of soil to a distance not exc 50 mtr and necessary testing on completion including taking down old unserviceable earthing of any description, complete all as specified and directed. Note:- Proper earthing pit should be provided with pit cover.
Supply and installation of maintenance free earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of 3 m length, having a diameter of 25 mm with copper coating thickness of 250 microns with fault current withstand capability of 30 KA rms value of 1 second and I peak of 80 KA, tested as per IEC 62561-2, meets the requirement of IS-3043 & IEC 60364-5-54, tested in CPRI for short circuit with standing capacity, earth conductivity enhancing mineral compound to be used as a backfill compound for earth electrodes; highly conductive in all weather conditions is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 ohm -m. It should be free from hazardous substances. The mineral compound is required to have minimum 25 kg of the total composite, Universal clamp made of SS 304 for clamping, Polypropylene & polyethylene earth electrod inspection chamber with heavy duty cover should be used to cover the earth rod. The dimension shall be 170mm x 170mm x 190mm with a weight bearing capacity of 50 KN. including provision and laying copper flat 32 x 6mm thick from earth electrode to earthing test point directly in ground as required cross sectional area of 150mm square, as per DIN EN 62561-2 (VDE 0185 -561-2) & VDE0185/305, IEC 62305 including taking down old unserviceable earthing of any description, complete all as specified and directed. Note :- (i) Fresh soil shall be filled around earthing not less than 1m x 1m pit size to get better result shall be included in the quoted rates and unit quoted rate shall deemed to be included for the provision of earth filling. (ii) Earth work and excavation in any type of soil shall deemed included in the unit rate.
S & F copper strip of size 20 x 3.15mm with saddles and fixing screws etc. for roof conductors with rubber & bitumen washer & fixed to porcelain insulator on wall for down conductor including taking down old unserviceable copper strip of any size, complete all as specified and directed Note :- Copper strip & test point should be bounded by brazingFresh soil shall be filled around earthing not less than 1m x 1m pit size to get better.
S & F test point termination blok of size 75mm × 75mm × 25mm made of Gum Metal or phospherous bronze drilled and screwed including 3 Nos, 8mm dia 25mm long hexagonal headed screw and box of size 90mm ×90 mm × 90 mm (Made out of 1.6mm thick plain brass sheet )and screwed to wall for protection of test point including taking down old unserviceable copper strip of any size, complete all as specified and directed. (Note :- Copper strip & test point should be bonded by brazing.)
S & F in repair for GI strip of size 25 x 4mm with saddles and fixing screws etc. for roof conductors with rubber & bitumen washer & fixed to porcelain insulator on wall for down conductor, complete all as specified and directed
S & F in repair for GI wire earth continuity conductor or main earthing lead size 6 Sqmm fixed to wall on batten or recess or chase or buried in ground or drawn in conduit/pipe or fixed to pole or other indicated situation for loop earthing etc, complete all as specified and directed
S & F 40mm bore galvanized steel tubes, 'light grade' ISI marked with all fitting and fixed complete to roof slab / walls / pavement/ ceilings or laid on floors, including taking down old unserviceable pipes, complete all as specified and directed.
S & F 20mm dia PVC conduit, rigid, non metalic, exclusive of boxes but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc, complete all as specified and directed.
S & F for porcelain insulator suitable for fixing of aluminim/copper strip on roof/wall with necessary drilling and providing two Nos screw for each insulator, complete all as specified and directed.
Note: An amount of Rs 54,306.00 on account of Credit Schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S. VINITA CONSTRUCTION (BID ID -3138796)
M/S SARKAR ELECTRIC (BID ID -3138563)
MAJUMDER ENTERPRISE (BID ID -3138464)
SHRI SURAJIT SIKDER (BID ID -3138502)
M/S SANMILAN NANDI (BID ID -3139891)
M/S ANIL KUMAR BAUL (BID ID -3138529)
M/S ANNI ENTERPRISE (BID ID -3138988)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .