Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹13.0 LAccepted-AOC | L-1 | Accepted-AOC Being lowest bidder | |
| 2 | L-2₹17.6 L+₹3.2 L (22.3%)Rejected-Finance | L-2 | Rejected-Finance Other than lowest bidder | |
| 3 | L-3₹18.1 L+₹3.6 L (25.2%)Rejected-Finance | L-3 | Rejected-Finance Other than lowest bidder | |
| 4 | L-4₹18.9 L+₹4.4 L (30.8%)Rejected-Finance SIMBAL CAMP WARD NO 5 NEAR GURUDWARA SAHIB R S PURA DISTT JAMMU J K 1812104 | R S PURA | JAMMU | J K | 1812104 | L-4 | Rejected-Finance Other than lowest bidder | |
| 5 | L-5₹19.1 L+₹4.7 L (32.5%)Rejected-Finance | L-5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹44,000
Closing Date
10 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Jammu
GE Jammu c/o 56 APO Pin-900277
REPAIRS TO SECURITY LIGHTS AT DAMANA AND MIRAN SAHIB UNDER GE JAMMU
2022_MES_501312_1
GEJC-64/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender Documents
9 documents required · 9 mandatory
₹500
GE Jammu
₹44,000
Yes
30 Mar 2022
13 Jan 2022
12 Feb 2022
13 Jan 2022
10 Feb 2022
27 Jan 2022
60 days
Amount
Material and labour in replacement of PVC insulated and sheathed cable of size 1.5 sqmm 3 core copper conductor multistranded 1100 volt grade 230 volts running through PVC conduit of dia 20mm with strip clamping on poles at 3 places complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in any type of soil for taking up or laying of cable complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches exceeding 1.5 metre and not exceeding 3.0 metre in depth and getting out in any type of soil for taking up or laying of cable complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and as directed.
Removing excavated materials not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Supplying and laying bricks common burnt clay sub class 'B' old size for cable protection including taking down old one complete all as specified and as directed.
Supply and laying dry sand laid in trenches as cable cushioning and covering all as directed. Sand cushioning to underground electric cable 8cm before laying and 15cm after laying the cable in trenches complete all as specified and as directed.
Material and labour for PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) for stay assembly complete all as specified and directed.
Material and labour for PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) for pole foundation complete all as specified and directed.
Taking out unserviceable LT cable / service wire complete all as specified and directed from the site.
Material and labour for LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 10 Sqmm, 4 core complete all as specified and directed by Engineer-in-Charge.
Supply and fix indoor / outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 / 4.0 X 10 - 16 Sqmm complete all as specified and directed by Engineer-in-Charge.
Dismantling and removing and setting aside PCC pole / struts any type by breaking PCC foundation after disconnecting electrical connection including site clearance complete all as specified and directed by Engineer-in-Charge.
Material and labour for steel swagged poles complete poles 9 metre long complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 and applying two coats of aluminium paint over one coat of red oxide primer and including marking alternate 5 no's black and white strip 30cm height with two coats of synthetic enamel paint over a coat of primer including preparation of new surfaces complete all as specified and directed.
Supply and fix and fabrication street light bracket made out of GI tubing suitable for 45 / 60 / 90 watt LED light grade upto 1.2 metre length, bend to shape suitable for security light fitting with necessary MS clamps with one coat of red oxide primer and two coats of aluminium paint including nut, bolt, washers etc and including taking out unserviceable bracket and removing from site of work complete all as specified and directed.
Labour for repair / maintenance to old / unserviceable LED security / street / flood light of any capacity including taking down existing fitting from pole / building for replacement of unserviceable driver, cable terminal block and connection wire and refixing the same in position after repair including testing complete all as specified and directed by Engineer-in-Charge. Note: - Spares shall be measured and paid separately under respective items.
Taking down unserviceable street / security light fitting of any type from the pole / building after disconnecting electric connection carefully for replacement of drivers complete all as specified and as directed. Note: - Repair / replacement of spares shall be measured separately.
Supply and fixing in replacement of electronic driver of capacity 45 watt of existing make for LED street light fitting complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of electronic driver of capacity 60 watt of existing make for LED street light fitting complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of electronic driver of capacity 90 watt of existing make for LED street light fitting complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of electronic driver of capacity 120 watt of existing make for LED street light fitting complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of electronic driver of capacity 200 watt of existing make for LED flood light fitting complete all as specified and directed by Engineer-in-Charge.
Dismantling and taking down old unserviceable street / security lights and material and labour for new LED street light fittings of 30 watt, suitable for upto 50mm outer diameter holder fixed on existing pole, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66 protection suitable for pole mounting SMD LED array with lense, cool white 6500K, LED efficacy > 120 Im / W and system efficacy 110 Im / W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V - 270V, Power factor > 0.95, working temperature range - 20°C to 60°C, built in surge protection more than 10KV with facility of power supply shall be removed without removing light fitting from pole including make proper connection complete including cutting, welding, drilling holes, nut, bolts, washer complete all as specified and as directed by Engineer-in-Charge.
Dismantling and taking down old unserviceable street / security lights and material and labour for new LED street light fittings of 45 watt, suitable for upto 50mm outer diameter holder fixed on existing pole, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66 protection suitable for pole mounting SMD LED array with lense, cool white 6500K, LED efficacy > 120 Im / W and system efficacy 110 Im / W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V - 270V, Power factor > 0.95, working temperature range - 20°C to 60°C, built in surge protection more than 10KV with facility of power supply shall be removed without removing light fitting from pole including make proper connection complete including cutting, welding, drilling holes, nut, bolts, washer complete all as specified and as directed by Engineer-in-Charge.
Dismantling and taking down old unserviceable street / security lights and material and labour for new LED street light fittings of 60 watt, suitable for upto 50mm outer diameter holder fixed on existing pole, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, TOP opening separate driver compartment with frame, silicon gasket for IP-66 protection suitable for pole mounting SMD LED array with lense, cool white 6500K, LED efficacy > 120 Im / W and system efficacy 110 Im / W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V - 270V, Power factor > 0.95, working temperature range - 20°C to 60°C, built in surge protection more than 10KV with facility of power supply shall be removed without removing light fitting from pole including make proper connection complete including cutting, welding, drilling holes, nut, bolts, washer complete all as specified and as directed by Engineer-in-Charge.
Dismantling and taking down old unserviceable street / security lights and material and labour for new LED street light fittings of 90 watt, suitable for upto 50mm outer diameter holder fixed on existing pole, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, TOP opening separate driver compartment with frame, silicon gasket for IP-66 protection suitable for pole mounting SMD LED array with lense, cool white 6500K, LED efficacy > 120 Im / W and system efficacy 110 Im / W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V - 270V, Power factor > 0.95, working temperature range - 20°C to 60°C, built in surge protection more than 10KV with facility of power supply shall be removed without removing light fitting from pole including make proper connection complete including cutting, welding, drilling holes, nut, bolts, washer complete all as specified and as directed by Engineer-in-Charge.
Dismantling and taking down old unserviceable street / security lights and material and labour for new LED street light fittings of 120 watt, suitable for upto 50mm outer diameter holder fixed on existing pole, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, TOP opening separate driver compartment with frame, silicon gasket for IP-66 protection suitable for pole mounting SMD LED array with lense, cool white 6500K, LED efficacy > 120 Im / W and system efficacy 110 Im / W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V - 270V, Power factor > 0.95, working temperature range - 20°C to 60°C, built in surge protection more than 10KV with facility of power supply shall be removed without removing light fitting from pole including make proper connection complete including cutting, welding, drilling holes, nut, bolts, washer complete all as specified and as directed by Engineer-in-Charge.
Dismantling and taking down old unserviceable street / security lights and material and labour for new LED flood light fittings of 120 watt system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, IP-66 protection suitable for pole mounting SMD LED array with lense, cool white 6500K, LED efficacy > 120 Im / W and system efficacy 90 Im / W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V - 270V, Power factor > 0.95, working temperature range - 20°C to 60°C, built in surge protection more than 10KV with facility of power supply shall be removed without removing light fitting from pole including make proper connection complete including cutting, welding, drilling holes, nut, bolts, washer complete all as specified and as directed by Engineer-in-Charge.
Dismantling and taking down old unserviceable street / security lights and material and labour for new LED flood light fittings of 200 watt system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, IP-66 protection suitable for pole mounting SMD LED array with lense, cool white 6500K, LED efficacy > 120 Im / W and system efficacy 90 Im / W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V - 270V, Power factor > 0.95, working temperature range - 20°C to 60°C, built in surge protection more than 10KV with facility of power supply shall be removed without removing light fitting from pole including make proper connection complete including cutting, welding, drilling holes, nut, bolts, washer complete all as specified and as directed by Engineer-in-Charge.
Taking down old unserviceable timer switches and supply and fixing of automatic street light control with infrared sensor based NATURE SWITCH and VOLTAGE MONITORING SYSTEM (VMS) single phase load of 8 KW for automation of street lights. Nature Switch operation should be based on Natural light Lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF > 30 Lux. The sensor should also have part night operation facility of minimum 4 hours to maximum 12 hours. VMS should have adjustable over and under voltage trip level and protection against phase loss, Neutral loss and Phase reverse including Power contactors (1 no of capacity 63 amps per phase each) and incoming (1 no of capacity 63 amps each)- outgoing MCB (1 no of capacity 63 amps each) and main load circuit wiring (Copper) of minimum 16 sqmm. The sensor, VMS, Power contactor, MCB's including connected items should be enclosed in a Pole / wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-54 complete all as specified and as directed.
Supply and fixing in repair SMC Pole mounted box of size 10" x 8" x 4" with hinged door including clamp, nuts, bolts and washers complete with all as specified and directed and including following accessories: - (a) MCB SP 10 Amp, 10 kA 'C' Series mounted on din rail - 1 No. (b) Connector block suitable for 3 phase, 4 wire minimum 16 sqmm cable - 1 No.
Material and Labour for replacement of old unserviceable switch fuse unit / MCB of any type / capacity with new MCB FP 40 Amps 415 AC, 50 Hz, 25kA with sheet metal enclosure complete all as specified and as directed.
Material and Labour for replacement of old unserviceable switch fuse unit / MCCB of any type / capacity with new MCCB FP 63 Amps 415 AC, 50 Hz, 25kA with sheet metal enclosure complete all as specified and as directed.
Supply and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular 10 sqmm complete all as specified and as directed.
Material and labour for replacement of LT underground Cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area 10 Sq mm, 2 core complete all as specified and as directed.
Supply and fixing in replacement of electronic LED bulb 20 watt light fitting complete all as specified and as directed.
NOTE NO 1: - Samples of materials as approved will be kept in GE's sample room. NOTE NO 2: - All fittings and fixtures mentioned above will be fixed to the satisfaction of Engr-in-Charge and GE. NOTE NO 3: - Warranty certificate to the Engineer-in-Charge where ever applicable shall be submitted by the Contractor at the time of fittings.
Bidder Name
Sarbat Construction Co
M/s. Aggarwal Engineers
M/s Sahib Construction and engineers
M/S ASHOK KUMAR SURI
vishesh engineers
M/S SALARIA ASSOCIATES
JCC ENGINEERS PRIVATE LIMITED
M/S ZTECH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .