Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹47.9 L+₹3.3 L (7.34%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹48.7 L+₹4.1 L (9.10%)Rejected-Finance | L3 | Rejected-Finance Not Lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
14 Feb 2022, 6:00 pmClosed
GE NORTH PUNE
Garrison Engineer North General Cariappa Marg Camp Pune 411001
GE (N) P/TOKEN- 71 OF 2021-2022 PROVISION OF CERTAIN MW, LBW AND SPECIAL REPAIR WORKS IN THE AREA OF AGE E/M UNDER GE (NORTH) PUNE
2022_MES_501483_2
GE (N) P/TOKEN- 71 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NORTH PUNE
Refer tender documents.
8 documents required · 8 mandatory
₹500
GE NORTH PUNE
₹98,000
Yes
24 Feb 2022
29 Jan 2022
16 Feb 2022
29 Jan 2022
14 Feb 2022
2 Feb 2022
Amount
Taking down/out unserviceable UG Cables of any Cross Sectional Area and Connections and joints including Pipes, Bricks, etc of any description complete all as specified and as directed.
Supply & Laying, testing & commissioning of LT UG cable XLPE sheathed PVC insulated,screened PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade, laid in trenches/ surface of wall/ in GI pipe along with pole for connection to OH lines,including brass cable glands,clamps,etc including removal of existing unsv cable and making good damaged surfaces as required For size 16 Sqmm 4 core
Ditto all as per item no 2.00 here in above but for 10 Sqmm 2 core
Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified and as directed.
Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level n exc 50m above the starting point complete all as specified and as directed.
Supply and fixing weather proof street light junction box of size 300 x 200 x 105mm including MCB SP 6 Amps and connecting terminals 4 way and fixing with street light poles using necessary MS clamps, nuts, bolts washers, lugs for incoming and out going cables, gland for cable etc of suitable size complete all as specified and as directed. Make : Hensel/Sintex/Universal Switch Gear control Note : The rates quoted are inclusive of provision and fixing of suitable lugs and glands for cable connection.
S & F Integral decorative LED bollard with polycarbonate diffuser square shaped with IP 65 protection suitable for 9 watts LED bulb with necessary elecrical connections with adequate size including removal of old unserviceable one complete as all specified and as directed. Make: Bajaj Cat No BGBOS 600 9W LED, equivalent in Havells & Halonix.
S & F for LED post top lantern 40 watt light fitting made of cast aluminium spigot housing with decarative opal acrylic diffuser with IP 65 protection complete with all accessories fixed on GI pipe 50 mm dia including removal of old unserviceable one complete all as specified and directed. Make: Make: Bajaj Cat No BGCL 40W LED WH, equivalent in Havells & Halonix.
S & F for Energy saving new generation environmental friendly LED flood light luminaire with long life versatile pressure die-cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection with high power LEDs as light source and electronic driver with warranty option of 5 years from date of installation of capacity 120 watts with pre wired and necessary mounting arrangementsnd complete all as specified and directed.
M & L Cement Concrete 1:3:6 (20 mm graded aggregate) as in coping of pole , foundation etc including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified
Supply & lay 20mm dia DWC pipe in protection of cable at road crossing /hard standing as per site requirement etc all as specified and directed of size 25 mm dia bore complete all as specified.
Supply and fix black bolt with hexagon head and nuts round neck of any size as required at site complete all as specified and as directed
Material and for point wiring using approved colour coding as per IS , with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty,ISI marked PVC casing caping including all accessories fixed to walls/ceilings etc and providing surface mounting plastic box , with earth dolly, covered with modular white cover plate with frame suitable for modular switches , including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed for One fan point controlled by one, one way switch 6 Amps complete all as specified and as directed
Ditto all as per item no 13.00 here in above but for One 5 pin 6 Amps switch socket outlet point controlled by one, switch on independent board
Supply and fixing Modular switch piano flush type, one way 6A, one module complete all as specified and as directed.
S & F Ceiling rose, 3 terminal, surface bakelite ( ISI marked) and including plastic square PVC box surface mounted for fixing ceiling rose complete all as specified and as directed
Supply and fixing Energy Efficient BLDC Motor, wall mounted fan , Power-32 W consumption on high speed, Input voltage 90-245 V-AC single phase, Speed: 1350 RPM ,50 Hz , 400 mm sweep, 3 blade, and making connections complete all as specified & as directed. Make- Atomberg (EFFICIO +)
Supply and fix exhaust fan, AC single Phase, working on input voltage 140-285 , of size 250m sweep, 1200 RPM, Power 20 W with BLDC Motor, blades, frame and louvers provision of 3 core 1.5 sq. mm copper conductor PVC insulated & PVC sheeted flexible wire from ceiling rose/connector to fan including making connections complete all as specified & as directed . Make- Atomberg (EFFICIO)
Taking down chowkat or frame ( Wooden) / Steel not exc. 1.5 sq. m and removing to store complete all as specified and as directed
Supply and fix for aluminium anodised powder coated louvered ventilator with provision of exhaust fan opening with adjustable louvers using ‘Jindal” aluminium section or equivalent make as specified including glass 3mm thick ordinary quality, frosted and stainless steel wire mesh 0.36mm dia wire and 1.40mm aperture etc complete all as specified and directed.
Supply and fix for aluminium anodised powder coated three track sliding window with two glazed shutters, one shutter with and including 4mm thick ordinary quality float glass and one shutter with and including stainless steel wire mesh 0.36 mm dia wire and 1.40mm aperture including good quality of bearing, handle, locks, PVC rubber lining of transparent colour etc including dismantling old unserviceable window and making good complete all as specified and as directed. Catalouge numbers of Jindal company or equivalent make sections : Three track bottom – 20957, Three track top/vertical – 20958,Handle – 20606, Interlocking – 20605, Top and bottom – 20604.
Material and Labour for Tubes, 'Medium grade' galvanised, bore of pipe 40mm with all fitting and fixed complete to walls and ceilings or laid in floor complete all as specified and as directed.
Supply and Installation, commissioning of wall mounting air cooled split type unit air conditioner electric driven single phase indoor unit and outdoor unit with cordless remote control unit and with in built airioniser and plasma filter for better indoor air quality cutting ,brazing and connecting the copper pipe of size 1/2 inch and 1/4 inch size of pipe and making holes as for passing of copper pipes and electric cables and pressure testing with nitrogen and freon gas vacumising the system and charging the Non CFC refrigerent and testing the complete system for smooth functioning of split AC up to satisfactioning, above 4 star rating, confirming to IS-1391 Para II 1992 herimatically sealed air compressor working with Non CFC refrigerent suitable for wall mounting 6000 K cal/ hrs 2 Ton complete with stand for fixing on wall/ground complete all as specified and as directed
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with multistranded copper conductor of size 04 Sq. mm nominal area and drawing into PVC non metallic rigid heavy duty conduit ISI marked and its accessories including one run of PVC insulated 4 Sqmm (nominal area) FRLS multistranded copper conductor cable as earth wire complete all as specified and as directed.
Supply and fix, installation of 5 KVA voltage stabilizer for automatic operation with copper wound coil, single phase naturally air cooled indoor type wall mounted with electronic time delay relay, designed for input variation between 170 volt to 250 volts with out put voltage at 230 volt with accuracy of + 2.5% suitable for above water cooler complete all as specified and as directed.
Supplied and fixed single pole and neutral sheet metal enclosure suitable for 240 V with a two pin and earth plug and socket plug top complete with one single pole MCB 20 Amps complete all as specified and as directed
S & F for copper tubing of size 3/8” for discharge line any make of split AC of capacity 2 ton with insulation sheet of pipe tube type insulation complete all as specified and directed.
S & F for copper tubes of size 5/8” for Suction line of split AC of capacity 2 ton including insulation sheet of pipe tube type insulation complete all as specified and directed.
Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or infloors etc., any type of pipe size 15 mm
Supply and fixing Multi purpose high quality Air conditioner rust proof powder coated, wall mounting outdoor unit stand consisting of (Bracket - 02 Nos & L Shape-02 Nos) made out of 3mm thick high grade steel including Anchor fastners, with nuts bots and washers complete all as specified and as directed
S & F Dual AC controller supply voltage 230 V AC, 50 HZ rating 30A at 230 V AC for compressor, temprature sensor, auto/controller Bypass switch etc all as specified and as directed.
M & L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm copper strip
M & L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw
Supply and Installation of advance Maintenance free tripod ring earthing system by boring the required nos of holes in semi hard soil or hard soil consisting of 03(three) Nos. UL 467 listed and CPRI tested copper bonded high tensile low carbon steel core electrode rod of 17.2 mm dia with a minimum coating thickness of 250 microns and length of 3 metres tested according IEC 62561-2 with min 10 years life span (the rod should be marked as per the UL certification) Model: AGE-APLI with up and down both side copper plate welded with GI 40mm tube as outer cover of electrod internaly and externaly covered with compound min 3X 25kgs/electrode of earth enhancing compound for each earthing pit (PROCEM) NABL certified, CPRI tested, ecofriendly, tested as per the IEC 62561-7 and needs to be considered to fill the 200mm bored hole surrounding to the outer/external cover of electrod.In one tripot earthing minimum 09 electrod to be fixed considreded as one earthing. The earth enhancing compound should have resitivity less than 50 ohm-meter with chemically inert to sub soil that should not pollute the environment and non corosive to the earth electrode itself including refilling with good earth Provision of the connectors for connecting electrode with earthing conductor/strip including fastener made of stainless steel having suitable size according to the electrode and earthing conductor dimensions. All the three earthing electrode would be seperated by appropriate distance and connected to earth other by the incl 32mmx6mm copper strips/copper wire to make ring earth and upto test point terminal and to be burried in appropriate depth not less than 40cm below normal ground level and earth pit chamber of suitable size not less than 250x250x250mm internal dimension made of FRP material complete with flush moundted removable and lockable cover able to withstand 15KN for each earth electrode all as directed by Engineer-in-Charge.
Provision of the connectors for connecting electrode with earthing conductor/strip including fastener made of stainless steel having suitable size according to the electrode and earthing conductor dimensions further connected up to equipment. The earth result should be less than one ohms other wise payment will not be considered for the work executed under item of earthing. The chamber should have facility for marking earth resistance and latest testing date by paint at the cover including testing and taking out old UNSV earthing pit for credit complete all as specified and directed by Engineer-in-Charge. Make : ASHGEL ELECTRODE/ OBBettermann /FUrse/KLK/Erico/ U-Protech all as per the descrition of Engineer-in-Charge.
NOTE: - (a) The rate shall include excavation, earth work, removal of surplus soil, returning filling with back fill compound, etc. (b) Earthing resistance result should be confirming to the value as specified in clause 19.146.14 of SSR Part-I 2009. If the result do not confirm, then the contractor will carry out the earthing in seperate location/site given by the Engineer-in-Charge after taking out of earth electrodes all without any extra cost to the Govt. (c) The contractor will provide all the required and necessary certificate(s) as per the specifications for required item(s) mentioned above from the same company before incorporating the same in the work as directed by Engineer-in-Charge and the rep of Company should be available at the site for the installation of the earthing as per their recommendation and specification to obtain the minimum resistance valve. (d) Test equipment will be duly tested from authorized Govt Lab/CPRI Lab and sealed by the testing authority and produce test certificate of testing equipment before testing for which no extra payment shall be borne by the Govt.
(e) Testing of earthing after completion of work will be carried out in presence of the GE, Engineer-in-Charge, rep of user and the Contractor. (f) Contractor will provide the gurantee for earthing and result for the period of minimum 05 years. (g) Copper strip beyond test point shall be measured and paid separately. Marking Earthing Pit with white/ coloured Hylam sheet/per pex sheet 3mm thick of size 200x150 mm fixed with MS angle iron 20X20X4 mm and .75 mtr long lncluding painting with synthetic eneamelled paints 2 coats over a coat of red oxide primer fixed by means of 2 nos nuts,bolts,washer of suitable size and grout the maker nearer to the earth pit with PCC 1:2:4 of size 0.15 x 0.15x 0.15 m including necessary earth work.Maker shall be written the following letters (letter of size 25 mm) CHEMICAL TRIPOD EARTHING EARTH PIT NO: EQUIPMENT/BUILDING CONNECTED: DATE OF TEST: EARTH RESISTENCE IN OHMS : Name plate white/coloured hylam sheet/perpex of 3mm thick of size 150x100 mm and fixer to the equipment/building or nearest to the equipment on the wall by screwing and name plate shall be written the following letters (letters of size 25 mm) CHEMICAL TRIPOD EARTHING EARTH PIT NO: EQUIPMENT/BUILDING CONNECTED: DATE OF TEST: EARTH RESISTENCE IN OHMS :
Note : 1. Performance security:- Refer Condition 22 of Special Conditions. 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site.
ganesh electricals and airconditioners
Suchit constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .