| 1 | L1₹5.1 CrAccepted-AOC | ₹5.1 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹5.2 Cr+₹8.2 L (1.59%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | ₹5.2 Cr+₹8.2 L (1.59%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹5.4 Cr+₹22.5 L (4.37%)Rejected-Finance | ₹5.4 Cr+₹22.5 L (4.37%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹5.4 Cr+₹27.4 L (5.32%)Rejected-Finance B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | ₹5.4 Cr+₹27.4 L (5.32%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹6.0 Cr+₹87.0 L (16.9%)Rejected-Finance | ₹6.0 Cr+₹87.0 L (16.9%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹4.8 Cr
EMD Value
₹5.5 L
Closing Date
14 Jan 2023, 6:00 pmClosed
Chief Engineer Pune Zone
Chief Engineer Pune Zone Dakshin Kaman Marg CAMP, Pune PIN- 411001
PROVISION OF GARAGES AT KALINA MUMBAI
2022_MES_563091_1
CA NO. CEPZ/MUM/TOKEN-09 OF 2022-23
Open Tender
Civil Works
Lump-sum
750 days
Santacruz
Class A and Category a(i)
Also refer NIT
8 documents required · 8 mandatory
₹2,000
GE (North) Santacruz, Mumbai
₹5.5 L
Yes
9 Mar 2023
14 Nov 2022
16 Jan 2023
15 Nov 2022
14 Jan 2023
31 Dec 2022
15 Nov 2022 - 5 Dec 2022
Amount
SCH 'A' PART-I: BUILDING/STRUCTURES Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 5 signifies this fact only.
Construction of Block of covered parking shed for 09 numbers vehicles (Lorry 5/7.5 Ton Stallion) complete all as shown in drawings and as specified.
Construction of Block of covered parking shed for 06 numbers vehicles (ADFCR) complete all as shown in drawings and as specified.
Construction of Block of covered parking shed for 03 numbers vehicles (ADFCR) complete all as shown in drawings and as specified.
NOTE: Schedule ‘A’ Part II to VIII items which are Prepriced by MES, Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Total amount of Sch 'A' Part-II (Internal Electrification)
Total amount of Sch 'A' Part-III (Road and Hardstanding)
Total amount of Sch 'A' Part-IV (Area Drainage)
Total amount of Sch 'A' Part-V (External Electrification)
Total amount of Sch 'A' Part-VI (Lightening Protection)
Total amount of Sch 'A' Part-VII (Demolition / Dismantling)
Total amount of Sch 'A' Part-VIII (Site Clearance, Excavation and Earthwork)
NOTE: Schedule ‘A’ Part II to VIII items, which are not Prepriced by MES are given in Sch 'A' Part-IX hereunder, Bidders shall insert their rate in Column-6 only and the Estimated rate indicated as "0.0" are for that purpose.
SCHEDULE 'A' PART-IX (MISC B/R AND E/M WORKS)
S&F LED light fittings 80 Watt LED having system efficiency 140 lumen per watt, made up of pressure die cast aluminium housing having a LED life with LM70B50 criteria 100000 burning hours with in built surge protection of 4 Kv, CCT 5700 K, and IK07 rating THD < 10%, CCT 5700 K, CRI 70 with IP 65 Potted driver 440 V Operations for 8 Hrs, with and including mounting brackets, clamps, nuts, bolts, washers for fixing etc. complete all as specified and directed. (Make: Wipro Cat No LH21-122-060-57-XX, 80 Watt or equivalent model in the makes given in Appendix 'C').
S&F LED Street light fitting 60 watt 230 Volt AC outdoor type with high pressure die cast aluminium housing and heat resistance cover complete with driver, lamp bracket with impact and corrosion resistance including thermal management in multiple optics complete with IP 65/66 protection, all accessories including providing and connection with and including copper conductor flexible cord of suitable cross sectional area of required length from ceiling rose to connector block of fitting complete including testing on completion all as specified and directed by Engineer-in-Charge. (Make: Philips Cat No. BRP032 LED60 CW SLR GR PSU or Crompton Cat No. TRP-409-60-57-SL-GL-NSG or Bajaj Cat No ENXT P54L WH CR PC SD or equivalent model in the makes given in Appendix 'C').
S&F LED Street light fitting 35/ 36 watt 230 Volt AC outdoor type with high pressure die cast aluminium housing and heat resistance cover complete with driver, lamp bracket with impact and corrosion resistance including thermal management in multiple optics complete with IP 65/66 protection, all accessories including providing and connection with and including copper conductor flexible cord of suitable cross sectional area of required length from ceiling rose to connector block of fitting complete including testing on completion all as specified and directed by Engineer-in-Charge. (Make of fitting: Philips Cat No BRP030 LED35 CW MR PSU GR DX/ Bajaj Cat No. ENXT P35L WH PO PC SD/ Crompton Cat No. TRP-400-35-57-SL-LM-NSR or equivalent model in the makes given in Appendix 'C').
S&F Street light brackets made out of 40 mm dia GI light grade pipe duly bend by hot forging after filling of sand of length 1.50 metre including two pairs of MS flat iron strip 35 mm x 4 mm clamp of suitable size with necessary GI nuts, bolts 75 mm long 12 mm dia - 4 Nos with flat washers 3 mm thick - 4 Nos including painting with aluminium paint over one coat of red oxide primer to the MS clamps and bracket etc. complete and fixing on walls / poles complete all as specified and directed.
S&F Distribution board double door sheet metal enclosure, factory made, fixed inside in wall nitches, for mounting MCB's 230 Volt with bus bar with front openable cover single pole and neutral 6 way, IP 43 protection, complete all as specified and directed.
S&F MCB SPN 20 Amp rating 240 volts 10 KA,'C' curve, in the MCB DB complete with connection, testing and commissioning, complete all as specified and directed.
M&L Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected with and including galvanised earth lead wire 4.0 mm dia by means of bolts, nuts & check nuts and washers etc; GI pipe 15 mm dia medium grade for protection of G.I earth lead wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1:3:6 type C-1 earth pit chamber with M.S angle iron frame, precast reinforced 1: 2 : 4 type B-1 cover with locking arrangement, with G.I 20 mm dia light grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion, complete all as specified and as directed. (Note : GI earth wire & GI pipe 15 mm bore medium grade for encasing GI wire beyond 7.50m length per earthing if so required at site shall be measured & paid separately).
M&L Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected with and including galvanised earth strip 32 mm x 6 mm by means of bolts, nuts & check nuts and washers etc; GI pipe 40 mm dia medium grade for protection of G.I earth lead strip, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1:3:6 type C-1 earth pit chamber with M.S angle iron frame, precast reinforced 1: 2 : 4 type B-1 cover with locking arrangement, with G.I 20 mm dia light grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion, complete all as specified and as directed. (Note : GI earth strip & GI pipe 40 mm bore medium grade for encasing GI strip beyond 7.50m length per earthing if so required at site shall be measured & paid separately).
M & L for river sand cushioning (dry) in trenches for protection of UG cable (below above and around the UG cable laid in trenches ) of 23 cm spread thickness (8 cm in depth before laying the cable and 15 cm in depth after laying the cable) and consolidated (punned) up to 18 cm thickness complete all as specified and directed. Note: Punned thickness will be considered for payment purpose.
Supply and fix sub class B brick well burnt, laid breadth-wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as directed.
Supplying, laying, jointing, testing & commissioning LT Cables, 1100 volts grade, XLPE insulated, armoured & PVC sheathed with stranded aluminium conductor, heavy duty conforming to IS 7098 Part I, ISI marked to be laid in trenches or fixed along the poles or drawn through GI pipes, laid under floors, road etc., fixed concealed in walls, encased in GI pipe complete all as specified and directed of following sizes:-
Cross sectional area 3 ½ core 50 sq.mm.
Cross sectional area 3 ½ core 35 sq.mm.
Cross sectional area 4 core 25 sq.mm.
Cross sectional area 2 core 25 sq.mm.
Cross sectional area 2 core 16 sq.mm.
Cross sectional area 2 core 10 sq.mm.
S & F Thermo plastic street light junction box of size 240 x 130 x 95 mm, top hinged or equivalent with and including MCB SP 6 Amp 'C' curve mounted on din rail inside the box and connecting terminal 4 way, fixed on steel street light pole with and including MS nuts bolt and MS clamps -1 No of size 40 mm x 4 mm thick, complete all as specified and directed.
M&L for Cutting through existing bituminous road / PCC floor/ hard standing of approximate size 45 cm x 45 cm depth along length for laying of GI tubing / RCC pipe for encasing of cable and repairing the disturbed road surface by filling excavated materials and top 200 mm depth filled with and including PCC 1:3:^ type C-1 using 20 mm graded stone aggregates and finish fair and even, complete all as specified and directed.
S&F LED street light fitting 70 Watt capacity separate individual peanut plated Lens and aluminium reflectors housing should be made of LM6 Pressure die cast aluminium housing with optical cover should be only toughened glass, impact resistance > IK07/ IK08, IP protection not less than IP-65/ IP66, protection should be class I, vibration should be as per IEC-60598, product standard IS-10322 / IEC-60598, all the component such as driver, surge protection should also be of same make, driver should be moulded type with operating voltage should be 140 V - 270 V, driver frequency 50 Hz, power factor > 0.9, lumen output should not be less than 120 lumen / watt and luminaire driver kit should be moulded type weather proof construction with separate surge protection device 4/ 5 ka rating and separate connector block for termination of incoming cable connection all as specified and directed. (Make: Philips Cat part No BRP032 LED70 CW SLR GR PSU or Havells Cat No. ENDURAOMNIPLUSSL70WLED757SASYTOPC or Crompton Cat No. CRP-70-57-SL-GL-NSG or equivalent make given in Appendix 'C') including testing on completion, all as specified and as directed.
Dismantling existing LT steel tubular poles of any type and size carefully including street light fittings etc. and handing over the same to AGE E/M store yard for keeping in safe custody for reuse including demolition of PCC foundation and coping and making good disturbed ground, all as specified and directed.
S&F MCCB 4 Pole 32 Amp 415 V, 50 Hz with rupturing capacity 16 KA thermal magnetic release, adjustable over load (0.7 to 1) and short circuit protection IS 13947-2/IEC 60947-2, fixed in existing panel in Sub Station for taking connection to proposed LT Panel No. 1 at Sub Station, complete all as specified and directed.
S&F 3 core PVC insulated and sheathed 1100 Volts grade multicore cable 1.50 sq.mm with stranded copper conductor cable drawn inside the pole where required with making necessary holes on bottom and top of pole from looping box to security light fitting, complete all as specified and directed.
Supply, installation, testing and commissioning weather, dust and vermin proof, outdoor type, floor mounted, CPRI Approved type tested LT feeder pillar box of suitable size, factory fabricated, totally enclosed, front opening type, suitable for 415 Volts, 3 phase, 4 wire, 50 Hz AC supply, IP-54 class protection, made out of 3.15 mm thick CRCA sheet metal outer and 1.60 mm thick for inner compartments conforming to IS: 8623, panel shall be of suitable size for housing bus bars, LT switchgears and measuring instruments and duly powder coated after seven tank process on both sides, frame made out of MS angle iron frame made out of 50x50x6 mm cut to size, welded, bent to shape, cubical fabricated truly to box type, hinged panel board opening handles, locking arrangements, provided with sufficient circular holes at the bottom sheet for entry of plated cable glands and aluminium lugs suitable for incoming and outgoing cables, provided with PVC rubber bushes to spare holes, including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 volts grade IS 694-2010 marked or PVC sleeved copper strips of appropriate sizes but not less than 2.50 Sqmm, including provision of PCC platform and grouting panel legs in PCC block so that the bottom of panel shall be at minimum 45 cm above ground level, all accessories prewired complete with danger notice board with and including the following controls and accessories:-
(a) Aluminium bus bar 100 Amp capacity for Phase-R-Y-B and for neutral mounted on epoxy based insulator installed with coloured sleeves - 01 Set (3 Phase and neutral)
(b) Incoming - 4 Pole MCCB 32 Amp, 50 Hz, 415 volt with rupturing capacity 25 KA with adjustable thermal and magnetic settings - 01 No
(c) Outgoing- MCCB 4 pole 415 Volt 20 Amp rating with thermal and magnetic settings, 50 Hz, breaking capacity 10 KA - 01 No
(d) MCCB 2 pole 415 Volt 16 Amp rating with thermal and magnetic settings, 50 Hz, breaking capacity 10 KA - 02 No
(e) Digital type multifunctional meter CT operated class 1 accuracy suitable for measuring v, A, PF, kW, kva etc. 3 phase 4 digit high resolution, LED type with one side programmability - 01 No
(f) LED type phase indicator lamp of Red, Yellow and Blue with holder key, flush mounted with toggle switch - 01 Set of 03 lamps
(g) CT 50 / 5 A - 03 Nos.
(h) Panel wiring with suitable capacity of copper conductor cables of 1100 V grade.
(j) PCC foundation 1:2:4 type B-1 of suitable size as directed by Engineer-in-Charge.
Supply, installation, testing and commissioning weather, dust and vermin proof, outdoor type, floor mounted, CPRI Approved type tested LT feeder pillar box of suitable size, factory fabricated, totally enclosed, front opening type, suitable for 415 Volts, 3 phase, 4 wire, 50 Hz AC supply, IP-54 class protection, made out of 3.15 mm thick CRCA sheet metal outer and 1.60 mm thick for inner compartments conforming to IS: 8623, panel shall be of suitable size for housing bus bars, LT switchgears and measuring instruments and duly powder coated after seven tank process on both sides, frame made out of MS angle iron frame made out of 50x50x6 mm cut to size, welded, bent to shape, cubical fabricated truly to box type, hinged panel board opening handles, locking arrangements, provided with sufficient circular holes at the bottom sheet for entry of plated cable glands and aluminium lugs suitable for incoming and outgoing cables, provided with PVC rubber bushes to spare holes, including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 volts grade IS 694-2010 marked or PVC sleeved copper strips of appropriate sizes but not less than 2.50 Sqmm, including provision of PCC platform and grouting panel legs in PCC block so that the bottom of panel shall be at minimum 45 cm above ground level, all accessories prewired complete with danger notice board with and including the following controls and accessories:-
(a) Aluminium bus bar 100 Amp capacity for Phase-R-Y-B and for neutral mounted on epoxy based insulator installed with coloured sleeves - 01 Set (3 Phase and neutral)
(b) Incoming - 4 Pole MCCB 20 Amp, 50 Hz, 415 volt with rupturing capacity 16 KA with adjustable thermal and magnetic settings - 01 No
(c) Outgoing- MCCB 4 pole 415 Volt 16 Amp rating with thermal and magnetic settings, 50 Hz, breaking capacity 16 KA - 01 No
(d) MCCB 2 pole 415 Volt 16 Amp rating with thermal and magnetic settings, 50 Hz, breaking capacity 10 KA - 02 No
(e) Digital type multifunctional meter CT operated class 1 accuracy suitable for measuring v, A, PF, kW, kva etc. 3 phase 4 digit high resolution, LED type with one side programmability - 01 No
(f) Time switches Astro type (having longitudinal and latitude of Indian cities in memory) 250 V, power contactor 2 pole AC with 230 V coil 9 Amp rating, MNX, fitted inside steel enclosure - 01 No
(g) LED type phase indicator lamp of Red, Yellow and Blue with holder key, flush mounted with toggle switch - 01 Set of 03 lamps
(h) CT 50 / 5 A - 03 Nos.
(j) Panel wiring with suitable capacity of copper conductor cables of 1100 V grade.
(k) PCC foundation 1:2:4 type B-1 of suitable size as directed by Engineer-in-Charge.
NOTES FOR ITEM No 27.00 AND 28.00:
(i) Panel shall be manufactured by the reputed manufacturer who is possession of type test certificate by CPRI not older than ten years.
(ii) Rate quoted shall be inclusive of complete excavation and earthwork in any kind of soil as per site requirement.
M/s Shree Construction Co
DARSHAN CONSTRUCTION Co.
Vishal Builders
haresh n hingorani
Modern Engineering Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .