Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹16.9 L+₹1.5 L (10.0%)Rejected-Finance 60 310A 3 KHERIA MOD JAGNER ROAD AGRA 01 | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance Being higher bidder | |
| 3 | L3₹18.5 L+₹3.2 L (20.9%)Rejected-Finance | L3 | Rejected-Finance Being higher bidder | |
| 4 | L4₹20.5 L+₹5.1 L (33.4%)Rejected-Finance | L4 | Rejected-Finance Being higher bidder | |
| 5 | L5₹22.7 L+₹7.4 L (48.0%)Rejected-Finance NAGLA UDHA NEAR PRIMARY SCHOOL POST DHANOLI AGRA UP AGRA 282010 | AGRA | AGRA | UP | 282010 | L5 | Rejected-Finance Being higher bidder |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
14 Mar 2023, 6:00 pmClosed
GE AF TECH AREA AGRA
GE AF TECH AREA AGRA
REPAIR AND MAINTENANCE OF DG SET AND AMF PANEL FOR STAND BY DG SET IN ZONE A UNDER GE AF TECH AREA AGRA
2023_MES_580968_1
8200-1493/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF TECH AREA AGRA
AS PER NIT
9 documents required · 9 mandatory
₹500
Yes
GE AF TECH AREA AGRA
₹54,000
Yes
10 Apr 2023
14 Feb 2023
16 Mar 2023
14 Feb 2023
14 Mar 2023
28 Feb 2023
15 Feb 2023 - 21 Feb 2023
Amount
M&L for servicing of upto 40 KVA DG set including replacement Engine oil and all type of filters as per manufacturers manual. Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and filling and topping of new engine oil complete all as specified and directed. (Note:- (a) Engine oil will be measured and paid separately under respective items of schedule 'A'. (b) Each servicing of DG Set will be required after 6 months or 250 hours working. ( c ) servicing of DG Set shall be carried out by the authorised workshop.
M&L for servicing 50 KVA to 82.5 KVA DG set including replacement Engine oil and all type of filters as per manufacturers manual. Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and filling and topping of new engine oil complete all as specified and directed. (Note:- (a) Engine oil will be measured and paid separately under respective items of schedule 'A'. (b) Each servicing of DG Set will be required after 6 months or 250 hours working. ( c ) servicing of DG Set shall be carried out by the authorised workshop.
M&L for servicing of 100 to 180 KVA DG set including replacement Engine oil and all type of filters as per manufacturers manual. Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and filling and topping of new engine oil complete all as specified and directed. (Note:-(a) Engine oil will be measured and paid separately under respective items of schedule 'A'. (b) Each servicing of DG Set will be required after 6 months or 250 hours working. ( c ) servicing of DG Set shall be carried out by the authorised workshop.
M&L for servicing of 200 to 320 KVA KVA DG set including replacement Engine oil and all type of filters as per manufacturers manual. Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and filling and topping of new engine oil complete all as specified and directed. (Note:-(a) Engine oil will be measured and paid separately under respective items of schedule 'A'. (b) Each servicing of DG Set will be required after 6 months or 250 hours working. ( c ) servicing of DG Set shall be carried out by the authorised workshop.
M&L For dismantling the engine of DG Set capacity 125 to 320 KVA for checking and repairing , overhauling work by opening complete engine head piston, cylinder and FIP unit including remote cylinder head covers&check valve clearance between rocker arms and valve stem end wirth filler guage as per the valve setting sequence 0.3mm for inlet valve and 0.5mm for exhaust valve reassembling the existing parts complete testing on full load all as specified and as directed by Engr-in Charge. Note :- Replaced major spare parts Items required to make the DG set serviceable shall be measured and paid seperately under relevent item of schedule as supply only.
Supply only kit engine piston
Supply only piston liner kit
Supply only starter 12V DC complete
Supply only oil seal rear
Supply only bearing thurst
Supply only sleeve injector
Supply only valve inlet
Supply only valve exhaust
Supply only starter ring 121 teeth,3175 module
Supply only valve seat
Supply only ring liner seal
Supply only gear wheel complete
Supply only gasket of head gaskets, body gaskets complete
Supply and filling of Engine oil 15 W / 40 complete all as specified and directed. Make :- Castrol / HP / Bharat Petrolium / Valvoline
Supply and filling of coolant suitable for radiater of DG sets complete all as specified and directed. Make: HP/TVS / Valvoline / KIRLOSKAR
S&F in renewal of battery terminal brass(heavy duty)with nuts & bolts (as per sample) complete all as specified and directed.
Supply and filling distilled water suitable for DG set complete all as specified and directed.
Disconnecting of self starter 12/24 volts DC, dismantling and repairing with renewal of bendex pinion , rewinding of armature , bushes set , rewinding of field coil assembly, reassembling and refitted including testing of the complete self starter of DG Set for capacity upto 82.5 KVA Complete all as specified and directed.
Disconnecting of self starter 12/24 volts DC, dismantling and repairing with renewal of bendex pinion, rewinding of armature, bushes set,rewinding of field coil assembly, reassembling and refitted including testing of the complete self starter of DG Set for capacity from 100 to 160 KVA Complete all as specified and directed.
Taking down old repairable Radiator by opening nut/bolt from DG set mounting and loading and transportation to local market for checking, unloading testing for any defects and repairing as below : - Cleaning, washing the copper tubes and Top to bottom Copper fins Frame of the radiator by acid process. Checking the leakage if any and repairing the same by Soldering and Testing radiator, loading transportation and unloading & including refixing to its old position with proper accuracy and correct situation for Capacity from 20 KVA to 40 KVA DG sets including renewal MS/GI of nut/bolt, hose pipe sets with MS/ GI clamps and testing complete all as specified and directed.
Taking down old repairable Radiator by opening nut/bolt from DG set mounting and loading and transportation to local market for checking, unloading testing for any defects and repairing as below : - Cleaning, washing the copper tubes and Top to bottom Copper fins Frame of the radiator by acid process. Checking the leakage if any and repairing the same by Soldering and Testing radiator loading, transportation and unloading & including refixing to its old position with proper accuracy and correct situation for Capacity from 62.5 to 82.5 KVA DG sets including renewal of MS/GI nut/bolt, hose pipe sets with MS/ GI clamps and testing complete all as specified and directed.
Taking down old repairable Radiator by opening nut/bolt from DG set mounting and loading and transportation to local market for checking, unloading testing for any defects and repairing as below : - Cleaning, washing the copper tubes and Top to bottom Copper fins Frame of the radiator by acid process. Checking the leakage if any and repairing the same by Soldering and Testing radiator unloading and transportation and unloading & including refixing to its old position with proper accuracy and correct situation for Capacity from 100 KVA to 160 KVA DG sets including renewal of MS/GI nut/bolt, hose pipe sets with MS/ GI clamps and testing complete all as specified and directed.
Taking down old Radiator by opening nut/bolt from foundation and supply, installing and testing new Radiator with proper accuracy and correct situation for Capacity from upto 200 KVA DG sets including MS/ GI nut/bolt, hose pipe sets with MS/ GI clamps and testing complete all as specified and directed.
M & L for disconnection, taking down and repairing of alternator DC from DG set engine with rewinding of armature ,renewal of carbon brushes, renewal of bearings, rewinding of field coil assembly, renewal of connection plate, reassembling and refixing to DG set engine after necessary repair for the following sizes complete all as specified and directed:-
M & L for repairing of automatic battery charger of 12 Volt / 24 Volts including rewinding of transformer unit and renewal of diode plates, rectifier plates, auto cut mosfet circuit , fuses etc. and testing for following sizes complete all as specified and directed:-
M & L for repairing of canopy doors complete with renewal of following items including denting and necessary welding of doors complete all as specified and directed:-
M.S. Door lock of size 5.75" x 4.5" and of 08 levers
M.S.door handle of 150mm size
M.S. Butt hinges of 100 mm size medium weight
M & L in renewal of flywheel ring with proper setting and alignment for 100 to 160 KVA DG set complete all as specified and directed.
M & L for renewal of Magnetic Pickup suitable for 100 KVA & 200 KVA DG set complete all as specified and directed. Make:- Cummins / KIRLOSKAR / GREAVES COTTON
S&F in renewal Shut down valve solenoid suitable for all capacities of DG set complete all as specified and directed.
S&F in renewal Thermostat of suitable for all capacities of DG set complete all as specified and directed.
S&F in renewal Diaphramg coupling for DG set upto 62.5 KVA capacity complete all as specified and directed.
S&F in renewal Hose Sil D100 X 90 for DG set upto 200 KVA capacity complete all as specified and directed.
S&F in renewal Air Cleaner Assembly for DG set upto 62.5 KVA capacity complete all as specified and directed.
S&F in renewal for copper Battery lead of 25 Sqmm, 2mtr long suitable for all capacities of DG set complete all as specified and directed.
S&F in renewal Feed pump suitable for all capacities of DG set complete all as specified and directed.
S&F in renewal Injector assembly of DG Set of capacity for 62.5 KVA to 200 KVA complete all as specified and directed.
S&F in renewal V Belt / Fan belt suitable for all capacities of DG set complete all as specified and directed.
S&F in renewal Diesel pipe suitable for all capacities of DG set complete all as specified and directed.
S&F in renewal Hose Flexible suitable for for all capacities of DG set complete all as specified and directed
M&L for disconnecting, dismantling and overhauling of fuel injector pump of DG set capacity 15 KVA to 82.5 KVA including overhauling, calibration and testing at admissible pressure properly complete all as specified and directed.
Supply & fix in renewal Nozzle for 15 KVA to 82.5 KVA capacity DG set complete all as specified and directed.
Supply & fix in renewal F.I.P. Elements for 15 KVA to 82.5 KVA capacity DG set complete all as specified and directed.
Supply & fix in renewal Delivery valve for 15 KVA to 82.5 KVA capacity DG set complete all as specified and directed.
M&L for disconnecting, dismantling and overhauling of fuel injector pump of DG set of capacity 100 KVA to 200 KVA including repair, overhauling, calibration, testing complete and refixing to its original position properly complete all as specified and directed. Note:- FIP shall be calibrated by authorised work shop of manufacturer company Contractor has to submit documentary evidense for over hauling carried out from authorised work shop.
Supply & fix in renewal Nozzle & Holder Assembly of DG Set capacity 100 KVA to 200 KVA complete all as specified and directed.
Supply & fix in renewal Gear Drive Injection pump of DG Set capacity 100 KVA to 200 KVA complete all as specified and directed.
Supply & fix in renewal Gasket injection pump mount of DG Set capacity 100 KVA to 200 KVA complete all as specified and directed.
Supply & fix in renewal of A.V.R suitable for 20 KVA to 200 KVA capacity DG set complete all as specified and directed. Make:- KIRLOSKAR / AE / NATIONAL.
M & L for dismantling of defective water pump assembly by disconnecting of hose pipe connections, fanbelt, radiator connection and supply and fixing of new water pump assembly suitable for DG set capacity for 40 KVA to 200 KVA including renewal of u/s hose pipes, fan belt, nut/bolts etc complete all as specified and directed. Make:-- KIRLOSKAR / Cummins / GREAVES COTTON
Supply & fix in renewal solenoid stopper ( solenoid fuel pump ) for FIP pump of 40 KVA to 200 KVA capacity DG set complete all as specified and directed. Make :--Cummins / Kirloskar or equivalent as approved.
Supply & fix in renewal fully automatic battery charger (input 230V AC SMPS based and out put 24V DC) for 24 volt battery complete all as specified and directed. Make :- KIRLOSKAR / ELECT INDIA / Cummins / UNITEK INDIA .
Supply & fix in renewal fully automatic battery charger (input 230V AC SMPS based and out put 12V DC) for 12 volt battery complete all as specified and directed. Make :- KIRLOSKAR / ELECT INDIA / Cummins / UNITEK INDIA
Supply & fix in renewal of maintenance free type battery- 12 Volts,180 AH for DG set of suitable capacity complete all as specified and directed with 18 month replacement warrantty Make: EXIDE / AMARON / or equillvant as approved.
Supply & fixing in renewal of maintenance free type battery- 12 Volts,150 AH for DG set of suitable capacity complete all as specified and directed with 18 month replacement warranty. Make: EXIDE / AMARON / or equillvant as approved.
M&L for checking of AMF panel & DG set for detecting any kind of fault and attending the fault immediately at any time round the clock and carry out certain repair as per site requirement and checking of AMF panel and DG set for power suply from DG set through AMF panel and replace the worn out parts of AMF panel & DG set by expert engineer complete all as specified and directed. Notes :- Note: (a) Replaced worn out parts of AMF panel/DG set shall be measured and paid separately under relevant items of schedule 'A'. (b) Charges for detecting the fault in AMF Panel/electric system/DG set are included in the quoted item rate.
M & L for shifting of trolly mounted DG set up to 250 KVA from one location to another location (with in 05 kilometer) complete including after disconnection of cable connection, earth strip including transportation with using necessary chain pulley & HYDRAULIC jack etc including necessary cable connection and earth strip and other etc. at new location complete all as specified and directed.
S & F in renewal Genset Controller Panel suitable upto 125 KVA capacity DG Set, make and model of Genset controller panel shall be as per site or directed by Enginer -in- charge
S & F in renewal Genset Controller Panel suitable DG Set of capacity 125 to 320 KVA make and model Genset controller panel shall be as per site or directed by Enginer -in- charge
Supply & fix in replacement Digital Frequency meter, 96 Sqmm . Make: AE/ National OR Equivalent as approved.
Supply & fix in replacement Indicater lamp with holder set of three colours of R,Y & B (LED type) suitable for DC/AC supply.
Supply & fix in replacement Relay-24 VDC/ 12 VDC / 220 VAC / 240 VAC for AMF panel of DG set. Make: CUMMINS( AX1012821 ) / OMRON / SALZER / PLA OR Equivalent as approved .
Supply & fix in replacement Contactor- 3/4 Pole,150 Amps/ 140 AMPS for 62.5 KVA capacity DG Set AMF panel including replacement of lugs and checking of all connections etc. Make:- LEGRAND ( 4162 66 ) / L &T / SCHNEIDER / C & S .
Supply & fix in replacement Contactor- 3/4 Pole, 225 Amp/ 200 Amp for 125 KVA capacity DG set AMF panel including replacement of lugs and checking of all connections etc. Make:- LEGRAND ( 4162 96 ) / L &T / SCHNEIDER / C & S .
Supply & fix in replacement Contactor of 4 Pole, 250 Amps for AMF PANEL of DG Set with replacement of cable lugs and checking of all connections etc. Make:-SCHNEIDER ( LC1F1504 ) / L &T / C & S .
Supply & fix in replacement Spare Contact Kit for Contactor-250 Amps suitable for 100 KVA to 125 KVA capacity DG set. Make:- L & T ( CS94084) / SCHNEIDER / C & S .
Supply & fix in replacement MCCB, 200 Amp, 4 pole, 36 KA , thermal magnetic adjustable type 415 volts including taking out existing connections, cable lugs etc all as specified and directed. Make:-L & T ( CM94153OOOOAG ) / Legrand / HAVELLS .
Supply & fix in replacement Self Engine Stop Relay Device for 63 KVA to 180 KVA capacity DG set AMF panel . Make: Automation Electronics / Elect India or equivalent as approved.
Supply & fix in replacement AMF Controller device for Auto/ Manual function for 200 KVA to 500 KVA capacity DG set. Make: Automation Electronics / ELECT INDIA OR Equivalent as approved.
Supply & fix in replacement Solenoid stopper ( Solenoid Fuel Pump ) upto 125 KVA capacity DG set . Make:--Cummins ( 3928160 ) / Kirloskar / or Eqivalent as approved.
M & L for dismantling of defective water pump assembly by disconnecting hose pipe connections, fanbelt, radiator connection. Supply and fix new water pump assembly suitable for DG set capacity for 100 KVA to 200 KVA including all connection replacement of u/s hose pipes, fan belt, nut/bolts etc. Make:-- Kirloskar ( KL6.176.05.0.00 ) / Cummins or Eqivalent as approved.
Supply & fix in replacement Electronic Timer, auxilary supply-240 VAC/24 VDC for 125 KVA to 200 KVA DG set. Make: AE/ EAPL / MINILEC
Supply & fix in replacement Undervolt/overvolt relay-ON/OFF delay time (1 to 15 sec ),sensing supply 415 Volt for 63 KVA to 400 KVA capacity DG set. Make-AE/ PIC / MINILEC
Supply & fix in replacement Changeover switch (Open Execution, Front operated) of 200 Amps, 4 Pole, 415 V, 50 Hz. Make: HPL ( BP04004POAV ) / HAVELLS.
Supply & fix in replacement OFF-Load Changeover switch (Side Handle) of 160 Amps, 4 Pole, 415 V, 50 Hz. Make: HAVELLS / HPL or equivalent as approved.
Supply & fix in replacement Rectifier Assembly for 40 KVA to 160 KVA capacity DG set. Make: KIRLOSKAR ( KV280108000) / CUMMINS OR Equivalent as approved.
Supply & fix in replacement Set of Forword and Reverse Diode for 40 KVA to 160 KVA capacity DG set Make: KIRLOSKAR ( F681539000 ) / CUMMINS OR Equivalent as approved .
Supply & fix in replacement Rocker housing assembly suitable for 160 KVA capacity DG Set . MAKE: CUMMINS ( 3044788 ) OR equivalent as approved .
Supply & fix in replacement of Three Phase Multifunction Digital meter . Make: Automation Electronics / HPL / National
Supply & fix in replacement AMF Relay Box for Auto/ Manual function including voltage monitor system and fully auto and manual system for 63 KVA to 110 KVA capacity DG set. Make: AE/ ELECT INDIA OR equivalent as approved.
Supply & fix in replacement Tube injector fuel supply for 100 KVA to 200 KVA capacity DG set. Make: CUMMINS ( 3964706 ) / KIRLOSKAR or equivalent as approved
Supply & fix in replacement CONTROL GOVERNOR ( MECHANICAL GOVERNOR ) for 160 KVA capacity DG set. Make: CUMMINS ( 3037359 ) or equivalent as approved.
M & L for repairing PT pump complete with replacement of drive accessories, plunger and barrel, weight/courier,oil sheets etc including machinery work for 125 KVA to 160 KVA capacity DG set complete all as specified and directed. Note :- PT pump shall be calibrated by authorised workshop of manufacturer company Contractor has to submit documentary evidense for the repairing carried out from the authorised workshop.
Supply & fix shaft governor weight (3006718) for repairing of PT pump for 125 KVA to 160 KVA capacity DG Set complete all as specified and directed.
Supply & fixing oil seal (3006738) for repairing of PT pump for 125 KVA to 160 KVA capacity DG Set complete all as specified and directed.
Supply & fixing gasket set fuel pump (3010242) for repairing of PT pump for 125 KVA to 160 KVA capacity DG Set complete all as specified and directed.
M & L for dismantling turbo charger of DG set engine of capacity 100 KVA to 200 KVA including repair, overhauling, testing complete and fixing to its original position properly complete all as specified and directed:--
S&F in repair Kit Turbo (KIT3801101) for repairing of Turbo charger of the DG set capacity 100 to 200 KVA complete all as specified and directed.
S&F in repair sleeve turbocharger (216802) for repairing of Turbo charger for the DG Set of capacity 100 to 200 KVA complete all as specified and directed.
M & L for dismantling and replacement of Injector assembly (3239796) for the DG set of capacity 62.5 KVA to 200 KVA complete all as specified and directed.
Taking out alternator of DG Set of capacity 125 KVA to 200 KVA of any make, including material of labour for rewinding with super enamelled copper wire of suitable gauge, varnishing, changing insulating material, assembling, testing and connecting to DG set complete all as specified and directed by Engr-in-Charge Note:- Rates quoted by contractor deemed to be included the rates for tranportation of alternator from site to workshop.
M&L for Field coil rewinding of alternator of 125 KVA to 200 KVA capacity DG sets of any make, rewinding with super enamelled copper wire of suitable gauge, varnishing, changing insulating material, assembling, testing and connecting to DG set complete all as specified and directed by Engr-in-Charge Note:- Rates quoted by contractor deemed to be included the rates for tranportation of alternator from site to workshop.
Taking out alternator of 62.5 KVA to 100 KVA capacity DG sets of any make, including material of labour for rewinding with super enamelled copper wire of suitable gauge, varnishing, changing insulating material, assembling, testing and connecting to DG set complete all as specified and directed by Engr-in-Charge Note:- Rates quoted by contractor deemed to be included the rates for tranportation of alternator from site to workshop.
M&L for field coil rewinding of alternator of 62.5 KVA capacity to 100 KVA capacity DG sets of any make, rewinding with super enamelled copper wire of suitable gauge, varnishing, changing insulating material, assembling, testing and connecting to DG set complete all as specified and directed by Engr-in-Charge Note:- Rates quoted by contractor deemed to be included the rates for tranportation of alternator from site to workshop.
Taking out alternator of 20 KVA to 50 KVA capacity DG sets of any make including materials and labour for, rewinding with super enamelled copper wire of suitable gauge, varnishing, changing insulating material, assembling, testing and connecting to DG set complete all as specified and directed by Engr-in-Charge Note:- Rates quoted by contractor deemed to be included the rates for tranportation of alternator from site to workshop.
S&F MCCB 4 Pole Thermal adjustable breaker type of following capacity etc complete all as specified and directed
63 AMP, 16 KA
125 AMP, 25 KA
160 AMP, 25 KA
200 AMP, 25 KA
Supply and Fix or lay in replacement Copper lead single core PVC insulated and sheathed multi stranded copper conductor cable of cross sectional area 16 sqmm laid in trenches or fixed on wall / floor/ poles etc complete all as specified and directed.
Supply and Fix or lay in replacement Copper lead single core PVC insulated and sheathed multi stranded copper conductor cable of cross sectional area 25 sqmm laid in trenches or fixed on wall / floor/ poles etc complete all as specified and directed.
Supply and fix in renewal factory made/fabricated cubical automatic main failure panel indoor type with degree of protection IP-42 conforming to IS-2147, suitable for 62.5KVA capacity DG Set, fabricated by using 14 Gauge CRCA sheet, powder coated comprising of suitable rated copper bus bar,contactors of adequate rating for auto transfer of main/DG supply including, internal wiring with control fuse, provn of connecting incoming and outgoing leads/ bus bar as approved with and including following accessories and testing all as specified and directed :- (i) Master switch for auto/manual/reset/off-01 No. (ii) Digital type multifunctional meter for ampere, voltage, power factor, frequency etc -01 No. (iii) Push button start, stop, reset-01 No. (iv) Set of lamp for indicating load a set, low pressure, high cylinder temperature, load on mains, set fails at start, low oil presure. (v) Battery charger connection to load. (vi) Transformer of adequate rating. (vii) Ractifiers
(viii) DC ampere meter and voltmeter. (ix) Fault accept / reset push button. (x) Set of relays and contactor 100 Amp suitable for 62.5KVA DG Set for automatic start and automatically shut down of suitable rating and capacity and 2 Nos, MCCB 4 pole, 100 Amp, 25 KA, thermal adjustable type of range 70-100% fixed on main supply and DG set supply. (xi) Make of AMF control panel and drawing will be approved by accepting Officer before placing the order.
Supply and fix factory made/fabricated cubical automatic main failure panel indoor type with degree of protection IP-42 conforming to IS-2147, suitable for 40 KVA capacity DG Set, fabricated using 14 Gauge CRCA sheet, powder coated comprising of suitable rated copper bus bar,contactors of adequate rating for auto transfer of main/DG supply including, internal wiring with control fuse, provn of connecting incoming and outgoing leads/ bus bar as approved with and including following accessories and testing all as specified and directed :- (i) Master switch for auto/manual/reset/off-01 No. (ii) Digital type multifunctional meter for ampere, voltage, power factor, frequency etc -01 No. (iii) Push button start, stop, reset-01 No. (iv) Set of lamp for indicating load a set, low pressure, high cylinder temperature, load on mains, set fails at start, low oil presure. (v) Battery charger connection to load. (vi) Transformer of adequate rating.
(vii) Ractifiers (viii) DC ampere meter and voltmeter. (ix) Fault accept / reset push button. (x) Set of relays and contactor 100 Amp suitable for 62.5KVA DG Set for automatic start and automatically shut down of suitable rating and capacity and 2 Nos, MCCB 4 pole, 100 Amp, 25 KA, thermal adjustable type of range 70-100% fixed on main supply and DG set supply. (xi) Make of AMF control panel and drawing will be approved by accepting Officer before placing the order.
Supply & Lay and testing XLPE PVC insulated and sheathed LT UG cable, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor cross sectional area 120 Sqmm 3.5 core confirming to IS 7098 (Part-I) laid in trenches or fixed on wall/floor/poles including taking down of old XLPE cable complete all as specified and directed.
Supply & Lay and testing XLPE PVC insulated and sheathed LT UG cable, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor cross sectional area 95 Sqmm 3.5 core confirming to IS 7098 (Part-I) laid in trenches or fixed on wall/floor/poles including taking down of old XLPE cable complete all as specified and directed.
Supply & Lay and testing XLPE PVC insulated sheathed LT UG cable, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of cross sectional area 70 Sqmm 3.5 core confirming to IS 7098 (Part-I) laid in trenches or fixed on wall/floor/poles including taking down of old XLPE cable complete all as specified and directed.
Excacation in trenches in soft/loose soil n. exc 1.5 m wide and n. exc. 1.5 m in depth for laying cables and etc complete all as specified and directed.
Return filling in including spreading, leveling, watering and well ramming in layers n. exc. 25cm thick in soft/loose soil after cable are laid and tested complete all as specified and directed.
Removing excavated surplus (soil) to a distance n. exc. 50m and deposited where directed at a level n. exc.1.5m above the starting point complete all as specified and directed.
M&L for sand filing with clean dry fine river sand unsashed including gently punning around cables in trenches for cable protection complete all specified and directed. Note : punned thickness shall be measused and paid.
Supply & Laying sub class 'B' bricks (old size) with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed.
rohan traders
M/s KCL Engines and Machines
Balaji Associate
MUKTA AND COMPANY
Shri Electrical Enterprises
LAXMI ENTERPRISES
BHARADWAJ BROTHERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .