| Sl No | Description | Qty | Unit | M/S JAIN ELECTRIC CONTRACTOR L3 | M/S SAI TRADERS L1 | ANSHIKA ENTERPRISES L2 |
|---|---|---|---|---|---|---|
| 1.00fo|qr forj.k [k.M&izFke cMkSr ds v/khu 33@11 dsoh midsUnzksa ij LFkkfir fofHkUu esd dh 33 dsoh ,oa 11 dsoh oh0lh0ch0 esa mRiUu bySfDVªdy ,oa eSdsfudy nks’k dks ejEer djkus ls lEcfU/kr dk;ZA | ||||||
| 2.00 | In Case Of Emergancy Break Down Complete Overhauling of 11 KV VCB Including Mechanical & Electrical Work as per requirement with complete work in all respect. | 12 | Job | 6,000 ₹72,000 | 7,000 ₹84,000 | 4,500 ₹54,000 |
| 3.00 | Providing of 2.5 Sqmm. PVC Copper Wire, Lugs Etc. And Replacement Of Damaged/Burnt Wiring Complete Of 11 KV VCB as per requirement with complete work in all respect. (All material shall be high quality and PVVNL Approved) | 20 | Job | 5,000 ₹1 L | 2,500 ₹50,000 | 2,000 ₹40,000 |
| 4.00 | Providing & Fixing Of Damaged Closing Coil and Complete Overhaluing Of 11 KV VCB as per requirement with complete work in all respect. (All material shall be high quality and PVVNL Approved) | 12 | Nos | 3,000 ₹36,000 | 2,500 ₹30,000 | 2,000 ₹24,000 |
| 5.00 | Providing & Fixing Of Damaged Triping Coil and Complete Overhaluing Of 11 KV VCB as per requirement with complete work in all respect. (All material shall be high quality and PVVNL Approved) | 35 | Nos | 1,500 ₹52,500 | 2,000 ₹70,000 | 3,000 ₹1.1 L |
| 6.00 | Providing And Fixing Local Remote Switch 11 KV VCB as per requirement with complete work in all respect. (All material shall be high quality and PVVNL Approved) | 8 | Nos | 2,000 ₹16,000 | 1,500 ₹12,000 | 500 ₹4,000 |
| 7.00 | Repairing & Overhauling Of Kit-Kat Fuse Complete & Proper Connection as per requirement with complete work in all respect. (All material shall be high quality and PVVNL Approved) | 12 | Job | 2,000 ₹24,000 | 200 ₹2,400 | 100 ₹1,200 |
| 8.00 | Repairing & Overhauling Of OC/EF Main Relay (33 & 11 KV) as per requirement with complete work in all respect. (All material shall be high quality and PVVNL Approved) | 7 | Job | 1,000 ₹7,000 | 11,000 ₹77,000 | 10,000 ₹70,000 |
| 9.00 | Providing And Replacement Of Master Trip Relay as per requirement with complete work in all respect. (All material shall be PVVNL Approved) | 3 | Job | 1,000 ₹3,000 | 6,000 ₹18,000 | 5,000 ₹15,000 |
| 10.00 | Providing And Fixing Of 2.5 sqmm. 04 Core Cable as per requirement with complete work in all respect. (All material shall be PVVNL Approved) | 100 | Mtr. | 1,000 ₹1 L | 240 ₹24,000 | 260 ₹26,000 |
Tender Value
₹6 L
EMD Value
₹6,000
Closing Date
30 Apr 2026, 12:00 pmClosed
SUPERINTENDING ENGINEER
SUPERINTENDING ENGINEER EDC BAGHPAT
REMOVAL OF ELECTRICAL AND MECHANICAL FAULT OF VCB INSTALLED UNDER EDD-1 BARAUT
2026_PVVNL_1139648_1
06/2026-27/EDC-BAGHPAT
Open Tender
Electrical Works
EDD-I BARAUT
AS PER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹1,180
Yes
SUPERINTENDING ENGINEER
₹6,000
Yes
11 May 2026
20 Apr 2026
30 Apr 2026
20 Apr 2026
30 Apr 2026
20 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | fo|qr forj.k [k.M&izFke cMkSr ds v/khu 33@11 dsoh midsUnzksa ij LFkkfir fofHkUu esd dh 33 dsoh ,oa 11 dsoh oh0lh0ch0 esa mRiUu bySfDVªdy ,oa eSdsfudy nks’k dks ejEer djkus ls lEcfU/kr dk;ZA | - | - | - | - |
| 2 | In Case Of Emergancy Break Down Complete Overhauling of 11 KV VCB Including Mechanical & Electrical Work as per requirement with complete work in all respect. | 12 | Job | - | - |
| 3 | Providing of 2.5 Sqmm. PVC Copper Wire, Lugs Etc. And Replacement Of Damaged/Burnt Wiring Complete Of 11 KV VCB as per requirement with complete work in all respect. (All material shall be high quality and PVVNL Approved) | 20 | Job | - | - |
| 4 | Providing & Fixing Of Damaged Closing Coil and Complete Overhaluing Of 11 KV VCB as per requirement with complete work in all respect. (All material shall be high quality and PVVNL Approved) | 12 | Nos | - | - |
| 5 | Providing & Fixing Of Damaged Triping Coil and Complete Overhaluing Of 11 KV VCB as per requirement with complete work in all respect. (All material shall be high quality and PVVNL Approved) | 35 | Nos | - | - |
| 6 | Providing And Fixing Local Remote Switch 11 KV VCB as per requirement with complete work in all respect. (All material shall be high quality and PVVNL Approved) | 8 | Nos | - | - |
| 7 | Repairing & Overhauling Of Kit-Kat Fuse Complete & Proper Connection as per requirement with complete work in all respect. (All material shall be high quality and PVVNL Approved) | 12 | Job | - | - |
| 8 | Repairing & Overhauling Of OC/EF Main Relay (33 & 11 KV) as per requirement with complete work in all respect. (All material shall be high quality and PVVNL Approved) | 7 | Job | - | - |
| 9 | Providing And Replacement Of Master Trip Relay as per requirement with complete work in all respect. (All material shall be PVVNL Approved) | 3 | Job | - | - |
| 10 | Providing And Fixing Of 2.5 sqmm. 04 Core Cable as per requirement with complete work in all respect. (All material shall be PVVNL Approved) | 100 | Mtr. | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.05 MB
BOQ_2127885.xls
BOQ • 0.30 MB
tenderdocuments6.pdf
Tender Documents • 1.53 MB
Download all tender documents and submit your bid