Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.8 LAccepted-Finance | L1 | Accepted-Finance ACCEPTED | |
| 2 | L2₹51.1 L+₹2.2 L (4.57%)Accepted-Finance | L2 | Accepted-Finance ACCEPTED | |
| 3 | L3₹52.1 L+₹3.3 L (6.69%)Accepted-Finance | L3 | Accepted-Finance ACCEPTED | |
| 4 | L4₹52.5 L+₹3.7 L (7.55%)Accepted-Finance | L4 | Accepted-Finance ACCEPTED | |
| 5 | L5₹52.8 L+₹4.0 L (8.10%)Accepted-Finance | L5 | Accepted-Finance ACCEPTED |
Tender Value
Refer Docs
EMD Value
₹95,000
Closing Date
28 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJ YOGESH PANDEY
GE 859 EWS
SPL REPAIR REPLACEMENT CABLES
2025_MES_713099_1
8930/E8
Open Tender
Electrical and Maintenance Works
Item Rate
Tawang
As per tender Documents
7 documents required · 7 mandatory
₹500
Yes
₹95,000
Yes
1 Aug 2025
7 Jun 2025
30 Jun 2025
7 Jun 2025
28 Jun 2025
21 Jun 2025
Amount
Supply and Laying and connecting with appropriate lugs in replacement XLPE LT cable PVC insulated 10 Sqmm 2 Core , heavy duty electric cables with Aluminum conductors,1100 volts grade, laid in trenches/on pole/in pipe /on wall ,using suitable clamps for fixing of cable complete all as specified and directed of following cross-sectional area including removing/ taking down of old unserviceable cables :-
16 Sqmm 2 Core
25 Sqmm 2 Core
35 Sqmm 3.5 Core
50 Sqmm 3.5 Core
70 Sqmm 3.5 Core
Excavation in trenches, n exc 1.5m wide and m exc 1.5m in depth, for foundation, etc or for shafts, wells, cess-pits, menholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out for soft/loose soil.
Returning, filling in, including spreading, levelling, waterring and wall ramming in layers not exc 25 cm. for hard/dense soil.
Removing excavated material n exc. 50 m and depositing where directed at a layers not exc 25 cm. for hard/dense soil.
S&F High density polyethylene pipes (HDPE) 50 mm bore of pressure rating 6 kgf/cm2 laid all as specified and as directed.
M & L for cable route marker with route indication on cast iron disc of 100mm dia and 10mm thick, marked / written for "LT CABLE 1100 VOLTS" embosed including indicating direction fixed / bolted to 40mmx40mmx6mm thick MS angle iron support of 0.5m long embedded upto 200mm depth in concrete block of size 200mm x 200mm x 500mm of mix PCC 1:3:6, type C-1 including painting with two coats of synthetic enamel paint over a coat of red oxide primer to exposed steel surfaces complete all as specified and directed.
S&F in replacement sheet metal enclosure double door for MCB DB single pole and neutral 4 way with 200 Amps rated bus bar 240 volts double door (Metallic) type all as specified and directed .
S&F in replacement sheet metal enclosure double door for MCB DB single pole and neutral 8 way with 200 Amps rated bus bar 240 volts double door (Metallic) type all as specified and directed .
S&F MCB SPN 40 Amps 240 volts 'C' series, 10 KA, 50 Hz.
S&F MCB SP 5 to 32 Amps 240 volts 'C' series, 10 KA, 50 Hz including connection in the DB and testing/commissioning.
M&L cutting the road hard standing & making good surface with PCC 1:3:6 C-1 Type Using 20 mm graded stone aggregate & removing the to distance n.exe 50mtr all as specified.
M&L for earthing complete with galvanised steel earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to galvanised earth lead strip 32x6mm by means of volts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15 mm bore GI medium grade earth lead protection pipe, 50 mm thick RCC 1:2:4 type B-1 cover slab of earth pit reinforced with 8 mm dia TMT bars @ 10 cm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer,charcoal and testing on completion including demolition of old earthing pit all as specified and directed..
M&L for cement concrete in foundations, filling and mass concrete D2, 1:4:8 (40mm graded aggregate).
M & L for PCC (1:2:4) type B-1(20 mm graded stone aggregate) mass concrete as in drain wall/R wall etc complete.
Use and waste flat form work to vertical faces of drain/retaining wall and similar work .
Extra for forming fair finishing drain or channels 30 cm inner girth in cement concrete using extra cement including forms, moulds stopped ends etc.complete all as specified and directed.
M&L rendering 15mm thick in CM 1:4 on concrete outer surfaces finished even and smooth without using extra cement .
M&L for rendering 15 mm thick plaster on fair faces of brick/concrete surfaces in CM (1:6) on internal wall surface, finished even and smooth without using extra cement.
BROKPA CONSTRUCTION (BID ID -3338135)
M/S SONAM PEMA ENTERPRISES (BID ID -3338407)
passang construction (BID ID -3338297)
M/s Roltso Enterprises (BID ID -3338365)
M/S R N ENTERPRISES (BID ID -3337085)
M/S ST ENTERPRISES (BID ID -3339374)
M/S TP ENTERPRISES (BID ID -3338393)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .