Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC | ₹13.1 L Quoted ₹13.7 L | L1 | Accepted-AOC Awarded |
| 2 | L2₹16.5 L+₹2.8 L (20.4%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | ₹16.5 L+₹2.8 L (20.4%) | L2 | Rejected-Finance Rejected |
| 3 | L3₹17.3 L+₹3.6 L (26.3%)Rejected-Finance | ₹17.3 L+₹3.6 L (26.3%) | L3 | Rejected-Finance Rejected |
| 4 | L4₹18.8 L+₹5.1 L (37.0%)Rejected-Finance | ₹18.8 L+₹5.1 L (37.0%) | L4 | Rejected-Finance Rejected |
Tender Value
₹32.2 L
EMD Value
₹64,340
Closing Date
1 Jun 2023, 6:00 pmClosed
GE (AF) Subroto Park
GE (AF) Subroto Park c o 56 APO
REPAIIR/ REPLACEMENT OF UG CABLES/ LT PANELS WITH FENCING/EARTHING AND CERTAIN ALLIED WORKS OF SPE OMQ AREA UNDER GE(AF) SUBROTO PARK, REPAIR MAINTENANCE OF LT PANELS AND CERTAIN ALLIED WORKS UNDER GE AF SUBROTO PARK AND REPAIR MAINT OF SEC
2023_MES_587658_2
GE/SP/ TOKEN-56/2022-23
Open Tender
Civil Works
Item Rate
180 days
Subroto Park Delhi Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) Subroto Park
₹64,340
Yes
21 Jul 2023
12 May 2023
8 Jun 2023
12 May 2023
1 Jun 2023
20 May 2023
Amount
Taking down carefully the existing point wiring of any size/capacity and type by disconnecting from the terminals complete including fittings and fixtures such as switches, sockets,ceiling rose, regulators and light fittings etc by unscrewing and removing from site complete all as specified and directed by engg-in-charge. Note :cost of unserviceable materials will be charged from the contractor against schedule of credit.
M & L for point wiring with 1.5 sqmm (Nominal Area)PVC insulated un sheathed multi stranded copper conductor,FRLS 1100 Volts grade, with non metalic rigid PVC medium grade conduit in wall/roof not less than 20mm dia with accessories such as junction boxes, bends, tees etc. of suitable size including sunk cast iron or pressed steel terminal box for mounting switches, sockets fan regulators etc with 3 mm thick plastic laminated sheet top cover including continuous earth wire PVC insulated 1.50 Sq mm multi stranded copper conductor, FRLS 1100 Volts grade, connecting to common earth and earth dolly complete all as specified for One light /bell/fan point controlled by one 1 way switch
All as per Item No 2 herien before but One three pin switch socket 5 Amps plug point on independent board
All as per Item No 2 herien before but One three pin switch socket 5 Amps plug point on same board
All as per Item No 2 herien before but One bell/buzzer point controlled by one bell push on independent board
All as per item No 2 herein before but point wiring with 2.5 Sqmm single core multi stranded copper conductor for one three pin socket 15 Amps on independant board controlled by one 15 Amps Switch including continuous earth wire PVC insulated 2.5 Sqmm single core multi stranded copper conductor connected to common earth dolly.
M&L for point wiring with single core of FRLS PVC insulated unsheathed ISI marked 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC conduit size of not less than 20mm including conduit fittings and acessories concealed in wall / ceiling wiring terminated in flush metal box alongwith outer cover plate for mounting modular switch, socket and electronic regulator along with provn of earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded FRLS ISI marked copper conductor of size 1.5 sqmm all as specified and directed by Engr-in-Charge. For One light point/c fan/ Exh fan controlled by one switch one way.
All as per item No 7 above but for one 3 pin 5 amps socket outlet on indipendent board with other switchs.
All as per item No 7 above but for one 3 pin 5 amps socket outlet on the same board with other switchs.
All as per item No 7 above but for one light point controlled by 2 Nos two way switches.
All as per item No 7 above but for Call bell controled by one push button in indipendent board .
All as per item No 7 above but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including S/C 1.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire connected to gang box of required size.
S&F in replacement switch piano, flush type single pole, two way, 5 Amps, 240 volts all as specified and directed at site.
Supply & fix in replacement of Switch Piano, Flush Button, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed.
Supply & fix in replacement of switch piano, flush type, 15 amps, single pole, one way suitable for 240V AC Complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of modular type socket outlet 2in1, 3 pin 5 Amps flush type suitable for 240V AC Complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of modular type socket outlet 2in1, 3 pin 15/5 Amps flush type suitable for 240V AC Complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of ceiling rose surface type bakelite 65 x 50 mm with three terminals with ISI mark.
Supply & fix in replacement of steped type electronic fan regulator heavy duty flush type complete
Supply & fix in replacement of Bell push flush type 5 Amps.
Supply & fix in replacement of lamp holder PVC/Poly Carbonate type suitable for batten fittings with ISI mark.
Supply & fix in replacement of call bell, Ding dong type, suitable for 240V AC Complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of modular Switch, 5/6 Amps , 1 module,complete all as specified and directed.
Supply & fix in replacement of modular Switch, 5/6 Amps , 1 module,two way complete all as specified and directed.
Supply & fix in replacement of modular socket outlet , 6 Amp, 2/3 pin combined, 2 module complete all as specified and directed.
Supply & fix in replacement of modular Switch, 16 Amps , 1 module,complete all as specified and directed.
Supply & fix in replacement of modular socket outlet , 6/16 Amp, 2/3 pin combined, 2 module complete all as specified and directed.
S&F modular white cover plate with frame 12 module complete.
S&F metal flush mounting boxes 12 modular complete.
S&F modular white cover plate with frame 8 module complete.
S&F metal flush mounting boxes 8 modular complete.
S&F modular white cover plate with frame 6 module complete.
S&F metal flush mounting boxes 6 modular complete.
S&F modular white cover plate with frame 4 module complete.
S&F metal flush mounting boxes 4 modular complete.
S&F modular white cover plate with frame 3 module complete.
S&F metal flush mounting boxes 3 modular complete.
M& L in replacement for Fabricate, supply and install cubicle type, CPRI approved LT panel board,outdoor type, totally enclosed,dust & vermin proof (protection class IP 65) front opening with self locking arrangment made out of MS angle iron frame work, MS flat iron and CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated paint of approved shade. The panel shall be suitable for 415 volts,50 Hz, 3 phase 4 wire system and shall be complete with 300 amp capacity copper bus bar, wiring the panel board with suitable size of PVC insulated, multi stranded copper cables and all connected acessories required for functioning of panel board such as thimbles,glands, bolts, nuts,washers etc including supply and fixing following acessories:- (Infrount bldg No SP-18 PANEL No-6) INCOMING (a) MCCB 320 Amps, 4 pole,36 KA DPX3 630 cat No 422006- 1 No (b) Digital type volt meter - set 01 (c) Digital type ammeter with suitable rating CTs conforms to relevent IS specification,- set 01 (d) LED type indicator lamp set of red , yellow and blue - set 01 OUT GOING (a) MCCB 200 Amps, 4 pole, 36 KA DPX3 250 cat No 420248 - 03 Nos.(SP-15,SP-17 & 18) (b) MCCB 125 Amps, 4 pole, 25 KA DPX3 160 cat No 422006 - 02 Nos (SP-15 (A) & SP-20) Foundation- (i) Plateform for the panelwith PCC 1:2:4 type D-2 with 40mm graded crushed stone 15 cm thick in foundation brick work in 1:6 with sub class"B" old size bricks sith sandering 15mm in CM1:6of exposed surface and 100mm thick PCC padding 1:3:6 type C-1 using 20mm graded crushed stomneaggregate on top plate form shall be such that it is of a height 45cm above nearest road level.
M& L in replacement for Fabricate, supply and install cubicle type, CPRI approved LT panel board,outdoor type, totally enclosed,dust & vermin proof (protection class IP 65) front opening with self locking arrangment made out of MS angle iron frame work, MS flat iron and CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated paint of approved shade. The panel shall be suitable for 415 volts,50 Hz, 3 phase 4 wire system and shall be complete with 300 amp capacity copper bus bar, wiring the panel board with suitable size of PVC insulated, multi stranded copper cables and all connected acessories required for functioning of panel board such as thimbles,glands, bolts, nuts,washers etc including supply and fixing following acessories:-- (Behind SP-16 PANEL No-7) INCOMING (a) MCCB 320 Amps, 4 pole,36 KA DPX3 630 cat No 422006- 1 No (b) Digital type volt meter - set 01 (c) Digital type ammeter with suitable rating CTs conforms to relevent IS specification,- set 01 (d) LED type indicator lamp set of red , yellow and blue - set 01 OUT GOING (a) MCCB 200 Amps, 4 pole, 36 KA DPX3 250 cat No 420248 - 03 Nos.(SP-15,SP-17 & 18) (b) MCCB 125 Amps, 4 pole, 25 KA DPX3 160 cat No 422006 - 02 Nos (SP-15 (A) & SP-20) Foundation- (i) Plateform for the panelwith PCC 1:2:4 type D-2 with 40mm graded crushed stone 15 cm thick in foundation brick work in 1:6 with sub class"B" old size bricks sith sandering 15mm in CM1:6of exposed surface and 100mm thick PCC padding 1:3:6 type C-1 using 20mm graded crushed stomneaggregate on top plate form shall be such that it is of a height 45cm above nearest road level.
M& L in repair for Fabricate, supply and install cubicle type, CPRI approved LT panel board,outdoor type, totally enclosed,dust & vermin proof (protection class IP 65) front opening with self locking arrangment made out of MS angle iron frame work, MS flat iron and CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated paint of approved shade. The panel shall be suitable for 415 volts,50 Hz, 3 phase 4 wire system and shall be complete with 300 amp capacity copper bus bar, wiring the panel board with suitable size of PVC insulated, multi stranded copper cables and all connected acessories required for functioning of panel board such as thimbles,glands, bolts, nuts,washers etc including supply and fixing following acessories:- (Behind SP-14 PANEL No-8) INCOMING (a) MCCB 320 Amps, 4 pole,36 KA DPX3 630 cat No 422006- 1 No (b) Digital type volt meter - set 01 (c) Digital type ammeter with suitable rating CTs conforms to relevent IS specification,- set 01 (d) LED type indicator lamp set of red , yellow and blue - set 01 OUT GOING (a) MCCB 200 Amps, 4 pole, 36 KA DPX3 250 cat No 420248 - 03 Nos.(SP-15,SP-17 & 18) (b) MCCB 125 Amps, 4 pole, 25 KA DPX3 160 cat No 422006 - 02 Nos (SP-15 (A) & SP-20) Foundation- (i) Plateform for the panelwith PCC 1:2:4 type D-2 with 40mm graded crushed stone 15 cm thick in foundation brick work in 1:6 with sub class"B" old size bricks sith sandering 15mm in CM1:6of exposed surface and 100mm thick PCC padding 1:3:6 type C-1 using 20mm graded crushed stomneaggregate on top plate form shall be such that it is of a height 45cm above nearest road level.
Supply,laying, jointing,testing LT cable 25 Sq mm, 4 core 1100 volts grade, PVC insulated armoured and PVC sheathed with stranded aluminium conductor heavy duty, including cable glands, cable lugs etc. to suit the cable size, laid in trenches, fixed along the poles bare or through G.I. Pipe laid under floors road etc; fixed concealed in walls encased in G.I. Pipe etc. complete all as specified and directed.
All as per item No 41 here in before but 95 Sq mm, 3.5 core
All as per item No 41 here in before but 120 Sq mm, 3.5 core
All as per item No 41 here in before but 185 Sq mm, 3.5 core
All as per item No 41 here in before but 240 Sq mm, 3.5 core
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in deep for foundation of pole/stay/cable etc and getting in soft/loose soil complete all as specified and as directed by Engineer-in-charge
Returning refiling including spreading, leveling, watering and well raming in layers each not exceeding 25 cm thickness complete all as specified and as directed by Engineer-in-charge.
Removing surplus spoil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge.
Sand cushioning for under ground cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable all as specified and directed by engineer-in-charge.
Supply and lay well burnt as class ‘B’ bricks as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench all as specified and directed by engineer-in-charge.
Taking down and disconnecting of old unserviceable LT U/G cable of any type and size from various side and removing to store for taking credit (credit for above items should be made as per conditioned separately) Complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply & fix in replacement of sheet metal enclosure with double door category of protection type IP-42 factory made with tinned copper 200 Amps rated bus bar suitable for MCB SPN 240 Volts, 2 way all as specified and directed.
Supply & fix in replacement of sheet metal enclosure with double door category of protection type IP-42 factory made with tinned copper 200 Amps rated bus bar suitable for MCB TPN 415 Volts, 4 way all as specified and directed.
Supply & fix in replacement of MCB/Isolator Triple pole and neutral 63 Amps working on 415 volts 50 Hz AC supply,16 KA .
Supply & fix in replacement of MCB/Isolator single pole and neutral 32/40 Amps working on 240 volts 50 Hz AC supply,10 KA.
Supply & fix in replacement of MCB/Isolator single pole 6 to 32 Amps working on 240 volts 50 Hz AC supply,10 KA.
Supply & fix in replacement of LED Bulb 07/09 watt pin type warm white 2700/3000K
Supply & fix in replacement of LED Bulb 07/09 watt thread type warm white 2700/3000K
Supply & fix in replacement of garden light glove type including LED bulb5/7/9 watt warm white.
Supply & fix in replacement of PVC gang box suitable for one switch and socket 5 Amps complete all as specified and as directed by Engineer in Charge.
S&F in replacement modular fan regulator ,120 W, 2 module complete all as specified and directed.
Supply and fix in replacement of new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection with high power 150 watt LED , 6000K , with electronic driver, general spread of cat Part No 9405 of make Havells and equivelent make of phillips/CG with all accessories pre-wired and electric connection using PVC insulated and sheathed 1100 volts grade cable with copper conductor of size 2.5 sqmm complete with provn of nuts and bolts fixing on walls/poles etc. complete all as specified.
Supply and fix in replacement of new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection with high power 70 watt LED , 6000K , with electronic driver, general spread with all accessories pre-wired and electric connection using PVC insulated and sheathed 1100 volts grade cable with copper conductor of size 2.5 sqmm complete with provn of nuts and bolts fixing on walls/poles etc. complete all as specified.
S&F LED garden light 25 watt post top lantern fittings with powder coated aluminium die cast and spun aluminium body with clear/opal diffuser suitable for landscape lighting available in 5700K CCT,IP65. also availble in 3000K & 4000K on demand of item code No PGR0201008 model PCGLPT 01 25 C of make Polycab or equvilent make of Havells/Phillips all as specified and directed by engineer - in- charge.
Supply & fix in replacement of MCCB four Pole 400 Amps, 415 volt thermal release bearing adjestable type breaking cap 50 KA, comlete all as specified and as directed by Engineer-in-Charge.
Supply & fix in replacement of MCCB four Pole 320/350 Amps, 415 volt thermal release bearing adjestable type breaking cap 36 KA, comlete all as specified and as directed by Engineer-in-Charge.
Supply & fix in replacement of MCCB four Pole 250 Amps, 415 volt thermal release bearing adjestable type breaking cap 36 KA, comlete all as specified and as directed by Engineer-in-Charge.
Supply & fix in replacement of MCCB four Pole 125 Amps, 415 volt thermal release bearing cap 16 KA comlete all as specified and as directed by Engineer-in-Charge.
Supply & fix in replacement of MCCB four Pole 100 Amps, 415 volt thermal release bearing cap 16 KA comlete all as specified and as directed by Engineer-in-Charge.
Supply & fix in replacement of MCB TP, 100 Amps, 10 KA 440 volt 50 Hz all as specified ans directed by engineer in- charge.
Supply & fix in replacement of PVC FRLS Flexible cable copper conductor, unsheathed , 1100 volts grade confirming to IS:694/1990 of size 1.5 sqmm.
Supply & fix in replacement of PVC FRLS Flexible cable copper conductor, unsheathed , 1100 volts grade confirming to IS:694/1990 of size 2.5 sqmm.
Supply & fix in replacement of PVC FRLS Flexible cable copper conductor, unsheathed , 1100 volts grade confirming to IS:694/1990 of size 4.0 sqmm.
Supply & fix in replacement of PVC Flexible cable copper conductor, twin core, 1100 volts grade confirming to IS:694/1990 of size 0.75/1.0 sqmm.
Supply & fix in replacement of flood light 50 watt, high power LED 3000/6000K energy saving, Highly efficient integral type mid power made of pressure die cast aluminium housing with 10 KV SPD, toughned glass, w/o Lens.IP66, suitable for highlighting architectural features orretail spaces complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement of PVC insulated Aluminium conductor twin core service cable ISI marked of size 10 Sqmm each roll of 100 mtr.
Supply & fix in replacement of FRP cable junction boxes including bus bar (04 Nos) with 02 Nos MS clamps of flat 40x6mm suitable size complete with nuts & bolts complete all as specified and as directed by Engineer-in-Charge.
Supply & fix in replacement of aluminium thimble stud type suitable for size of cable 400 sq mm all as specified and directed by engineer-in-charge.
Supply & fix in replacement of aluminium thimble stud type suitable for size of cable 185 sq mm all as specified and directed by engineer-in-charge.
Supply & fix in replacement of aluminium thimble stud type suitable for size of cable 120 sq mm all as specified and directed by engineer-in-charge.
Supply & fix in replacement of aluminium thimble stud type suitable for size of cable 35 sq mm all as specified and directed by engineer-in-charge.
Supply & fix in replacement of PVC exhaust fan 225mm heavy duty plastic body sweep complete all as specified and as directed by Engineer-in-Charge.
Supply & fix in replacement of ceiling fan heavy duty 1200 mm sweep complete all as specified and as directed by Engineer-in-Charge.
Supply & fix in replacement of exhaust/ventilating fan heavy duty plastic body 250 mm sweep complete all as specified and as directed by Engineer-in-Charge.
Supply & fix in replacement of wall mounting fan heavy duty 300/380 mm sweep complete all as specified and as directed by Engineer-in-Charge.
Supply only Insulation Tape 25mm width .
Supply and fixing in replacement load line vertical distribution board 'A, frame made out of CRCA 2mm thick mild steel sheet,double door, surface mounting TPN 4 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable forTP/FP 'A' frame MCCB of 125 Amps =01 No MCB for outgoing comlete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement PVC gang box suitable for one switch 5 Amps complete with screw and necessary arrangement complete all as specified and directed by Engineer in Charge.
S&F in repair of sub main wiring with 2 single core 04 Sq mm PVC insulated unsheathed 1100 V grade copper conductor cable drawing in and incl rigid non metallic PVC conduit 25 mm dia incl 4.0 Sq mm PVC insulated single core copper conductor cable for continuous earth wire.
M & L for rigid non metalic PVC medium grade conduit including junction boxes, tee, bends, elbows, reducers bell mouth tube ends,fixing accessories such as couplers, lock Nuts, saddle pipe hook etc for 25 mm dia.ISI Marked.
Dismantling of unserviceable light fitting of any type and wattage from the buildings after disconnecting the electric supply and keeping in safe custidy complete all as specified and directed.
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,20 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge.
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,10 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, fixed on two PVC round blocks and testing complete all as specified and directed by the Engineer-In- Charge.
Supply and fixing wall mounted LED bulk head fittings, 10 watt, warm white, 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer-In- Charge.
S&F in replacement of exhaust fan heady duty metal body 300 mm sweep including necessary fixing arrangement for proper fixing in wall and making hole as per site requirement complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of exhaust/ventilating fan heady duty metal body type 230 mm sweep including necessary fixing arrangement for proper fixing in wall and making hole as per site requirement complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of exhaust/ventilating fan heavy duty plastic body 250 mm sweep including necessary fixing arrangement for proper fixing in wall and making hole as per site requirement complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of wall mounting fan heady duty 300 mm sweep including necessary fixing arrangement for proper fixing on wall as per site requirement complete all as specified and as directed by Engineer-in-Charge.
Taking down old unsv MCB DB of any size.
S&F LED Bulb 9 watt retrofit type 2700K (Yellow/white colour) complete all as specified.
S&F in replacement of fan capacitor with copper wire plastic body 2.5 mfd.
S&F in replacement of fan capacitor with copper wire plastic body 3.15 mfd.
Taking down the old white hylium sheet from the existing flash metal box and replacing new supper quality white hylium sheet of size 8" x 10" complete all as specified and as directed by Engineer-in-Charge.
All as per srl item 104 above but of size 5" x 5" complete all as specified and as directed by Engineer-in-Charge.
All as per srl item 104 above but of size 8" x 5" complete all as specified and as directed by Engineer-in-Charge.
All as per srl item 104 above but of size 9" x 13" complete all as specified and as directed by Engineer-in-Charge.
Supply & fix in replacement of brass screw 3/18, long threaded suitable for fixing switch boards. ( 100 Nos in one packet)
Supply & fix in replacement of brass screw 9/11, long threaded suitable for fixing switch boards. ( 100 Nos in one packet)
Supply & fix in replacement of stainless steel screw 1/2" long. ( 200 Nos in one packet)
Supply & fix in replacement of stainless steel screw 1" long.( 200 Nos in one packet)
Supply and fix in replacement of flexible wire twin core 23/.076 complete all as specified and as directed by Engr-in- Charge. Each roll of 100 mtr.
Excavation in trenches in hard and dense soil n exc 1.5 mtr wide and n.exc 1.5 mtr in depth for laying of pipe,foundation for poles, stay, laying cables etc and getting out copmlete all as directed by engineer-in-charge.
Supply and laying GI pipe light grade galvanized with all fittings laid in trenches or fix on wall for cable protection of 80 mm bore copmlete all as directed by engineer-in-charge.
All as per srl item No 114 above but size 50 mm bore copmlete all as directed by engineer-in-charge.
All as per srl item No 114 above but size 40 mm bore copmlete all as directed by engineer-in-charge.
Disconnecting,removing & taking out faulty U/G cable off sizes from trenches,wall and ducts complete all specified and as directed
Supply, Laying, Testing and connecting cable XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volts gradesize 10 Sq mm x 2 core copmlete all as directed by engineer-in-charge.
Material and labour for cutting of road/ hard standing up to a size not exceeding 20cm width and not exceeding 60cm in depth for laying of cable protection pipe including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1 and block top with black bituminous upto existing surface level complete all as specified and as directed by Engineer-in-charge.
Preparation of old painted surface of steel tubular swaged poles (9 to 11 meter long) with good neck brackets including junction box, GI pipe and light fittings i.e HPSV/HPMV any rating and painting with one coat of aluminium paint including cleaning the acrylic cover and painting with black to 1.5 mtr height from top of PCC coping and marking pole numbers with one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including galvanized iron strip 25 x 4 mm as earth lead by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 5 of SSR Part I (1991) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. Note :- PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI)
Material and labour for galvanised iron strip 25 X 4 mm with saddles and fixing screws and connected as per site requirement comlete all as specified and as directed by Engineer-in-Charge.
Taking down street light, garden light and flood light fitting etc complete all as specified and as directed.
S&F LED post top lantern fittings with powder coated aluminium die cast and spun aluminium body with clear/opal diffuser suitable for landscape lighting available in 5700K CCT,IP65. also availble in 3000K & 4000K on demand of item code No PGR0201008 model PCGLPT 01 25 C of all as specified and directed by engineer - in- charge.
S&F LED post top lantern fittings with powder coated aluminium die cast and spun aluminium body with clear/opal diffuser suitable for landscape lighting available in 5700K CCT,IP65. also availble in 3000K & 4000K on demand of item code No PGR0201010 model No PCGLPT 01 40 C of all as specified and directed by engineer - in- charge.
Supply and fix in replacement of new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection with high power 200 watt LED , 6000K , with electronic driver, general spread of cat Part No 9405 of make Havells and equivelent make of phillips/CG with all accessories pre-wired and electric connection using PVC insulated and sheathed 1100 volts grade cable with copper conductor of size 2.5 sqmm complete with provn of nuts and bolts fixing on walls/poles etc. complete all as specified.
Supply and fix tape insulation PVC 25 mm wide in various colours of standard length complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type Cat Part No - DHDPSHODRW08 complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 12 way 230 volts double door type regal gray horizontal type Cat Part No - DHDPSHODRW08 complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCBs 10 KA breaking capacity, single pole, 240 volts, 6 to 40 amps C Curve capacity.
Supply and fixing in replacement MCBs 10 KA breaking capacity, single pole, and neutral, 240 volts, 40/63 amps C Curve capacity.
J.P. Enterprises
shakti construction
YANSHIKA SECURITY SERVICES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .